969 resultados para wavelength tuning


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Signal processing methods based on the combined use of the continuous wavelet transform (CWT) and zero-crossing technique were applied to the simultaneous spectrophotometric determination of perindopril (PER) and indapamide (IND) in tablets. These signal processing methods do not require any priory separation step. Initially, various wavelet families were tested to identify the optimum signal processing giving the best recovery results. From this procedure, the Haar and Biorthogonal1.5 continuous wavelet transform (HAAR-CWT and BIOR1.5-CWT, respectively) were found suitable for the analysis of the related compounds. After transformation of the absorbance vectors by using HAAR-CWT and BIOR1.5-CWT, the CWT-coefficients were drawn as a graph versus wavelength and then the HAAR-CWT and BIOR1.5-CWT spectra were obtained. Calibration graphs for PER and IND were obtained by measuring the CWT amplitudes at 231.1 and 291.0 nm in the HAAR-CWT spectra and at 228.5 and 246.8 nm in BIOR1.5-CWT spectra, respectively. In order to compare the performance of HAAR-CWT and BIOR1.5-CWT approaches, derivative spectrophotometric (DS) method and HPLC as comparison methods, were applied to the PER-IND samples. In this DS method, first derivative absorbance values at 221.6 for PER and 282.7 nm for IND were used to obtain the calibration graphs. The validation of the CWT and DS signal processing methods was carried out by using the recovery study and standard addition technique. In the following step, these methods were successfully applied to the commercial tablets containing PER and IND compounds and good accuracy and precision were reported for the experimental results obtained by all proposed signal processing methods.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A spectrophotometric method was proposed for Ni(II) determination in alloys using a dopa-semiquinone (L-1) to form [Ni(II)(L1-)3]1-, ε = 9.3 x 10³ L mol-1 cm-1. The optimal conditions for the determination were: wavelength 590 nm, temperature 25 °C, reaction time 45 min and pH 7.5. The Beer's law was obeyed for nickel from 3.33 x 10-5 to 1.78 x 10-4 mol L-1. The method was applied to complex samples, such as inox, nickel-titanium and cobalt-chromium alloys. A study of the potential interferents revealed that Mn was the major interferent. The limit of detection and quantification were 2.88 x 10-5 mol L-1 and 3.06 x 10-5 mol L-1, respectively.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The organic acids (tartaric, malic, citric, lactic and succinic) are de main components responsible for the acidity in the wine. This method for simultaneous determination of organic acids and interfering peaks in wines can be achieved in 16 min. The sample preceded by a dilution and filtration step. The chromatographic separation required one reversed phase column, isocratic mobile phase (acetonitrila, formic acid in water) and detection wavelength was set at 212 nm. The validation confirmed good repeatability, recovery and application in red and white wines.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This article describes the use of a projection spectrograph based on an overhead projector for use in classroom demonstrations on light polarization and optical activity. A simple adaptation on a previously developed apparatus allows illustrating several aspects of optical activity, such as circular and linear birefringence, including their wavelength dependence. Specifically, we use the projection spectrograph to demonstrate the optical activity of an aqueous solution of sugar (circular birefringence), of a quartz plate and of an overhead projector transparence film (linear birefringence). A historical survey about the optical activity discovery and the main principles involved is also presented.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The purpose of this study was to improve PM7’s basis weight CD profile in Stora Enso’s Berghuizer mill and to search mechanical defects which affect to the formation of the basis weight CD profile. In the theoretical part PM7’s structure was presented and the formation of the basis weight and caliper CD profiles was examined as well as disturbances which are affecting to the formation. The function of the control system was scrutinised for the side of CD profiles as well as the formation of the measured CD profiles. Tuning of the control system was examined through the response model and filtering. Specification of the response model and filtering was explained and how to determine 2sigma statistical number. In the end of the theoretical part ATPA hardware and a new profile browser were introduced. In the experimental part focus was in the beginning to search and remove mechanical defects which are affecting to CD profiles. The next step was to verify the reliability of the online measurements, to study the stability of the basis weight CD profile and to find out so called fingerprint, a basis weight CD profile which is unique for each paper machine. New response model and filtering value for basis weight CD profile was determined by bump tests. After a follow up period the affect of the new response model and filtering was analysed.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In this work, a rapid and simple method using capillary electrophoresis (CE) was developed for the determination of the benzoate, sorbate, methyl and propylparaben in foodstuffs. A running buffer consisting of 20 mmol L-1 (pH = 9.3) tetraborate enabled separation of the analytes in less than 5 min. The detector wavelength was set at 220 nm. The method was successfully applied to the analysis of sodas, sweeteners, sauces and juices. The range of preservatives found were from 478.5-466.6 mg kg-1 for methylparaben , 83.7-231.3 mg kg-1 for sorbate and 336.7-428.3 mg kg-1 for benzoate.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This study reports on the construction of a turbidimeter employing light emitting diodes as radiation source at a wavelength of 405 nm, a photodiode as detector, a temperature sensor and a microcontroller used for data acquisition and processing. The turbidimeter was applied to determine sulfate concentrations in natural water employing barium chloride as reagent. Potential interferences and recovery studies were performed and an interference of 3.5 % and a recovery between 97.8 and 108 % were estimated. The analytical performance of in situ turbidimeter for the determination of sulfate was evaluated and compared with two commercial spectrophotometers and a good agreement was obtained.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Caesalpinia peltophoroides is a domesticated tree found in Brazil. It was necessary to develop an analytical method to determine the content of total polyphenols (TP) in this herbal drug. The pre-analytical method was standardized for analysis time, wavelength, and the best standard to use. The optimum conditions were: pyrogallol, 760 nm, and 30 min respectively. Under these conditions, validation by UV/Vis spectrophotometry proved to be reliable for TP of the crude extract and semipurified fractions from C. peltophoroides. Standardization is required for every herbal drug, and this method proved to be linear, precise, accurate, reproducible, robust, and easy to perform.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This work focused on the development and validation of an RP-HPLC-UV method for quantification of beta-lactam antibiotics in three pharmaceutical samples. Active principles analyzed were amoxicillin and ampicillin, in 3 veterinary drugs. Mobile phase comprised 5 mmol L-1 phosphoric acid solution at pH 2.00, acetonitrile with gradient elution mode and detection wavelength at 220 nm. The method was validated according to the Brazilian National Health Surveillance regulation, where linear range and linearity, selectivity, precision, accuracy and ruggedness were evaluated. Inter day precision and accuracy for pharmaceutical samples 1, 2 and 3 were: 1.43 and 1.43%; 4.71 and 3.74%; 2.72 and 1.72%, respectively, while regression coefficients for analytical curves exceeded 0.99. The method had acceptable merit figure values, indicating reliable quantification. Analyzed samples had active principle concentrations varying from -12 to +21% compared to manufacturer label claims, rendering the medicine unsafe for administration to animals.