976 resultados para transitive calibration


Relevância:

10.00% 10.00%

Publicador:

Resumo:

A simple laser refractometer based on the detection of the critical angle for liquids is presented. The calibrated refractometer presents up to 0.000 11 of uncertainty when the refractive index is in the range between 1.300 00 and 1.340 00. The experimental setup is easy to construct and the material needed is available at most optics laboratories. The calibration method is simple and can be used in other devices. The refractive index measurements in aqueous solutions of sodium chloride were carried out to test the device and a linear dependence between the refractive index and the salt concentration was found. © 2006 American Institute of Physics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This paper presents a simple design and the testing of a blackbody prototype. The physical properties and geometry of the cavity produce a radiator or blackbody with an emissivity greater than 0.99. The prototype has the advantages of having a traditional spherical cavity made of alumina refractory cement and a radiative emission very close to that of an ideal blackbody. The prototype can be used as a calibration standard for other radiation measuring instruments or sensors. Experimental measurements of radiant flux of the prototype measured with a calibrated infrared radiometer and a wide spectrum radiometer are also presented. The prototype is easy to construct and the material required are available to most research centers, laboratories, industries, and universities. © 2010 American Institute of Physics.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim: To study the pharmacokinetics of sifuvirtide, a novel anti-human immunodeficiency virus (HIV) peptide, in monkeys and to compare the inhibitory concentrations of sifuvirtide and enfuvirtide on HIV-1-infected-cell fusion. Methods: Monkeys received 1.2 mg/kg iv or sc of sifuvirtide. An on-line solid-phase extraction procedure combined with liquid chromatography tandem mass spectrometry (SPELC/MS/MS) was established and applied to determine the concentration of sifuvirtide in monkey plasma. A four-I-127 iodinated peptide was used as an internal standard. Fifty percent inhibitory concentration (IC50) of sifuvirtide on cell fusion was determined by co-cultivation assay. Results: The assay was validated with good precision and accuracy. The calibration curve for sifuvirtide in plasma was linear over a range of 4.88-5000 mu g/L, with correlation coefficients above 0.9923. After iv or sc administration, the observed peak concentrations of sifuvirtide were 10626 +/- 2886 mu g/L and 528 +/- 191 mu g/L, and the terminal elimination half-lives (T,12) were 6.3 +/- 0.9 h and 5.5 +/- 1.0 h, respectively. After sc, T-max was 0.25-2 h, and the absolute bioavailability was 49% +/- 13%. Sifuvirtide inhibited the syncytium formation between HIV-1 chronically infected cells and uninfected cells with an IC50 of 0.33 mu g/L. Conclusion: An on-line SPE-LC/MS/MS approach was established for peptide pharmacokinetic studies. Sifuvirtide was rapidly absorbed subcutaneously into the blood circulation. The T-1/2 of sifuvirtide was remarkably longer than that of its analog, enfuvirtide, reported in healthy monkeys and it conferred a long-term plasma concentration level which was higher than its IC50 in vitro.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

At the fishing season, in 2000, samples of species persian sturgeon (A. persicus), Severjuga (A. stellatus) and Mullet (L. aurata), were caught from the southern coasts of Caspian Sea and were freezes and preserved in the cold storage for one year They have also become biometery. The tissue's fillet were identified in order to determined the Fatty Acids. This was done during one year, frequently, fresh, two weeks after freezing and then monthly, respectively. So, after the extraction of lipids from the tissues and methylation, was injected to the gas-liquid Chromatography. After calibration, identified Fatty Acids were compared with standards according to their Retention Times. Peroxid value, lipid content and humidity were controlled. The unsaturated Fatty acids had The most amount, and a plenty of Polyunsaturated Fatty acids (PUFA) were observed, so that linoleic (C18:2), a-linolenic (C18:3), Arashidonic (C20:4), EPA (C20:5) and DHA (C22:6) Fatty acids had high amounts. The w-3, PUFA were more in comparison with w-6. The effects of freezing and cold storing on the fish fatty acids , were evaluated by the statistical tests , like SPSS, Tukey, Homogenous and Anova, and showed that in some species, a group of Fatty acids, specially PUFA, had some variation. The peroxide value that indicates the lipid deterioration, increased during toring. So, the best term if preserving in the cold storage, were determined and their Nutrition value and Medical applications due to their consumption were investigated.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Phylogenetic relationships among 15 species of wood mice (genus Apodemus) were reconstructed to explore some long-standing taxonomic problems. The results provided support for the monophyly of the genus Apodemus, but could not reject the hypothesis of paraphyly for this genus. Our data divided the 15 species into four major groups: (1) the Sylvaemus group (A. sylvaticus, A. flavicollis, A. alpicola, and A. uralensis), (2) the Apodemus group (A. peninsulae, A. chevreri, A. agrarius, A. speciosus, A. draco, A. ilex, A. semotus, A. latronum, and A. mystacinus), (3) A. argenteus, and (4) A. gurkha. Our results also suggested that orestes should be a valid subspecies of A. draco rather than an independent species; in contrast, A. ilex from Yunnan may be regarded as a separate species rather than a synonym of orestes or draco. The species level status of A. latronum, tscherga as synonyms of A. uralensis, and A. chevrieri as a valid species and the closest sibling species of A. agrarius were further corroborated by our data. Applying a molecular clock with the divergences of Mus and Rattus set at 12 million years ago (Mya) as a calibration point, it was estimated that five old lineages (A. mystacinus and four major groups above) diverged in the late Miocene (7.82-12.74 Mya). Then the Apodemus group (excluding A. mystacinus) split into two subgroups: agrarius and draco, at about 7.17-9.95 Mya. Four species of the Sylvaemus group were estimated to diverge at about 2.92-5.21 Mya. The Hengduan Mountains Region was hypothesized to have played important roles in Apodemus evolutionary histories since the Pleistocene. (C) 2004 Elsevier Inc. All rights reserved.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The movement of the circular piston in an oscillating piston positive displacement flowmeter is important in understanding the operation of the flowmeter, and the leakage of liquid past the piston plays a key role in the performance of the meter. The clearances between the piston and the chamber are small, typically less than 60 νm. In order to measure this film thickness a fluorescent dye was added to the water passing through the meter, which was illuminated with UV light. Visible light images were captured with a digital camera and analysed to give a measure of the film thickness with an uncertainty of less than 7%. It is known that this method lacks precision unless careful calibration is undertaken. Methods to achieve this are discussed in the paper. The grey level values for a range of film thicknesses were calibrated in situ with six dye concentrations to select the most appropriate one for the range of liquid film thickness. Data obtained for the oscillating piston flowmeter demonstrate the value of the fluorescence technique. The method is useful, inexpensive and straightforward and can be extended to other applications where measurement of liquid film thickness is required. © 2011 IOP Publishing Ltd.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Optimisation of cooling systems within gas turbine engines is of great interest to engine manufacturers seeking gains in performance, efficiency and component life. The effectiveness of coolant delivery is governed by complex flows within the stator wells and the interaction of main annulus and cooling air in the vicinity of the rim seals. This paper reports the development of a test facility which allows the interaction of cooling air and main gas paths to be measured at conditions representative of those found in modern gas turbine engines. The test facility features a two stage turbine with an overall pressure ratio of approximately 2.6:1. Hot air is supplied to the main annulus using a Rolls-Royce Dart compressor driven by an aero-derivative engine plant. Cooling air can be delivered to the stator wells at multiple locations and at a range of flow rates which cover bulk ingestion through to bulk egress. The facility has been designed with adaptable geometry to enable rapid changes of cooling air path configuration. The coolant delivery system allows swift and accurate changes to the flow settings such that thermal transients may be performed. Particular attention has been focused on obtaining high accuracy data, using a radio telemetry system, as well as thorough through-calibration practices. Temperature measurements can now be made on both rotating and stationary discs with a long term uncertainty in the region of 0.3 K. A gas concentration measurement system has also been developed to obtain direct measurement of re-ingestion and rim seal exchange flows. High resolution displacement sensors have been installed in order to measure hot running geometry. This paper documents the commissioning of a test facility which is unique in terms of rapid configuration changes, non-dimensional engine matching and the instrumentation density and resolution. Example data for each of the measurement systems is presented. This includes the effect of coolant flow rate on the metal temperatures within the upstream cavity of the turbine stator well, the axial displacement of the rotor assembly during a commissioning test, and the effect of coolant flow rate on mixing in the downstream cavity of the stator well. Copyright © 2010 by ASME.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The uncertainty associated with a rainfall-runoff and non-point source loading (NPS) model can be attributed to both the parameterization and model structure. An interesting implication of the areal nature of NPS models is the direct relationship between model structure (i.e. sub-watershed size) and sample size for the parameterization of spatial data. The approach of this research is to find structural limitations in scale for the use of the conceptual NPS model, then examine the scales at which suitable stochastic depictions of key parameter sets can be generated. The overlapping regions are optimal (and possibly the only suitable regions) for conducting meaningful stochastic analysis with a given NPS model. Previous work has sought to find optimal scales for deterministic analysis (where, in fact, calibration can be adjusted to compensate for sub-optimal scale selection); however, analysis of stochastic suitability and uncertainty associated with both the conceptual model and the parameter set, as presented here, is novel; as is the strategy of delineating a watershed based on the uncertainty distribution. The results of this paper demonstrate a narrow range of acceptable model structure for stochastic analysis in the chosen NPS model. In the case examined, the uncertainties associated with parameterization and parameter sensitivity are shown to be outweighed in significance by those resulting from structural and conceptual decisions. © 2011 Copyright IAHS Press.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Failure of retaining walls is observed after many recent seismic events. Design of these walls are based on the pseudo-static force designs based on the Mononobe-Okabe earth pressure coefficient equations. However, it is clear that there are limitations attached with this approach. This paper investigates the seismic behaviour of sheet pile retaining walls using dynamic centrifuge testing facilities. In addition to using bending moment strain gauges on the wall, new generation earth pressure cells have also been used to investigate the generation of active and passive earth pressures. The results indicate that Mononobe-Okabe equations give relatively good estimates of active earth pressures but may be over-predicting passive earth pressures at certain peak ground acceleration levels. Based on this series of centrifuge tests it is concluded that earth pressure cells are successful in providing good qualitative data, but need to be supplemented by good calibration methods. © 2010 Taylor & Francis Group, London.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present a multispectral photometric stereo method for capturing geometry of deforming surfaces. A novel photometric calibration technique allows calibration of scenes containing multiple piecewise constant chromaticities. This method estimates per-pixel photometric properties, then uses a RANSAC-based approach to estimate the dominant chromaticities in the scene. A likelihood term is developed linking surface normal, image intensity and photometric properties, which allows estimating the number of chromaticities present in a scene to be framed as a model estimation problem. The Bayesian Information Criterion is applied to automatically estimate the number of chromaticities present during calibration. A two-camera stereo system provides low resolution geometry, allowing the likelihood term to be used in segmenting new images into regions of constant chromaticity. This segmentation is carried out in a Markov Random Field framework and allows the correct photometric properties to be used at each pixel to estimate a dense normal map. Results are shown on several challenging real-world sequences, demonstrating state-of-the-art results using only two cameras and three light sources. Quantitative evaluation is provided against synthetic ground truth data. © 2011 IEEE.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Estimating the fundamental matrix (F), to determine the epipolar geometry between a pair of images or video frames, is a basic step for a wide variety of vision-based functions used in construction operations, such as camera-pair calibration, automatic progress monitoring, and 3D reconstruction. Currently, robust methods (e.g., SIFT + normalized eight-point algorithm + RANSAC) are widely used in the construction community for this purpose. Although they can provide acceptable accuracy, the significant amount of required computational time impedes their adoption in real-time applications, especially video data analysis with many frames per second. Aiming to overcome this limitation, this paper presents and evaluates the accuracy of a solution to find F by combining the use of two speedy and consistent methods: SURF for the selection of a robust set of point correspondences and the normalized eight-point algorithm. This solution is tested extensively on construction site image pairs including changes in viewpoint, scale, illumination, rotation, and moving objects. The results demonstrate that this method can be used for real-time applications (5 image pairs per second with the resolution of 640 × 480) involving scenes of the built environment.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Vision trackers have been proposed as a promising alternative for tracking at large-scale, congested construction sites. They provide the location of a large number of entities in a camera view across frames. However, vision trackers provide only two-dimensional (2D) pixel coordinates, which are not adequate for construction applications. This paper proposes and validates a method that overcomes this limitation by employing stereo cameras and converting 2D pixel coordinates to three-dimensional (3D) metric coordinates. The proposed method consists of four steps: camera calibration, camera pose estimation, 2D tracking, and triangulation. Given that the method employs fixed, calibrated stereo cameras with a long baseline, appropriate algorithms are selected for each step. Once the first two steps reveal camera system parameters, the third step determines 2D pixel coordinates of entities in subsequent frames. The 2D coordinates are triangulated on the basis of the camera system parameters to obtain 3D coordinates. The methodology presented in this paper has been implemented and tested with data collected from a construction site. The results demonstrate the suitability of this method for on-site tracking purposes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The composite nature of mineralized natural materials is achieved through both the microstructural inclusion of an organic component and an overall microstructure that is controlled by templating onto organic macromolecules. A modification of an existing laboratory technique is developed for the codeposition of a CaCO3-gelatin composite with a controllable organic content. First, calibration curves are developed to determine the organic content of a CaCO3-gelatin composite from infrared spectra. Second, a CaCO3-gelatin composite is deposited on either glass coverslips or demineralized eggshell membranes using an automated alternating soaking process. Electron microscopy images and use of the infrared spectra calibration curves show that by altering the amount of gelatin in the ionic growth solutions, the final organic component of the mineral can be regulated over the range of 1-10%, similar to that of natural eggshell. © 2012 Materials Research Societ.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Localization of chess-board vertices is a common task in computer vision, underpinning many applications, but relatively little work focusses on designing a specific feature detector that is fast, accurate and robust. In this paper the `Chess-board Extraction by Subtraction and Summation' (ChESS) feature detector, designed to exclusively respond to chess-board vertices, is presented. The method proposed is robust against noise, poor lighting and poor contrast, requires no prior knowledge of the extent of the chess-board pattern, is computationally very efficient, and provides a strength measure of detected features. Such a detector has significant application both in the key field of camera calibration, as well as in Structured Light 3D reconstruction. Evidence is presented showing its robustness, accuracy, and efficiency in comparison to other commonly used detectors both under simulation and in experimental 3D reconstruction of flat plate and cylindrical objects

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Electron multiplication charge-coupled devices (EMCCD) are widely used for photon counting experiments and measurements of low intensity light sources, and are extensively employed in biological fluorescence imaging applications. These devices have a complex statistical behaviour that is often not fully considered in the analysis of EMCCD data. Robust and optimal analysis of EMCCD images requires an understanding of their noise properties, in particular to exploit fully the advantages of Bayesian and maximum-likelihood analysis techniques, whose value is increasingly recognised in biological imaging for obtaining robust quantitative measurements from challenging data. To improve our own EMCCD analysis and as an effort to aid that of the wider bioimaging community, we present, explain and discuss a detailed physical model for EMCCD noise properties, giving a likelihood function for image counts in each pixel for a given incident intensity, and we explain how to measure the parameters for this model from various calibration images. © 2013 Hirsch et al.