986 resultados para test object relations
Resumo:
BACKGROUND Skin patch test is the gold standard method in diagnosing contact allergy. Although used for more than 100 years, the patch test procedure is performed with variability around the world. A number of factors can influence the test results, namely the quality of reagents used, the timing of the application, the patch test series (allergens/haptens) that have been used for testing, the appropriate interpretation of the skin reactions or the evaluation of the patient's benefit. METHODS We performed an Internet -based survey with 38 questions covering the educational background of respondents, patch test methods and interpretation. The questionnaire was distributed among all representatives of national member societies of the World Allergy Organization (WAO), and the WAO Junior Members Group. RESULTS One hundred sixty-nine completed surveys were received from 47 countries. The majority of participants had more than 5 years of clinical practice (61 %) and routinely carried out patch tests (70 %). Both allergists and dermatologists were responsible for carrying out the patch tests. We could observe the use of many different guidelines regardless the geographical distribution. The use of home-made preparations was indicated by 47 % of participants and 73 % of the respondents performed 2 or 3 readings. Most of the responders indicated having patients with adverse reactions, including erythroderma (12 %); however, only 30 % of members completed a consent form before conducting the patch test. DISCUSSION The heterogeneity of patch test practices may be influenced by the level of awareness of clinical guidelines, different training backgrounds, accessibility to various types of devices, the patch test series (allergens/haptens) used for testing, type of clinical practice (public or private practice, clinical or research-based institution), infrastructure availability, financial/commercial implications and regulations among others. CONCLUSION There is a lack of a worldwide homogeneity of patch test procedures, and this raises concerns about the need for standardization and harmonization of this important diagnostic procedure.
Resumo:
Background: Glutathione (GSH), a major cellular redox regulator and antioxidant, is decreased in cerebrospinal fluid and prefrontal cortex of schizophrenia patients. The gene of the key GSH-synthesizing enzyme, glutamate-cysteine ligase, modifier (GCLM) subunit, is associated with schizophrenia, suggesting that the deficit in the GSH system is of genetic origin. Using the GCLM knock-out (KO) mouse as model system with 60% decreased brain GSH levels and, thus, strong vulnerability to oxidative stress, we have shown that GSH dysregulation results in abnormal mouse brain morphology (e.g., reduced parvalbumin, PV, immuno-reactivity in frontal areas) and function. Additional oxidative stress, induced by GBR12909 (a dopamine re-uptake inhibitor), enhances morphological changes even further. Aim: In the present study we use the GCLM KO mouse model system, asking now, whether GSH dysregulation also compromises mouse behaviour and cognition. Methods: Male and female wildtype (WT) and GCLM-KO mice are treated with GBR12909 or phosphate buffered saline (PBS) from postnatal day (P) 5 to 10, and are behaviourally tested at P 60 and older. Results: In comparison to WT, KO animals of both sexes are hyperactive in the open field, display more frequent open arm entries on the elevated plus maze, longer float latencies in the Porsolt swim test, and more frequent contacts of novel and familiar objects. Contrary to other reports of animal models with reduced PV immuno-reactivity, GCLM-KO mice display normal rule learning capacity and perform normally on a spatial recognition task. GCLM-KO mice do, however, show a strong deficit in object-recognition after a 15 minutes retention delay. GBR12909 treatment exerts no additional effect. Conclusions: The results suggest that animals with impaired regulation of brain oxidative stress are impulsive and have reduced behavioural control in novel, unpredictable contexts. Moreover, GSH dysregulation seems to induce a selective attentional or stimulus-encoding deficit: despite intensive object exploration, GCLM-KO mice cannot discriminate between novel and familiar objects. In conclusion, the present data indicate that GSH dysregulation may contribute to the manifestation of behavioural and cognitive anomalies that are associated with schizophrenia.
Resumo:
ABSTRACT This paper addresses the changes in university-industry relations in Brazil regarding innovation activities. It is based on a survey of articles published in major national journals or presented at the most relevant Brazilian and regional conferences, between 1980 and 2012. The year 1980 was chosen due to the creation of the Technological Innovation Offices (NITs), which was the first government initiative to encourage knowledge transfer from universities to companies; the second was the Innovation Act of 2004. Our assumption was that after the Act the number of academic papers on this subject would increase, bringing new ideas and propositions of models to enhance this relationship. The methodology employed a qualitative, exploratory approach, using bibliographical research and a bibliometric analysis of 247 papers. Literature review of international studies shows the discussion of problems and suggestions for improvements, while in Brazil there is still a debate on whether this collaboration should occur, and if this is a legitimate role for the university. Despite the numerical growth, the content analysis showed few papers on new configurations and procedures for partnership management. We conclude that university-industry relations are not a regular and totally accepted process in Brazilian public universities, which reflect an ideological bias against cooperation with firms.
Resumo:
Agency Performance Plan
Resumo:
Purpose: To investigate the effect of incremental increases in intraocular straylight on threshold measurements made by three modern forms of perimetry: Standard Automated Perimetry (SAP) using Octopus (Dynamic, G-Pattern), Pulsar Perimetry (PP) (TOP, 66 points) and the Moorfields Motion Displacement Test (MDT) (WEBS, 32 points).Methods: Four healthy young observers were recruited (mean age 26yrs [25yrs, 28yrs]), refractive correction [+2 D, -4.25D]). Five white opacity filters (WOF), each scattering light by different amounts were used to create incremental increases in intraocular straylight (IS). Resultant IS values were measured with each WOF and at baseline (no WOF) for each subject using a C-Quant Straylight Meter (Oculus, Wetzlar, Germany). A 25 yr old has an IS value of ~0.85 log(s). An increase of 40% in IS to 1.2log(s) corresponds to the physiological value of a 70yr old. Each WOFs created an increase in IS between 10-150% from baseline, ranging from effects similar to normal aging to those found with considerable cataract. Each subject underwent 6 test sessions over a 2-week period; each session consisted of the 3 perimetric tests using one of the five WOFs and baseline (both instrument and filter were randomised).Results: The reduction in sensitivity from baseline was calculated. A two-way ANOVA on mean change in threshold (where subjects were treated as rows in the block and each increment in fog filters was treated as column) was used to examine the effect of incremental increases in straylight. Both SAP (p<0.001) and Pulsar (p<0.001) were significantly affected by increases in straylight. The MDT (p=0.35) remained comparatively robust to increases in straylight.Conclusions: The Moorfields MDT measurement of threshold is robust to effects of additional straylight as compared to SAP and PP.
Resumo:
Creació d'una aplicació web que genera exàmens tipus test agafant les preguntes d'un banc de preguntes. Genera una versió per cada alumne del mateix exàmen, amb les preguntes desordenades i les opcions també desordenades. A cada resposta se li associa un número. El resultat de l'exàmen és la suma de les repostes. Mitjançant el criptosistema Knapsack ficant a l'aplicació el número resultat de l'exàmen s'obté la nota.
Resumo:
Most ventricular assist devices (VADs) currently used in infants are extracorporeal. These VADs require long-term anticoagulation therapy and extensive surgery, and two devices are needed for biventricular support. We designed a biventricular assist device based on shape memory alloy that reproduces the hemodynamic effects of cardiomyoplasty, supporting the heart with a compressing movement, and evaluated its performance in a dedicated mockup system. Nitinol fibers are the device's key component. Ejection fraction (EF), cardiac output (CO), and generated systolic pressure were measured on a test bench. Our test bench settings were a preload range of 0-15 mm Hg, an afterload range of 0-160 mm Hg, and a heart rate (HR) of 20, 30, 40, and 60 beats/min. A power supply of 15 volts and 3.5 amperes was necessary. The EF range went from 34.4% to 1.2% as the afterload and HR increased, along with a CO from 180 to 6 ml/min. The device generated a maximal systolic pressure of 25 mm Hg. Cardiac compression for biventricular assistance in child-sized heart using shape memory alloy is technically feasible. Further testing remains necessary to assess this VAD's in vivo performance range and its reliability.
Resumo:
Introduction: La disposition de l'imatinib (Glivec®) implique des systèmes connus pour de grandes différences inter-individuelles, et l'on peut s'attendre à ce que l'exposition à ce médicament varie largement d'un patient à l'autre. L'alpha-1-glycoprotéine acide (AAG), une protéine circulante liant fortement l'imatinib, représente l'un de ces systèmes. Objectif: Cette étude observationnelle visait à explorer l'influence de l'AAG plasmatique sur la pharmacocinétique de l'imatinib. Méthode: Une analyse de population a été effectuée avec le programme NONMEM sur 278 échantillons plasmatiques issus de 51 patients oncologiques. L'influence des taux d'AAG sur la clairance (CL) et le volume de distribution (Vd) a ainsi été étudiée. Résultats: Un modèle à un compartiment avec absorption de premier ordre a permis de décrire les données. Une relation hyperbolique entre taux d'AAG et CL ou Vd a été observée. Une approche mécanistique a donc été élaborée, postulant que seule la concentration libre subissait une élimination du premier ordre, et intégrant la constante de dissociation comme paramètre du modèle. Cette approche a permis de déterminer une CLlibre moyenne de 1310 l/h et un Vd de 301 l. Par comparaison, la CLtotale déterminée initialement était de 14 l/h. La CLlibre est affectée par le poids corporel et le type de pathologie. Qui plus est, ce modèle a permis d'estimer in vivo la constante d'association entre imatinib et AAG (5.5?106 l/mol), ainsi que la fraction libre moyenne de l'imatinib (1.1%). La variabilité inter-individuelle estimée pour la disposition de l'imatinib (17% sur CLlibre et 66% sur Vd) diminuait globalement de moitié avec le modèle incorporant l'impact de l'AAG. Discussion-conclusion: De tels résultats clarifient l'impact de la liaison protéinique sur le devenir de l'imatinib. Des taux élevés d'AAG ont été présumés représenter un facteur de résistance à l'imatinib. Toutefois, cela est peu probable, notre modèle prédisant que la concentration libre reste inchangée. D'un autre côté, s'il est un jour démontré que l'imatinib requiert un programme de suivi thérapeutique (TDM), la mesure des concentrations libres, ou la correction des concentrations totales en fonction des taux d'AAG, devraient être envisagées pour une interprétation précise des résultats.