982 resultados para resonant cavity enhanced
Resumo:
Multi-wavelength picosecond pulses are demonstrated using a single monolithically integrated Multi-wavelength Grating Cavity (MGC) laser. This is achieved on two WDM wavelength channels at a repetition rate of 7.63 GHz.
Resumo:
Etched VCSEL sources are reported which avoid bandwidth collapse in multimode fibre using a simple coupling technique to control the launch. These devices have allowed better than over-filled launch bandwidth for alignment tolerances of ±7 microns.
Resumo:
A continuous Gaussian profile matched to the fundamental mode was etched onto the aperture of a vertical cavity surface emitting laser (VCSEL). Single Gaussian spot emission was achieved over the entire operating current range.
Resumo:
High-speed configuration results of a conventional 850 nm VCSEL that is modified to operate as an efficient avalanche detector as well as a laser are discussed. The measured laser-to-detector reconfiguration delay of 3.2 ns is longer than the 1.2 ns detector-to-detector reconfiguration delay.
Resumo:
A novel integrated Multi-Wavelength Grating Cavity (MGC) laser has been used for multi-channel wavelength conversion at 2.488Gbits/s. Functions demonstrated include conversion to multiple wavelengths, WDM multiplexing and 1×4 space switching.
Resumo:
In order to develop materials that exhibit enhanced flexoelectric switching in the chiral nematic phase we have identified mesogenic units that display inherently strong flexoelectric coupling capabilities. Here we examine the oxycyanobiphenyl (OCB) moiety: homologues from the nOCB series exhibit significant electro-optic switching effects when doped with a highly chiral additive. Here we have examined lower dielectric anisotropy materials, since they allow the flexoelectric response to be extended to high field amplitudes. We show that dielectric coupling strength can be low in symmetric bimesogenic molecules. The flexoelectric response of such a molecular structure is tested by doping a homologue from the series CBOnOCB with a chiral additive: very significantly we find that the optic axis is rotated through 2φ=45° in <50 μs on reversing the polarity of the field (amplitude E=±6 V μm-1). Subsequently we have synthesized room temperature chiral nematic materials that exhibit 2φ≥90° at E≈10 V μm-1. © 2001 OPA (Overseas Publishers Association) N.V. Published by license under the Gordon and Breach Science Publishers imprint, a member of the Taylor & Francis Group.
Resumo:
Prenatal stress can cause many long-term behavior changes in offspring, but whether prenatal stress can alter addictive behavior in offspring and postnatal enriched environment treatment (EE) can restore these changes are unknown. We reported here that pr
Resumo:
In this paper we present Poisson sum series representations for α-stable (αS) random variables and a-stable processes, in particular concentrating on continuous-time autoregressive (CAR) models driven by α-stable Lévy processes. Our representations aim to provide a conditionally Gaussian framework, which will allow parameter estimation using Rao-Blackwellised versions of state of the art Bayesian computational methods such as particle filters and Markov chain Monte Carlo (MCMC). To overcome the issues due to truncation of the series, novel residual approximations are developed. Simulations demonstrate the potential of these Poisson sum representations for inference in otherwise intractable α-stable models. © 2011 IEEE.
Resumo:
A novel type of linear extensometer with exceptionally high resolution of 4 nm based on MEMS resonant strain sensors bonded on steel and operating in a vacuum package is presented. The tool is implemented by means of a steel thin bar that can be pre-stressed in tension within two fixing anchors. The extension of the bar is detected by using two vacuum-packaged resonant MEMS double- ended tuning fork (DETF) sensors bonded on the bar with epoxy glue, one of which is utilized for temperature compensation. Both sensors are driven by a closed loop self-oscillating transresistance amplifier feedback scheme implemented on a PCB (Printed Circuit Board). On the same board, a microcontroller-based frequency measurement circuit is also implemented, which is able to count the square wave fronts of the MEMS oscillator output with a resolution of 20 nsec. The system provides a frequency noise of 0.2 Hz corresponding to an extension resolution of 4 nm for the extensometer. Nearly perfect temperature compensation of the frequency output is achieved in the temperature range 20-35 C using the reference sensor. © 2011 IEEE.
Resumo:
We report enhanced reflection displayed by arrays of silicon based inverted nanocones. Theoretical studies suggest that such arrays display enhanced reflection and photonic band gaps within the optical and near infrared regions. Measured results show three to four fold enhancement in reflection and agree well with calculations. Such arrays can be used to enhance infrared reflection in photovoltaic devices which mostly contribute towards heating. © 2011 American Institute of Physics.
Resumo:
Supply chain tracking information is one of the main levers for achieving operational efficiency. RFID technology and the EPC Network can deliver serial-level product information that was never before available. However, these technologies still fail to meet the managers' visibility requirements in full, since they provide information about product location at specific time instances only. This paper proposes a model that uses the data provided by the EPC Network to deliver enhanced tracking information to the final user. Following a Bayesian approach, the model produces realistic ongoing estimates about the current and future location of products across a supply network, taking into account the characteristics of the product behavior and the configuration of the data collection points. These estimates can then be used to optimize operational decisions that depend on product availability at different locations. The enhancement of tracking information quality is highlighted through an example. © 2009 IFAC.