995 resultados para radiation scattering


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Irradiated polyamide-1010 (PA1010) and PA1010 containing 0.5% (wt) heterogeneous nuclei were studied by ESR, WAXD, DSC and the determination of gel fractions. The fold surface of the lamellae plays an important role in the effects of radiation on crystalline PA1010. The results show that the direct radiation effects on both samples vary, while after being heated to 220 degrees C, the final radiation effects are identical, regardless of the difference in the amount of the fold surface of the lamellae. The post-radiation effects result predominantly from the fold surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Five different molecular weight phenolphthalein poly(aryl ether ketone) (PEK-C) fractions in CHCl3 were studied by static and dynamic laser light scattering(LLS). The dynamic LLS revealed that the PEK-C samples contain some large polymer clusters. These large clusters can be removed by filtering the solution with a 0.1-mu m filter. We found that the persistence length of PEK-C in CHCl3 at 25 degrees C is similar to 2 nm and the Flory characteristic ratio, C-infinity is similar to 25. Our results showed that [R(g)(2)](1/2)(z) = (3.50+/-0.20) x 10(-2)M(w)(0.54+/-0.01) and [D] = (2.37+/-0.05) x 10(-4)M(w)(-0.55+/-0.01), with [R(g)(2)](1/2)(z), M(w), and [D] being the z-average radius of gyration, the weight-average molecular weight, and the z-average translational diffusion coefficient, respectively. A combination of static and dynamic LLS results enabled us to determine D = (2.20+/-0.10) x 10(-4)M(-0.555+/-0.015), where D and M correspond to monodisperse species. Using this calibration between D and M,we have determined molecular weight distributions of five PEK-C fractions from their corresponding translational diffusion coefficient distribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The chemiluminescence (CL) emission from three kinds of polyethylene, HDPE, LLDPE and LDPE, which had been exposed to 80 kGy dose from Co-60 in both air and nitrogen, has been examined. CL measurement was done under both nitrogen and oxygen atmosphere. The results show that the CL emission from irradiated samples does not result from irradiation itself, but from the oxidation reactions occurring during and after irradiation. Addition of 1 phr of an antioxidant, Irganox 1010, can effectively inhibit the radiation induced oxidation in LLDPE and LDPE. In the case of HDPE, however, it was found that pure HDPE has the best resistance to radiation-induced oxidation of the polymers examined in this work. However, incorporation of Irganox 1010 was found to have not only a stabilizing effect against radiation induced oxidation, but also to promote the oxidation in some cases.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the present work we attempt to settle the controversy on the district wherein the radiation induced reaction preferentially occurs through examining the structural changes of the irradiated polyamide-1010 specimens on both the crystallographic and the supermolecular level by using WAXD and SAXS techniques. Experimental results indicated that the chain crosslinking and scission of the irradiated specimens occur mainly in the amorphous region and on the crystal surface (or interphase), and extend into the inner portion of the crystal with increasing radiation dose.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The structural parameters of the aggregated state in the polyamide PA1010 and N,N'-bismaleimide-4,4'-diphenyl methane (BMI) system were computed by means of the desmearing intensity from SAXS and using the concept of the distance distribution function. The results revealed that the parameters Q, I(0), l(c) and L decreased with the increase BMI component, whereas O-s increased. The particle dimension Z for different BMI contents was less than 13.2 nm, and the maximum value of the distance distribution function P(Z) was found to be in the range Z = 6.5-7.0 nm.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A set of AM-AA copolymer samples with the same comonomer content and different average molecular weight have been characterized by C-13 NMB and light scattering methods in this paper. The chemical composition (comonomer AA, mole content 16.9 +/- 1.1%) of these samples is uniform. the sequence of AA in the macromolecular chain is of alone and random distribution and the light scattering theory from polyelectrolyte in added-salt solutions is suitable for the AM-AA copolymers-0.12 mol/L NaCl water systems. The actual values of M(w), the second Virial coefficient A(2) and the mean square radius of gyration (R(2)), for the studied samples have been obtained. The relationships between the molecular parameters are as follows: A(2)=0.0619 ($) over bar M(w)(-0.24), < R(2) >(1/2)(t)= 0.0210 ($) over bar M(w)(0.54).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The solution behavior of four chitosans (91% deacetylated chitin) with different molecular weights in 0.2M CH3COOH/0.1M CH3COONa aqueous solution was investigated at 25 degrees C by dynamic laser light scattering (LLS). The Laplace inversion of the precisely measured intensity-intensity time correlation function leads us to an estimate of the line-width distribution G(Gamma), which could be further reduced to a translational diffusion coefficient distribution G(D). By using a combination of static and dynamic LLS results, i.e. Mw and G(D), we were able to establish a calibration of D = k(D)M(-alpha D) with k(D) = (3.14 +/- 0.20) X 10(-4) and alpha(D) = 0.655 +/- 0.015. By using this calibration, we successfully converted G(D) into a molecular weight distribution f(w)(M). The larger alpha(D) value confirms that the chitosan chain is slightly extended in aqueous solution even in the presence of salts. This is mainly due to its backbone and polyelectrolytes nature. As a very sensitive technique, our dynamic LLS results also revealed that even in dilute solution chitosan still forms a small amount of larger sized aggregates that have ben overlooked in previous studies. The calibration obtained in this study will provide another way to characterize the molecular weight distribution of chitosan in aqueous solution at room temperature. (C) 1995 John Wiley & Sons, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aimed at raising the room temperature ionic conductivity of PEO-based solid polymer electrolyte and considered that the ionic conduction preferentially occurs in the amorphous phase, we lightly crosslinked the high MW PEO through gamma-irradiation and further suppressed the residual crystallinity by plasticizing with propylene carbonate. By incorporating LiClO4 salt to the above described polymer host, the ambient (25 degrees C) ionic conductivity of the electrolyte system could reach as high as 6.8 X 10(-4) S/cm. As the electrolyte was a crosslinked system, it was mechanically self-supportable. Based on the preliminary results of the electrochemical performance of the secondary lithium battery, assembled by using this kind of solid electrolyte and polyaniline as positive electrode, it is realized that the electrolyte thus prepared is of high expectancy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Radiation effects on polyamide-1010 specimens having various states of aggregation were studied using wide angle X-ray diffraction, electron spin resonance, calorific and sol measurement techniques. Experimental results indicated that chain crosslinking

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Raw polymer and compound of hydrogenated acrylonitrile butadiene rubber (HNBR) were subjected to gamma-ray irradiation. Crosslinking was found to be the main chemical reaction induced by irradiation; the ratio of chain scission to crosslinking as well as

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The interface thickness in two triblock copolymers were determined using small-angle x-ray scattering in the context of the theory proposed by Ruland. The thickness was found to be nonexistent for the samples at three different temperatures. By viewing th

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polytetrafluoroethylene (PTFE) has never been reported to form a network structure when subjected to high energy radiation. Results obtained in this work indicates that when irradiation is performed under 330-340-degrees-C in vacuo PTFE can be crosslinked

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Polytetrafluoroethylene (PTFE) is considered to be a typical radiation degradative polymer. In this work the polymer was crosslinked by means of radiation at 335 +/- 5-degrees-C under vacuum. Crosslinked PTFE showed a great improvement in high temperature

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In an attempt to explore the effects of structural multiplicity of polymers on the mechanism of radiation crosslinking, the adaptability of the Charlesby-Pinner's equation and its various modified versions are examined. It is recognized that both chemical

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Effect of hydrophobic oxide, containing =Si-CH=CH2 groups, on the radiation crosslinking of low density polyethylene (LDPE) has been studied. It was found that mechanical stability of irradiated LDPE containing improved SiO2 is higher than that of samples containing unimproved SiO2.