975 resultados para preparation method


Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: An LC-MS/MS method has been developed for the simultaneous quantification of P-glycoprotein (P-gp) and cytochrome P450 (CYP) probe substrates and their Phase I metabolites in DBS and plasma. P-gp (fexofenadine) and CYP-specific substrates (caffeine for CYP1A2, bupropion for CYP2B6, flurbiprofen for CYP2C9, omeprazole for CYP2C19, dextromethorphan for CYP2D6 and midazolam for CYP3A4) and their metabolites were extracted from DBS (10 µl) using methanol. Analytes were separated on a reversed-phase LC column followed by SRM detection within a 6 min run time. RESULTS: The method was fully validated over the expected clinical concentration range for all substances tested, in both DBS and plasma. The method has been successfully applied to a PK study where healthy male volunteers received a low dose cocktail of the here described P-gp and CYP probes. Good correlation was observed between capillary DBS and venous plasma drug concentrations. CONCLUSION: Due to its low-invasiveness, simple sample collection and minimal sample preparation, DBS represents a suitable method to simultaneously monitor in vivo activities of P-gp and CYP.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The 2009 International Society of Urological Pathology Consensus Conference in Boston made recommendations regarding the standardization of pathology reporting of radical prostatectomy specimens. Issues relating to the handling and processing of radical prostatectomy specimens were coordinated by working group 1. Most uropathologists followed similar procedures for fixation of radical prostatectomy specimens, with 51% of respondents transporting tissue in formalin. There was also consensus that the prostate weight without the seminal vesicles should be recorded. There was consensus that the surface of the prostate should be painted. It was agreed that both the prostate apex and base should be examined by the cone method with sagittal sectioning of the tissue sample. There was consensus that the gland should be fully fixed before sectioning. Both partial and complete embedding of prostates was considered to be acceptable as long as the method of partial embedding is stated. No consensus was determined regarding the necessity of weighing and measuring the length of the seminal vesicles, the preparation of whole mounts rather than standardized blocks and the methodology for sampling of fresh tissue for research purposes, and it was agreed that these should be left to the discretion of the working pathologist.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Workers performing preparation and administration of radiopharmaceuticals in NM departments are likely to receive high local skin doses to the hands which may even surpass the dose limit of 500 mSv whenever radiation protection standards are insufficient. A large measurement campaign was organised within the framework of the ORAMED project to determine the dose distribution across the hands received during preparation and administration of 18F- and 99mTc-labelled radiopharmaceuticals. The final data, collected over almost 3 years, include 641 measurements from 96 workers in 30 NM departments from 6 European countries. Results have provided levels of reference doses for the considered standard NM diagnostic procedures (mean maximum normalised skin dose of 230 μSv/GBq, 430 μSv/GBq, 930 μSv/GBq and 1200 μSv/GBq for the administration of 99mTc, preparation of 99mTc, administration of 18F and preparation of 18F, respectively). Finger dose was analysed as a function of the potential parameters of influence showing that shielding is the most efficient means of radiation protection to reduce skin dose. An appropriate method for routine monitoring of the extremities is also proposed: the base of the index finger of the non-dominant hand is a suitable position to place the ring dosemeter, with its sensitive part oriented towards the palm side; its reading may be multiplied by a factor of 6 to estimate the maximum local skin dose. Finally, results were compared to earlier published data, which correspond mostly to individual works with a reduced number of workers and measurements.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel approach to measure carbon dioxide (CO2) in gaseous samples, based on a precise and accurate quantification by (13)CO2 internal standard generated in situ is presented. The main goal of this study was to provide an innovative headspace-gas chromatography-mass spectrometry (HS-GC-MS) method applicable in the routine determination of CO2. The main drawback of the GC methods discussed in the literature for CO2 measurement is the lack of a specific internal standard necessary to perform quantification. CO2 measurement is still quantified by external calibration without taking into account analytical problems which can often occur considering gaseous samples. To avoid the manipulation of a stable isotope-labeled gas, we have chosen to generate in situ an internal labeled standard gas ((13)CO2) on the basis of the stoichiometric formation of CO2 by the reaction of hydrochloric acid (HCl) with sodium hydrogen carbonate (NaH(13)CO3). This method allows a precise measurement of CO2 concentration and was validated on various human postmortem gas samples in order to study its efficiency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intraoperative cardiac imaging plays a key role during transcatheter aortic valve replacement. In recent years, new techniques and new tools for improved image quality and virtual navigation have been proposed, in order to simplify and standardize stent valve positioning and implantation. But routine performance of the new techniques may require major economic investments or specific knowledge and skills and, for this reason, they may not be accessible to the majority of cardiac centres involved in transcatheter valve replacement projects. Additionally, they still require injections of contrast medium to obtain computed images. Therefore, we have developed and describe here a very simple and intuitive method of positioning balloon-expandable stent valves, which represents the evolution of the 'dumbbell' technique for echocardiography-guided transcatheter valve replacement without angiography. This method, based on the partial inflation of the balloon catheter during positioning, traps the crimped valve in the aortic valve orifice and, consequently, very near to the ideal landing zone. It does not require specific echocardiographic knowledge; it does not require angiographies that increase the risk of postoperative kidney failure in elderly patients, and it can be also performed in centres not equipped with a hybrid operating room.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An ELISA Inhibition Method (EIM) was proposed for the serologic diagnosis of dengue, comparing its results with the Hemagglutination Inhibition (HI) and the IgM capture-ELISA (MAC-ELISA). Advantages and disadvantages of both methods are discussed according to sensitivity, specificity, performance and usefulness. As a conclusion we recommend the complementary inclusion of the EIM and MAC-ELISA substituting the HI for laboratories engaged in the diagnosis and surveillance of dengue.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A rapid and simple technique for the purification of Toxoplasma gondii tachyzoites was developed. Highly purified parasites were obtained from the peritoneal exudates of infected mice by means of two consecutive discontinous sucrose gradients run at low speed (10,000xg, 30 min). Parasites obtained by this method conserved its biological activity. Hybridizations tudies with DNA from healthy mice and from purified tachyzoites preparations demonstrated that Toxoplasma gondii tachyzoites DNA could be obtained with better than 90 per cents purity. Preliminary studies with DNA endonucleases showed the presence in the tachyzoites genome of highly repetitives sequences.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dacron (polyethylenetherephthalate) is proposed as a matrix for dot-ELISA procedures, as an alternative to nitrocellulose. Plates of dacron were partially hydrazinolyzed and hydrazide groups introduced were converted to azide groups. The derivative dacron-antigen was covalently linked on to the plates through these azide groups. The derivative dacron-antigen was exaustively washed according to CROOK and antigen was still fixed onto the plates. Protein F1A purified from Yersinia pestis was used as a model. Triration of sera from immunized and non immunized rabbits against this protein was carried out by employing the dot-ELISA method. No significant difference was observed using dacron-antigen and nitrocellulose-antigen preparations. However, both procedures showed to have a significant better performance in comparasion with the passive hemagglutination method. The specificity and reproductibility of the dot-ELISA assay using both preparations showed a similar behaviour. Nitrocellulose preparation was stable at 4ºC, 28ºC and -20ºC for 90 days, whereas the dacron-antigen derivative was stable only when stored at 4ºC. Dacron-antigen derivative could be re-used when the spot developing was proceeded using 4-chloro-1-naphtol as substrate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Matrix effects, which represent an important issue in liquid chromatography coupled to mass spectrometry or tandem mass spectrometry detection, should be closely assessed during method development. In the case of quantitative analysis, the use of stable isotope-labelled internal standard with physico-chemical properties and ionization behaviour similar to the analyte is recommended. In this paper, an example of the choice of a co-eluting deuterated internal standard to compensate for short-term and long-term matrix effect in the case of chiral (R,S)-methadone plasma quantification is reported. The method was fully validated over a concentration range of 5-800 ng/mL for each methadone enantiomer with satisfactory relative bias (-1.0 to 1.0%), repeatability (0.9-4.9%) and intermediate precision (1.4-12.0%). From the results obtained during validation, a control chart process during 52 series of routine analysis was established using both intermediate precision standard deviation and FDA acceptance criteria. The results of routine quality control samples were generally included in the +/-15% variability around the target value and mainly in the two standard deviation interval illustrating the long-term stability of the method. The intermediate precision variability estimated in method validation was found to be coherent with the routine use of the method. During this period, 257 trough concentration and 54 peak concentration plasma samples of patients undergoing (R,S)-methadone treatment were successfully analysed for routine therapeutic drug monitoring.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Iron deficiency is a common and undertreated problem in inflammatory bowel disease (IBD). AIM: To develop an online tool to support treatment choice at the patient-specific level. METHODS: Using the RAND/UCLA Appropriateness Method (RUAM), a European expert panel assessed the appropriateness of treatment regimens for a variety of clinical scenarios in patients with non-anaemic iron deficiency (NAID) and iron deficiency anaemia (IDA). Treatment options included adjustment of IBD medication only, oral iron supplementation, high-/low-dose intravenous (IV) regimens, IV iron plus erythropoietin-stimulating agent (ESA), and blood transfusion. The panel process consisted of two individual rating rounds (1148 treatment indications; 9-point scale) and three plenary discussion meetings. RESULTS: The panel reached agreement on 71% of treatment indications. 'No treatment' was never considered appropriate, and repeat treatment after previous failure was generally discouraged. For 98% of scenarios, at least one treatment was appropriate. Adjustment of IBD medication was deemed appropriate in all patients with active disease. Use of oral iron was mainly considered an option in NAID and mildly anaemic patients without disease activity. IV regimens were often judged appropriate, with high-dose IV iron being the preferred option in 77% of IDA scenarios. Blood transfusion and IV+ESA were indicated in exceptional cases only. CONCLUSIONS: The RUAM revealed high agreement amongst experts on the management of iron deficiency in patients with IBD. High-dose IV iron was more often considered appropriate than other options. To facilitate dissemination of the recommendations, panel outcomes were embedded in an online tool, accessible via http://ferroscope.com/.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The use of Geographic Information Systems has revolutionalized the handling and the visualization of geo-referenced data and has underlined the critic role of spatial analysis. The usual tools for such a purpose are geostatistics which are widely used in Earth science. Geostatistics are based upon several hypothesis which are not always verified in practice. On the other hand, Artificial Neural Network (ANN) a priori can be used without special assumptions and are known to be flexible. This paper proposes to discuss the application of ANN in the case of the interpolation of a geo-referenced variable.