984 resultados para opto-electronic materials
Resumo:
PURPOSE: To investigate the ability of inversion recovery ON-resonant water suppression (IRON) in conjunction with P904 (superparamagnetic nanoparticles which consisting of a maghemite core coated with a low-molecular-weight amino-alcohol derivative of glucose) to perform steady-state equilibrium phase MR angiography (MRA) over a wide dose range. MATERIALS AND METHODS: Experiments were approved by the institutional animal care committee. Rabbits (n = 12) were imaged at baseline and serially after the administration of 10 incremental dosages of 0.57-5.7 mgFe/Kg P904. Conventional T1-weighted and IRON MRA were obtained on a clinical 1.5 Tesla (T) scanner to image the thoracic and abdominal aorta, and peripheral vessels. Contrast-to-noise ratios (CNR) and vessel sharpness were quantified. RESULTS: Using IRON MRA, CNR and vessel sharpness progressively increased with incremental dosages of the contrast agent P904, exhibiting constantly higher contrast values than T1 -weighted MRA over a very wide range of contrast agent doses (CNR of 18.8 ± 5.6 for IRON versus 11.1 ± 2.8 for T1 -weighted MRA at 1.71 mgFe/kg, P = 0.02 and 19.8 ± 5.9 for IRON versus -0.8 ± 1.4 for T1-weighted MRA at 3.99 mgFe/kg, P = 0.0002). Similar results were obtained for vessel sharpness in peripheral vessels, (Vessel sharpness of 46.76 ± 6.48% for IRON versus 33.20 ± 3.53% for T1-weighted MRA at 1.71 mgFe/Kg, P = 0.002, and of 48.66 ± 5.50% for IRON versus 19.00 ± 7.41% for T1-weighted MRA at 3.99 mgFe/Kg, P = 0.003). CONCLUSION: Our study suggests that quantitative CNR and vessel sharpness after the injection of P904 are consistently higher for IRON MRA when compared with conventional T1-weighted MRA. These findings apply for a wide range of contrast agent dosages.
Resumo:
Les fractures du condyle externe de l'enfant sont un traumatisme relativement fréquent qui survient le plus souvent chez l'enfant entre 5 et 15 ans. Elles sont classées en 3 grades : le grade 1 sans déplacement qui peuvent être traitées conservativement et les grades 2 (déplacées) et 3 (disloquées) qui nécessitent une prise en charge chirurgicale par réduction ouverte et embrochage. Le traitement traditionnel de ces fractures consistent en la mise en place de broches/vis métalliques qui doivent être retirées quelques semaines plus tard lors d'une seconde intervention. Depuis les années 90, des matériaux bio-résorbables à base d'acide polyglycoliques sont apparus en chirurgie orthopédique et traumatologique. En raison de la survenue de complications telles que réactions inflammatoires, formation de séromes ou ostéolyse, l'utilisation du matériel conventionnel a été préférée. Cependant, depuis quelques années, de nouveaux matériaux en acide polylactique sont apparus sur le marché. La période de résorption étant beaucoup plus lente, ces matériaux induisent des réactions beaucoup plus faibles, sans conséquences cliniques relevées jusqu'à présent. Chez l'adulte, de récentes études ont prouvés l'efficacité et l'absence d'effets secondaires liés à ces matériaux. Par contre, chez l'enfant, peu d'études à moyen terme ont été réalisées et l'impact sur l'os en croissance est peu connu, même si pour l'heure aucune conséquence clinique n'a été relevée. Dans le cadre de notre étude, nous avons comparé 2 groupes d'enfants traités pour des fractures du condyle externe du coude. Le premier groupe traité par du matériel conventionnel et le second par matériel résorbable. Les enfants ont tous étés suivis de manière très étroite durant la première année et la récupération clinique est similaire pour les 2 groupes. A 4 ans du traumatisme, les résultats fonctionnels sont identiques pour les 2 groupes et aucune complication liée au matériel résorbable n'a été mise en évidence. Par ailleurs, à 1 et 4 ans, les clichés radiologiques montrent l'absence de lésions liées au matériel résorbable. En conclusion, dans le cadre de notre travail nous avons pu montrer l'efficacité des matériaux résorbables dans la prise en charge des fractures du condyle externe du coude chez l'enfant. Ces matériaux permettent d'optimiser la prise en charge de ce type de fracture en prévenant un risque opératoire et anesthésique liés à une seconde intervention nécessaire au retrait du matériel d'ostéosynthèse conventionnel. Par ailleurs le coût lié à la prise en charge globale de ce type de fracture est moindre lors de l'utilisation de matériel résorbable.
Resumo:
Introduction and objectives: The AMS 800TM is considered the gold standard for sphincter replacement. However, the one-ring design can erode the urethra and lead to severe complications. A mechanism that could alternatively compress successive segments of the urethra would limit such deleterious outcome. We report 12 weeks animal urethral tissue analysis following implantation of a new modular artificial sphincter. METHODS: The device is composed by three parts: the contractile unit, two rings and an integrated microprocessor. The contractile unit is made of Nitinol fibers. The rings are placed around the urethra to control the flow of urine by squeezing the urethra. They work in a sequential alternative mode and are controlled by a microprocessor connected to an external computer. The computer can reveal specific failure of device components. The device was impkanted in eight male sheep. The rings were positioned around the urethra and the control unit was placed 5cm away. The device was working twenty hours per day; it was open 10min. per hour to allow urination. The animals were sacrificed after 12 weeks. The urethra and the tissues surrounding the control unit were macroscopically and microscopically examined. Two transversal sections crossing the sphincter and two transversal sections crossing the urethra alone were obtained and stained with modified Paragon after resin embedding. Urethra was also embedded in paraffin. The first section was stained with safranin-hematoxylin-eosin, the second section was stained with Masson's Trichrome and the remaining eight sections were available for immunolabelling of the macrophages.Results: The chronic study went uneventful. No clinical infection or pain was observed. The computer registered no specific failure in ring function, Nitinol wires and tube connectors. At explantation, except for a slight grade of lymphocytes in two out of eight specimens, no urethral stricture or atrophy could be observed. Immunohistochemistry confirmed the absence of macrophages. Tissue structure and organization of the urethra with and without artificial sphincter were similar. No migration of the device was observed.Conclusions: The study clearly showed no tissue damage or inflammation of the urethra. Electronic design, preservation of urethral vascularisation and adjustability after implantation are the key ideas to improve the actual AUS. Further studies will be carried out to evaluate this potential.
Resumo:
PURPOSE: To implement and characterize a fluorine-19 ((19)F) magnetic resonance imaging (MRI) technique and to test the hypothesis that the (19)F MRI signal in steady state after intravenous injection of a perfluoro-15-crown-5 ether (PCE) emulsion may be exploited for angiography in a pre-clinical in vivo animal study. MATERIALS AND METHODS: In vitro at 9.4T, the detection limit of the PCE emulsion at a scan time of 10 min/slice was determined, after which the T(1) and T(2) of PCE in venous blood were measured. Permission from the local animal use committee was obtained for all animal experiments. 12 µl/g of PCE emulsion was intravenously injected in 11 mice. Gradient echo (1)H and (19)F images were obtained at identical anatomical levels. Signal-to-noise (SNR) and contrast-to-noise (CNR) ratios were determined for 33 vessels in both the (19)F and (1)H images, which was followed by vessel tracking to determine the vessel conspicuity for both modalities. RESULTS: In vitro, the detection limit was ∼400 µM, while the (19)F T(1) and T(2) were 1350±40 and 25±2 ms. The (19)F MR angiograms selectively visualized the vasculature (and the liver parenchyma over time) while precisely coregistering with the (1)H images. Due to the lower SNR of (19)F compared to (1)H (17±8 vs. 83±49, p<0.001), the (19)F CNR was also lower at 15±8 vs. 52±35 (p<0.001). Vessel tracking demonstrated a significantly higher vessel sharpness in the (19)F images (66±11 vs. 56±12, p = 0.002). CONCLUSION: (19)F magnetic resonance angiography of intravenously administered perfluorocarbon emulsions is feasible for a selective and exclusive visualization of the vasculature in vivo.
Resumo:
El DLM-Forum on Electronic Records és un fòrum internacional multidisciplinari, organitzat per la Comissió Europea, que té per objectiu impulsar els projectes per a la millora de la gestió dels documents electrònics en les organitzacions i per a la conservació d'aquests a llarg termini. Al mateix temps, el DLM-Forum esdevé un punt de referència bàsic per a la coordinació de les polítiques de gestió dels documents electrònics que es porten a terme als estats membres de la Unió Europea, per a l'establiment d'estàndards de gestió i de conservació a escala comunitària, i per a la implicació dels agents del sector privat en la recerca de solucions a la problemàtica dels documents electrònics. El present informe exposa l'origen d'aquesta iniciativa, en descriu les dues edicions celebrades fins ara i les perspectives de futur del fòrum.
Resumo:
L'explosió de la informació digital en les col·leccions bibliotecàries d'aquesta dècada passada ens ha ofert molts beneficis, especialment en relació al seu accés, emmagatzematge i ús. No obstant això, queden tota una sèrie de qüestions referents a la preservació a llarg termini d'aquests materials que encara no tenen resposta. Aquest article explora alguns dels aspectes principals, com ara les pròpies dades que cal preservar; les amenaces derivades de l'obsolescència dels mitjans físics d'emmagatzematge, els formats, el programari i el maquinari; les tècniques proposadesmactualment per a la preservació a llarg termini; la importància de conservar també les metadades, i els tipus d'institucions que estan implicades -o que haurien d'estar-hi- en la cerca de les solucions necessàries.
Resumo:
El desenvolupament dels recursos electrònics d¿accés remot, amb unes característiques ben diferents dels materials que tradicionalment han omplert els prestatges de les biblioteques, ha accelerat la revisió de les normatives de descripció i de catalogació i dels principis mateixos en què es basen. Es repassa l¿estat actual de la revisió de les normes pel que fa a les publicacions seriades i es comenten alguns problemes del tractament catalogràfic deles revistes en línia.
Resumo:
A hazardous materials accident can occur anywhere. Communities located near chemical manufacturing plants are particularly at risk. However, hazardous materials are transported on our roadways, railways and waterways daily, so any area is considered vulnerable to an accident.
Resumo:
Los más viejos del lugar recordarán con nostalgia los repertorios clásicos de fuentes de información elaborados por Malclès y Sabor... A los no tan viejos les sonarán los nombres de Sheehy (o Balay) y Walford
Resumo:
El treball analitza com organitzen l'accés a les col·leccions de revistes electròniques les biblioteques universitàries catalanes. En concret, s'examina l'existència de pàgines web de revistes electròniques, l'organització, les polítiques d'inclusió d'aquests materials en el catàleg així com els procediments catalogràfics aplicats.
Resumo:
El pasado mes de junio se celebró en Pittsburgh, EE.UU., el duodécimo simposio internacional sobre tesis electrónicas: Electronic Thesis and Dissertations Conference (ETD2009). Fue organizado por Networked Digital Library of Theses and Dissertations (NDLTD). La mayoría de los ponentes explicaron las experiencias de su propia universidad. Además, hubo expertos invitados entre los cuales se pueden destacar Stevan Harnad (Univ. Southampton), Karla Hahn (Association of Research Libraries) y Deanna Marcum (Library of Congress). Estos simposios pretenden promover la adopción, creación, uso, difusión y preservación de las tesis electrónicas. De hecho, el éxito ha sido tal, que algunas universidades ya prescinden de la copia en papel para el depósito y preservación del documento. Un caso reciente es el de la University of Albany cuya nueva política, anunciada durante el simposio, consiste en que a partir de setiembre del 2009 ya no requiere el depósito de una copia impresa de las tesis aprobadas en aquella universidad.
Resumo:
The recent surge in scientific electronic journals began when libraries began having access to the WWW in the mid-1990s. The shift from paper to digital has affected the traditional alignment and role of the primary "stakeholders" -mainly authors, publishers, universities and libraries. The author offers a brief review of the history of the scholarly journal followed by the evolution of e-journals in during the past two decades. The article then focuses on the implications that these have had on traditional library processes and services such as selection, acquisitions, cataloguing, storage, preservation and user services. In the conclusion the author speculates on the long term effect of Web-based publishing on the format of the traditional scholarly journal as it has existed for over 300 years.
Resumo:
The aim of this paper is to expand on previous quantitative and qualitative research into the use of electronic information resources and its impact on the information behaviour of academics at Catalan universities.
Resumo:
A qualitative study of the impact of electronic journals on the information behavior of academics at Catalan universities shows that academics now read more, and more widely. However, their reading is becoming more superficial; they are compelled to improve their discrimination skills in order to decide what to read in more depth. The electronic accessibility of journals means that academics now make fewer library visits. Web browsing and TOC e-mail alerts are replacing physical browsing, and searching is a very popular option for keeping up to date with developments. Internet search engines, especially Google and Google Scholar, are becoming important sources of information for academics. However, they face problems in managing their personal scientific information.
Resumo:
Del 6 al 8 de maig de 2002 es va celebrar a Barcelona la tercera edició del DLM-Forum on Electronic Records, el fòrum internacional multidisciplinari que té per objectiu la millora de la gestió dels documents electrònics a les organitzacions i conservació a llarg termini. Aquesta edició ha estat marcada per una participació més activa de la indústria de les tecnologies de la informació i de les comunicacions, i per la presentació dels resultats d'iniciatives del DLM-Forum 1996. El present informe descriu la gènesi i el desenvolupament del DLM-Forum de Barcelona, i n'indica els assoliments més remarcables.