989 resultados para network analyzer measurement
Resumo:
Termed the “silent epidemic,” traumatic brain injury (TBI) is the most debilitating outcome of injury, and is characterized by the irreversibility of its damages, long-term effects on quality of life and healthcare costs. The latest data available from the CDC estimate that nationally, 52,000 people die each year from TBI2. In Iowa, TBI is a major public health problem. The numbers and rates of hospitalizations and emergency department (ED) visits due to TBIs are steadily increasing. From 2006 to 2008, there were on average 545 injury deaths per year. Among the injured Iowans, TBI constituted nearly 30 percent (545) of all injury deaths, ten percent (1,591) of people hospitalized and seven percent (17,696) of ED visitors. 3 The state of Iowa has been supporting secondary prevention services to TBI survivors for several years. An Iowa organization that has made a significant effort in assisting TBI survivors is the Brain Injury Association of Iowa (BIAIA). The BIAIA administers the IBIRN program in cooperation with the Iowa Department of Public Health (IDPH) through HRSA TBI Implementation grant funding and state appropriations.
Resumo:
This brochure states the mission of the Early Childhood Network along with contact names and addresses of the specialists and consultants in the Iowa Department of Education and the Iowa Area Education Agencies for the years 2005/2006.
Resumo:
The centrifugal liquid membrane (CLM) cell has been utilized for chiroptical studies of liquid-liquid interfaces with a conventional circular dichroism (CD) spectropolarimeter. These studies required the characterization of optical properties of the rotating cylindrical CLM glass cell, which was used under the high speed rotation. In the present study, we have measured the circular and linear dichroism (CD and LD) spectra and the circular and linear birefringence (CB and LB) spectra of the CLM cell itself as well as those of porphyrine aggregates formed at the liquid-liquid interface in the CLM cell, applying Mueller matrix measurement method. From the results, it was confirmed that the CLM-CD spectra of the interfacial porphyrin aggregates observed by a conventional CD spectropolarimeter should be correct irrespective of LD and LB signals in the CLM cell.
Resumo:
Genetically constructed microbial biosensors for measuring organic pollutants are mostly applied in aqueous samples. Unfortunately, the detection limit of most biosensors is insufficient to detect pollutants at low but environmentally relevant concentrations. However, organic pollutants with low levels of water solubility often have significant gas-water partitioning coefficients, which in principle makes it possible to measure such compounds in the gas rather than the aqueous phase. Here we describe the first use of a microbial biosensor for measuring organic pollutants directly in the gas phase. For this purpose, we reconstructed a bioluminescent Pseudomonas putida naphthalene biosensor strain to carry the NAH7 plasmid and a chromosomally inserted gene fusion between the sal promoter and the luxAB genes. Specific calibration studies were performed with suspended and filter-immobilized biosensor cells, in aqueous solution and in the gas phase. Gas phase measurements with filter-immobilized biosensor cells in closed flasks, with a naphthalene-contaminated aqueous phase, showed that the biosensor cells can measure naphthalene effectively. The biosensor cells on the filter responded with increasing light output proportional to the naphthalene concentration added to the water phase, even though only a small proportion of the naphthalene was present in the gas phase. In fact, the biosensor cells could concentrate a larger proportion of naphthalene through the gas phase than in the aqueous suspension, probably due to faster transport of naphthalene to the cells in the gas phase. This led to a 10-fold lower detectable aqueous naphthalene concentration (50 nM instead of 0.5 micro M). Thus, the use of bacterial biosensors for measuring organic pollutants in the gas phase is a valid method for increasing the sensitivity of these valuable biological devices.
Resumo:
Kunnostusojitustarpeen ennustaminen ojitusalueilla
Resumo:
BACKGROUND: The renal enzyme renin cleaves from the hepatic alpha(2)-globulin angiotensinogen angiotensin-(1-10) decapeptide [Ang-(1-10)], which is further metabolized to smaller peptides that help maintain cardiovascular homeostasis. The Ang-(1-7) heptapeptide has been reported to have several physiological effects, including natriuresis, diuresis, vasodilation, and release of vasopressin and prostaglandins. METHODS: To investigate Ang-(1-7) in clinical settings, we developed a method to measure immunoreactive (ir-) Ang-(1-7) in 2 mL of human blood and to estimate plasma concentrations by correcting for the hematocrit. A sensitive and specific antiserum against Ang-(1-7) was raised in a rabbit. Human blood was collected in the presence of an inhibitor mixture including a renin inhibitor to prevent peptide generation in vitro. Ang-(1-7) was extracted into ethanol and purified on phenylsilylsilica. The peptide was quantified by radioimmunoassay. Increasing doses of Ang-(1-7) were infused into volunteers, and plasma concentrations of the peptide were measured. RESULTS: The detection limit for plasma ir-Ang-(1-7) was 1 pmol/L. CVs for high and low blood concentrations were 4% and 20%, respectively, and between-assay CVs were 8% and 13%, respectively. Reference values for human plasma concentrations of ir-Ang-(1-7) were 1.0-9.5 pmol/L (median, 4.7 pmol/L) and increased linearly during infusion of increasing doses of Ang-(1-7). CONCLUSIONS: Reliable measurement of plasma ir-Ang-(1-7) is achieved with efficient inhibition of enzymes that generate or metabolize Ang-(1-7) after blood sampling, extraction in ethanol, and purification on phenylsilylsilica, and by use of a specific antiserum.
Resumo:
Background: This study analyzed prognostic factors and treatment outcomes of primary thyroid lymphoma. Patients and Methods: Data were retrospectively collected for 87 patients (53 stage I and 34 stage II) with median age 65 years. Fifty-two patients were treated with single modality (31 with chemotherapy alone and 21 with radiotherapy alone) and 35 with combined modality treatment. Median follow-up was 51 months. Results: Sixty patients had aggressive lymphoma and 27 had indolent lymphoma. The 5- and 10-year overall survival (OS) rates were 74% and 71%, respectively, and the disease-free survival (DFS) rates were 68% and 64%. Univariate analysis revealed that age, tumor size, stage, lymph node involvement, B symptoms, and treatment modality were prognostic factors for OS, DFS, and local control (LC). Patients with thyroiditis had significantly better LC rates. In multivariate analysis, OS was influenced by age, B symptoms, lymph node involvement, and tumor size, whereas DFS and LC were influenced by B symptoms and tumor size. Compared with single modality treatment, patients treated with combined modality had better 5-year OS, DFS, and LC. Conclusions: Combined modality leads to an excellent prognosis for patients with aggressive lymphoma but does not improve OS and LC in patients with indolent lymphoma.
Resumo:
Report on the Iowa Communications Network (ICN) for the year ended June 30, 2012
Resumo:
High performance liquid chromatography (HPLC) is the reference method for measuring concentrations of antimicrobials in blood. This technique requires careful sample preparation. Protocols using organic solvents and/or solid extraction phases are time consuming and entail several manipulations, which can lead to partial loss of the determined compound and increased analytical variability. Moreover, to obtain sufficient material for analysis, at least 1 ml of plasma is required. This constraint makes it difficult to determine drug levels when blood sample volumes are limited. However, drugs with low plasma-protein binding can be reliably extracted from plasma by ultra-filtration with a minimal loss due to the protein-bound fraction. This study validated a single-step ultra-filtration method for extracting fluconazole (FLC), a first-line antifungal agent with a weak plasma-protein binding, from plasma to determine its concentration by HPLC. Spiked FLC standards and unknowns were prepared in human and rat plasma. Samples (240 microl) were transferred into disposable microtube filtration units containing cellulose or polysulfone filters with a 5 kDa cut-off. After centrifugation for 60 min at 15000g, FLC concentrations were measured by direct injection of the filtrate into the HPLC. Using cellulose filters, low molecular weight proteins were eluted early in the chromatogram and well separated from FLC that eluted at 8.40 min as a sharp single peak. In contrast, with polysulfone filters several additional peaks interfering with the FLC peak were observed. Moreover, the FLC recovery using cellulose filters compared to polysulfone filters was higher and had a better reproducibility. Cellulose filters were therefore used for the subsequent validation procedure. The quantification limit was 0.195 mgl(-1). Standard curves with a quadratic regression coefficient > or = 0.9999 were obtained in the concentration range of 0.195-100 mgl(-1). The inter and intra-run accuracies and precisions over the clinically relevant concentration range, 1.875-60 mgl(-1), fell well within the +/-15% variation recommended by the current guidelines for the validation of analytical methods. Furthermore, no analytical interference was observed with commonly used antibiotics, antifungals, antivirals and immunosuppressive agents. Ultra-filtration of plasma with cellulose filters permits the extraction of FLC from small volumes (240 microl). The determination of FLC concentrations by HPLC after this single-step procedure is selective, precise and accurate.
Resumo:
BACKGROUND: Positional therapy that prevents patients from sleeping supine has been used for many years to manage positional obstructive sleep apnea (OSA). However, patients' usage at home and the long term efficacy of this therapy have never been objectively assessed. METHODS: Sixteen patients with positional OSA who refused or could not tolerate continuous positive airway pressure (CPAP) were enrolled after a test night study (T0) to test the efficacy of the positional therapy device. The patients who had a successful test night were instructed to use the device every night for three months. Nightly usage was monitored by an actigraphic recorder placed inside the positional device. A follow-up night study (T3) was performed after three months of positional therapy. RESULTS: Patients used the device on average 73.7 ± 29.3% (mean ± SD) of the nights for 8.0 ± 2.0 h/night. 10/16 patients used the device more than 80% of the nights. Compared to the baseline (diagnostic) night, mean apnea-hypopnea index (AHI) decreased from 26.7 ± 17.5 to 6.0 ± 3.4 with the positional device (p<0.0001) during T0 night. Oxygen desaturation (3%) index also fell from 18.4 ± 11.1 to 7.1 ± 5.7 (p = 0.001). Time spent supine fell from 42.8 ± 26.2% to 5.8 ± 7.2% (p < 0.0001). At three months (T3), the benefits persisted with no difference in AHI (p = 0.58) or in time spent supine (p = 0.98) compared to T0 night. The Epworth sleepiness scale showed a significant decrease from 9.4 ± 4.5 to 6.6 ± 4.7 (p = 0.02) after three months. CONCLUSIONS: Selected patients with positional OSA can be effectively treated by a positional therapy with an objective compliance of 73.7% of the nights and a persistent efficacy after three months.
Resumo:
PURPOSE/OBJECTIVE(S): Primary bone lymphoma (PBL) represents less than 1% of all malignant lymphomas, and 4-5% of all extranodal lymphomas. In this study, we assessed the disease profile, outcome, and prognostic factors in patients with stage I and II PBL. MATERIALS/METHODS: Between 1987 and 2008, 116 consecutive patients with PBL treated in 13 RCNinstitutions were included in this study. Inclusion criteriawere: age.17 yrs, PBLin stage I and II, andminimum6months follow-up. The median agewas 51 yrs (range: 17-93).Diagnosticwork-up included plain boneXray (74%of patients), scintigraphy (62%), CT-scan (65%),MRI (58%), PET (18%), and bone-marrow biopsy (84%).All patients had biopsy-proven confirmation of non-Hodgkin's lymphoma (NHL). The histopathological type was predominantly diffuse large B-cell lymphoma (78%) and follicular lymphoma (6%), according to theWHOclassification. One hundred patients had a high-grade, 7 intermediate and 9 low-gradeNHL. Ninety-three patients had anAnn-Arbor stage I, and 23 had a stage II. Seventy-seven patients underwent chemoradiotherapy (CXRT), 12 radiotherapy (RT) alone, 10 chemotherapy alone (CXT), 9 surgery followed by CXRT, 5 surgery followed by CXT, and 2 surgery followed by RT. One patient died before treatment.Median RT dosewas 40Gy (range: 4-60).Themedian number ofCXTcycleswas 6 (range, : 2-8).Median follow-upwas 41months (range: 6-242). RESULTS: Following treatment, the overall response rate was 91% (CR 74%, PR 17%). Local recurrence was observed in 12 (10%) patients, and systemic recurrence in 17 (15%) patients. Causes of death included disease progression in 16, unrelated disease in 6, CXT-related toxicity in 1, and secondary cancer in 2 patients. The 5-yr overall survival (OS), disease-free survival (DFS), lymphoma- specific survival (LSS), and local control (LC) were 76%, 69%, 78%, and 92%, respectively. In univariate analyses (log-rank test), favorable prognostic factors for survival were: age\50 years (p = 0.008), IPI score #1 (p = 0.009), complete response (p\0.001), CXT (p = 0.008), number of CXT cycles $6 (p = 0.007), and RT dose . 40 Gy (p = 0.005). In multivariate analysis age, RT dose, complete response, and absence of B symptoms were independent factors influencing the outcome. There were 3 patients developing grade 3 or more (CTCAE.V3.0) toxicities. CONCLUSIONS: This large multicenter study, confirms the relatively good prognosis of early stage PBL, treated with combined CXRT. Local control was excellent, and systemic failure occurred infrequently. A sufficient dose of RT (. 40 Gy) and complete CXT regime (. 6 cycles) were associated with a better outcome. Combined modality appears to be the treatment of choice.