992 resultados para municipal sewage sludge
Resumo:
En aquest treball s'analitzen les característiques generals i particulars dels esfondraments per carstificació que esprodueixen al terme municipal de Besalú, i s'examinen les diferents dades que permeten establir una primera aproximació cartogràfica del perill existent
Resumo:
The general striving to bring down the number of municipal landfills and to increase the reuse and recycling of waste-derived materials across the EU supports the debates concerning the feasibility and rationality of waste management systems. Substantial decrease in the volume and mass of landfill-disposed waste flows can be achieved by directing suitable waste fractions to energy recovery. Global fossil energy supplies are becoming more and more valuable and expensive energy sources for the mankind, and efforts to save fossil fuels have been made. Waste-derived fuels offer one potential partial solution to two different problems. First, waste that cannot be feasibly re-used or recycled is utilized in the energy conversion process according to EU’s Waste Hierarchy. Second, fossil fuels can be saved for other purposes than energy, mainly as transport fuels. This thesis presents the principles of assessing the most sustainable system solution for an integrated municipal waste management and energy system. The assessment process includes: · formation of a SISMan (Simple Integrated System Management) model of an integrated system including mass, energy and financial flows, and · formation of a MEFLO (Mass, Energy, Financial, Legislational, Other decisionsupport data) decision matrix according to the selected decision criteria, including essential and optional decision criteria. The methods are described and theoretical examples of the utilization of the methods are presented in the thesis. The assessment process involves the selection of different system alternatives (process alternatives for treatment of different waste fractions) and comparison between the alternatives. The first of the two novelty values of the utilization of the presented methods is the perspective selected for the formation of the SISMan model. Normally waste management and energy systems are operated separately according to the targets and principles set for each system. In the thesis the waste management and energy supply systems are considered as one larger integrated system with one primary target of serving the customers, i.e. citizens, as efficiently as possible in the spirit of sustainable development, including the following requirements: · reasonable overall costs, including waste management costs and energy costs; · minimum environmental burdens caused by the integrated waste management and energy system, taking into account the requirement above; and · social acceptance of the selected waste treatment and energy production methods. The integrated waste management and energy system is described by forming a SISMan model including three different flows of the system: energy, mass and financial flows. By defining the three types of flows for an integrated system, the selected factor results needed in the decision-making process of the selection of waste management treatment processes for different waste fractions can be calculated. The model and its results form a transparent description of the integrated system under discussion. The MEFLO decision matrix has been formed from the results of the SISMan model, combined with additional data, including e.g. environmental restrictions and regional aspects. System alternatives which do not meet the requirements set by legislation can be deleted from the comparisons before any closer numerical considerations. The second novelty value of this thesis is the three-level ranking method for combining the factor results of the MEFLO decision matrix. As a result of the MEFLO decision matrix, a transparent ranking of different system alternatives, including selection of treatment processes for different waste fractions, is achieved. SISMan and MEFLO are methods meant to be utilized in municipal decision-making processes concerning waste management and energy supply as simple, transparent and easyto- understand tools. The methods can be utilized in the assessment of existing systems, and particularly in the planning processes of future regional integrated systems. The principles of SISMan and MEFLO can be utilized also in other environments, where synergies of integrating two (or more) systems can be obtained. The SISMan flow model and the MEFLO decision matrix can be formed with or without any applicable commercial or free-of-charge tool/software. SISMan and MEFLO are not bound to any libraries or data-bases including process information, such as different emission data libraries utilized in life cycle assessments.
Resumo:
Concurs d'idees d'un punt d'informació turística del Patronat municipal de turisme de Tarragona
Resumo:
The aim of this work was to study the influence of effluent organic matter (EfOM) on micropollutants removal by ozone and UV/H2O2. To perform the experiments, deionized water and municipal secondary effluents (SE) were artificially contaminated with atrazine (ATZ) and treated by the two proposed methods. ATZ concentration, COD and TOC were recorded along the reaction time and used to evaluate EfOM effect on the system efficiency. Results demonstrate that the presence of EfOM can significantly reduce the micropollutant removal rate due to competition of EfOM components to react with radicals and/or molecular ozone. The hydroxyl radical scavenging caused by EfOM was quantified as well as the contribution of molecular ozone and �OH radicals during the ozonation of SE. EfOM components promoted higher inhibition of ATZ oxidation by hydroxyl radicals than by molecular ozone.
Resumo:
Membrane bioreactors (MBRs) are a combination of activated sludge bioreactors and membrane filtration, enabling high quality effluent with a small footprint. However, they can be beset by fouling, which causes an increase in transmembrane pressure (TMP). Modelling and simulation of changes in TMP could be useful to describe fouling through the identification of the most relevant operating conditions. Using experimental data from a MBR pilot plant operated for 462days, two different models were developed: a deterministic model using activated sludge model n°2d (ASM2d) for the biological component and a resistance in-series model for the filtration component as well as a data-driven model based on multivariable regressions. Once validated, these models were used to describe membrane fouling (as changes in TMP over time) under different operating conditions. The deterministic model performed better at higher temperatures (>20°C), constant operating conditions (DO set-point, membrane air-flow, pH and ORP), and high mixed liquor suspended solids (>6.9gL-1) and flux changes. At low pH (<7) or periods with higher pH changes, the data-driven model was more accurate. Changes in the DO set-point of the aerobic reactor that affected the TMP were also better described by the data-driven model. By combining the use of both models, a better description of fouling can be achieved under different operating conditions
Resumo:
Occurrence and removal of 81 representative Pharmaceutical Active Compounds (PhACs) were assessed in a municipal WWTP located in a highly industrialized area, with partial water reuse after UV tertiary treatment and discharge to a Mediterranean river. Water monitoring was performed in an integrated way at different points in the WWTP and river along three seasons. Consistent differences between therapeutic classes were observed in terms of influent concentration, removal efficiencies and seasonal variation. Conventional (primary and secondary) treatment was unable to completely remove numerous compounds and UV-based tertiary treatment played a complementary role for some of them. Industrial activity influence was highlighted in terms of PhACs presence and seasonal distribution. Even if global WWTP effluent impact on the studied river appeared to be minor, PhACs resulted widespread pollutants in river waters. Contamination can be particularly critical in summer in water scarcity areas, when water flow decreases considerably
Resumo:
Two experimental studies evaluated the effect of aerobic and membrane aeration changes on sludge properties, biological nutrient removal and filtration processes in a pilot plant membrane bioreactor. The optimal operating conditions were found at an aerobic dissolved oxygen set-point (DO) of 0.5mgO2L-1 and a membrane specific aeration demand (SADm) of 1mh-1, where membrane aeration can be used for nitrification. Under these conditions, a total flow reduction of 42% was achieved (75% energy reduction) without compromising nutrient removal efficiencies, maintaining sludge characteristics and controlled filtration. Below these optimal operating conditions, the nutrient removal efficiency was reduced, increasing 20% for soluble microbial products, 14% for capillarity suction time and reducing a 15% for filterability. Below this DO set-point, fouling increased with a transmembrane pressure 75% higher. SADm below 1mh-1 doubled the values of transmembrane pressure, without recovery after achieving the initial conditions
Resumo:
Award-winning
Resumo:
This work presents a study about the elimination of anticancer drugs, a group of pollutants considered recalcitrant during conventional activated sludge wastewater treatment, using a biological treatment based on the fungus Trametes versicolor. A 10-L fluidized bed bioreactor inoculated with this fungus was set up in order to evaluate the removal of 10 selected anticancer drugs in real hospital wastewater. Almost all the tested anticancer drugs were completely removed from the wastewater at the end of the batch experiment (8 d) with the exception of Ifosfamide and Tamoxifen. These two recalcitrant compounds, together with Cyclophosphamide, were selected for further studies to test their degradability by T. versicolor under optimal growth conditions. Cyclophosphamide and Ifosfamide were inalterable during batch experiments both at high and low concentration, whereas Tamoxifen exhibited a decrease in its concentration along the treatment. Two positional isomers of a hydroxylated form of Tamoxifen were identified during this experiment using a high resolution mass spectrometry based on ultra-high performance chromatography coupled to an Orbitrap detector (LTQ-Velos Orbitrap). Finally the identified transformation products of Tamoxifen were monitored in the bioreactor run with real hospital wastewater
Resumo:
Els negocis relacionats amb les activitats de lleure i els esports d’aventura actualment es troben en expansió, buscant majoritàriament el contacte amb la natura. Les rutes a cavall formen part del gran ventall d’opcions, per aquesta qüestió s’ha pensat en construir un refugi utilitzat com a final d’etapa per a rutes a cavall. En la major part del territori, la presència de població humana es manifesta en pobles, viles i ciutats, les quals disposes d’aigua sanitària, corrent elèctric i sistema de clavegueram. Per altra banda en les urbanitzacions o cases aïllades poder gaudir d’aquests serveis suposa una inversió econòmica elevada, que implica la utilització de sistemes alternatius. En el present projecte s’ha triat un emplaçament on portar a terme el final d’etapa amb una sèrie de requisits a complir : bosc a les proximitats, disposar d’un o varis accessos per a vehicles (transport del material d’intendència), tranquil•litat, bones vistes, i cobertura de telèfon mòbil. S’han acceptat les següents limitacions : no disposar de xarxa pública d’electricitat ni d’aigua. I s’han dimensionat les instal•lacions per a un màxim de dotze persones i els seus respectius cavalls. El principal objectiu del projecte és el dimensionament de les necessitats elèctriques, d’aigua i d’aiguacalenta sanitària en condicions autònomes, i utilitzant energies renovables. La valoració de les possibles solucions per condicionar les instal•lacions, i oferir una resposta eficient per la demanda. No és un objectiu específic del treball la potabilització de l’aigua ni el tractament dels residus produïts. S’han aprofitat els diferents desnivells que presenta l’emplaçament triat a l’hora de distribuir les instal•lacions, i s’ha utilitzat un antic cobert de dos pisos ja existent. Com a residència s’ha triat un model de casa prefabricada de muntanya. Com a sistema de subministrament elèctric, s’instal•laran plaques solars fotovoltaiques i un generador de corrent com a sistema auxiliar. La captació d’aigua s’efectuarà a partir d’un pou que es troba en el terreny i de la recollida d el’aigua pluvial, instal•lant dipòsits d’emmagatzemament d’aigua segons les necessitats. S’utilitzarà un equip de cloració per potabilitzar l’aigua de consum utilitzada a la residència. En la producció d’aigua calenta sanitària s’utilitzaran plaques solars tèrmiques i una caldera instantània de gas propà com a suport. Per cuinar s’ha triat una cuina de gas propà i una barbacoa que s’instal•larà a l’exterior. S’instal•larà una llar de foc amb recuperador d’aire a la residència i una fosa sèptica amb un sistema d’infiltració per poder abocar les aigües provinents de la residència. Els fems dels cavalls podran ser utilitzats com adob pel terreny.
Resumo:
Inversors però, principalment professionals de l'àmbit agrari, per tal de buscar una diversificació de l'activitat agrícola i ramadera que desenvolupen a les seves finques, sobretot joves emprenedors, poden estar interessats en produccions alternatives com la producció d'ànecs per a foie-gras, per tal de complementar la seva renda agrària. Actualment cal augmentar la competitivitat de les finques agrícoles per tal que aquestes siguin econòmicament viables. L’objectiu de l'estudi és determinar la viabilitat econòmica d’una explotació ramadera d’ànecs per a la producció de foie-gras, en el terme municipal de Fontanals de Cerdanya, analitzant les diverses alternatives en quant a dimensionament i disseny de les instal·lacions, segons el cicle productiu de l’animal. L'alternativa escollida per realitzar l'estudi es la de semi-integració (cria, engreix i embocat), de règim semi-intensiu (durant l'etapa de l'engreix), amb animals mascles de la raça híbrida Mulard. Les instal·lacions tindran una capacitat de 6.500 animals, amb lots de 250 caps. Aquest dimensionament permet, durant la fase d'embocat, en la qual es requereix més dedicació, que la demanda de mà d'obra pugui ser satisfeta per un únic treballador. La principal conclusió que es pot extreure de l'estudi és que la inversió projectada és massa elevada i que aquesta econòmicament no és viable o rendible, ja que la despesa és massa elevada. Es mouen uns fluxos de caixa molt elevats i el marge comercial és molt reduït. Únicament si l'objectiu del promotor és obtenir una remuneració per la seva feina, sempre i quan és produeixi un augment del preu actual de la carn i una disminució del preu del pinso, es podria recomanar que es portés a terme la implantació de l'explotació, intentant, però, reduir la despesa d'execució de construccions i instal·lacions.
Resumo:
The influence of nitric-perchloric, aqua regia, dry ashing and microwave digestion methods, in combination with 100 and 200 mg of sample, on the characterization and recovery of nutrients in samples of sludge sewage, poultry, swine, quail and bovine manures, organic compost, organic substrate and humic material were studied. Nitric-perchloric digestion with 200 mg samples recovered the higher nutrient contents. The nitric-perchloric method recovered also low levels of K. Dry ashing caused S volatilization and microwave digestion produced dark color extracts and this impaired S determination. Aqua regia recovered the lowest contents of nutrients in the organic residues evaluated.
Resumo:
We performed a study on the specific composition, structure, and dynamics of two Cystoseira mediterranea communities from the north-western Mediterranean submitted to different degrees of pollution. The structural complexity (species richness, specific distribution, and species and pattern diversity) and biomass production were lower in the polluted site. In this station, opportunistic algae (mainly Ulva rigida) loomed, and Mesophyllum lichenoides and some encrusting brown algae increased their cover. Other species (Jania rubens, and some Ceramiales) decreased their abundance when compared with the polluted site
Resumo:
Estudi de la climatització d'una instal•lació esportiva,concretament una piscina coberta municipal, a partir de la calor recuperada de les aigües residuals urbanes (ARU) que produeix una població de 30.000 habitants. En la primera part de l'estudi s'ha calculat la potència màxima per cobrir les quatrenecessitats de la instal•lació en règim estacionari, que ha resultat ser de 265,8 kW,repartits en 69,1 kW per cobrir les necessitats del vas de la piscina, 102,5 kW percobrir les necessitats en l'aire interior de la sala de la piscina, 30,2 kW per cobrir lesnecessitats tèrmiques calorífiques de les sales annexes i 64 kW per cobrir lesnecessitats en la producció d'aigua calenta sanitària (ACS). A continuació també s'hadeterminat l'estimació de la despesa total anual de la instal•lació que és de 1.179MWh/any. El 48% aproximadament de la despesa total es destina a cobrir lesnecessitats del vas de la piscina, el 28% per cobrir la producció d'ACS, el 20% percobrir les necessitats de la sala de la piscina i el 4% per cobrir les necessitatscalorífiques a hivern de les sales annexes
Resumo:
In this manuscript, seasonal and spatial trends of water collected from two sampling places in the Preto River in the Turvo-Grande watershed were evaluated. Water samples were collected during June/07 to July/08 and parameters sulphate, total organic carbon, ammonia, conductivity, dissolved oxygen, temperature, dissolved total solids and nitrate were quantified. Seasonal trend indicated sanitary effluents as a point source of contamination in both sampling points. Vertical trends demonstrated that the Municipal Dam was not stratified and received a diffuse source of pollutants from flooding and agriculture runoffs. It was also verified that there is relatively fast ammonia consumption kinetics having a half-life time of 1.43 h which can explain the low ammonia concentrations found in these aquatic bodies.