976 resultados para matéria orgânica
Resumo:
Plants produce a number of substances and products and primary and secondary metabolites (SM) are amongst them with many benefits but limitation as well. Usually, the fodder are not considered toxic to animals or as a source having higher SM. The Brachiaria decumbens has a considerable nutritional value, but it is considered as a toxic grass for causing photosensitization in animals, if the grass is not harvested for more than 30 days or solely. The absence of detailed information in the literature about SM in Brachiaria, metabolites production and its chemical profile enable us to focus not only on the nutritive value but to get answers in all aspects and especially on toxicity. The study was conducted in the period of december 2013 to december 2014; in greenhouse FZEA-USP. B. decumbens was used with two cutting heights (10 and 20 cm) and nitrogen doses (0, 150, 300 and 450 kg ha-1) in complete randomized block design. The bromatological analysis were carried out on near infrared spectroscopy. Generally, the application of 150 kg ha-1 N was sufficient to promote the nutritional value in B. decumbens but above it the nitrogen use efficiency decline significantly. The highest dry matter yield (99.97 g/pot) was observed in autumn and the lowest was in winter (30.20 g/pot). While, as per nitrogen dose the average highest dry matter yield was at 150 kg ha-1 (79.98 g/pot). The highest crude protein was observed in winter (11.88%) and the lowest in autumn (7.78%). By the cutting heights; the 10 cm proved to have high CP (9.51%). In respect of fibrous contents, the highest acid detergent fiber was noted in summer (36.37%) and lowest in winter (30.88%). While the neutral detergent fiber was being highest in autumn and lowest in spring (79.60%). The highest in vitro dry matter and organic matter digestibilities were noted at 300 kg ha-1 N; being 68.06 and 60.57%; respectively; with the lowest observed in without N treatments (62.63% and 57.97), respectively. For determination of the classes, types and concentration of SM in B. decumbens, phytochemical tests, thin layer and liquid chromatography-mass spectrometry and nuclear magnetic resonance analysis were carried out. Height, nitrogen and seasons significantly (P <0.0001) affected the secondary metabolic profile. A new protodioscin isomer (protoneodioscin (25S-)) was identified for first time in B. decumbens and is supposed to be the probable toxicity reason. Its structure was verified by 1D and 2D NMR techniques (1H, 13C) and 1D (COSY-45, edited HSQC, HMBC, H2BC, HSQC -TOCSY, NOESY and 1 H, 1 H, J). All factors influence the metabolic profile significantly (P <0.0001). The lowest phenols were at 300 kg ha-1 while the lowest flavones were at 0 kg ha-1. Season wise the highest phenols occurred in autumn (19.65 mg/g d.wt.) and highest flavones (28.87 mg/g d.wt.) in spring. Seasons effect the saponin production significantly (P <0.0001) and the results showed significant differences in the protodioscin (17.63±4.3 - 22.57±2.2 mg/g d.wt.) and protoneodioscin (23.3±1.2 - 31.07±2.9 mg/g d.wt.) concentrations. The highest protodioscin isomers concentrations were observed in winter and spring and by N doses the highest were noted in 300 kg ha-1. Simply, all factors significantly played their role in varying concentrations of secondary metabolites.
Resumo:
Presentació sobre cicle del carboni, del curs sobre Modelització de Sistemes Ecològics.
Resumo:
Manual de pràctiques de laboratori de l'assignatura Modelització de Sistemes Ecològics.
Resumo:
The contamination of water sources of public drinking by waste originated by anthropogenic activities has brought various risks to human health. Among the consequences of such activities can highlight the bloom of microalgae and cyanobacteria, which have the potential to produce toxins dangerous to humans, and the presence of humic substances that are generated by the decomposition of natural organic matter (NOM), such as vegetation. When found in water sources for public supply, present negative aspects conferring high color, odor and taste. The double filtration technology has good efficiency in water with the presence of cyanobacteria and different quality variations. Therefore, this study aimed to evaluate the behavior of the technique of double filtration with pre-oxidation for water purifiers the lagoon of Extremoz-RN, which currently has high concentrations of cyanobacteria. The research is summarized in four phases: the first phase turned to static tests in jarteste equipment in the laboratory and subsequent phases were tested in the Pilot Plant of Double Filtration. For the second and third stage filtration rates were tested filtration rates of 120 and 180 m3 / m2 .day for ascending boulders filters and 160 and 240 m3 / m2 .day in the filters in quick sand descendants. The last phase aimed to evaluate the double filtration with pre-oxidation. The results demonstrated that the system could produce double filtration in all trials of good quality water according to the Decree nº. 2914/11 of the Ministry of Health. The use of preoxidation favored the removal of microcystin and color at the end of the tests, reaching a percentage of color removal around 60%. The analysis of variance in the data, enabled prove that the filtration rates of 180 m3 / m2.d the gravel filter and 240 m3 /m2 .d in rapid filters, were the most significant for the removal of turbidity. The ascending filter of boulder 4 with particle size finer filter layer showed the best performance and the best means of turbidity and apparent color. The rapid filter downward 1 was more efficient in removing turbidity reaching removal about 100%
Resumo:
In this work the degradation of real and synthetic wastewater was studied using electrochemical processes such as oxidation via hydroxyl radicals, mediated oxidation via active chlorine and electrocoagulation. The real effluent used was collected in the decanter tank of the Federal University of Rio Grande do Norte (ETE-UFRN) of Effluent Treatment Plant and the other a textile effluent dye Ácido Blue 113 (AB 113) was synthesized in the laboratory. In the electrochemical process, the effects of anode material, current density, the presence and concentration of chloride as well as the active chlorine species on site generated were evaluated. Electrodes of different compositions, Ti/Pt, Ti/Ru0,3Ti0,7O2, BDD, Pb/PbO2 and Ti/TiO2-nanotubes/PbO2 were used as anodes. These electrodes were subjected to electroanalytical analysis with the goal of checking how happen the anodic and cathodic processes across the concentrations of NaCl and supporting electrolyte used. The potential of oxygen evolution reaction were also checked. The effect of active chlorine species formed under the process efficiency was evaluated by removing the organic matter in the effluent-ETE UFRN. The wastewater treatment ETE-UFRN using Ti/Pt, DDB and Ti/Ru0,3Ti0,7O2 electrodes was evaluated, obtaining good performances. The electrochemical degradation of effluent-UFRN was able to promote the reduction of the concentration of TOC and COD in all tested anodes. However, Ti/Ru0,3Ti0,7O2 showed a considerable degradation due to active chlorine species generated on site. The results obtained from the electrochemical process in the presence of chloride were more satisfactory than those obtained in the absence. The addition of 0.021 M NaCl resulted in a faster removal of organic matter. Secondly, was prepared and characterized the electrode Ti/TiO2-nanotubes/PbO2 according to what the literature reports, however their preparation was to disk (10 cm diameter) with surface area and higher than that described by the same authors, aiming at application to textile effluent AB 113 dye. SEM images were taken to observe the growth of TiO2 nanotubes and confirm the electrodeposition of PbO2. Atomic Force Microscope was also used to confirm the formation of these nanotubes. Furthermore, was tested and found a high electrochemical stability of the electrode Ti/TiO2-nanotubes/PbO2 for applications such as long-term indicating a good electrocatalytic material. The electrochemical oxidation of AB 113 using Ti/Pt, Pb/PbO2 and Ti/TiO2-nanotubes/PbO2 and Al/Al (electrocoagulation) was also studied. However, the best color removal and COD decay were obtained when Ti/TiO2-nanotubes/PbO2 was used as the anode, removing up to 98% of color and 92,5% of COD decay. Analysis of GC/MS were performed in order to identify possible intermediates formed in the degradation of AB 113.
Resumo:
Petroleum exploration activity occurs on the offshore Potiguar Basin, from very shallow (2-3 m) until about 50 m water depth, extending from Alto de Touros (RN) to Alto de Fortaleza (CE). Take in account the biological importance and the heterogeneity of sediments on this area, it is necessary the understanding of the sedimentological dynamics, and mainly the changes generated by petroleum exploration to prevent possible damages to environment. Despite the intense activity of oil exploration in this area, research projects like these are still rare. In view to minimize this gap, this study was developed to evaluate sedimentological, mineralogical and geochemical changes in the vicinity of a exploration well, here designated as well A, located on the Middle continental shelf, near the transition to Outer shelf. The well selected for this study was the first one drilled with Riserless Mud Recovery technology (RMR) in Brazil. The main difference from this to the conventional method is the possibility of drilling phase I of the well with return of drilling material to the rig tank, minimizing fluid and gravel discharging around the vicinity, during this phase. Monitoring consisted of three surveys, first of them done before start drilling, the second one done 19 days after the end of drilling and the third one done one year after then. Comparison of the studied variables (calcium carbonate and organic matter content, sediment size, mineralogy and geochemistry) was done with their average, median and coefficient of variation values to understand the changes after drilling activity. Because operating company technical reasons, the well location was changed after the first survey (C1), resulting in a shift of the sampled area on the two last surveys (C2 e C3). Nevertheless, the acquired data presented a good correlation, with no loss to the mean goal of the study. The sedimentological, mineralogical and geochemical analyzes were done at Federal University of Rio Grande do Norte (UFRN). The results indicated a predominantly sandy environment along the three surveys. It was noticed that the first survey (C1), presented different values for all the studied variables than to the second (C2) and third (C3) surveys, which had similar values. Siliciclastic sediments are prevalent at all surveys, and quartz is the main component (more than 80%). Heavy minerals (garnet, turmaline, zircon and lmenite), rock fragments and mud aggregates also was described. Bioclastic sediments are dominated by coralline algae (more than 45%) and mollusks (more than 30%), followed by benthic foraminifera, bryozoans and worm tubes. More rarely was observed ostracoda and spike of calcareous sponge. Because the low changes of the sediments at the studied area and by the using of RMR method in the drilling, it was possible to conclude that drilling activity did not promote significant alteration on the local sediment cover. Changes in the studied variables before and after drilling activity could be influenced by the changing in the sampling area after survey 1 (C1).
Resumo:
The textile sector is one of the main contributors to the generation of industrial wastewaters due to the use of large volumes of water, which has a high organic load content. In these, it is observed to the presence of dyes, surfactants, starch, alcohols, acetic acid and other constituents, from the various processing steps of the textiles. Hence, the treatment of textile wastewater becomes fundamental before releasing it into water bodies, where they can cause disastrous physical-chemical changes for the environment. Surfactants are substances widely used in separation processes and their use for treating textile wastewaters was evaluated in this research by applying the cloud point extraction and the ionic flocculation. In the cloud point extraction was used as surfactant nonylphenol with 9.5 ethoxylation degree to remove reactive dye. The process evaluation was performed in terms of temperature, surfactant and dye concentrations. The dye removal reached 91%. The ionic flocculation occurs due to the presence of calcium, which reacts with anionic surfactant to form insoluble surfactants capable of attracting the organic matter by adsorption. In this work the ionic flocculation using base soap was applied to the treatment of synthetic wastewater containing dyes belonging to three classes: direct, reactive, and disperse. It was evaluated by the influence of the following parameters: surfactant and electrolyte concentrations, stirring speed, equilibrium time, temperature, and pH. The flocculation of the surfactant was carried out in two ways: forming the floc in the effluent itself and forming the floc before mixing it to the effluent. Removal of reactive and direct dye, when the floc is formed into textile effluent was 97% and 87%, respectively. In the case where the floc is formed prior to adding it to the effluent, the removal to direct and disperse dye reached 92% and 87%, respectively. These results show the efficience of the evaluated processes for dye removal from textile wastewaters.
Resumo:
Systems of incised valleys have been studied in different continental shelves, including the Brazilian continental margin. The interest to characterize this feature is given by the information that it can provide variations on sea level, as well as the ability to host economically significant quantities of hydrocarbons in reservoirs located in deposits filling of the incised valleys. This thesis has the overall objective to characterize the morphology and sedimentary cover of the incised valley Apodi-Mossoró, located in the Northern Continental shelf of Rio Grande do Norte state, adjacent to Areia Branca city. The methodology included the integration of satellite imagery, bathymetric data, sedimentological data, shallow seismic, and the identification of foraminifera. The results indicate that the ApodiMossró incised valley is currently formed by two channels, shallow channel and deep channel, which have distinct morphological and sedimentological characteristics. The deep channel has connection with one of the heads of the Apodi Canyon, located in the slope area. The acquisition, processing and interpretation of shallow seismic data allowed the recognition of the depositional surface, erosional surface, discordance, and sismofaceis. The erosional surface mapped from shallow seismic sections is possibly a indicative of an ancient surface of valley incision, where it would probably be associated with the limit Pleistocene/Holocene. Different sismofaceis were identified and reflect the rise in sea level with standards sometimes agradacional, sometimes progradational. The thickness of sediments on this surface was estimated at a maximum of 22m thick in the central portion of the incised valley. Statistically, there are differences between the adjacent continental shelf and channels, and between these channels, for the content of calcium carbonate, organic matter, sand and mud perceptual, except for the gravel grain size. The analysis of living and dead foraminifera showed the presence of fifty species distributed in regards to morphology, depth and type of sediment. Four type of seismic echocharacteres were identified and mapped, as well as their bedforms, indicating different sedimentary processes along the incised valley. The integration of results suggests an activation of the Apodi-Mossoró incised valley in the Late Pleistocene.
Resumo:
The sabiá (Mimosa caesalpiniaefolia Benth.) is an endemic species of the Caatinga biome, considered tolerant to salt and water stress. The process of salinization of soil and groundwater and surface water is one of the most important problems of environmental degradation, with its harmful effects being more pronounced in the areas of arid and semiarid regions, and rapidly growing in many parts of the globe, causing problems of the major crop yield. Organic conditioners as barnyard manure, and rice hulls can contribute to reducing the PST, possibly due to the release of CO2 and the production of organic acids during the decomposition of organic matter, and act as sources of calcium and magnesium and inhibit the availability sodium. The intimate association of mycorrhizae and beneficial to plants results in increased uptake of water and nutrients by plants, especially phosphorus, due to their low mobility in soil. The objective of this study was to evaluate the initial growth of thrush seedlings under inoculation with mycorrhizal fungi and fertilized with manure corral and irrigated with water of different salinity levels. The experiment was conducted in greenhouse conditions of vegetation on the premises of the Agricultural School of Jundiaí - UFRN, Campus Macaíba. The adopted statistical design was randomized composed of twelve treatments - three substrates (sterile soil, manure and FMA), four salinity levels (0.2, 1.5, 3.0 and 4.5 dS m-1 ) and five repetitions, totaling sixty experimental units. The results indicate that inoculation with mycorrhizal fungi own contributions to the growth of plants, especially in roots and shoots, which suggests that its application is beneficial in establishing thrush plants in natural conditions, with poor soil in P. Levels salinity caused no effects with statistical significance in plant development, indicating Sabia resistance to it.
Resumo:
Stabilization ponds are biological treatment systems in that stabilization of organic matter is performed by the bacterial oxidation and / or reduction of photosynthetic algae. This study aimed to monitor and evaluate the efficiency of stabilization ponds in the Rio Grande do Norte State. Collections were made of the treated effluent, made directly in the output boxes of facultative lagoons and maturation (M1 and M2) and raw sewage (EB) that arrived at the stations. The variables analyzed were: pH, temperature, dissolved oxygen, total suspended solids, chlorophyll "a", apparent color, total phosphorus, organic nitrogen, ammonia nitrogen, Kjeldahl nitrogen, turbidity, cyanobacteria density and concentrations of microcystin. Variance analysis (ANOVA one way) observing the premises using the Tukey test, so as to check differences between treatments. The evaluate the stations found to COD removals in the bands of 48,8% (Pipa) to 75,8% (Caiçara Rio do Vento) and 57,5% (Pipa) to 83,0% (Santo Antônio), respectively. The mean concentrations of cyanobacteria varied from LFs density of 62,545 cels.mL-1 (Pedro Velho Roça) cels.mL-1 to 2,669,048 (Ponta Negra), while the final effluent showed range between 9,072 Cels.mL- 1 (Pedro Velho Roça) to 1,899,981 cels.mL-1 (Macau – Ilha de Santana) and the average concentrations of microcystin the final effluent ranged from 0.02 μg.L-1 (Ponta Negra) to 0.15 μg.L-1 (Macau – Ilha de Santana) at the studied the stations.
Resumo:
This paper proposed the study of the treatment of a synthetic wastewater contaminated with BTX by electro-oxidation batch with the anode of Ti/PbO2, and the adsorption of BTX using expanded perlite as adsorbent material, and to evaluate the best operating conditions both methods in order to perform a sequential treatment (adsorption and electro-oxidation) and achieve greater efficiency in the removal of the compounds. The operating conditions were measured: temperature, current density and applied amount of the adsorbent material, by UV-VIS analysis and Demand Chemical oxygen demand (COD). According to the experimental results, the electro-oxidative treatment was efficient in the degradation of the compounds BTX (benzene, toluene and xylenes) in synthetic sewage due to the electrochemical properties of the anode of Ti/PbO2. The applied current density and temperature promoted increased efficiency of COD removal, reaching obtain percentages greater than 70%. In the adsorption process, the temperature increase was not a factor in the removal of organic matter, while the increase in the amount of adsorbent material led to an increase in the percentage removal, obtaining 66.30% using 2 g of adsorbent. The selected operating conditions of both treatments performed separately take into account the removal efficiency of organic matter, and the low energy consumption and operating costs, so the sequential treatment were satisfactory reaching 87.26% of COD removal using adsorption as a pretreatment. Quantification of BTX through the analysis of gas chromatography at the end of the treatments also confirmed the removal efficiency of organic compounds, giving outstanding advantages to sequential treatment.
Resumo:
This work was performing effluent degradation studies by electrochemical treatment. The electrochemical oxidation (EO) hydroquinone (H2Q) was carried out in acid medium, using PbO2 electrode by galvanostatic electrolysis, applying current densities of 10 and 30 mA/cm2 . The concentration of H2Q was monitored by differential pulse voltammetry (DPV). The experimental results showed that the galvanostatic electrolysis process performance significantly depends on the applied current density, achieving removal efficiencies of 100% and 80 % and 10 applying 30 mA/cm2 , respectively. Furthermore, the electroanalytical technique was effective in H2Q be used as a detection method. In order to test the efficiency of PbO2 electrode, the electrochemical treatment was conducted in an actual effluent, leachate from a landfill. The liquid waste leachate (600ml effluent) was treated in a batch electrochemical cell, with or without addition of NaCl by applying 7 mA/cm2 . The efficiency of EO was assessed against the removal of thermo-tolerant coliforms, total organic carbon (TOC), total phosphorus and metals (copper, cobalt, chromium, iron and nickel). These results showed that efficient removal of coliforms was obtained (100%), and was further decrease the concentration of heavy metals by the cathode processes. However, results were not satisfactory TOC, achieving low total removal of dissolved organic load. Because it is considered an effluent complex were developed other tests with this effluent to monitor a larger number of decontamination parameters (Turbidity, Total Solids, Color, Conductivity, Total Organic Carbon (TOC) and metals (barium, chromium, lithium, manganese and Zinc), comparing the efficiency of this type of electrochemical treatment (EO or electrocoagulation) using a flow cell. In this assay was compared to electro streaming. In the case of the OE, Ti/IrO2-TaO5 was used as the anode, however, the electrocoagulation process, aluminum electrodes were used; applying current densities of 10, 20 and 30 mA/cm2 in the presence and absence of NaCl as an electrolyte. The results showed that EO using Ti/IrO2–TaO5 was anode as efficient when Cl- was present in the effluent. In contrast, the electrocoagulation flow reduces the dissolved organic matter in the effluent, under certain experimental conditions.
Resumo:
The textile effluents are a complex mixture of many pollutants that contain high organic loads, severe color and toxic compounds. The high concentration of the textile effluent may cause increased chemical demand (COD) and biochemical (BOD) of oxygen, elevated temperature, acidity or alkalinity, causing damage and environmental problems. In addition to representing a serious threat to human health such effluent is also quite toxic to most aquatic organisms. And for this reason, one must meet the concentration limits for emission sources and sewage system. This study aimed to investigate the performance of electrochemical treatment of a textile effluent for the removal of color, turbidity, dissolved oxygen (DO) and dissolved organic matter by investigating the influence of experimental parameters such as the electrocatalyst materials (Ti/Pt and Ti/Pt-SnSb) and current density in order to compare their efficiency, energy consumption and cost. The dye Novacron Blue CD (NB) was employed in synthetic solution, while the dyes Remazol Yellow 3RS (RY 3RS) Remazol Red RR Gran (RR-RR Gran) and Navy Blue CL-R (NB CL-R) were used to generate simulated textile effluent laboratory. The results showed that the application of electrochemical oxidation process favors the elimination of color effectively independent the electrocatalytic material and current used, as well as treated effluent. However, the influence of electrocatalytic material was crucial to reduction of the organic matter in all cases.
Resumo:
This study aimed to evaluate the potential of oxidative electrochemical treatment coupled with adsorption process using expanded perlite as adsorbent in the removal of textile dyes, Red Remazol and Novacron Blue on synthetic effluent. Dyes and perlite were characterized by thermogravimetry techniques (TG), Differential Scanning Calorimetry (DSC), Spectroscopy infrared (IR), Scanning Electron Microscopy (SEM), X-ray diffraction (XRD) and X-ray fluorescence (XRF) techniques. Electrochemical treatments used as anodes, Ti/Pt and Pb/PbO2 under different conditions: 60 minutes, current density 20, 40 e 60 mAcm-2, pH 1, 4.5 e 8 and temperature variation 20, 40 e 60 ºC. In the case of adsorption tests, contact time of 30 minutes for the Remazol Red dye and 20 minutes for Novacron Blue were established, while pH 1, 4.5 e 8, 500 mg adsorbent and temperature variation 20, 40 e 60 ºC were used for both treatments. The results indicated that both treatments, electroxidation/adsorption and the adsorption/electroxidation, were effective for removing color from synthetic solutions. The consumption of electricity allowed to evaluate the applicability of the electrochemical process, providing very acceptable values, which allowed us to estimate the cost. Total organic carbon (TOC) and Gas Chromatography linked mass spectrometer (GC-MS) analyzes were performed, showing that the better combination for removing organic matter is by Pb/PbO2 and perlite. Meanwhile, GC-MS indicated that the by-products formed are benzoic acid, phthalic acid, thiocarbamic acid, benzene, chlorobenzene, phenol-2-ethyl and naphthalene when Remazol Red was degraded. Conversely, aniline, phthalic acid, 1, 6 - dimethylnaphthalene, naphthalene and ion hidroxobenzenosulfonat was detected when Novacron Blue was studied. Analyses obtained through atomic absorption spectrometry showed that there was release of lead in the electrochemical oxidation of analyzes that were performed with the anode Pb/PbO2, but these values are reduced by subjecting the effluent to adsorption analysis. According to these results, sequential techniques electroxidation/adsorption and adsorption/electroxidation are to treat solutions containing dyes.
Resumo:
This study aimed to evaluate the potential of oxidative electrochemical treatment coupled with adsorption process using expanded perlite as adsorbent in the removal of textile dyes, Red Remazol and Novacron Blue on synthetic effluent. Dyes and perlite were characterized by thermogravimetry techniques (TG), Differential Scanning Calorimetry (DSC), Spectroscopy infrared (IR), Scanning Electron Microscopy (SEM), X-ray diffraction (XRD) and X-ray fluorescence (XRF) techniques. Electrochemical treatments used as anodes, Ti/Pt and Pb/PbO2 under different conditions: 60 minutes, current density 20, 40 e 60 mAcm-2, pH 1, 4.5 e 8 and temperature variation 20, 40 e 60 ºC. In the case of adsorption tests, contact time of 30 minutes for the Remazol Red dye and 20 minutes for Novacron Blue were established, while pH 1, 4.5 e 8, 500 mg adsorbent and temperature variation 20, 40 e 60 ºC were used for both treatments. The results indicated that both treatments, electroxidation/adsorption and the adsorption/electroxidation, were effective for removing color from synthetic solutions. The consumption of electricity allowed to evaluate the applicability of the electrochemical process, providing very acceptable values, which allowed us to estimate the cost. Total organic carbon (TOC) and Gas Chromatography linked mass spectrometer (GC-MS) analyzes were performed, showing that the better combination for removing organic matter is by Pb/PbO2 and perlite. Meanwhile, GC-MS indicated that the by-products formed are benzoic acid, phthalic acid, thiocarbamic acid, benzene, chlorobenzene, phenol-2-ethyl and naphthalene when Remazol Red was degraded. Conversely, aniline, phthalic acid, 1, 6 - dimethylnaphthalene, naphthalene and ion hidroxobenzenosulfonat was detected when Novacron Blue was studied. Analyses obtained through atomic absorption spectrometry showed that there was release of lead in the electrochemical oxidation of analyzes that were performed with the anode Pb/PbO2, but these values are reduced by subjecting the effluent to adsorption analysis. According to these results, sequential techniques electroxidation/adsorption and adsorption/electroxidation are to treat solutions containing dyes.