991 resultados para load


Relevância:

20.00% 20.00%

Publicador:

Resumo:

English has been taught as a core and compulsory subject in China for decades. Recently, the demand for English in China has increased dramatically. China now has the world's largest English-learning population. The traditional English-teaching method cannot continue to be the only approach because it merely focuses on reading, grammar and translation, which cannot meet English learners and users' needs (i.e., communicative competence and skills in speaking and writing). ^ This study was conducted to investigate if the Picture-Word Inductive Model (PWIM), a new pedagogical method using pictures and inductive thinking, would benefit English learners in China in terms of potential higher output in speaking and writing. With the gauge of Cognitive Load Theory (CLT), specifically, its redundancy effect, I investigated whether processing words and a picture concurrently would present a cognitive overload for English learners in China. ^ I conducted a mixed methods research study. A quasi-experiment (pretest, intervention for seven weeks, and posttest) was conducted using 234 students in four groups in Lianyungang, China (58 fourth graders and 57 seventh graders as an experimental group with PWIM and 59 fourth graders and 60 seventh graders as a control group with the traditional method). No significant difference in the effects of PWIM was found on vocabulary acquisition based on grade levels. Observations, questionnaires with open-ended questions, and interviews were deployed to answer the three remaining research questions. A few students felt cognitively overloaded when they encountered too many writing samples, too many new words at one time, repeated words, mismatches between words and pictures, and so on. Many students listed and exemplified numerous strengths of PWIM, but a few mentioned weaknesses of PWIM. The students expressed the idea that PWIM had a positive effect on their English teaching. ^ As integrated inferences, qualitative findings were used to explain the quantitative results that there were no significant differences of the effects of the PWIM between the experimental and control groups in both grade levels, from four contextual aspects: time constraints on PWIM implementation, teachers' resistance, how to use PWIM and PWIM implemented in a classroom over 55 students.^

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Damages during extreme wind events highlight the weaknesses of mechanical fasteners at the roof-to-wall connections in residential timber frame buildings. The allowable capacity of the metal fasteners is based on results of unidirectional component testing that do not simulate realistic tri-axial aerodynamic loading effects. The first objective of this research was to simulate hurricane effects and study hurricane-structure interaction at full-scale, facilitating better understanding of the combined impacts of wind, rain, and debris on inter-component connections at spatial and temporal scales. The second objective was to evaluate the performance of a non-intrusive roof-to-wall connection system using fiber reinforced polymer (FRP) materials and compare its load capacity to the capacity of an existing metal fastener under simulated aerodynamic loads. The Wall of Wind (WoW) testing performed using FRP connections on a one-story gable-roof timber structure instrumented with a variety of sensors, was used to create a database on aerodynamic and aero-hydrodynamic loading on roof-to-wall connections tested under several parameters: angles of attack, wind-turbulence content, internal pressure conditions, with and without effects of rain. Based on the aerodynamic loading results obtained from WoW tests, sets of three force components (tri-axial mean loads) were combined into a series of resultant mean forces, which were used to test the FRP and metal connections in the structures laboratory up to failure. A new component testing system and test protocol were developed for testing fasteners under simulated tri-axial loading as opposed to uni-axial loading. The tri-axial and uni-axial test results were compared for hurricane clips. Also, comparison was made between tri-axial load capacity of FRP and metal connections. The research findings demonstrate that the FRP connection is a viable option for use in timber roof-to-wall connection system. Findings also confirm that current testing methods of mechanical fasteners tend to overestimate the actual load capacities of a connector. Additionally, the research also contributes to the development a new testing protocol for fasteners using tri-axial simultaneous loads based on the aerodynamic database obtained from the WoW testing.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The current study applied classic cognitive capacity models to examine the effect of cognitive load on deception. The study also examined whether the manipulation of cognitive load would result in the magnification of differences between liars and truth-tellers. In the first study, 87 participants engaged in videotaped interviews while being either deceptive or truthful about a target event. Some participants engaged in a concurrent secondary task while being interviewed. Performance on the secondary task was measured. As expected, truth tellers performed better on secondary task items than liars as evidenced by higher accuracy rates. These results confirm the long held assumption that being deceptive is more cognitively demanding than being truthful. In the second part of the study, the videotaped interviews of both liars and truth-tellers were shown to 69 observers. After watching the interviews, observers were asked to make a veracity judgment for each participant. Observers made more accurate veracity judgments when viewing participants who engaged in a concurrent secondary task than when viewing those who did not. Observers also indicated that participants who engaged in a concurrent secondary task appeared to think harder than participants who did not. This study provides evidence that engaging in deception is more cognitively demanding than telling the truth. As hypothesized, having participants engage in a concurrent secondary task led to the magnification of differences between liars and truth tellers. This magnification of differences led to more accurate veracity rates in a second group of observers. The implications for deception detection are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Implicit in current design practice of minimum uplift capacity, is the assumption that the connection's capacity is proportional to the number of fasteners per connection joint. This assumption may overestimate the capacity of joints by a factor of two or more and maybe the cause of connection failures in extreme wind events. The current research serves to modify the current practice by proposing a realistic relationship between the number of fasteners and the capacity of the joint. The research is also aimed at further development of non-intrusive continuous load path (CLP) connection system using Glass Fiber Reinforced Polymer (GFRP) and epoxy. Suitable designs were developed for stud to top plate and gable end connections and tests were performed to evaluate the ultimate load, creep and fatigue behavior. The objective was to determine the performance of the connections under simulated sustained hurricane conditions. The performance of the new connections was satisfactory.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acknowledgments The financial support of the part of this research by The Royal Society, The Royal Academy of Engineering and The Carnegie Trust for the Universities of Scotland is gratefully acknowledged.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The work is supported in part by NSFC (Grant no. 61172070), IRT of Shaanxi Province (2013KCT-04), EPSRC (Grant no.Ep/1032606/1).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Acknowledgments The financial support of the part of this research by The Royal Society, The Royal Academy of Engineering and The Carnegie Trust for the Universities of Scotland is gratefully acknowledged.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The work is supported in part by NSFC (Grant no. 61172070), IRT of Shaanxi Province (2013KCT-04), EPSRC (Grant no.Ep/1032606/1).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Feed characteristics may influence the bacterial community composition and metabolic activities in the pig gastrointestinal tract, known to be associated with positive effects on the gut. Use of mash feed is associated with reduced Salmonella excretion, but little is known of its effect on the Escherichia coli population or of the mechanism of action. Our objectives were to assess the effect of feed texture combined with feed particle size on VFA profiles and levels, total E. coli count, and the presence of genes encoding virulence factors of pathogenic E. coli strains in the digestive tract along with their impact on pig performance of fattening pigs. Pigs (n = 840) on a commercial farm received mash or pellet diets of different particle sizes during the fattening period. Caecal and colon contents from 164 pigs were sampled at the slaughterhouse for enumeration of E. coli by quantitative PCR (qPCR) and for VFA quantification by capillary gas chromatography. The yccT gene was used to enumerate total E. coli. Improved pig performances associated with pellet texture and a 500-μm size were observed. Caecal (P = 0.02) and colon (P < 0.01) propionic acid concentrations were lower for pigs receiving pellet rather than mash feed. Similarly, caecal (P = 0.01) and colon (P < 0.001) butyric acid concentrations were also lower for pigs receiving pellet rather than mash feed, as determined by capillary gas chromatography. Moreover, caecal (P = 0.03) and colon (P < 0.001) butyric acid concentrations were higher for pigs receiving a feed with a 1,250-μm particle size rather than a 500-μm particle size. On the other hand, total caecal and colon E. coli levels were higher for pigs receiving pellet feed than for those receiving mash feed. For total E. coli enumeration, caecal (P < 0.01) and colon (P < 0.01) yccT gene copies were higher for pigs receiving pellet rather than mash feed. No effect of particle size on fatty acid concentrations or on E. coli numbers was observed. Virulence gene quantification revealed no trend. Taken together, results showed that mash feed is associated with lower growth performance but with favorable intestinal changes linked to VFA levels and E. coli reduction in the intestine.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mémoire numérisé par la Direction des bibliothèques de l'Université de Montréal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports on an investigation with first year undergraduate Product Design and Management students within a School of Engineering. The students at the time of this investigation had studied fundamental engineering science and mathematics for one semester. The students were given an open ended, ill formed problem which involved designing a simple bridge to cross a river. They were given a talk on problem solving and given a rubric to follow, if they chose to do so. They were not given any formulae or procedures needed in order to resolve the problem. In theory, they possessed the knowledge to ask the right questions in order to make assumptions but, in practice, it turned out they were unable to link their a priori knowledge to resolve this problem. They were able to solve simple beam problems when given closed questions. The results show they were unable to visualise a simple bridge as an augmented beam problem and ask pertinent questions and hence formulate appropriate assumptions in order to offer resolutions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conventional reliability models for parallel systems are not applicable for the analysis of parallel systems with load transfer and sharing. In this short communication, firstly, the dependent failures of parallel systems are analyzed, and the reliability model of load-sharing parallel system is presented based on Miner cumulative damage theory and the full probability formula. Secondly, the parallel system reliability is calculated by Monte Carlo simulation when the component life follows the Weibull distribution. The research result shows that the proposed reliability mathematical model could analyze and evaluate the reliability of parallel systems in the presence of load transfer.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Feed characteristics may influence the bacterial community composition and metabolic activities in the pig gastrointestinal tract, known to be associated with positive effects on the gut. Use of mash feed is associated with reduced Salmonella excretion, but little is known of its effect on the Escherichia coli population or of the mechanism of action. Our objectives were to assess the effect of feed texture combined with feed particle size on VFA profiles and levels, total E. coli count, and the presence of genes encoding virulence factors of pathogenic E. coli strains in the digestive tract along with their impact on pig performance of fattening pigs. Pigs (n = 840) on a commercial farm received mash or pellet diets of different particle sizes during the fattening period. Caecal and colon contents from 164 pigs were sampled at the slaughterhouse for enumeration of E. coli by quantitative PCR (qPCR) and for VFA quantification by capillary gas chromatography. The yccT gene was used to enumerate total E. coli. Improved pig performances associated with pellet texture and a 500-μm size were observed. Caecal (P = 0.02) and colon (P < 0.01) propionic acid concentrations were lower for pigs receiving pellet rather than mash feed. Similarly, caecal (P = 0.01) and colon (P < 0.001) butyric acid concentrations were also lower for pigs receiving pellet rather than mash feed, as determined by capillary gas chromatography. Moreover, caecal (P = 0.03) and colon (P < 0.001) butyric acid concentrations were higher for pigs receiving a feed with a 1,250-μm particle size rather than a 500-μm particle size. On the other hand, total caecal and colon E. coli levels were higher for pigs receiving pellet feed than for those receiving mash feed. For total E. coli enumeration, caecal (P < 0.01) and colon (P < 0.01) yccT gene copies were higher for pigs receiving pellet rather than mash feed. No effect of particle size on fatty acid concentrations or on E. coli numbers was observed. Virulence gene quantification revealed no trend. Taken together, results showed that mash feed is associated with lower growth performance but with favorable intestinal changes linked to VFA levels and E. coli reduction in the intestine.