966 resultados para instantaneous frequency measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article presents the first measurement of the ratio of branching fractions B(Λb0→Λc+μ-ν̅ μ)/B(Λb0→Λc+π-). Measurements in two control samples using the same technique B(B̅ 0→D+μ-ν̅ μ)/B(B̅ 0→D+π-) and B(B̅ 0→D*(2010)+μ-ν̅ μ)/B(B̅ 0→D*(2010)+π-) are also reported. The analysis uses data from an integrated luminosity of approximately 172  pb-1 of pp̅ collisions at √s=1.96  TeV, collected with the CDF II detector at the Fermilab Tevatron. The relative branching fractions are measured to be B(Λb0→Λc+μ-ν̅ μ)/B(Λb0→Λc+π-)=16.6±3.0(stat)±1.0(syst)+2.6/-3.4(PDG)±0.3(EBR), B(B̅ 0→D+μ-ν̅ μ)/B(B̅ 0→D+π-)= 9.9±1.0(stat)±0.6(syst)±0.4(PDG)±0.5(EBR), and B(B̅ 0→D*(2010)+μ-ν̅ μ)/B(B̅ 0→D*(2010)+π-)=16.5±2.3(stat)± 0.6(syst)±0.5(PDG)±0.8(EBR). The uncertainties are from statistics (stat), internal systematics (syst), world averages of measurements published by the Particle Data Group or subsidiary measurements in this analysis (PDG), and unmeasured branching fractions estimated from theory (EBR), respectively. This article also presents measurements of the branching fractions of four new Λb0 semileptonic decays: Λb0→Λc(2595)+μ-ν̅ μ, Λb0→Λc(2625)+μ-ν̅ μ, Λb0→Σc(2455)0π+μ-ν̅ μ, and Λb0→Σc(2455)++π-μ-ν̅ μ, relative to the branching fraction of the Λb0→Λc+μ-ν̅ μ decay. Finally, the transverse-momentum distribution of Λb0 baryons produced in pp̅ collisions is measured and found to be significantly different from that of B̅ 0 mesons, which results in a modification in the production cross-section ratio σΛb0/σB̅ 0 with respect to the CDF I measurement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report a measurement of the single top quark production cross section in 2.2 ~fb-1 of p-pbar collision data collected by the Collider Detector at Fermilab at sqrt{s}=1.96 TeV. Candidate events are classified as signal-like by three parallel analyses which use likelihood, matrix element, and neural network discriminants. These results are combined in order to improve the sensitivity. We observe a signal consistent with the standard model prediction, but inconsistent with the background-only model by 3.7 standard deviations with a median expected sensitivity of 4.9 standard deviations. We measure a cross section of 2.2 +0.7 -0.6(stat+sys) pb, extract the CKM matrix element value |V_{tb}|=0.88 +0.13 -0.12 (stat+sys) +- 0.07(theory), and set the limit |V_{tb}|>0.66 at the 95% C.L.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A combined mass and particle identification fit is used to make the first observation of the decay B̅ s0→Ds±K∓ and measure the branching fraction of B̅ s0→Ds±K∓ relative to B̅ s0→Ds+π-. This analysis uses 1.2  fb-1 integrated luminosity of pp̅ collisions at √s=1.96  TeV collected with the CDF II detector at the Fermilab Tevatron collider. We observe a B̅ s0→Ds±K∓ signal with a statistical significance of 8.1σ and measure B(B̅ s0→Ds±K∓)/B(B̅ s0→Ds+π-)=0.097±0.018(stat)±0.009(syst).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

16-electrode phantoms are developed and studied with a simple instrumentation developed for Electrical Impedance Tomography. An analog instrumentation is developed with a sinusoidal current generator and signal conditioner circuit. Current generator is developed withmodified Howland constant current source fed by a voltage controlled oscillator and the signal conditioner circuit consisting of an instrumentation amplifier and a narrow band pass filter. Electronic hardware is connected to the electrodes through a DIP switch based multiplexer module. Phantoms with different electrode size and position are developed and the EIT forward problem is studied using the forward solver. A low frequency low magnitude sinusoidal current is injected to the surface electrodes surrounding the phantom boundary and the differential potential is measured by a digital multimeter. Comparing measured potential with the simulated data it is intended to reduce the measurement error and an optimum phantom geometry is suggested. Result shows that the common mode electrode reduces the common mode error of the EIT electronics and reduces the error potential in the measured data. Differential potential is reduced up to 67 mV at the voltage electrode pair opposite to the current electrodes. Offset potential is measured and subtracted from the measured data for further correction. It is noticed that the potential data pattern depends on the electrode width and the optimum electrode width is suggested. It is also observed that measured potential becomes acceptable with a 20 mm solution column above and below the electrode array level.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A precision measurement of the top quark mass m_t is obtained using a sample of ttbar events from ppbar collisions at the Fermilab Tevatron with the CDF II detector. Selected events require an electron or muon, large missing transverse energy, and exactly four high-energy jets, at least one of which is tagged as coming from a b quark. A likelihood is calculated using a matrix element method with quasi-Monte Carlo integration taking into account finite detector resolution and jet mass effects. The event likelihood is a function of m_t and a parameter DJES to calibrate the jet energy scale /in situ/. Using a total of 1087 events, a value of m_t = 173.0 +/- 1.2 GeV/c^2 is measured.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present the first direct measurement of the $W$ production charge asymmetry as a function of the $W$ boson rapidity $\yW$ in $\ppbar$ collisions at $\sqrt{s} = 1.96$ $\TeV$. We use a sample of $\wenu$ events in data from 1 $\ifb$ of integrated luminosity collected using the CDF II detector. In the region $|\yW|