969 resultados para input method
Resumo:
Increasing anthropogenic pressures urge enhanced knowledge and understanding of the current state of marine biodiversity. This baseline information is pivotal to explore present trends, detect future modifications and propose adequate management actions for marine ecosystems. Coralligenous outcrops are a highly diverse and structurally complex deep-water habitat faced with major threats in the Mediterranean Sea. Despite its ecological, aesthetic and economic value, coralligenous biodiversity patterns are still poorly understood. There is currently no single sampling method that has been demonstrated to be sufficiently representative to ensure adequate community assessment and monitoring in this habitat. Therefore, we propose a rapid non-destructive protocol for biodiversity assessment and monitoring of coralligenous outcrops providing good estimates of its structure and species composition, based on photographic sampling and the determination of presence/absence of macrobenthic species. We used an extensive photographic survey, covering several spatial scales (100s of m to 100s of km) within the NW Mediterranean and including 2 different coralligenous assemblages: Paramuricea clavata (PCA) and Corallium rubrum assemblage (CRA). This approach allowed us to determine the minimal sampling area for each assemblage (5000 cm² for PCA and 2500 cm²for CRA). In addition, we conclude that 3 replicates provide an optimal sampling effort in order to maximize the species number and to assess the main biodiversity patterns of studied assemblages in variability studies requiring replicates. We contend that the proposed sampling approach provides a valuable tool for management and conservation planning, monitoring and research programs focused on coralligenous outcrops, potentially also applicable in other benthic ecosystems
Resumo:
Background: Although there has been an abundant literature in recent years about farmer's lung disease, few addressed occupational measures able to maintain the farmer in his work. Nevertheless we know now that most of the farmers can be kept at the workplace by the way of occupational preventive measures. Methods: This matter is discussed from a case report. A farmer affected by the farmer's lung disease was sent to us by his pneumologist, in order to estimate the possibility of maintaining him in his job and to determine relevant changes at his workplace to minimize risk of exposure to dust antigen. This approach required a visit to the workplace by occupational physician and hygienist. Results: The visit of the workplace pointed out different habits and architectural particularities which were potential sources of exposure. The two main proposed measures to reduce the risk, were to wear respiratory masks while working inside the barn, such as preparing hay, feeding the cattle or sweeping the floor, and to build a direct access from the bathroom (shower and toilet) to the outside, allowing to go out of the barn after taking a shower and changing, without risk of being contaminated again. Although upgrading the shower-toilet is not yet completed to date, the already performed modifications led currently to significant clinical improvements, despite the risk of exposure was high since the animals were in the barn for more than two months. Conclusion: The treatment of the farmer's lung disease must be multidisciplinary involving general practitioner, pneumologist, occupational hygienist and occupational physician.
Resumo:
A comprehensive field detection method is proposed that is aimed at developing advanced capability for reliable monitoring, inspection and life estimation of bridge infrastructure. The goal is to utilize Motion-Sensing Radio Transponders (RFIDS) on fully adaptive bridge monitoring to minimize the problems inherent in human inspections of bridges. We developed a novel integrated condition-based maintenance (CBM) framework integrating transformative research in RFID sensors and sensing architecture, for in-situ scour monitoring, state-of-the-art computationally efficient multiscale modeling for scour assessment.
Resumo:
Even though much improvement has been made in plant transformation methods, the screening of transgenic plants is often a laborious work. Most approaches for detecting the transgene in transformed plants are still timeconsuming, and can be quite expensive. The objective of this study was to search for a simpler method to screen for transgenic plants. The infiltration of kanamycin (100 mg/mL) into tobacco leaves resulted in conspicuous chlorotic spots on the non-transgenic plant leaves, while no spots were seen on the leaves of transformed plants. This reaction occurred regardless of age of the tested plants, and the method has proven to be simple, fast, non-destructive, relatively cheap, and reliable. These results were comparable to those obtained by the polymerase chain reaction (PCR) amplification of the transgene using specific primers.
Resumo:
The ability of a PCR-based restriction fragment length polymorphism (RFLP) analysis of the cytochrome b (mtDNA) to distinguish Apodemus alpicola from two other Apodemus species was investigated. The partial sequencing of the cytochrome b allowed the identification of one enzyme as being potentially diagnostic. This was supported by an analysis of 131 specimens previously identified using morphometric and/or allozymic data, indicating that the PCR-based RFLP method provides a rapid and reliable tool for distinguishing A. alpicola from its two co-occurring congenerics. The method is applicable to samples taken in the field for ecological studies, and could easily be adapted to the identification of museum samples.
Resumo:
A simple method determining airborne monoethanolamine has been developed. Monoethanolamine determination has traditionally been difficult due to analytical separation problems. Even in recent sophisticated methods, this difficulty remains as the major issue often resulting in time-consuming sample preparations. Impregnated glass fiber filters were used for sampling. Desorption of monoethanolamine was followed by capillary GC analysis and nitrogen phosphorous selective detection. Separation was achieved using a specific column for monoethanolamines (35% diphenyl and 65% dimethyl polysiloxane). The internal standard was quinoline. Derivatization steps were not needed. The calibration range was 0.5-80 μg/mL with a good correlation (R(2) = 0.996). Averaged overall precisions and accuracies were 4.8% and -7.8% for intraday (n = 30), and 10.5% and -5.9% for interday (n = 72). Mean recovery from spiked filters was 92.8% for the intraday variation, and 94.1% for the interday variation. Monoethanolamine on stored spiked filters was stable for at least 4 weeks at 5°C. This newly developed method was used among professional cleaners and air concentrations (n = 4) were 0.42 and 0.17 mg/m(3) for personal and 0.23 and 0.43 mg/m(3) for stationary measurements. The monoethanolamine air concentration method described here was simple, sensitive, and convenient both in terms of sampling and analytical analysis.
Resumo:
A new method was developed for breaking high strength prestressed cable. The old method used an aluminum oxide grit packed into a special gripping jaw. The new method uses aluminum shims wrapped around the cable and then is gripped with a V-grip. The new method gives nearly 100% "good breaks" on the cable compared to approximately 10% good breaks with the old method. In addition, the new cable breaking method gives higher ultimate tensile strengths, is more reproducible, is quicker, cleaner and easier on equipment.
Resumo:
BACKGROUND: The activity of the renin-angiotensin system is usually evaluated as plasma renin activity (PRA, ngAI/ml per h) but the reproducibility of this enzymatic assay is notoriously scarce. We compared the inter and intralaboratory reproducibilities of PRA with those of a new automated chemiluminescent assay, which allows the direct quantification of immunoreactive renin [chemiluminescent immunoreactive renin (CLIR), microU/ml]. METHODS: Aliquots from six pool plasmas of patients with very low to very high PRA levels were measured in 12 centres with both the enzymatic and the direct assays. The same methods were applied to three control plasma preparations with known renin content. RESULTS: In pool plasmas, mean PRA values ranged from 0.14 +/- 0.08 to 18.9 +/- 4.1 ngAI/ml per h, whereas those of CLIR ranged from 4.2 +/- 1.7 to 436 +/- 47 microU/ml. In control plasmas, mean values of PRA and of CLIR were always within the expected range. Overall, there was a significant correlation between the two methods (r = 0.73, P < 0.01). Similar correlations were found in plasmas subdivided in those with low, intermediate and high PRA. However, the coefficients of variation among laboratories found for PRA were always higher than those of CLIR, ranging from 59.4 to 17.1% for PRA, and from 41.0 to 10.7% for CLIR (P < 0.01). Also, the mean intralaboratory variability was higher for PRA than for CLIR, being respectively, 8.5 and 4.5% (P < 0.01). CONCLUSION: The measurement of renin with the chemiluminescent method is a reliable alternative to PRA, having the advantage of a superior inter and intralaboratory reproducibility.