999 resultados para hydrophobic parameter


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Distributed Brillouin sensing of strain and temperature works by making spatially resolved measurements of the position of the measurand-dependent extremum of the resonance curve associated with the scattering process in the weakly nonlinear regime. Typically, measurements of backscattered Stokes intensity (the dependent variable) are made at a number of predetermined fixed frequencies covering the design measurand range of the apparatus and combined to yield an estimate of the position of the extremum. The measurand can then be found because its relationship to the position of the extremum is assumed known. We present analytical expressions relating the relative error in the extremum position to experimental errors in the dependent variable. This is done for two cases: (i) a simple non-parametric estimate of the mean based on moments and (ii) the case in which a least squares technique is used to fit a Lorentzian to the data. The question of statistical bias in the estimates is discussed and in the second case we go further and present for the first time a general method by which the probability density function (PDF) of errors in the fitted parameters can be obtained in closed form in terms of the PDFs of the errors in the noisy data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel technology for simultaneous and independent measurement of dual parameters is proposed and experimented. The length of a single fibre Bragg grating (FBG) is divided into two parts. The temperature variation and another measurand can be measured independently and simultaneously, and the thermal effect can be erased with great ease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This dissertation investigates the very important and current problem of modelling human expertise. This is an apparent issue in any computer system emulating human decision making. It is prominent in Clinical Decision Support Systems (CDSS) due to the complexity of the induction process and the vast number of parameters in most cases. Other issues such as human error and missing or incomplete data present further challenges. In this thesis, the Galatean Risk Screening Tool (GRiST) is used as an example of modelling clinical expertise and parameter elicitation. The tool is a mental health clinical record management system with a top layer of decision support capabilities. It is currently being deployed by several NHS mental health trusts across the UK. The aim of the research is to investigate the problem of parameter elicitation by inducing them from real clinical data rather than from the human experts who provided the decision model. The induced parameters provide an insight into both the data relationships and how experts make decisions themselves. The outcomes help further understand human decision making and, in particular, help GRiST provide more accurate emulations of risk judgements. Although the algorithms and methods presented in this dissertation are applied to GRiST, they can be adopted for other human knowledge engineering domains.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To assess the clinical outcomes after implantation of a new hydrophobic acrylic toric intraocular lens (IOL) to correct preexisting corneal astigmatism in patients having routine cataract surgery. SETTING: Four hospital eye clinics throughout Europe. DESIGN: Cohort study. METHODS: This study included eyes with at least 0.75 diopter (D) of preexisting corneal astigmatism having routine cataract surgery. Phacoemulsification was performed followed by insertion and alignment of a Tecnis toric IOL. Patients were examined 4 to 8 weeks postoperatively; uncorrected distance visual acuity (UDVA), corrected distance visual acuity, manifest refraction, and keratometry were measured. Individual patient satisfaction with uncorrected vision and the surgeon’s assessment of ease of handling and performance of the IOL were also documented. The cylinder axis of the toric IOL was determined by dilated slitlamp examination. RESULTS: The study enrolled 67 eyes of 60 patients. Four to 8 weeks postoperatively, the mean UDVA was 0.15 logMAR G 0.17 (SD) and the UDVA was 20/40 or better in 88% of eyes. The mean refractive cylinder decreased significantly postoperatively, from -1.91 +/- 1.07 D to -0.67 +/- 0.54 D. No significant change in keratometric cylinder was observed. The mean absolute IOL misalignment from the intended axis was 3.4 degrees (range 0 to 12 degrees). The good UDVA resulted in high levels of patient satisfaction. CONCLUSION: Implantation of the new toric IOL was an effective, safe, and predictable method to manage corneal astigmatism in patients having routine cataract surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hypercoiling polymers can be suited for application to living systems because they are similar in structure to the protein-based lipid assemblies found at fluid interfaces within the body. This leads to a range of exciting possibilities, not only in membrane transport applications but also in biosensors, drug delivery and mechanistic studies of biological membrane function. This study is focused in the study of the stability and suitability of nanostructures made of a hypercoiling polymer for drug delivery applications. The polymer poly (styrene-maleic acid) (PSMA) was combined with the phospholipid dimyristoylphosphatidylcholine (DMPC) to form amphiphilic nanostructures. The stability and suitability of these polymer-phospholipid nanocarriers for hydrophobic and hydrophilic molecules load and release was analyzed by several techniques. It was found that several of the studied molecules had a substantial effect on the surface charge and stability of the nanocarrier. It was also demonstrated that two types of nanocarriers, chemically modified and unmodified, were able to control the release of the molecules, especially in the case of hydrophobic compounds. In addition, as the hydrophobicity increased the release slowed down. These clear nanocarriers have the potential to behave very favorably at interfaces such as the tear lipid film were transparency is a requirement, giving a new way of controlled drug release in the eye.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The surfaces of bulk carbon nanotubes compacted by plasma spark sintering have been modified with polytetrofluorethylene, thereby producing a super-hydrophobic surface with a contact angle above 160°. The surface roughness and air trapped in pores and between the polytetrofluorethylene particles are responsible for the super-hydrophobility. The material can be machined into desired shapes with fine and complex channels, allowing internal surfaces to also be super-hydrophobic.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Are persistent marketing effects most likely to appear right after the introduction of a product? The authors give an affirmative answer to this question by developing a model that explicitly reports how persistent and transient marketing effects evolve over time. The proposed model provides managers with a valuable tool to evaluate their allocation of marketing expenditures over time. An application of the model to many pharmaceutical products, estimated through (exact initial) Kalman filtering, indicates that both persistent and transient effects occur predominantly immediately after a brand's introduction. Subsequently, the size of the effects declines. The authors theoretically and empirically compare their methodology with methodology based on unit root testing and demonstrate that the need for unit root tests creates difficulties in applying conventional persistence modeling. The authors recommend that marketing models should either accommodate persistent effects that change over time or be applied to mature brands or limited time windows only.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Magnesian limestone is a key construction component of many historic buildings that is under constant attack from environmental pollutants notably by oxides of sulfur via acid rain, particulate matter sulfate and gaseous SO 2 emissions. Hydrophobic surface coatings offer a potential route to protect existing stonework in cultural heritage sites, however, many available coatings act by blocking the stone microstructure, preventing it from 'breathing' and promoting mould growth and salt efflorescence. Here we report on a conformal surface modification method using self-assembled monolayers of naturally sourced free fatty acids combined with sub-monolayer fluorinated alkyl silanes to generate hydrophobic (HP) and super hydrophobic (SHP) coatings on calcite. We demonstrate the efficacy of these HP and SHP surface coatings for increasing limestone resistance to sulfation, and thus retarding gypsum formation under SO/H O and model acid rain environments. SHP treatment of 19th century stone from York Minster suppresses sulfuric acid permeation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Distributed Brillouin sensing of strain and temperature works by making spatially resolved measurements of the position of the measurand-dependent extremum of the resonance curve associated with the scattering process in the weakly nonlinear regime. Typically, measurements of backscattered Stokes intensity (the dependent variable) are made at a number of predetermined fixed frequencies covering the design measurand range of the apparatus and combined to yield an estimate of the position of the extremum. The measurand can then be found because its relationship to the position of the extremum is assumed known. We present analytical expressions relating the relative error in the extremum position to experimental errors in the dependent variable. This is done for two cases: (i) a simple non-parametric estimate of the mean based on moments and (ii) the case in which a least squares technique is used to fit a Lorentzian to the data. The question of statistical bias in the estimates is discussed and in the second case we go further and present for the first time a general method by which the probability density function (PDF) of errors in the fitted parameters can be obtained in closed form in terms of the PDFs of the errors in the noisy data.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel technology for simultaneous and independent measurement of dual parameters is proposed and experimented. The length of a single fibre Bragg grating (FBG) is divided into two parts. The temperature variation and another measurand can be measured independently and simultaneously, and the thermal effect can be erased with great ease. © 2005 Elsevier Ltd. All rights reserved.