988 resultados para diagnostic imaging


Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT: BACKGROUND: Cardiovascular magnetic resonance (CMR) has favorable characteristics for diagnostic evaluation and risk stratification of patients with known or suspected CAD. CMR utilization in CAD detection is growing fast. However, data on its cost-effectiveness are scarce. The goal of this study is to compare the costs of two strategies for detection of significant coronary artery stenoses in patients with suspected coronary artery disease (CAD): 1) Performing CMR first to assess myocardial ischemia and/or infarct scar before referring positive patients (defined as presence of ischemia and/or infarct scar to coronary angiography (CXA) versus 2) a hypothetical CXA performed in all patients as a single test to detect CAD. METHODS: A subgroup of the European CMR pilot registry was used including 2,717 consecutive patients who underwent stress-CMR. From these patients, 21% were positive for CAD (ischemia and/or infarct scar), 73% negative, and 6% uncertain and underwent additional testing. The diagnostic costs were evaluated using invoicing costs of each test performed. Costs analysis was performed from a health care payer perspective in German, United Kingdom, Swiss, and United States health care settings. RESULTS: In the public sectors of the German, United Kingdom, and Swiss health care systems, cost savings from the CMR-driven strategy were 50%, 25% and 23%, respectively, versus outpatient CXA. If CXA was carried out as an inpatient procedure, cost savings were 46%, 50% and 48%, respectively. In the United States context, cost savings were 51% when compared with inpatient CXA, but higher for CMR by 8% versus outpatient CXA. CONCLUSION: This analysis suggests that from an economic perspective, the use of CMR should be encouraged as a management option for patients with suspected CAD.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Diagnostic and therapeutic aspects of human infection with Leishmania (Viannia) braziliensis found in the littoral forest of the state of Bahia are reviewed. There is pressing need for alternative cheap oral drug therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to illustrate the chest radiographs (CR) and CT imaging features and sequential findings of cavitary necrosis in complicated childhood pneumonia. Among 30 children admitted in the Pediatric Intensive Care Unit for persistent or progressive pneumonia, respiratory distress or sepsis despite adequate antibiotic therapy, a study group of 9 children (5 girls and 4 boys; mean age 4 years) who had the radiographic features and CT criteria for cavitary necrosis complicated pneumonia was identified. The pathogens identified were Streptococcus pneumoniae( n=4), Aspergillus( n=2), Legionella( n=1), and Staphylococcus aureus( n=1). Sequential CR and CT scans were retrospectively reviewed. Follow-up CR and CT were evaluated for persistent abnormalities. Chest radiographs showed consolidations in 8 of the 9 patients. On CT examination, cavitary necrosis was localized to 1 lobe in 2 patients and 7 patients showed multilobar or bilateral areas of cavitary necrosis. In 3 patients of 9, the cavitary necrosis was initially shown on CT and visualization by CR was delayed by a time span varying from 5 to 9 days. In all patients with cavities, a mean number of five cavities were seen on antero-posterior CR, contrasting with the multiple cavities seen on CT. Parapneumonic effusions were shown by CR in 3 patients and in 5 patients by CT. Bronchopleural fistulae were demonstrated by CT alone ( n=3). No purulent pericarditis was demonstrated. The CT scan displayed persistent residual pneumatoceles of the left lower lobe in 2 patients. Computed tomography is able to define a more specific pattern of abnormalities than conventional CR in children with necrotizing pneumonia and allows an earlier diagnosis of this rapidly progressing condition. Lung necrosis and cavitation may also be associated with Aspergillus or Legionella pneumonia in the pediatric population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Coronary MR imaging is a promising noninvasive technique for the combined assessment of coronary artery anatomy and function. Anomalous coronary arteries and aneurysms can reliably be assessed in clinical practice using coronary MR imaging and the presence of significant left main or proximal multivessel coronary artery disease detected. Technical challenges that need to be addressed are further improvements in motion suppression and abbreviated scanning times aimed at improving spatial resolution and patient comfort. The development of new and specific contrast agents, high-field MR imaging with improved spatial resolution, and continued progress in MR imaging methods development will undoubtedly lead to further progress toward the noninvasive and comprehensive assessment of coronary atherosclerotic disease.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

RESUME Introduction : La prophylaxie du système nerveux central lors d'un diagnostic de leucémie lymphoblastique aiguë de l'enfant a permis de réduire le risque de rechute mais a été associée dans certains cas à des neurotoxicités cliniques ou des anomalies radiologiques. Des moyens de prédire ces neurotoxicités font défaut, en particulier en raison de l'absence de corrélation claire entre les signes cliniques et les images radiologiques. Quelques auteurs ont suggéré que les taux de protéine basique de la myéline (MBP) mesurés dans le liquide céphalo-rachidien pouvaient avoir un intérêt dans ce contexte. Uné étude rétrospective de ces taux en relation avec des données cliniques et radiologiques est présentée dans ce travail. Matériel et Méthodes : Les taux de MBP mesurés dans le liquide céphalo-rachidien lors d'administration de chimiothérapie intrathécale, les examens cliniques neurologiques et les rapports radiologiques ont été rétrospectivement étudiés chez nos patients. Les données concernant des difficultés académiques éventuelles, ainsi que le niveau académique atteint ont été récoltées par l'intermédiaire de contacts téléphoniques réguliers organisés dans le cadre du suivi à long terme de nos patients. Résultats : Un total de 1248 dosages de MBP chez 83 patients, 381 examens neurologiques chez 34 patients et 69 rapports d'investigations neuroradiologiques chez 27 patients ont été analysés. Cinquante-deux patients ont eut au moins un taux anormal de MBP. Des anomalies radiologiques ont été décrites chez 47% de ces patients, parmi lesquels 14% ont présenté des difficultés scolaires sous une forme ou sous une autre. La proportion de patients ayant présenté des difficultés scolaires dans les groupes avec taux de MBP normal mais sans anomalies radiologiques décrites ou sans investigations radiologiques étaient respectivement de 0% et 3%, inférieurs dans tous les cas au groupe avec des taux normaux de MBP (100%, 22% and 5% respectivement). Discussion : Tout en prenant en compte les limitations dues à l'aspect rétrospectif de cette étude, nous avons conclu à une utilité limitée de ces dosages systématiques comme indicateur d'une neurotoxicité induite parle traitement dans le contexte de nos patients oncologiques. ABSTRACT Introduction : Central nervous system (CSF) prophylaxis of childhood acute lymphoblastic leukemia has dropped rates of relapses but has been associated wíth neurotoxicity and imaging abnormalities. Predictors of neurotoxícity are lacking, because of inconsistency between clinical symptoms and imaging. Some have suggested CSF Myelin Basic Protein (MBP) levels to be of potential interest. A retrospective analysis of MBP levels in correlation with clinical and radiological data is presented. Materials and Methods : MBP levels obtained at the time of intrathecals, charts, and neuroradiology reports were retrospectively analyzed. Academic achievement data were obtained from phone contacts with patients and families. Results : We retrieved 1248 dosages of MBP in 83 patients, 381 neurological exams in 34 patients and 69 neuroradiological investigations in 27 patients. Fifty-two patients had abnormal MBP levels. Radiological anomalies were present in 47% of those investigated, 14% of them having school difficulties. Proportions of patients with school difficulties in the groups with abnormal MBP levels but no radiological anomalies or with no radiological investigations were 0% and 3% respectively, which was lower than in the group of patients with normal MBP levels (100%, 22% and 5% respectively). Discussion : Notwithstanding the retrospective character of our study, we conclude that there is limited usefulness of systematic dosage of MBP as indicator of treatment-induced neurotoxicity in ALL patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In recent years, modern techniques of medical imaging such as MDCT (multidetector-computed tomography) and MRI (magnetic resonance imaging) have pioneered post mortem (pm) investigations, especially in forensic medicine. Particularly pm angiography permits investigating the vascular system in a way which is not possible by performing only conventional autopsy. Beside these radiological methods, other modem visualizing techniques like the three dimensional (3D) surface scan have been implemented in order perform reconstructions of complex cases. By the use of pm imaging techniques, more objective and accurate documentations can be realized that permit an increase of quality in forensic investigations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose. We evaluated the influence of the time between low-dose gadolinium (Gd) contrast administration and coronary vessel wall enhancement (LGE) detected by 3T magnetic resonance imaging (MRI) in healthy subjects and patients with coronary artery disease (CAD). Materials and Methods. Four healthy subjects (4 men, mean age 29 ± 3 years and eleven CAD patients (6 women, mean age 61 ± 10 years) were studied on a commercial 3.0 Tesla (T) whole-body MR imaging system (Achieva 3.0 T; Philips, Best, The Netherlands). T1-weighted inversion-recovery coronary magnetic resonance imaging (MRI) was repeated up to 75 minutes after administration of low-dose Gadolinium (Gd) (0.1 mmol/kg Gd-DTPA). Results. LGE was seen in none of the healthy subjects, however in all of the CAD patients. In CAD patients, fifty-six of 62 (90.3%) segments showed LGE of the coronary artery vessel wall at time-interval 1 after contrast. At time-interval 2, 34 of 42 (81.0%) and at time-interval 3, 29 of 39 evaluable segments (74.4%) were enhanced. Conclusion. In this work, we demonstrate LGE of the coronary artery vessel wall using 3.0 T MRI after a single, low-dose Gd contrast injection in CAD patients but not in healthy subjects. In the majority of the evaluated coronary segments in CAD patients, LGE of the coronary vessel wall was already detectable 30-45 minutes after administration of the contrast agent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: CMR has recently emerged as a robust and reliable technique to assess coronary artery disease (CAD). A negative perfusion CMR test predicts low event rates of 0.3-0.5%/year. Invasive coronary angiography (CA) remains the "gold standard" for the evaluation of CAD in many countries.Objective: Assessing the costs of the two strategies in the European CMR registry for the work-up of known or suspected CAD from a health care payer perspective. Strategy 1) a CA to all patients or 2) a CA only to patients who are diagnosed positive for ischemia in a prior CMR.Method and results: Using data of the European CMR registry (20 hospitals, 11'040 consecutive patients) we calculated the proportion of patients who were diagnosed positive (20.6%), uncertain (6.5%), and negative (72.9%) after the CMR test in patients with known or suspected CAD (n=2'717). No other medical test was performed to patients who were negative for ischemia. Positive diagnosed patients had a coronary angiography. Those with uncertain diagnosis had additional tests (84.7%: stress echocardiography, 13.1%: CCT, 2.3% SPECT), these costs were added to the CMR strategy costs. Information from costs for tests in Germany and Switzerland were used. A sensibility analysis was performed for inpatient CA. For costs see figure. Results - costs.Discussion: The CMR strategy costs less than the CA strategy for the health insurance systems both, in Germany and Switzerland. While lower in costs, the CMR strategy is a non-invasive one, does not expose to radiation, and yields additional information on cardiac function, viability, valves, and great vessels. Developing the use of CMR instead of CA might imply some reduction in costs together with superior patient safety and comfort, and a better utilization of resources at the hospital level. Document introduit le : 01.12.2011

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'instabilité gléno-humérale revêt de nombreuses formes cliniques. La classification basée sur l'étiologie (lésion de l'appareil capsuloligamentaire ou dysfonction d'origine musculaire) permet d'orienter le traitement. Lors d'Instabilité traumatique, avec récidive de luxation, la réparation chirurgicale donne de bons résultats. Les cas d'instabilité sur dysfonction musculaire, avec composante volontaire, restent du domaine de la rééducation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In type I diabetes mellitus, islet transplantation provides a moment-to-moment fine regulation of insulin. Success rates vary widely, however, necessitating suitable methods to monitor islet delivery, engraftment and survival. Here magnetic resonance-trackable magnetocapsules have been used simultaneously to immunoprotect pancreatic beta-cells and to monitor, non-invasively in real-time, hepatic delivery and engraftment by magnetic resonance imaging (MRI). Magnetocapsules were detected as single capsules with an altered magnetic resonance appearance on capsule rupture. Magnetocapsules were functional in vivo because mouse beta-cells restored normal glycemia in streptozotocin-induced diabetic mice and human islets induced sustained C-peptide levels in swine. In this large-animal model, magnetocapsules could be precisely targeted for infusion by using magnetic resonance fluoroscopy, whereas MRI facilitated monitoring of liver engraftment over time. These findings are directly applicable to ongoing improvements in islet cell transplantation for human diabetes, particularly because our magnetocapsules comprise clinically applicable materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Morphological description of sand flies has remained a neglected area. The different organs used in taxonomy have not yet been described adequately with the scanning electron microscopy (SEM). We have examined the external genital structures of females of three Old World phlebotomine sand flies under SEM and recorded the morphological variations of the organs. We have found the female external genital structures of the three species varied considerably in morphology. The importance of the female external genital structures in sand fly identification is indicated

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L'infarctus rénal, le plus souvent segmentalre, reste un diagnostic difficile et souvent méconnu. La présentation clinique est peu spécifique mais la triade douleurs du flanc, abdominales ou dorso-lombaires, élévation des LDH et hématurie microscopique, survenant sur un terrain à risque thrombo-embolique, doit faire rechercher ce diagnostic. La lithiase urinaire, la pyélonéphrite aiguë et les pathologies intra-abdominales aiguës sont les principaux diagnostics différentiels. Une étiologie cardiaque (FA, anévrismes septaux, valvulopathies mitrales et endocardites) est présente dans la majorité des cas. Le CT-scan avec injection de produit de contraste représente l'examen diagnostique de choix. L'anticoagulatlon ou la fibrinolyse constituent le traitement de première intention quelle que soit la gravité de l'occlusion vasculaire.