976 resultados para cofenetic correlation coefficient


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Previous studies suggest that the activation (autophosphorylation) of dsRNA-dependent protein kinase (PKR) can stimulate protein degradation, and depress protein synthesis in skeletal muscle through phosphorylation of the translation initiation factor 2 (eIF2) on the alpha-subunit. To understand whether these mediators are important in muscle wasting in cancer patients, levels of the phospho forms of PKR and eIF2alpha have been determined in rectus abdominus muscle of weight losing patients with oesophago-gastric cancer, in comparison with healthy controls. Levels of both phospho PKR and phospho eIF2alpha were significantly enhanced in muscle of cancer patients with weight loss irrespective of the amount and there was a linear relationship between phosphorylation of PKR and phosphorylation of eIF2alpha (correlation coefficient 0.76, P=0.005). This suggests that phosphorylation of PKR led to phosphorylation of eIF2alpha. Myosin levels decreased as the weight loss increased, and there was a linear relationship between myosin expression and the extent of phosphorylation of eIF2alpha (correlation coefficient 0.77, P=0.004). These results suggest that phosphorylation of PKR may be an important initiator of muscle wasting in cancer patients.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An increasing number of neuroimaging studies are concerned with the identification of interactions or statistical dependencies between brain areas. Dependencies between the activities of different brain regions can be quantified with functional connectivity measures such as the cross-correlation coefficient. An important factor limiting the accuracy of such measures is the amount of empirical data available. For event-related protocols, the amount of data also affects the temporal resolution of the analysis. We use analytical expressions to calculate the amount of empirical data needed to establish whether a certain level of dependency is significant when the time series are autocorrelated, as is the case for biological signals. These analytical results are then contrasted with estimates from simulations based on real data recorded with magnetoencephalography during a resting-state paradigm and during the presentation of visual stimuli. Results indicate that, for broadband signals, 50-100 s of data is required to detect a true underlying cross-correlations coefficient of 0.05. This corresponds to a resolution of a few hundred milliseconds for typical event-related recordings. The required time window increases for narrow band signals as frequency decreases. For instance, approximately 3 times as much data is necessary for signals in the alpha band. Important implications can be derived for the design and interpretation of experiments to characterize weak interactions, which are potentially important for brain processing.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose. To evaluate the repeatability and reproducibility of subfoveal choroidal thickness (CT) calculations performed manually using optical coherence tomography (OCT). Methods. The CT was imaged in vivo at each of two visits on 11 healthy volunteers (mean age, 35.72 ± 13.19 years) using the spectral domain OCT. CT was manually measured after applying ImageJ processing filters on 15 radial subfoveal scans. Each radial scan was spaced 12° from each other and contained 2500 A-scans. The coefficient of variability, coefficient of repeatability (CoR), coefficient of reproducibility, and intraclass correlation coefficient determined the reproducibility and repeatability of the calculation. Axial length (AL) and mean spherical equivalent refractive error were measured with the IOLMaster and an open view autorefractor to study their potential relationship with CT. Results. The within-visit and between-visit coefficient of variability, CoR, coefficient of reproducibility, and intraclass correlation coefficient were 0.80, 2.97% 2.44%, and 99%, respectively. The subfoveal CT correlated significantly with AL (R = -0.60, p = 0.05). Conclusions. The subfoveal CT could be measured manually in vivo using OCT and the readings obtained from the healthy subjects evaluated were repeatable and reproducible. It is proposed that OCT could be a useful instrument to perform in vivo assessment and monitoring of CT changes in retinal disease. The preliminary results suggest a negative correlation between subfoveal CT and AL in such a way that it decreases with increasing AL but not with refractive error.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

CONTEXT: The homeless are a significant group within society, which is increasing in size. They have demonstrably greater physical and mental health needs than the housed, and yet often have difficulty accessing primary health care. Medical 'reluctance' to look after homeless people is increasingly suggested as part of the problem. Medical education may have a role in ameliorating this. OBJECTIVES: This paper reports on the development and validation of a questionnaire specifically developed to measure medical students' attitudes towards the homeless. METHOD AND RESULTS: The Attitudes Towards the Homeless Questionnaire, developed using the views of over 370 medical students, was shown to have a Pearson test-retest reliability correlation coefficient of 0.8 and a Cronbach's alpha coefficient of 0.74. CONCLUSIONS: The Attitudes Towards the Homeless Questionnaire appears to be a valid and reliable instrument, which can measure students' attitudes towards the homeless. It could be a useful tool in assessing the effectiveness of educational interventions.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose: To develop a questionnaire that subjectively assesses near visual function in patients with 'accommodating' intraocular lenses (IOLs). Methods: A literature search of existing vision-related quality-of-life instruments identified all questions relating to near visual tasks. Questions were combined if repeated in multiple instruments. Further relevant questions were added and item interpretation confirmed through multidisciplinary consultation and focus groups. A preliminary 19-item questionnaire was presented to 22 subjects at their 4-week visit post first eye phacoemulsification with 'accommodative' IOL implantation, and again 6 and 12 weeks post-operatively. Rasch Analysis, Frequency of Endorsement, and tests of normality (skew and kurtosis) were used to reduce the instrument. Cronbach's alpha and test-retest reliability (intraclass correlation coefficient, ICC) were determined for the final questionnaire. Construct validity was obtained by Pearson's product moment correlation (PPMC) of questionnaire scores to reading acuity (RA) and to Critical Print Size (CPS) reading speed. Criterion validity was obtained by receiver operating characteristic (ROC) curve analysis and dimensionality of the questionnaire was assessed by factor analysis. Results: Rasch Analysis eliminated nine items due to poor fit statistics. The final items have good separation (2.55), internal consistency (Cronbach's α = 0.97) and test-retest reliability (ICC = 0.66). PPMC of questionnaire scores with RA was 0.33, and with CPS reading speed was 0.08. Area under the ROC curve was 0.88 and Factor Analysis revealed one principal factor. Conclusion: The pilot data indicates the questionnaire to be internally consistent, reliable and a valid instrument that could be useful for assessing near visual function in patients with 'accommodating' IOLS. The questionnaire will now be expanded to include other types of presbyopic correction. © 2007 British Contact Lens Association.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The density of the diffuse, primitive and classic beta-amyloid (Abeta) deposits and the incidence of large and small diameter blood vessels was studied in the upper laminae of the frontal cortex of 10 patients with sporadic Alzheimer’s disease (AD). The data were analysed using the partial correlation coefficient to determine whether variations in the density of Abeta deposit subtypes along the cortex were related to blood vessels. Significant correlations between the density of the diffuse or primitive Abeta deposits and blood vessels were found in only a small number of patients. However, the classic Abeta deposits were positively correlated with the large blood vessels in all 10 patients, the correlations remaining when the effects of gyral location and mutual correlations between Abeta deposits were removed. These results suggest that the larger blood vessels are involved specifically in the formation of the classic Abeta deposits and are less important in the formation of the diffuse and primitive deposits.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In the center of today's continued and rapid technological change and ever competitive environment of the next millennium, manufacturers must realize that unless they are ready to consider and evaluate new technologies brought onto them, they may fail to adequately respond to the challenges that lie ahead of them. This research was designed to determine the consistency of the perceptions of technical and non-technical administrators, in manufacturing environment, towards technological change and group technology as an advanced manufacturing system. This research has included a review of literature with references to technological change, justification and implementation processes, and various manufacturing systems including group technology and its benefits. This research has used the research method of empirical analysis (quantitative) and case studies (qualitative) to research perceptions of technical and non-technical administrators towards technological change and group technology. Sixty-four (64) technical and fifty-one (51) nontechnical administrators from fifty (50) manufacturing organizations in the United States of America responded to the mail survey questionnaire used in this research. Responses were analyzed using the Repeated Measures ANOVA procedure to compare mean responses of each group. Two correlation analyses, Cronback Coefficient Alpha and Pearson Correlation Coefficient, were also performed to determine the reliability of the questionnaire as well as the degree of correlation of perceptions between these two groups. This research, through the empirical analysis, has found that perceptions of the technical and non-technical administrators towards group technology were not consistent. In other words, they did not perceive the benefits of group technology in the same manner to the overall organizational performance. This finding was significant since it provided the first clear and comprehensive view of the technical and non-technical administrators' perception towards group technology and technological change, in Food Equipment Manufacturer Industry, in United States of America. In addition, a number of cases were analyzed and the results have supported those of the quantitative analysis. Therefore, this research not only has provided basic data, which was unavailable prior to this investigation, but it also provided a basis for future studies.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An array of in-line curvature sensors on a garment is used to monitor the thoracic and abdominal movements of a human during respiration. The results are used to obtain volumetric changes of the human torso in agreement with a spirometer used simultaneously at the mouth. The array of 40 in-line fiber Bragg gratings is used to produce 20 curvature sensors at different locations, each sensor consisting of two fiber Bragg gratings. The 20 curvature sensors and adjoining fiber are encapsulated into a low-temperature-cured synthetic silicone. The sensors are wavelength interrogated by a commercially available system from Moog Insensys, and the wavelength changes are calibrated to recover curvature. A three-dimensional algorithm is used to generate shape changes during respiration that allow the measurement of absolute volume changes at various sections of the torso. It is shown that the sensing scheme yields a volumetric error of 6%. Comparing the volume data obtained from the spirometer with the volume estimated with the synchronous data from the shape-sensing array yielded a correlation value 0.86 with a Pearson's correlation coefficient p <0.01.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: To validate a new miniaturised, open-field wavefront device which has been developed with the capacity to be attached to an ophthalmic surgical microscope or slit-lamp. SETTING: Solihull Hospital and Aston University, Birmingham, UK DESIGN: Comparative non-interventional study. METHODS: The dynamic range of the Aston Aberrometer was assessed using a calibrated model eye. The validity of the Aston Aberrometer was compared to a conventional desk mounted Shack-Hartmann aberrometer (Topcon KR1W) by measuring the refractive error and higher order aberrations of 75 dilated eyes with both instruments in random order. The Aston Aberrometer measurements were repeated five times to assess intra-session repeatability. Data was converted to vector form for analysis. RESULTS: The Aston Aberrometer had a large dynamic range of at least +21.0 D to -25.0 D. It gave similar measurements to a conventional aberrometer for mean spherical equivalent (mean difference ± 95% confidence interval: 0.02 ± 0.49D; correlation: r=0.995, p<0.001), astigmatic components (J0: 0.02 ± 0.15D; r=0.977, p<0.001; J45: 0.03 ± 0.28; r=0.666, p<0.001) and higher order aberrations RMS (0.02 ± 0.20D; r=0.620, p<0.001). Intraclass correlation coefficient assessments of intra-sessional repeatability for the Aston Aberrometer were excellent (spherical equivalent =1.000, p<0.001; astigmatic components J0 =0.998, p<0.001, J45=0.980, p<0.01; higher order aberrations RMS =0.961, p<0.001). CONCLUSIONS: The Aston Aberrometer gives valid and repeatable measures of refractive error and higher order aberrations over a large range. As it is able to measure continuously, it can provide direct feedback to surgeons during intraocular lens implantations and corneal surgery as to the optical status of the visual system.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Purpose - Anterior segment optical coherent tomography (AS-OCT) is used to further examine previous reports that ciliary muscle thickness (CMT) is increased in myopic eyes. With reference to temporal and nasal CMT, interrelationships between biometric and morphological characteristics of anterior and posterior segments are analysed for British-White and British-South-Asian adults with and without myopia. Methods - Data are presented for the right eyes of 62 subjects (British-White n = 39, British-South-Asian n = 23, aged 18–40 years) with a range of refractive error (mean spherical error (MSE (D)) -1.74 ± 3.26; range -10.06 to +4.38) and separated into myopes (MSE (D) <-0.50, range -10.06 to -0.56; n = 30) and non-myopes (MSE (D) =-0.50, -0.50 to +4.38; n = 32). Temporal and nasal ciliary muscle cross-sections were imaged using a Visante AS-OCT. Using Visante software, manual measures of nasal and temporal CMT (NCMT and TCMT respectively) were taken in successive posterior 1 mm steps from the scleral spur over a 3 mm distance (designated NCMT1, TCMT1 et seq). Measures of axial length and anterior chamber depth were taken with an IOLMaster biometer. MSE and corneal curvature (CC) measurements were taken with a Shin-Nippon auto-refractor. Magnetic resonance imaging was used to determine total ocular volume (OV) for 31 of the original subject group. Statistical comparisons and analyses were made using mixed repeated measures anovas, Pearson's correlation coefficient and stepwise forward multiple linear regression. Results - MSE was significantly associated with CMT, with thicker CMT2 and CMT3 being found in the myopic eyes (p = 0.002). In non-myopic eyes TCMT1, TCMT2, NCMT1 and NCMT2 correlated significantly with MSE, AL and OV (p < 0.05). In contrast, myopic eyes failed generally to exhibit a significant correlation between CMT, MSE and axial length but notably retained a significant correlation between OV, TCMT2, TCMT3, NCMT2 and NCMT3 (p < 0.05). OV was found to be a significantly better predictor of TCMT2 and TCMT3 than AL by approximately a factor of two (p < 0.001). Anterior chamber depth was significantly associated with both temporal and nasal CMT2 and CMT3; TCMT1 correlated positively with CC. Ethnicity had no significant effect on differences in CMT. Conclusions - Increased CMT is associated with myopia. We speculate that the lack of correlation in myopic subjects between CMT and axial length, but not between CMT and OV, is evidence that disrupted feedback between the fovea and ciliary apparatus occurs in myopia development.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We analyze theoretically and empirically the impact of the shadow economy on entrepreneurial entry, utilising 1998-2005 individual-level Global Entrepreneurship Monitor data merged with macro level variables. A simple correlation coefficient suggests a positive linear link between the size of the shadow economy and entrepreneurial entry. However, this masks more complex relationships. With appropriate controls and instrumenting for potential endogeneity where required, the impact of the shadow economy on entry is found to be negative, based on a linear specification. Moreover, there is also evidence of nonlinearity: entrepreneurial entry is least likely when the shadow economy is of medium size. We attribute the negative effects of shadow economy on entry to perceived strong competition faced by new entrants when the shadow economy is widespread. At the individual level, an extensive shadow economy has a more negative impact on respondents who are risk averse. In addition, in the economies where property rights are strong, the negative impact of the shadow economy is weaker.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: The aim was to investigate the effect on the measured amplitude of accommodation and repeatability of using the minus lens technique with the target at distance or near. Methods: Forty-three students (average age: 21.17 ± 1.50 years, 35 female) had their amplitude of accommodation measured with minus lenses on top of their distance correction in a trial frame with the target at far (6.0m) or near (0.4m). The minus lens power was gradually added with steps of 0.25D. Measurements were taken on two occasions at each distance, which were separated by a time interval of at least 24 hours. Results: The measured amplitude at six metres was significantly lower than that with the target at 40cm, by 1.56 ± 1.17D (p < 0.001) and this varied between individuals (r = 0.716, intraclass correlation coefficient = 0.439). With either target distance, repeated measurement was highly correlated (r > 0.9) but the agreement was better at 6.0m (±0.74D) than at 40cm (± 0.92D). Conclusion: The measurements of the amplitude of accommodation with the minus lens technique using targets at far or near are not comparable and the difference between the target distances may provide clinically relevant information. © 2013 Optometrists Association Australia.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In many of the Statnotes described in this series, the statistical tests assume the data are a random sample from a normal distribution These Statnotes include most of the familiar statistical tests such as the ‘t’ test, analysis of variance (ANOVA), and Pearson’s correlation coefficient (‘r’). Nevertheless, many variables exhibit a more or less ‘skewed’ distribution. A skewed distribution is asymmetrical and the mean is displaced either to the left (positive skew) or to the right (negative skew). If the mean of the distribution is low, the degree of variation large, and when values can only be positive, a positively skewed distribution is usually the result. Many distributions have potentially a low mean and high variance including that of the abundance of bacterial species on plants, the latent period of an infectious disease, and the sensitivity of certain fungi to fungicides. These positively skewed distributions are often fitted successfully by a variant of the normal distribution called the log-normal distribution. This statnote describes fitting the log-normal distribution with reference to two scenarios: (1) the frequency distribution of bacterial numbers isolated from cloths in a domestic environment and (2), the sizes of lichenised ‘areolae’ growing on the hypothalus of Rhizocarpon geographicum (L.) DC.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In previous Statnotes, many of the statistical tests described rely on the assumption that the data are a random sample from a normal or Gaussian distribution. These include most of the tests in common usage such as the ‘t’ test ), the various types of analysis of variance (ANOVA), and Pearson’s correlation coefficient (‘r’) . In microbiology research, however, not all variables can be assumed to follow a normal distribution. Yeast populations, for example, are a notable feature of freshwater habitats, representatives of over 100 genera having been recorded . Most common are the ‘red yeasts’ such as Rhodotorula, Rhodosporidium, and Sporobolomyces and ‘black yeasts’ such as Aurobasidium pelculans, together with species of Candida. Despite the abundance of genera and species, the overall density of an individual species in freshwater is likely to be low and hence, samples taken from such a population will contain very low numbers of cells. A rare organism living in an aquatic environment may be distributed more or less at random in a volume of water and therefore, samples taken from such an environment may result in counts which are more likely to be distributed according to the Poisson than the normal distribution. The Poisson distribution was named after the French mathematician Siméon Poisson (1781-1840) and has many applications in biology, especially in describing rare or randomly distributed events, e.g., the number of mutations in a given sequence of DNA after exposure to a fixed amount of radiation or the number of cells infected by a virus given a fixed level of exposure. This Statnote describes how to fit the Poisson distribution to counts of yeast cells in samples taken from a freshwater lake.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An HPLC method has been developed and validated for the rapid determination of mercaptopurine and four of its metabolites; thioguanine, thiouric acid, thioxanthine and methylmercaptopurine in plasma and red blood cells. The method involves a simple treatment procedure based on deproteinisation by perchloric acid followed by acid hydrolysis and heating for 45min at 100 degrees C. The developed method was linear over the concentration range studied with a correlation coefficient >0.994 for all compounds in both plasma and erythrocytes. The lower limits of quantification were 13, 14, 3, 2, 95pmol/8 x 10(8) RBCs and 2, 5, 2, 3, 20ng/ml plasma for thioguanine, thiouric acid, mercaptopurine, thioxanthine and methylmercaptopurine, respectively. The method described is selective and sensitive enough to analyse the different metabolites in a single run under isocratic conditions. Furthermore, it has been shown to be applicable for monitoring these metabolites in paediatric patients due to the low volume requirement (200microl of plasma or erythrocytes) and has been successfully applied for investigating population pharmacokinetics, pharmacogenetics and non-adherence to therapy in these patients.