985 resultados para carotid arteries
Resumo:
Human arteries affected by atherosclerosis are characterized by altered wall viscoelastic properties. The possibility of noninvasively assessing arterial viscoelasticity in vivo would significantly contribute to the early diagnosis and prevention of this disease. This paper presents a noniterative technique to estimate the viscoelastic parameters of a vascular wall Zener model. The approach requires the simultaneous measurement of flow variations and wall displacements, which can be provided by suitable ultrasound Doppler instruments. Viscoelastic parameters are estimated by fitting the theoretical constitutive equations to the experimental measurements using an ARMA parameter approach. The accuracy and sensitivity of the proposed method are tested using reference data generated by numerical simulations of arterial pulsation in which the physiological conditions and the viscoelastic parameters of the model can be suitably varied. The estimated values quantitatively agree with the reference values, showing that the only parameter affected by changing the physiological conditions is viscosity, whose relative error was about 27% even when a poor signal-to-noise ratio is simulated. Finally, the feasibility of the method is illustrated through three measurements made at different flow regimes on a cylindrical vessel phantom, yielding a parameter mean estimation error of 25%.
Resumo:
Instead of standard rigid thoracoscopes, we used a modified gastroscope for video assistance during 12 minimally invasive left internal mammary harvesting. Flexibility and remote control of its last centimeters give to the gastroscope a total freedom of movements, and perfect positioning in every direction. The scope is equipped with cold light, a suction canal and an irrigation canal, which allow for in situ washing without needing to remove it from the thoracic cavity. Thanks to these advantages, vision and lighting are always perfect.
Resumo:
OBJECTIVES: The goal was to test 2 hypotheses: first, that coronary endothelial function can be measured noninvasively and abnormal function detected using clinical 3.0-T magnetic resonance imaging (MRI); and second, that the extent of local coronary artery disease (CAD), in a given patient, is related to the degree of local abnormal coronary endothelial function. BACKGROUND: Abnormal endothelial function mediates the initiation and progression of atherosclerosis and predicts cardiovascular events. However, direct measures of coronary endothelial function have required invasive assessment. METHODS: The MRI was performed in 20 healthy adults and 17 patients with CAD. Cross-sectional coronary area and blood flow were quantified before and during isometric handgrip exercise, an endothelial-dependent stressor. In 10 severe, single-vessel CAD patients, paired endothelial function was measured in the artery with severe stenosis and the contralateral artery with minimal disease. RESULTS: In healthy adults, coronary arteries dilated and flow increased with stress. In CAD patients, coronary artery area and blood flow decreased with stress (both p </= 0.02). In the paired study, coronary artery area and blood flow failed to increase during exercise in the mildly diseased vessel, but both area (p = 0.01) and blood flow (p = 0.02) decreased significantly in the severely diseased, contralateral artery. CONCLUSIONS: Endothelial-dependent coronary artery dilation and increased blood flow in healthy subjects, and their absence in CAD patients, can now be directly visualized and quantified noninvasively. Local coronary endothelial function differs between severely and mildly diseased arteries in a given CAD patient. This novel, safe method may offer new insights regarding the importance of local coronary endothelial function and improved risk stratification in patients at risk for and with known CAD.
Resumo:
OBJECTIVE: Absent or reverse end-diastolic flow (Doppler II/III) in umbilical artery is correlated with poor perinatal outcome, particularly in intrauterine growth restricted (IUGR) fetuses. The optimal timing of delivery is still controversial. We studied the short- and long-term morbidity and mortality among these children associated with our defined management. STUDY DESIGN: Sixty-nine IUGR fetuses with umbilical Doppler II/III were divided into three groups; Group 1, severe early IUGR, no therapeutic intervention (n = 7); Group 2, fetuses with pathological biophysical profile, immediate delivery (n = 35); Group 3, fetuses for which expectant management had been decided (n = 27). RESULTS: In Group 1, stillbirth was observed after a mean delay of 6.3 days. Group 2 delivered at an average of 31.6 weeks and two died in the neonatal period (6%). In Group 3 after a mean delay of 8 days, average gestational age at delivery was 31.7 weeks; two intra uterine and four perinatal deaths were observed (22%). Long-term follow-up revealed no sequelae in 25/31 (81%) and 15/18 (83%), and major handicap occurred in 1 (3%) and 2 patients (11%), respectively, for Groups 2 and 3. CONCLUSION: Fetal mortality was observed in 22% of this high risk group. After a mean period of follow-up of 5 years, 82% of infants showed no sequelae. According to our management, IUGR associated with umbilical Doppler II or III does not show any benefit from an expectant management in term of long-term morbidity.
Resumo:
INTRODUCTION: Cerebrovascular changes are rarely discussed in patients with hemimegalencephaly. These alterations have previously been associated with epileptical activity. CASE: We report the case of a 36-week gestation neonate presenting with total right hemimegalencephaly, as demonstrated by a magnetic resonance imaging (MRI) performed in the first days of life. Perfusion-weighted imaging displayed a clear hypervascularization of the right hemisphere. Diffusion-tensor imaging showed an arrangement of white matter fibers concentrically around the ventricle on the right hemisphere. AngioMRI showed an obvious asymmetry in the size of the middle cerebral arteries, with the right middle cerebral artery being prominent. The baby was free of clinical seizures during his first week of life. An electroencephalogram at that time displayed an asymmetric background activity, but no electrical seizures. CONCLUSION: Perfusion anomalies in hemimegalencephaly may not necessarily be related to epileptical activity, but may be related to vessel alterations.
Resumo:
Although it has been clearly demonstrated that venous thromboembolism is associated with an increased risk of subsequent overt cancer and arterial cardiovascular events in comparison with control populations, whether this association also applies to patients with isolated (ie, without concomitant involvement of the deep vein system) superficial vein thrombosis (SVT) in the legs is unknown. In 737 consecutive patients with isolated SVT not involving the sapheno-femoral junction, we conducted a retrospective investigation to assess the rate of cancer and that of arterial cardiovascular events occurring during follow-up. The event rates were compared with those occurring in 1438 controls having comparable characteristics. Both cases and controls were followed-up for an average period of 26 ± 8 months (range, 3-45). Malignancy was diagnosed in 26 cases (3.5%) and 56 controls (3.9%), leading to a hazard ratio of 0.86 (95% confidence interval, 0.55%-1.35%). Arterial cardiovascular events occurred in 32 cases (4.3%) and 63 controls (4.4%), leading to a hazard ratio of 0.97 (95% confidence interval, 0.63%-1.50%). We conclude that the occurrence of isolated SVT in the legs does not place patients at an increased risk of malignancies or arterial cardiovascular events. Whether this conclusion also applies to patients whose thrombosis involves the sapheno-femoral junction remains to be demonstrated.
Resumo:
To enhance the clinical value of coronary magnetic resonance angiography (MRA), high-relaxivity contrast agents have recently been used at 3T. Here we examine a uniform bilateral shadowing artifact observed along the coronary arteries in MRA images collected using such a contrast agent. Simulations were performed to characterize this artifact, including its origin, to determine how best to mitigate this effect, and to optimize a data acquisition/injection scheme. An intraluminal contrast agent concentration model was used to simulate various acquisition strategies with two profile orders for a slow-infusion of a high-relaxivity contrast agent. Filtering effects from temporally variable weighting in k-space are prominent when a centric, radial (CR) profile order is applied during contrast infusion, resulting in decreased signal enhancement and underestimation of vessel width, while both pre- and postinfusion steady-state acquisitions result in overestimation of the vessel width. Acquisition during the brief postinfusion steady-state produces the greatest signal enhancement and minimizes k-space filtering artifacts.
Resumo:
The acquisition duration of most three-dimensional (3D) coronary magnetic resonance angiography (MRA) techniques is considerably prolonged, thereby precluding breathholding as a mechanism to suppress respiratory motion artifacts. Splitting the acquired 3D volume into multiple subvolumes or slabs serves to shorten individual breathhold duration. Still, problems associated with misregistration due to inconsistent depths of expiration and diaphragmatic drift during sustained respiration remain to be resolved. We propose the combination of an ultrafast 3D coronary MRA imaging sequence with prospective real-time navigator technology, which allows correction of the measured volume position. 3D volume splitting using prospective real-time navigator technology, was successfully applied for 3D coronary MRA in five healthy individuals. An ultrafast 3D interleaved hybrid gradient-echoplanar imaging sequence, including T2Prep for contrast enhancement, was used with the navigator localized at the basal anterior wall of the left ventricle. A 9-cm-thick volume, with in-plane spatial resolution of 1.1 x 2.2 mm, was acquired during five breathholds of 15-sec duration each. Consistently, no evidence of misregistration was observed in the images. Extensive contiguous segments of the left anterior descending coronary artery (48 +/- 18 mm) and the right coronary artery (75 +/- 5 mm) could be visualized. This technique has the potential for screening for anomalous coronary arteries, making it well suited as part of a larger clinical MR examination. In addition, this technique may also be applied as a scout scan, which allows an accurate definition of imaging planes for subsequent high-resolution coronary MRA.
Resumo:
PURPOSE OF REVIEW: To present the practical aspects of transcranial Doppler (TCD) and provide evidence supporting its use for the management of traumatic brain injury (TBI) patients. RECENT FINDINGS: TCD measures systolic, mean, and diastolic cerebral blood flow (CBF) velocities and calculates the pulsatility index from basal intracranial arteries. These variables reflect the brain circulation, provided there is control of potential confounding factors. TCD can be useful in patients with severe TBI to detect low CBF, for example, during intracranial hypertension, and to assess cerebral autoregulation. In the emergency room, TCD might complement brain computed tomography (CT) scan and clinical examination to screen patients at risk for further neurological deterioration after mild-to-moderate TBI. SUMMARY: The diagnostic value of TCD should be incorporated into other findings from multimodal brain monitoring and CT scan to optimize the bedside management of patients with TBI and help guide the choice of appropriate therapies.
Resumo:
Subarachnoid haemorrhage (SAH) is a form of stroke that is associated with substantial morbidity, often as a result of cerebral ischaemia that occurs in the following days. These delayed deficits in blood flow have been traditionally attributed to cerebral vasospasm (the narrowing of large arteries), which can lead to cerebral infarction and poor neurological outcome. Data from recent studies, however, show that treatment of vasospasm in patients with SAH, using targeted medication, does not translate to better neurological outcomes, and argue against vasospasm being the sole cause of the delayed ischaemic complications. Cerebral autoregulation-a mechanism that maintains stability of cerebral blood flow in response to changes in cerebral perfusion pressure-has been reported to fail after SAH, often before vasospasm becomes apparent. Failure of autoregulation, therefore, has been implicated in development of delayed cerebral ischaemia. In this Review, we summarize current knowledge about the clinical effect of disturbed cerebral autoregulation following aneurysmal SAH, with emphasis on development of delayed cerebral ischaemia and clinical outcome, and provide a critical assessment of studies of cerebral autoregulation in SAH with respect to the method of blood-flow measurement. Better understanding of cerebral autoregulation following SAH could reveal mechanisms of blood-flow regulation that could be therapeutically targeted to improve patient outcome.
Resumo:
Pharmacological treatment of hypertension represents a cost-effective way of preventing cardiovascular and renal complications. To benefit maximally from antihypertensive treatment, blood pressure should be brought to below 140/90 mmHg in every hypertensive patient, and even lower (< 130/80 mmHg) if diabetes or renal disease co-exists. Such targets cannot usually be reached using monotherapies. This is especially true in patients who present with a high cardiovascular risk. The co-administration of two agents acting by different mechanisms considerably increases the blood pressure control rate. Such combinations are not only efficacious, but are also well tolerated, and some fixed low-dose combinations even have a placebo-like tolerability. This is the case for the preparation containing the angiotensin-converting enzyme inhibitor perindopril (2 mg) and the diuretic indapamide (0.625 mg), a fixed low-dose combination that has been shown in controlled trials to be more effective than monotherapies in reducing albuminuria, regressing cardiac hypertrophy and improving the stiffness of large arteries. Using this combination to initiate antihypertensive therapy has been shown in a double-blind trial (Strategies of Treatment in Hypertension: Evaluation; STRATHE) to normalize blood pressure (< 140/90 mmHg) in significantly more patients (62%) than a sequential monotherapy approach based on atenolol, losartan and amlodipine (49%) and a stepped-care strategy based on valsartan and hydrochlorothiazide (47%), with no difference between the three arm groups in terms of tolerability. An ongoing randomized trial (Action in Diabetes and Vascular Disease: Preterax and Diamicron Modified Release Controlled Evaluation; ADVANCE) is a study with a 2 x 2 factorial design assessing the effects of the fixed-dose perindopril-indapamide combination and of the intensive gliclazide modified release-based glucose control regimen in type 2 diabetic patients, with or without hypertension. A total of 11 140 patients were randomly selected. Within the first 6 weeks of treatment (run-in phase), the perindopril-indapamide combination lowered blood pressure from 145/81 +/- 22/11 mmHg (mean +/- SD) to 137/78 +/- 20/10 mmHg. Fixed-dose combinations are becoming more and more popular for the management of hypertension, and are even proposed by hypertension guidelines as a first-line option to treat hypertensive patients.
Resumo:
Objective: Although 24-hour arterial blood pressure can be monitored in a free-moving animal using pressure telemetric transmitter mostly from Data Science International (DSI), accurate monitoring of 24-hour mouse left ventricular pressure (LVP) is not available because of its insufficient frequency response to a high frequency signal such as the maximum derivative of mouse LVP (LVdP/dtmax and LVdP/dtmin). The aim of the study was to develop a tiny implantable flow-through LVP telemetric transmitter for small rodent animals, which can be potentially adapted for human 24 hour BP and LVP accurate monitoring. Design and Method: The mouse LVP telemetric transmitter (Diameter: _12 mm, _0.4 g) was assembled by a pressure sensor, a passive RF telemetry chip, and to a 1.2F Polyurethane (PU) catheter tip. The device was developed in two configurations and compared with existing DSI system: (a) prototype-I: a new flow-through pressure sensor with wire link and (b) prototype-II: prototype-I plus a telemetry chip and its receiver. All the devices were applied in C57BL/6J mice. Data are mean_SEM. Results: A high frequency response (>100 Hz) PU heparin saline-filled catheter was inserted into mouse left ventricle via right carotid artery and implanted, LV systolic pressure (LVSP), LVdP/dtmax, and LVdP/dtmin were recorded on day2, 3, 4, 5, and 7 in conscious mice. The hemodynamic values were consistent and comparable (139_4 mmHg, 16634_319, - 12283_184 mmHg/s, n¼5) to one recorded by a validated Pebax03 catheter (138_2mmHg, 16045_443 and -12112_357 mmHg/s, n¼9). Similar LV hemodynamic values were obtained with Prototype-I. The same LVP waveforms were synchronically recorded by Notocord wire and Senimed wireless software through prototype-II in anesthetized mice. Conclusion: An implantable flow-through LVP transmitter (prototype-I) is generated for LVP accurate assessment in conscious mice. The prototype-II needs a further improvement on data transmission bandwidth and signal coupling distance to its receiver for accurate monitoring of LVP in a freemoving mouse.
Resumo:
BACKGROUND: Acute exposure to high altitude stimulates free radical formation in lowlanders, yet whether this persists during chronic exposure in healthy, well-adapted and maladapted highlanders suffering from chronic mountain sickness (CMS) remains to be established. METHODS: Oxidative-nitrosative stress (as determined by the presence of the biomarkers ascorbate radical [A •- ], via electron paramagnetic resonance spectroscopy, and nitrite [NO 2 2 ], via ozone-based chemiluminescence) was assessed in venous blood of 25 male highlanders in Bolivia living at 3,600 m with CMS (n 5 13, CMS 1 ) and without CMS (n 5 12, CMS 2 ). Twelve age- and activity-matched, healthy, male lowlanders were examined at sea level and during acute hypoxia. We also measured fl ow-mediated dilatation (FMD), arterial stiffness defined by augmentation index normalized for a heart rate of 75 beats/min (AIx-75), and carotid intima-media thickness (IMT). RESULTS: Compared with normoxic lowlanders, oxidative-nitrosative stress was moderately increased in the CMS 2 group ( P , .05), as indicated by elevated A •- (3,191 457 arbitrary units [AU] vs 2,640 445 AU) and lower NO 2 2 (206 55 nM vs 420 128 nM), whereas vascular function remained preserved. This was comparable to that observed during acute hypoxia in lowlanders in whom vascular dysfunction is typically observed. In contrast, this response was markedly exaggerated in CMS 1 group (A •- , 3,765 429 AU; NO 2 2 , 148 50 nM) compared with both the CMS 2 group and lowlanders ( P , .05). This was associated with systemic vascular dysfunction as indicated by lower ( P , .05 vs CMS 2 ) FMD (4.2% 0.7% vs 7.6% 1.7%) and increased AIx-75 (23% 8% vs 12% 7%) and carotid IMT (714 127 m M vs 588 94 m M). CONCLUSIONS: Healthy highlanders display a moderate, sustained elevation in oxidative-nitrosative stress that, unlike the equivalent increase evoked by acute hypoxia in healthy lowlanders, failed to affect vascular function. Its more marked elevation in patients with CMS may contribute to systemic vascular dysfunction.
Resumo:
Aim: We asked whether myocardial flow reserve (MFR) by Rb-82 cardiac PET improve the selection of patients eligible for invasive coronary angiography (ICA). Material and Methods: We enrolled 26 consecutive patients with suspected or known coronary artery disease who performed dynamic Rb-82 PET/CT and (ICA) within 60 days; 4 patients who underwent revascularization or had any cardiovascular events between PET and ICA were excluded. Myocardial blood flow at rest (rMBF), at stress with adenosine (sMBF) and myocardial flow reserve (MFR=sMBF/rMBF) were estimated using the 1-compartment Lortie model (FlowQuant) for each coronary arteries territories. Stenosis severity was assessed using computer-based automated edge detection (QCA). MFR was divided in 3 groups: G1:MFR<1.5, G2:1.5≤MFR<2 and G3:2≤MFR. Stenosis severity was graded as non-significant (<50% or FFR ≥0.8), intermediate (50%≤stenosis<70%) and severe (≥70%). Correlation between MFR and percentage of stenosis were assessed using a non-parametric Spearman test. Results: In G1 (44 vessels), 17 vessels (39%) had a severe stenosis, 11 (25%) an intermediate one, and 16 (36%) no significant stenosis. In G2 (13 vessels), 2 (15%) vessels presented a severe stenosis, 7 (54%) an intermediate one, and 4 (31%) no significant stenosis. In G3 (9 vessels), 0 vessel presented a severe stenosis, 1 (11%) an intermediate one, and 8 (89%) no significant stenosis. Of note, among 11 patients with 3-vessel low MFR<1.5 (G1), 9/11 (82%) had at least one severe stenosis and 2/11 (18%) had at least one intermediate stenosis. There was a significant inverse correlation between stenosis severity and MFR among all 66 territories analyzed (rho= -0.38, p=0.002). Conclusion: Patients with MFR>2 could avoid ICA. Low MFR (G1, G2) on a vessel-based analysis seems to be a poor predictor of severe stenosis severity. Patients with 3-vessel low MFR would benefit from ICA as they are likely to present a significant stenosis in at least one vessel.