976 resultados para Virtual Manufacturing
Resumo:
The work presented is concerned with the estimation of manufacturing cost at the concept design stage, when little technical information is readily available. The work focuses on the nose cowl sections of a wide range of engine nacelles built at Bombardier Aerospace Shorts of Belfast. A core methodology is presented that: defines manufacturing cost elements that are prominent; utilises technical parameters that are highly influential in generating those costs; establishes the linkage between these two; and builds the associated cost estimating relations into models. The methodology is readily adapted to deal with both the early and more mature conceptual design phases, which thereby highlights the generic, flexible and fundamental nature of the method. The early concept cost model simplifies cost as a cumulative element that can be estimated using higher level complexity ratings, while the mature concept cost model breaks manufacturing cost down into a number of constituents that are each driven by their own specific drivers. Both methodologies have an average error of less that ten percent when correlated with actual findings, thus achieving an acceptable level of accuracy. By way of validity and application, the research is firmly based on industrial case studies and practice and addresses the integration of design and manufacture through cost. The main contribution of the paper is the cost modelling methodology. The elemental modelling of the cost breakdown structure through materials, part fabrication, assembly and their associated drivers is relevant to the analytical design procedure, as it utilises design definition and complexity that is understood by engineers.
Resumo:
The scattering of electrons with kinetic energies down to a few meV by para-xylene and para-difluorobenzene has been observed experimentally with an electron beam energy resolution of 0.95 to 1.5 meV (full width half maximum). At low electron energies the collisions can be considered as cold scattering events because the de Broglie wavelength of the electron is considerably larger than the target dimensions. The scattering cross sections measured rise rapidly at low energy due to virtual state scattering. The nature of this scattering process is discussed using s- and p-wave phase shifts derived from the experimental data. Scattering lengths are derived of, respectively, -9.5+/-0.5 and -8.0+/-0.5 a.u. for para-xylene and para-difluorobenzene. The virtual state effect is interpreted in terms of nuclear diabatic and partially adiabatic models, involving the electronic and vibronic symmetries of the unoccupied orbitals in the target species. The concept of direct and indirect virtual state scattering is introduced, through which the present species, in common with carbon dioxide and benzene, scatter through an indirect virtual state process, whereas other species, such as perfluorobenzene, scatter through a direct process. (C) 2005 American Institute of Physics.
Resumo:
Background and purpose: Radiotherapy is widely used to palliate local symptoms in non-small-cell lung cancer. Using conventional X-ray simulation, it is often difficult to accurately localize the extent of the tumour. We report a randomized, double blind trial comparing target localization with conventional and virtual simulation.Methods: Eighty-six patients underwent both conventional and virtual simulation. The conventional simulator films were compared with digitally reconstructed radiographs (DRRs) produced from the computed tomography (CT) data. The treatment fields defined by the clinicians using each modality were compared in terms of field area, position and the implications for target coverage.Results: Comparing fields defined by each study arm, there was a major mis-match in coverage between fields in 66.2% of cases, and a complete match in only 5.2% of cases. In 82.4% of cases, conventional simulator fields were larger (mean 24.5+/-5.1% (95% confidence interval)) than CT-localized fields, potentially contributing to a mean target under-coverage of 16.4+/-3.5% and normal tissue over-coverage of 25.4+/-4.2%.Conclusions: CT localization and virtual simulation allow more accurate definition of the target volume. This could enable a reduction in geographical misses, while also reducing treatment-related toxicity.