975 resultados para Ventilation artificielle
Resumo:
Zygomycosis is an infection caused by opportunistic fungi of the Zygomycetes class, specifically those from the Mucorales and Entomophthorales orders. It is an uncommon disease, mainly restricted to immunocompromised patients. We report a case of a 73-year-old male patient with a history of fever (39°C) lasting for 1 day, accompanied by shivering, trembling, and intense asthenia. The patient was admitted to the intensive care unit with complex partial seizures, and submitted to orotracheal intubation and mechanical ventilation under sedation with midazolam. The electroencephalogram showed evidence of non-convulsive status epilepticus. There is no fast specific laboratory test that permits confirmation of invasive fungal disease. Unless the physician suspects this condition, the disease may progress rapidly while the patient is treated with broad-spectrum antibiotics. Differential diagnosis between fungal and bacterial infection is often difficult. The clinical presentation is sometimes atypical, and etiological investigation is not always successful. In the present case, the histopathological examination of the biopsy obtained from the right temporal lobe indicated the presence of irregular, round, thick-walled fungi forming papillae and elongated structures of irregular diameter, with no septa, indicative of zygomycete (Basidiobolus). Treatment with liposomal amphotericin B and fluconazole was initiated after diagnosis of meningoencephalitis by zygomycete, with a successful outcome.
Resumo:
Subclinical hypothyroidism (SH) patients present cardiopulmonary, vascular and muscle dysfunction, but there is no consensus about the benefits of levothyroxine (L-T4) intervention on cardiopulmonary performance during exercise. The aim of the present study was to investigate the effects of L-T4 on cardiopulmonary exercise reserve and recovery in SH patients. Twenty-three SH women, 44 (40-50) years old, were submitted to two ergospirometry tests, with an interval of 6 months of normalization of thyroid-stimulating hormone (TSH) levels (L-T4 replacement group) or simple observation (TSH = 6.90 μIU/mL; L-T4 = 1.02 ng/dL). Patients with TSH >10 μIU/mL were excluded from the study to assure that they would receive treatment in this later stage of SH. Twenty 30- to 57-year-old women with no thyroid dysfunction (TSH = 1.38 μIU/mL; L-T4 = 1.18 ng/dL) were also evaluated. At baseline, lower values of gas exchange ratio reserve (0.24 vs 0.30; P < 0.05) were found for SH patients. The treated group presented greater variation than the untreated group for pulmonary ventilation reserve (20.45 to 21.60 L/min; median variation = 5.2 vs 25.09 to 22.45 L/min; median variation = -4.75, respectively) and for gas exchange ratio reserve (0.19 to 0.27; median variation = 0.06 vs 0.28 to 0.18; median variation = -0.08, respectively). There were no relevant differences in cardiopulmonary recovery for either group at baseline or after follow-up. In the sample studied, L-T4 replacement improved exercise cardiopulmonary reserve, but no modification was found in recovery performance after exercise during this period of analysis.
Resumo:
The application of continuous positive airway pressure (CPAP) produces important hemodynamic alterations, which can influence breathing pattern (BP) and heart rate variability (HRV). The aim of this study was to evaluate the effects of different levels of CPAP on postoperative BP and HRV after coronary artery bypass grafting (CABG) surgery and the impact of CABG surgery on these variables. Eighteen patients undergoing CABG were evaluated postoperatively during spontaneous breathing (SB) and application of four levels of CPAP applied in random order: sham (3 cmH2O), 5 cmH2O, 8 cmH2O, and 12 cmH2O. HRV was analyzed in time and frequency domains and by nonlinear methods and BP was analyzed in different variables (breathing frequency, inspiratory tidal volume, inspiratory and expiratory time, total breath time, fractional inspiratory time, percent rib cage inspiratory contribution to tidal volume, phase relation during inspiration, phase relation during expiration). There was significant postoperative impairment in HRV and BP after CABG surgery compared to the preoperative period and improvement of DFAα1, DFAα2 and SD2 indexes, and ventilatory variables during postoperative CPAP application, with a greater effect when 8 and 12 cmH2O were applied. A positive correlation (P < 0.05 and r = 0.64; Spearman) was found between DFAα1 and inspiratory time to the delta of 12 cmH2O and SB of HRV and respiratory values. Acute application of CPAP was able to alter cardiac autonomic nervous system control and BP of patients undergoing CABG surgery and 8 and 12 cmH2O of CPAP provided the best performance of pulmonary and cardiac autonomic functions.
Resumo:
We determined the response characteristics and functional correlates of the dynamic relationship between the rate (Δ) of oxygen consumption ( O2) and the applied power output (work rate = WR) during ramp-incremental exercise in patients with mitochondrial myopathy (MM). Fourteen patients (7 males, age 35.4 ± 10.8 years) with biopsy-proven MM and 10 sedentary controls (6 males, age 29.0 ± 7.8 years) took a ramp-incremental cycle ergometer test for the determination of the
O2 on-exercise mean response time (MRT) and the gas exchange threshold (GET). The Δ
O2/ΔWR slope was calculated up to GET (S1), above GET (S2) and over the entire linear portion of the response (S T). Knee muscle endurance was measured by isokinetic dynamometry. As expected, peak
O2 and muscle performance were lower in patients than controls (P < 0.05). Patients had significantly lower Δ
O2/ΔWR than controls, especially the S2 component (6.8 ± 1.5 vs 10.3 ± 0.6 mL·min-1·W-1, respectively; P < 0.001). There were significant relationships between Δ
O2/ΔWR (S T) and muscle endurance, MRT-
O2, GET and peak
O2 in MM patients (P < 0.05). In fact, all patients with Δ
O2/ΔWR below 8 mL·min-1·W-1 had severely reduced peak
O2 values (<60% predicted). Moreover, patients with higher cardiopulmonary stresses during exercise (e.g., higher Δ ventilation/carbon dioxide output and Δ heart rate/Δ
O2) had lower Δ
O2/ΔWR (P < 0.05). In conclusion, a readily available, effort-independent index of aerobic dysfunction during dynamic exercise (Δ
O2/ΔWR) is typically reduced in patients with MM, being related to increased functional impairment and higher cardiopulmonary stress.
Resumo:
The arterial partial pressure (P CO2) of carbon dioxide is virtually constant because of the close match between the metabolic production of this gas and its excretion via breathing. Blood gas homeostasis does not rely solely on changes in lung ventilation, but also to a considerable extent on circulatory adjustments that regulate the transport of CO2 from its sites of production to the lungs. The neural mechanisms that coordinate circulatory and ventilatory changes to achieve blood gas homeostasis are the subject of this review. Emphasis will be placed on the control of sympathetic outflow by central chemoreceptors. High levels of CO2 exert an excitatory effect on sympathetic outflow that is mediated by specialized chemoreceptors such as the neurons located in the retrotrapezoid region. In addition, high CO2 causes an aversive awareness in conscious animals, activating wake-promoting pathways such as the noradrenergic neurons. These neuronal groups, which may also be directly activated by brain acidification, have projections that contribute to the CO2-induced rise in breathing and sympathetic outflow. However, since the level of activity of the retrotrapezoid nucleus is regulated by converging inputs from wake-promoting systems, behavior-specific inputs from higher centers and by chemical drive, the main focus of the present manuscript is to review the contribution of central chemoreceptors to the control of autonomic and respiratory mechanisms.
Resumo:
Ventilator-associated pneumonia (VAP) remains one of the major causes of infection in the intensive care unit (ICU) and is associated with the length of hospital stay, duration of mechanical ventilation, and use of broad-spectrum antibiotics. We compared the frequency of VAP 10 months prior to (pre-intervention group) and 13 months after (post-intervention group) initiation of the use of a heat and moisture exchanger (HME) filter. This is a study with prospective before-and-after design performed in the ICU in a tertiary university hospital. Three hundred and fourteen patients were admitted to the ICU under mechanical ventilation, 168 of whom were included in group HH (heated humidifier) and 146 in group HME. The frequency of VAP per 1000 ventilator-days was similar for both the HH and HME groups (18.7 vs 17.4, respectively; P = 0.97). Duration of mechanical ventilation (11 vs 12 days, respectively; P = 0.48) and length of ICU stay (11 vs 12 days, respectively; P = 0.39) did not differ between the HH and HME groups. The chance of developing VAP was higher in patients with a longer ICU stay and longer duration of mechanical ventilation. This finding was similar when adjusted for the use of HME. The use of HME in intensive care did not reduce the incidence of VAP, the duration of mechanical ventilation, or the length of stay in the ICU in the study population.
Resumo:
The objective of this study was to determine the feasibility of the use of continuous positive airway pressure installed prophylactically in the delivery room (DR-CPAP), for infants with a birth weight between 500 and 1000 g in settings with limited resources. During 23 months, infants with a birth weight between 500 and 1000 g consecutively received DR-CPAP. A total of 33 infants with low birth weight were enrolled, 16 (48.5%) were females. Only 14 (42.4%) received antenatal corticosteroids and only 2 of those 14 (14.3%) infants weighing 500-750 g were not intubated in the delivery room, and apnea was given as the reason for intubation of these patients. Of the 19 infants in the 751-1000 g weight range, 9 (47.4%) were intubated in the delivery room, 6 due to apnea and 3 due to respiratory discomfort. For DR-CPAP to be successful, it is probably necessary for preterm babies to be more prepared at birth to withstand the respiratory effort without the need for intubation. Antenatal corticosteroids and better prenatal monitoring are fundamental for success of DR-CPAP.
Resumo:
This study evaluated whether the use of continuous positive airway pressure (CPAP) in the delivery room alters the need for mechanical ventilation and surfactant during the first 5 days of life and modifies the incidence of respiratory morbidity and mortality during the hospital stay. The study was a multicenter randomized clinical trial conducted in five public university hospitals in Brazil, from June 2008 to December 2009. Participants were 197 infants with birth weight of 1000-1500 g and without major birth defects. They were treated according to the guidelines of the American Academy of Pediatrics (APP). Infants not intubated or extubated less than 15 min after birth were randomized for two treatments, routine or CPAP, and were followed until hospital discharge. The routine (n=99) and CPAP (n=98) infants studied presented no statistically significant differences regarding birth characteristics, complications during the prenatal period, the need for mechanical ventilation during the first 5 days of life (19.2 vs 23.4%, P=0.50), use of surfactant (18.2 vs 17.3% P=0.92), or respiratory morbidity and mortality until discharge. The CPAP group required a greater number of doses of surfactant (1.5 vs 1.0, P=0.02). When CPAP was applied to the routine group, it was installed within a median time of 30 min. We found that CPAP applied less than 15 min after birth was not able to reduce the need for ventilator support and was associated with a higher number of doses of surfactant when compared to CPAP applied as clinically indicated within a median time of 30 min.
IL-6 and TNF-α serum levels are associated with early death in community-acquired pneumonia patients
Resumo:
Community-acquired pneumonia (CAP) is amongst the leading causes of death worldwide. As inflammatory markers, cytokines can predict outcomes, if interpreted together with clinical data and scoring systems such as CURB-65, CRB, and Acute Physiology and Chronic Health Evaluation II (APACHE II). The aim of this study was to determine the impact of inflammatory biomarkers on the early mortality of hospitalized CAP patients. Twenty-seven CAP patients needing hospitalization were enrolled for the study and samples of interleukin-1 (IL-1) and interleukin-6 (IL-6), tumor necrosis factor alpha (TNF-α), C-reactive protein (CRP), and homocystein were collected at the time of admission (day 1) as well as on the seventh day of the treatment. There was a significant reduction in the levels of IL-6 between the first and the second collections. Median IL-6 values decreased from 24 pg/mL (day 1) to 8 pg/mL (day 7) (P=0.016). The median levels of TNF-α were higher in patients: i) with acute kidney injury (AKI) (P=0.045), ii) requiring mechanical ventilation (P=0.040), iii) with short hospital stays (P=0.009), iv) admitted to the intensive care unit (ICU) (P=0.040), v) who died early (P=0.003), and vi) with worse CRB scores (P=0.013). In summary, IL-6 and TNF-α levels were associated with early mortality of CAP patients. Longer admission levels demonstrated greater likelihood of early death and overall mortality, necessity of mechanical ventilation, and AKI.
Resumo:
The oxygen uptake efficiency slope (OUES) is a submaximal index incorporating cardiovascular, peripheral, and pulmonary factors that determine the ventilatory response to exercise. The purpose of this study was to evaluate the effects of continuous exercise training and interval exercise training on the OUES in patients with coronary artery disease. Thirty-five patients (59.3±1.8 years old; 28 men, 7 women) with coronary artery disease were randomly divided into two groups: continuous exercise training (n=18) and interval exercise training (n=17). All patients performed graded exercise tests with respiratory gas analysis before and 3 months after the exercise-training program to determine ventilatory anaerobic threshold (VAT), respiratory compensation point, and peak oxygen consumption (peak VO2). The OUES was assessed based on data from the second minute of exercise until exhaustion by calculating the slope of the linear relation between oxygen uptake and the logarithm of total ventilation. After the interventions, both groups showed increased aerobic fitness (P<0.05). In addition, both the continuous exercise and interval exercise training groups demonstrated an increase in OUES (P<0.05). Significant associations were observed in both groups: 1) continuous exercise training (OUES and peak VO2 r=0.57; OUES and VO2 VAT r=0.57); 2) interval exercise training (OUES and peak VO2 r=0.80; OUES and VO2 VAT r=0.67). Continuous and interval exercise training resulted in a similar increase in OUES among patients with coronary artery disease. These findings suggest that improvements in OUES among CAD patients after aerobic exercise training may be dependent on peripheral and central mechanisms.
Resumo:
Retrograde autologous priming (RAP) has been routinely applied in cardiac pediatric cardiopulmonary bypass (CPB). However, this technique is performed in pediatric patients weighing more than 20 kg, and research about its application in pediatric patients weighing less than 20 kg is still scarce. This study explored the clinical application of RAP in CPB in pediatric patients undergoing cardiac surgery. Sixty pediatric patients scheduled for cardiac surgery were randomly divided into control and experimental groups. The experimental group was treated with CPB using RAP, while the control group was treated with conventional CPB (priming with suspended red blood cells, plasma and albumin). The hematocrit (Hct) and lactate (Lac) levels at different perioperative time-points, mechanical ventilation time, hospitalization duration, and intraoperative and postoperative blood usage were recorded. Results showed that Hct levels at 15 min after CPB beginning (T2) and at CPB end (T3), and number of intraoperative blood transfusions were significantly lower in the experimental group (P<0.05). There were no significant differences in CPB time, aortic blocking time, T2-Lac value or T3-Lac between the two groups (P>0.05). Postoperatively, there were no significant differences in Hct (2 h after surgery), mechanical ventilation time, intensive care unit time, or postoperative blood transfusion between two groups (P>0.05). RAP can effectively reduce the hemodilution when using less or not using any banked blood, while meeting the intraoperative perfusion conditions, and decreasing the perioperative blood transfusion volume in pediatric patients.
Resumo:
Diplomityön tavoitteena on löytää UPM Kymin paperikone 8:n ensimmäisen kuivatusryhmän johtoteloihin kulumis- ja korroosiokestävämpi materiaali ja pinnoite vallitsevaan olosuhteeseen. Teloihin muodostuu pistemäistä korroosiota ja korroosioalue on paikallinen. Korroosiota syntyy kuivatusviiran alueella, jossa ei ole paperirainaa. Työssä suoritetaan kuivatusosan olosuhdemittauksia ja tutkitaan niiden vaikutuksia korroosion muodostumiseen. Suoritettavat olosuhdemittaukset ovat huuvan ilmatase, paineen 0-taso sekä lämpötilat ja kosteudet eri huuvan osissa. Savukaasumittauksen avulla tutkitaan huuvan ilmankiertoa ensimmäisen kuivatusryhmän viiranjohtotelojen läheisyydessä. Kuivatusviiran ilmanläpäisymittauksen avulla saadaan tietoa viiran ilmanläpäisykyvystä. Hypoteesina viiran tukkeutuminen johtuu pölyävästä kuivaus-prosessista ja kosteudesta. SEM/EDS-alkuainemittauksen avulla pystytään analysoimaan korrosiivisia alkuaineita niin korroosioalueella kuin ympäristössä. Työn tutkimuksen perusteella korroosion muodostuminen aiheutuu tukkeutuneen viiran muodostamasta happipitoisuuseroalueesta. Viiran saostumat sisältävät korrosiivisia kemikaaleja, kuten kloridia, rikkiä ja mangaania. Nämä kiihdyttävät korroosiota happipuutosalueella. Huuvan olosuhdemittauksien perusteella huuvan paineen 0-taso on vino. Savukaasu- ja kosteusmittauksien avulla huomattiin kostean ilman jäävän telojen läheisyyteen. Työssä kehitettiin paineilmapuhdistin viiran reuna-alueen puhdistamiseen. Kaavattaviin telapositioihin valittiin kobolttikromiseostettu volframikarbidipinnoite PTFE -fluoripolymeeritiivistyksellä. Muihin telapositioihin valittiin ETFE –fluori-polymeeripinnoite korroosion ehkäisemiseksi. Pinnoitteiden ja paineilmapuhdistimen avulla telojen käyttöaika nousee nykyisestä kahdesta vuodesta tavoiteltuun 10 vuoteen.
Resumo:
Diplomityön tavoitteena oli selvittää, kuinka sähkösuodattimella voidaan vaikuttaa sisäilman laatuun ja kuinka kilpailukykyinen vaihtoehto pienkiinteistöissä sähkösuodatin on perinteisiin kuitusuodattimiin verrattuna. Teoriaosassa tarkasteltiin, kuinka ilman hengitettävät hiukkaset muodostuvat ja miten ne vaikuttavat sisäilman laatuun sekä ihmisten terveyteen. Tarkasteltiin hiukkasten koon, lukumäärän, massan ja pinta-alan yhteyksiä niiden terveysvaikutuksiin. Ultrapienet hiukkaset ovat terveydelle haitallisimpia, koska hiukkasten lukumäärä ja pinta-ala lisäävät terveyshaittoja enemmän kuin hiukkasten massa. Tutkittiin pienkiinteistöjen ilmanvaihtoratkaisuja ja erilaisia tuloilmanpuhdistus-menetelmiä. Soveltavassa osassa tarkasteltiin sähkösuodattimen toimintaa ja sen mahdollisuuksia sisäilman parantajana verrattuna perinteisiin kuitusuodattimiin. Tehtiin sähkösuodattimen ja kuitusuodattimen välinen elinkaarikustannusvertailu keskisuurelle omakotitalolle. Kirjallisuuden ja tutkimushavaintojen perusteella sähkösuodattimen suurin etu muihin suodattimiin verrattuna on sen kyky poistaa kaiken kokoisia, myös ultrapieniä, hengitettäviä hiukkasia ja siten tehokkaasti vähentää hengitettävien hiukkasten lukumäärää ja pinta-alaa. Tällä voi olla vaikutusta yleisten terveyshaittojen ja ympäristöherkkyyden ennaltaehkäisemisessä. Ympäristöherkkyyteen sairastuneiden oireiluun sähkösuodatin voi tuottaa helpotusta kotioloissa ja siirrettävän ilmanpuhdistimen avulla myös työpaikoilla. Elinkaarikustannusvertailun perusteella selvisi, että sähkösuodatin on kalliimmasta hinnastaan huolimatta kokonaiskustannuksiltaan selvästi edullisempi vaihtoehto kuin kuitusuodattimet. Sähkösuodattimen haasteena on uuden teknologian lanseeraaminen pientalorakentamiseen. Pienrakennusten tuloilman puhdistusmenetelmien kehittämisellä olisi mahdollista parantaa suomalaisten elämänlaatua ja saavuttaa merkittäviä säästöjä terveydenhoitokuluissa.
Resumo:
The interesting ventilation system on the roof of the Science Complex.
Resumo:
Four groups of rainbow trout, Salmo gairdneri, were acclimated to 2°, 10°, and 18°e, and to a diurnal temperature cycle (100 ± 4°C). To evaluate the influence of cycling temperatures in terms of an immediate as opposed to acclimatory response various ventilatory-cardiovascular rate functions were observed for trout, either acclimated to cycling temperatures or acclimated to constant temperatures and exposed to a diurnal temperature cycle for the first time (10° ± 4°C for trout acclimated to 10°C; 18°+ 4°C for trout acclimated to l8°e). Gill resistance and the cardiac to ventilatory rate ratio were then calculated. Following a post preparatory recovery period of 36 hr, measurements were made over a 48 hour period with the first 24 hours being at constant temperature in the case of statically-acclimated fish followed by 24 hours under cyclic temperature conditions. Trout exhibited marked changes in oxygen consumption (Vo ) with temp- 2 erature both between acclimation groups, and in response to the diurnal temperature cycle. This increase in oxygen uptake appears to have been achieved by adjustment of ventilatory and, to some extent, cardiovascular activity. Trout exhibited significant changes in ventilatory rate (VR), stroke volume (Vsv), and flow (VG) in response to temperature. Marked changes in cardiac rate were also observed. These findings are discussed in relation to their importance in convective oxygen transport via water and blood at the gills and tissues. Trout also exhibited marked changes in pressure waveforms associated with the action of the resp; ratory pumps with temperature. Mean differenti a 1 pressure increased with temperature as did gill resistance and utilization. This data is discussed in relation to its importance in diffusive oxygen transport and the conditions for gas exchange at the gills. With one exception, rainbow trout were able to respond to changes in oxygen demand and availability associated with changes in temperature by means of adjustments in ventilation, and possibly pafusion, and the conditions for gas exchange at the gills. Trout acclimated to 18°C, however, and exposed to high cyclic temperatures, showed signs of the ventilatory and cardiovascular distress problems commonly associated with low circulating levels of oxygen in the blood. It appears these trout were unable to fully meet the oxygen requirements associated with c~ling temperatures above 18°C. These findings were discussed in relation to possible limitations in the cardiovascular-ventilatory response at high temperatures. The response of trout acclimated to cycling temperatures was generally similar to that for trout acclimated to constant temperatures and exposed to cycling temperatures for the first time. This result suggested that both groups of fish may have been acclimated to a similar thermal range, regardless of the acclimation regime employed. Such a phenomenon would allow trout of either acclimation group to respond equally well to the imposed temperature cycle. Rainbow trout showed no evidence of significant diurnal rhythm in any parameters observed at constant temperatures (2°, 10°, and 18° C), and under a 12/12 light-dark photoperiod regime. This was not taken to indicate an absence of circadian rhythms in these trout, but rather a deficiency in the recording methods used in the study.