997 resultados para Venous wall


Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: We report the results and complications associated with standardized intraoperative management designed for the prevention of hemodynamically relevant venous air embolism during surgery performed in the semisitting position. METHODS: A protocol for preoperative evaluation and intraoperative monitoring was developed and applied in 187 consecutive patients who underwent surgery in the semisitting position between 1999 and 2004. The protocol included preoperative transesophageal echocardiography examination (TEE), intraoperative TEE monitoring, catheterization of the right atrium and a combination of fluid input, positive end expiratory pressure, and standardized positioning aiming at a positive pressure in the transverse and sigmoid sinuses. Data were collected retrospectively from the charts and intraoperative anesthesiological protocols of the patients for the incidence of clinically relevant air embolism (i.e., TEE-diagnosed air embolism plus a decrease in end tidal CO2 or hemodynamic changes) and other complications related to the semisitting position. RESULTS: Three cases (1.6%) of relevant venous air embolism occurred in 187 patients. Only 1 case (0.5%) was hemodynamically relevant, with temporary arterial blood pressure decrease and heart rate increase. Pneumatocephalus leading to lethargy was a frequent postoperative finding, which resolved spontaneously in all except 1 patient with epileptic seizure and oculomotor nerve palsy attributable to space-occupying subdurally trapped air, which had to be treated surgically. There was no permanent morbidity or mortality related to the semisitting position. CONCLUSION: Fear of massive venous air embolism is one reason for dramatic decline in the use of the semisitting position in neurosurgical practice. We found that strict adherence to a standardized protocol using TEE monitoring before and during surgery; exclusion of patients with patent foramen ovale; and a combination of positive end expiratory pressure, fluid input, and a standardized position aiming a positive pressure in the transverse and sigmoid sinuses helped to greatly minimize this complication to a rate of 0.5% for hemodynamically relevant events.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Endothelial progenitor cells (EPC) are involved in many healing processes in cardiovascular diseases and can be found in spontaneously resolving venous thrombi. The purpose of the present study was to investigate whether the therapeutic administration of EPC might enhance the resolution of venous thrombi. For this purpose, venous thrombosis was induced in the infrarenal inferior vena cava (IVC) in 28 athymic nude rats. Culture expanded EPC derived from human peripheral blood mononuclear cells were injected intravenously two and four days after thrombus induction. Recanalisation of the IVC and thrombus organisation were assessed by laser Doppler measurements of the blood flow and immunohistochemical detection of endothelialised luminal structures in the thrombus. EPC transplantation resulted in significantly enhanced thrombus neovascularisation (capillary density: 186.6 +/- 26.7/HPF vs. 78 +/- 12.3/HPF, p<0.01; area covered by capillaries: 8.9 +/- 1.7 microm(2) vs. 2.5 +/- 1.3 microm(2), p<0.01) and was accompanied by a substantial increase in intra-thrombus blood flow (perfusion ratio: 0.7 +/- 0.07 vs. 0.3 +/- 0.08, p<0.02). These results were paralleled by augmented macrophage recruitment into resolving thrombi in the animals treated with EPC (39.4 +/- 4.7/HPF vs. 11.6 +/- 1.9/HPF, p<0.01). Our data suggest that EPC transplantation might be of clinical value to facilitate venous thrombus resolution in cases where current therapeutic options have limited success.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: In search of an optimal compression therapy for venous leg ulcers, a systematic review and meta-analysis was performed of randomized controlled trials (RCT) comparing compression systems based on stockings (MCS) with divers bandages. METHODS: RCT were retrieved from six sources and reviewed independently. The primary endpoint, completion of healing within a defined time frame, and the secondary endpoints, time to healing, and pain were entered into a meta-analysis using the tools of the Cochrane Collaboration. Additional subjective endpoints were summarized. RESULTS: Eight RCT (published 1985-2008) fulfilled the predefined criteria. Data presentation was adequate and showed moderate heterogeneity. The studies included 692 patients (21-178/study, mean age 61 years, 56% women). Analyzed were 688 ulcerated legs, present for 1 week to 9 years, sizing 1 to 210 cm(2). The observation period ranged from 12 to 78 weeks. Patient and ulcer characteristics were evenly distributed in three studies, favored the stocking groups in four, and the bandage group in one. Data on the pressure exerted by stockings and bandages were reported in seven and two studies, amounting to 31-56 and 27-49 mm Hg, respectively. The proportion of ulcers healed was greater with stockings than with bandages (62.7% vs 46.6%; P < .00001). The average time to healing (seven studies, 535 patients) was 3 weeks shorter with stockings (P = .0002). In no study performed bandages better than MCS. Pain was assessed in three studies (219 patients) revealing an important advantage of stockings (P < .0001). Other subjective parameters and issues of nursing revealed an advantage of MCS as well. CONCLUSIONS: Leg compression with stockings is clearly better than compression with bandages, has a positive impact on pain, and is easier to use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To evaluate a widely used nontunneled triple-lumen central venous catheter in order to determine whether the largest of the three lumina (16 gauge) can tolerate high flow rates, such as those required for computed tomographic angiography. MATERIALS AND METHODS: Forty-two catheters were tested in vitro, including 10 new and 32 used catheters (median indwelling time, 5 days). Injection pressures were continuously monitored at the site of the 16-gauge central venous catheter hub. Catheters were injected with 300 and 370 mg of iodine per milliliter of iopamidol by using a mechanical injector at increasing flow rates until the catheter failed. The infusion rate, hub pressure, and location were documented for each failure event. The catheter pressures generated during hand injection by five operators were also analyzed. Mean flow rates and pressures at failure were compared by means of two-tailed Student t test, with differences considered significant at P < .05. RESULTS: Injections of iopamidol with 370 mg of iodine per milliliter generate more pressure than injections of iopamidol with 300 mg of iodine per milliliter at the same injection rate. All catheters failed in the tubing external to the patient. The lowest flow rate at which catheter failure occurred was 9 mL/sec. The lowest hub pressure at failure was 262 pounds per square inch gauge (psig) for new and 213 psig for used catheters. Hand injection of iopamidol with 300 mg of iodine per milliliter generated peak hub pressures ranging from 35 to 72 psig, corresponding to flow rates ranging from 2.5 to 5.0 mL/sec. CONCLUSION: Indwelling use has an effect on catheter material property, but even for used catheters there is a substantial safety margin for power injection with the particular triple-lumen central venous catheter tested in this study, as the manufacturer's recommendation for maximum pressure is 15 psig.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Having to carry input devices can be inconvenient when interacting with wall-sized, high-resolution tiled displays. Such displays are typically driven by a cluster of computers. Running existing games on a cluster is non-trivial, and the performance attained using software solutions like Chromium is not good enough. This paper presents a touch-free, multi-user, humancomputer interface for wall-sized displays that enables completely device-free interaction. The interface is built using 16 cameras and a cluster of computers, and is integrated with the games Quake 3 Arena (Q3A) and Homeworld. The two games were parallelized using two different approaches in order to run on a 7x4 tile, 21 megapixel display wall with good performance. The touch-free interface enables interaction with a latency of 116 ms, where 81 ms are due to the camera hardware. The rendering performance of the games is compared to their sequential counterparts running on the display wall using Chromium. Parallel Q3A’s framerate is an order of magnitude higher compared to using Chromium. The parallel version of Homeworld performed on par with the sequential, which did not run at all using Chromium. Informal use of the touch-free interface indicates that it works better for controlling Q3A than Homeworld.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To determine the pulmonary venous flow velocity (PVFV) values in a large normal population. DESIGN Prospective study in consecutive individuals. SETTING University hospital. METHODS Among 404 normal individuals, the flow velocity pattern in the right upper pulmonary vein was recorded in 315 subjects using transthoracic echocardiography, and in both upper pulmonary veins in 100 subjects using transoesophageal echocardiography. Subjects were divided into five age groups. The PVFV values were compared between transthoracic and transoesophageal echocardiography within the age groups, and intraindividually between the right and left upper pulmonary veins in transoesophageal echocardiography. RESULTS Normal PVFV values for the right upper pulmonary vein in transthoracic and transoesophageal echocardiography are presented. The duration of flow reversal at atrial contraction was overestimated using transthoracic echocardiography (mean (SD): 96 (21) ms in transoesophageal echocardiography, 120 (28) ms in transthoracic echocardiography, p < 0.0001). Systolic to diastolic peak flow velocity ratio (S:D) increased earlier with advancing age with transoesophageal echocardiography than with transthoracic echocardiography. Similar results were found for the corresponding time-velocity integrals. Data from the left and right upper pulmonary veins differed with respect to onset and deceleration of flow velocities, but not for flow durations or peak velocities. CONCLUSIONS Normal PVFV values generally show a wide range. The data presented will be of value in assessing left ventricular diastolic function and mitral regurgitation using the PVFV pattern.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aims: To assess observations with multimodality imaging of the Absorb bioresorbable everolimus-eluting vascular scaffold performed in two consecutive cohorts of patients who were serially investigated either at 6 and 24 months or at 12 and 36 months. Methods and results: In the ABSORB multicentre single-arm trial, 45 patients (cohort B1) and 56 patients (cohort B2) underwent serial invasive imaging, specifically quantitative coronary angiography (QCA), intravascular ultrasound (IVUS), radiofrequency backscattering (IVUS-VH) and optical coherence tomography (OCT). Between one and three years, late luminal loss remained unchanged (6 months: 0.19 mm, 1 year: 0.27 mm, 2 years: 0.27 mm, 3 years: 0.29 mm) and the in-segment angiographic restenosis rate for the entire cohort B (n=101) at three years was 6%. On IVUS, mean lumen, scaffold, plaque and vessel area showed enlargement up to two years. Mean lumen and scaffold area remained stable between two and three years whereas significant reduction in plaque behind the struts occurred with a trend toward adaptive restrictive remodelling of EEM. Hyperechogenicity of the vessel wall, a surrogate of the bioresorption process, decreased from 23.1% to 10.4% with a reduction of radiofrequency backscattering for dense calcium and necrotic core. At three years, the count of strut cores detected on OCT increased significantly, probably reflecting the dismantling of the scaffold; 98% of struts were covered. In the entire cohort B (n=101), the three-year major adverse cardiac event rate was 10.0% without any scaffold thrombosis. Conclusions: The current investigation demonstrated the dynamics of vessel wall changes after implantation of a bioresorbable scaffold, resulting at three years in stable luminal dimensions, a low restenosis rate and a low clinical major adverse cardiac events rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND A majority of patients undergoing ablation of ventricular tachycardia have implanted devices precluding substrate imaging with delayed-enhancement MRI. Contrast-enhanced multidetector computed tomography (MDCT) can depict myocardial wall thickness with submillimetric resolution. We evaluated the relationship between regional myocardial wall thinning (WT) imaged by MDCT and arrhythmogenic substrate in postinfarction ventricular tachycardia. METHODS AND RESULTS We studied 13 consecutive postinfarction patients undergoing MDCT before ablation. MDCT data were integrated with high-density 3-dimensional electroanatomic maps acquired during sinus rhythm (endocardium, 509±291 points/map; epicardium, 716±323 points/map). Low-voltage areas (<1.5 mV) and local abnormal ventricular activities (LAVA) during sinus rhythm were assessed with regard to the WT. A significant correlation was found between the areas of WT <5 mm and endocardial low voltage (correlation-R=0.82; P=0.001), but no such correlation was found in the epicardium. The WT <5 mm area was smaller than the endocardial low-voltage area (54 cm(2) [Q1-Q3, 46-92] versus 71 cm(2) [Q1-Q3, 59-124]; P=0.001). Among a total of 13 060 electrograms reviewed in the whole study population, 538 LAVA were detected and analyzed. LAVA were located within the WT <5 mm (469/538 [87%]) or at its border (100% within 23 mm). Very late LAVA (>100 ms after QRS complex) were almost exclusively detected within the thinnest area (93% in the WT<3 mm). CONCLUSIONS Regional myocardial WT correlates to low-voltage regions and distribution of LAVA critical for the generation and maintenance of postinfarction ventricular tachycardia. The integration of MDCT WT with 3-dimensional electroanatomic maps can help focus mapping and ablation on the culprit regions, even when MRI is precluded by the presence of implanted devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In the field of thrombosis and haemostasis, many preanalytical variables influence the results of coagulation assays and measures to limit potential results variations should be taken. To our knowledge, no paper describing the development and maintenance of a haemostasis biobank has been previously published. Our description of the biobank of the Swiss cohort of elderly patients with venous thromboembolism (SWITCO65+) is intended to facilitate the set-up of other biobanks in the field of thrombosis and haemostasis. SWITCO65+ is a multicentre cohort that prospectively enrolled consecutive patients aged ≥65 years with venous thromboembolism at nine Swiss hospitals from 09/2009 to 03/2012. Patients will be followed up until December 2013. The cohort includes a biobank with biological material from each participant taken at baseline and after 12 months of follow-up. Whole blood from all participants is assayed with a standard haematology panel, for which fresh samples are required. Two buffy coat vials, one PAXgene Blood RNA System tube and one EDTA-whole blood sample are also collected at baseline for RNA/DNA extraction. Blood samples are processed and vialed within 1 h of collection and transported in batches to a central laboratory where they are stored in ultra-low temperature archives. All analyses of the same type are performed in the same laboratory in batches. Using multiple core laboratories increased the speed of sample analyses and reduced storage time. After recruiting, processing and analyzing the blood of more than 1,000 patients, we determined that the adopted methods and technologies were fit-for-purpose and robust.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES Although the use of an adjudication committee (AC) for outcomes is recommended in randomized controlled trials, there are limited data on the process of adjudication. We therefore aimed to assess whether the reporting of the adjudication process in venous thromboembolism (VTE) trials meets existing quality standards and which characteristics of trials influence the use of an AC. STUDY DESIGN AND SETTING We systematically searched MEDLINE and the Cochrane Library from January 1, 2003, to June 1, 2012, for randomized controlled trials on VTE. We abstracted information about characteristics and quality of trials and reporting of adjudication processes. We used stepwise backward logistic regression model to identify trial characteristics independently associated with the use of an AC. RESULTS We included 161 trials. Of these, 68.9% (111 of 161) reported the use of an AC. Overall, 99.1% (110 of 111) of trials with an AC used independent or blinded ACs, 14.4% (16 of 111) reported how the adjudication decision was reached within the AC, and 4.5% (5 of 111) reported on whether the reliability of adjudication was assessed. In multivariate analyses, multicenter trials [odds ratio (OR), 8.6; 95% confidence interval (CI): 2.7, 27.8], use of a data safety-monitoring board (OR, 3.7; 95% CI: 1.2, 11.6), and VTE as the primary outcome (OR, 5.7; 95% CI: 1.7, 19.4) were associated with the use of an AC. Trials without random allocation concealment (OR, 0.3; 95% CI: 0.1, 0.8) and open-label trials (OR, 0.3; 95% CI: 0.1, 1.0) were less likely to report an AC. CONCLUSION Recommended processes of adjudication are underreported and lack standardization in VTE-related clinical trials. The use of an AC varies substantially by trial characteristics.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

When used in veterinary medicine, central venous catheters are typically inserted through the external jugular vein, with their caudal extension within the cranial vena cava. Radiographic or fluoroscopic guidance is recommended to assist in correctly placing these catheters. This article provides radiologic examples of common central venous catheter malpositions and complications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The relationship between platelet count and outcome in patients with acute venous thromboembolism (VTE) has not been consistently explored. RIETE is an ongoing registry of consecutive patients with acute VTE. We categorised patients as having very low- (<80,000/µl), low- (80,000/µl to 150,000/µl), normal- (150,000/µl to 300,000/µl), high- (300,000/µl to 450,000/µl), or very high (>450,000/µl) platelet count at baseline, and compared their three-month outcome. As of October 2012, 43,078 patients had been enrolled in RIETE: 21,319 presenting with pulmonary embolism and 21,759 with deep-vein thrombosis. In all, 502 patients (1.2%) had very low-; 5,472 (13%) low-; 28,386 (66%) normal-; 7,157 (17%) high-; and 1,561 (3.6%) very high platelet count. During the three-month study period, the recurrence rate was: 2.8%, 2.2%, 1.8%, 2.1% and 2.2%, respectively; the rate of major bleeding: 5.8%, 2.6%, 1.7%, 2.3% and 4.6%, respectively; the rate of fatal bleeding: 2.0%, 0.9%, 0.3%, 0.5% and 1.2%, respectively; and the mortality rate: 29%, 11%, 6.5%, 8.8% and 14%, respectively. On multivariate analysis, patients with very low-, low-, high- or very high platelet count had an increased risk for major bleeding (odds ratio [OR]: 2.70, 95% confidence interval [CI]: 1.85-3.95; 1.43 [1.18-1.72]; 1.23 [1.03-1.47]; and 2.13 [1.65-2.75]) and fatal bleeding (OR: 3.70 [1.92-7.16], 2.10 [1.48-2.97], 1.29 [0.88-1.90] and 2.49 [1.49-4.15]) compared with those with normal count. In conclusion, we found a U-shaped relationship between platelet count and the three-month rate of major bleeding and fatal bleeding in patients with VTE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIM: Sclerotherapy is the targeted chemical ablation of varicose veins by intravenous injection of a liquid or foamed sclerosing drug. The treated veins may be intradermal, subcutaneous, and/or transfascial as well as superficial and deep in venous malformations. The aim of this guideline is to give evidence-based recommendations for liquid and foam sclerotherapy. METHODS: This guideline was drafted on behalf of 23 European Phlebological Societies during a Guideline Conference on 7-10 May 2012 in Mainz. The conference was organized by the German Society of Phlebology. These guidelines review the present state of knowledge as reflected in published medical literature. The regulatory situation of sclerosant drugs differs from country to country but this has not been considered in this document. The recommendations of this guideline are graded according to the American College of Chest Physicians Task Force recommendations on Grading Strength of Recommendations and Quality of Evidence in Clinical Guidelines. RESULTS: This guideline focuses on the two sclerosing drugs which are licensed in the majority of the European countries, polidocanol and sodium tetradecyl sulphate. Other sclerosants are not discussed in detail. The guideline gives recommendations concerning indications, contraindications, side-effects, concentrations, volumes, technique and efficacy of liquid and foam sclerotherapy of varicose veins and venous malformations.