991 resultados para Two parameter
Resumo:
During the last years there has been an increasing concern about occupational exposure to cytostatic drugs in hospitals. The first findings on occupational exposures among hospital personnel administering chemotherapy were reported only in 1979. Since then, a great number of studies have been publishing describing possible exposure-related health effects. Consequently, rigorous guidelines for the safe handling of cancer chemotherapeutic agents were devised and the handling facilities in hospitals were extensively improved. However, recent studies developed in European countries revealed detectable amounts of several drugs in surface wipe samples. Dermal absorption after contact with contaminated surfaces can play an important role in exposure to antineoplastic drugs. Therefore, the existence of contamination in workplace surfaces implies an increased risk of exposure for health care workers. Since there is no recent report in Portugal, regarding the occupational exposure to antineoplastic drugs, a study was developed aiming to determine the 5-fluorouracil (5-FU) contamination on work surfaces of two Portuguese hospitals.
Resumo:
Comportamento alimentar oportunista do marimbá Diplodus argenteus (Perciformes, Sparidae): interação humana-peixe em dois sistemas de costões rochosos do SE e SU do Brasil. Esse artigo aborda dois tipos de comportamentos alimentares do marimbá Diplodus argenteus em dois sistemas de costões rochosos do Atlântico sul no Brasil. Essa espécie alimentou-se sobre o fundo e exibiu comportamentos ocasionais e oportunísticos.
Resumo:
Na Fábrica de Papel da Ponte Redonda fabricam-se sacos de papel multi-folhas e papel reciclado do tipo Kraft. Tendo em consideração a primeira actividade, é de grande interesse optimizar o processo de fabrico de papel com vista a incorporara a máxima taxa de papel produzido internamente nas diferentes camadas dos sacos de papel. Os papéis de maior interesse são os do tipo Fluting e Liners, tendo sido produzidos em 2010 um total de 4,9 mil toneladas, ou seja 90% de todo o papel fabricado em 2010, correspondendo a a 4 mil toneladas de papéis do tipo Liners e 0,9 mil toneladas para os papéis do tipo Fluting. Nos papéis do tipo Liners incluem-se os papéis do tipo Test-Liner e Kraft-Liner, representando em termos produtivos valores idênticos. No âmbito deste trabalho, em que se pretendeu controlar as águas do processo e optimizar a produção de papel, foram introduzidos uma unidade de flutuação e um sistema que permitisse regular a consistência da suspensão fibrosa à entrada da máquina do papel, e foram ainda estudadas as possibilidades de adição de produtos químicos para melhorar as características da pasta assim como um tratamento microbiológico mais eficaz para todo o processo. Para se avaliar se as medidas implementadas teriam um impacto positivo na qualidade desses dois tipos de papéis, desenvolveu-se o trabalho em duas fases: a primeira envolve a introdução de um sistema de flutuação e de um sistema de controlo de consistência da pasta, assim como a selecção de produtos químicos a adicionar ao processo. A segunda fase consistiu na avaliação do efeito destas medidas nas características do papel fabricado. Para o efeito foram escolhidos dois tipos de papel e de diferentes gramagens, nomeadamente Test-Liner de 80 g/m2 e Fluting de 110 g/m2. Introduziu-se um flutuador com o objectivo de tratar parte das águas do processo de fabrico com vista a serem reutilizadas em determinadas aplicações possíveis para a qualidade da água obtida (lavagens e água do processo), de modo a conseguir-se uma poupança de água, assim como aproveitar-se as lamas resultantes, ricas em fibra de celulose, para utilizá-las como matéria-prima. Foi introduzido um regulador de consistência no processo da Ponte Redonda com o objectivo de alimentar de uma forma constante a consistência da pasta à entrada da máquina do papel proporcionando uma melhor formação da folha, devido à ligação entre fibras, na direcção máquina e direcção transversal. Esse sistema inovador é um Regulador de Consistência que vem proporcionar à máquina do papel uma alimentação em fibra mais constante. O fabrico de papel apenas a partir de fibras de celulose não permitirá obter um papel com as características desejadas para a sua utilização. Para corrigir estas deficiências, são adicionados produtos químicos para atribuir ou melhorar as propriedades dos papéis. Desta forma considerou-se interessante introduzir no processo um agente de retenção numa fase posterior à preparação da pasta e antes da chegada à máquina de papel, de forma a melhorar as características da suspensão fibrosa. Assim foi implementado um sistema cuja eficácia foi avaliada. Concluiu-se que com a sua implementação a máquina de papel apresentou melhores resultados na drenagem e na turbidez da água removida, significando uma água com menor teor de matéria suspensa e dissolvida, devido à melhor agregação das fibras dispersas na suspensão fibrosa, levando a um aumento da drenagem e consequentemente melhor eficiência das prensas e secaria. Foi também elaborado um estudo para introdução de um sistema de tratamento microbiológico em todo o processo de fabrico de papel, devido à existência de microorganismos prejudiciais ao seu fabrico. Concluiu-se que a água clarificada proveniente do flutuador apresentou qualidade aceitável para os objectivos pretendidos. No entanto, considerando a eficiência de 26,5% na remoção de sólidos suspensos será necessário mais algum tempo de utilização da água clarificada, cerca de um ano, para avaliar se esta terá algum efeito prejudicial nos equipamentos. Verificou-se que devido à existência de microrganismos em todo o processo de fabrico de papel será necessário efectuar lavagens aos tinões, tanques e circuitos com alguma regularidade, aproveitando-se as paragens do processo assim como implementar um sistema de tratamento microbiológico mais eficaz. Em resultado das medidas implementadas concluiu-se que os papéis produzidos apresentaram melhorias, tendo-se obtido melhores resultados em todos os ensaios de resistência. No papel do tipo Test-Liner destacam-se os bons resultados nos ensaios de superfície, Cobb60 e rebentamento. No caso do parâmetro do Cobb60, foi um resultado surpreendente visto que por norma este tipo de papéis reciclados não suportam este ensaio. Concluiu-se também que as medidas implementadas proporcionaram uma melhor agregação e ligação entre fibras, e melhor formação da folha na máquina do papel proporcionando aos papéis propriedades físico-mecânicas mais interessantes.
Resumo:
O objectivo desta tese é dimensionar um secador em leito fluidizado para secagem de cereais, nomeadamente, secagem de sementes de trigo. Inicialmente determinaram-se as condições de hidrodinâmica (velocidade de fluidização, TDH, condições mínimas de “slugging”, expansão do leito, dimensionamento do distribuidor e queda de pressão). Com as condições de hidrodinâmica definidas, foi possível estimar as dimensões físicas do secador. Neste ponto, foram realizados estudos relativamente à cinética da secagem e à própria secagem. Foi também estudado o transporte pneumático das sementes. Deste modo, determinaram-se as velocidades necessárias ao transporte pneumático e respectivas quedas de pressão. Por fim, foi realizada uma análise custos para que se soubesse o custo deste sistema de secagem. O estudo da secagem foi feito para uma temperatura de operação de 50ºC, tendo a ressalva que no limite se poderia trabalhar com 60ºC. A velocidade de operação é de 2,43 m/s, a altura do leito fixo é de 0,4 m, a qual sofre uma expansão durante a fluidização, assumindo o valor de 0,79 m. O valor do TDH obtido foi de 1,97 m, que somado à expansão do leito permite obter uma altura total da coluna de 2,76 m. A altura do leito fixo permite retirar o valor do diâmetro que é de 0,52 m. Verifica-se que a altura do leito expandido é inferior à altura mínima de “slugging” (1,20 m), no entanto, a velocidade de operação é superior à velocidade mínima de “slugging” (1,13 m/s). Como só uma das condições mínimas é cumprida, existe a possibilidade da ocorrência de “slugging”. Finalmente, foi necessário dimensionar o distribuidor, que com o diâmetro de orifício de 3 mm, valor inferior ao da partícula (3,48 mm), permite a distruibuição do fluido de secagem na coluna através dos seus 3061 orifícios. O inicio do estudo da secagem centrou-se na determinação do tempo de secagem. Além das duas temperaturas atrás referidas, foram igualmente consideradas duas humidades iniciais para os cereais (21,33% e 18,91%). Temperaturas superiores traduzem-se em tempos de secagem inferiores, paralelamente, teores de humidade inicial inferiores indicam tempos menores. Para a temperatura de 50ºC, os tempos de secagem assumiram os valores de 2,8 horas para a 21,33% de humidade e 2,7 horas para 18,91% de humidade. Foram também tidas em conta três alturas do ano para a captação do ar de secagem, Verão e Inverno representando os extremos, e a Meia- Estação. Para estes três casos, foi possível verificar que a humidade específica do ar não apresenta alterações significativas entre a entrada no secador e a corrente de saída do mesmo equipamento, do mesmo modo que a temperatura de saída pouco difere da de entrada. Este desvio de cerca de 1% para as humidades e para as temperaturas é explicado pela ausência de humidade externa nas sementes e na pouca quantidade de humidade interna. Desta forma, estes desvios de 1% permitem a utilização de uma razão de reciclagem na ordem dos 100% sem que o comportamento da secagem se altere significativamente. O uso de 100% de reciclagem permite uma poupança energética de cerca de 98% no Inverno e na Meia-Estação e de cerca de 93% no Verão. Caso não fosse realizada reciclagem, seria necessário fornecer à corrente de ar cerca de 18,81 kW para elevar a sua temperatura de 20ºC para 50ºC (Meia-Estação), cerca de 24,67 kW para elevar a sua temperatura de 10ºC para 50ºC (Inverno) e na ordem dos 8,90 kW para elevar a sua temperatura dos 35ºC para 50ºC (Verão). No caso do transporte pneumático, existem duas linhas, uma horizontal e uma vertical, logo foi necessário estimar o valor da velocidade das partículas para estes dois casos. Na linha vertical, a velocidade da partícula é cerca de 25,03 m/s e cerca de 35,95 m/s na linha horizontal. O menor valor para a linha vertical prende-se com o facto de nesta zona ter que se vencer a força gravítica. Em ambos os circuitos a velocidade do fluido é cerca de 47,17 m/s. No interior da coluna, a velocidade do fluido tem o valor de 10,90 m/s e a velocidade das partículas é de 1,04 m/s. A queda de pressão total no sistema é cerca de 2408 Pa. A análise de custos ao sistema de secagem indicou que este sistema irá acarretar um custo total (fabrico mais transporte) de cerca de 153035€. Este sistema necessita de electricidade para funcionar, e esta irá acarretar um custo anual de cerca de 7951,4€. Embora este sistema de secagem apresente a possibilidade de se realizar uma razão de reciclagem na ordem dos 100% e também seja possível adaptar o mesmo para diferentes tipos de cereais, e até outros tipos de materiais, desde que possam ser fluidizados, o seu custo impede que a realização deste investimento não seja atractiva, especialmente tendo em consideração que se trata de uma instalação à escala piloto com uma capacidade de 45 kgs.
Resumo:
Ciguatera fish poisoning (CFP) is a syndrome caused by the ingestion of fish contaminated with Ciguatoxins (CTXs). These phycotoxins are produced mainly by dinoflagellates that belong to the genus Gambierdiscus that are transformed in more toxic forms in predatory fish guts, and are more present in the Indo-Pacific and Caribbean areas. It is estimated that CFP causes per year more than 10,000 intoxications worldwide. With the rise of water temperature and anthropogenic intervention, it is important to study the prevalence of CFP in more temperate waters. Through inter- and subtidal sampling, 22 species of organisms were collected, in Madeira and Azores archipelagos and in the northwestern Moroccan coast, during September of 2012 and June and July of 2013. A total of 94 samples of 22 different species of bivalves, gastropods, echinoderms and crustaceans where analyzed by Ultra Performance Liquid Chromatography-Mass Spectometry-Ion Trap-Time of Flight (UPLC-MS-IT-TOF) and Ultra Performance Chromatography- Mass Spectrometry (UPLC-MS). Our main aim was to detect new vectors and ascertain if there were some geographical differences. We detected for the first time putative CTXs in echinoderms, in two starfish species—M. glacialis and O. ophidianus. We detected differences regarding uptake values by organisms and geographical location. Toxin amounts were significant, showing the importance and the need for continuity of these studies to gain more knowledge about the prevalence of these toxins, in order to better access human health risk. In addition, we suggest monitoring of these toxins should be extended to other vectors, starfish being a good alternative for protecting and accessing human health risk.
Resumo:
The presence of filamentous fungi was detected in wastewater and air collected at wastewater treatment plants (WWTP) from several European countries. The aim of the present study was to assess fungal contamination in two WWTP operating in Lisbon. In addition, particulate matter (PM) contamination data was analyzed. To apply conventional methods, air samples from the two plants were collected through impaction using an air sampler with a velocity air rate of 140 L/min. Surfaces samples were collected by swabbing the surfaces of the same indoor sites. All collected samples were incubated at 27°C for 5 to 7 d. After lab processing and incubation of collected samples, quantitative and qualitative results were obtained with identification of the isolated fungal species. For molecular methods, air samples of 250 L were also collected using the impinger method at 300 L/min airflow rate. Samples were collected into 10 ml sterile phosphate-buffered saline with 0.05% Triton X-100, and the collection liquid was subsequently used for DNA extraction. Molecular identification of Aspergillus fumigatus and Stachybotrys chartarum was achieved by real-time polymerase chain reaction (RT-PCR) using the Rotor-Gene 6000 qPCR Detection System (Corbett). Assessment of PM was also conducted with portable direct-reading equipment (Lighthouse, model 3016 IAQ). Particles concentration measurement was performed at five different sizes: PM0.5, PM1, PM2.5, PM5, and PM10. Sixteen different fungal species were detected in indoor air in a total of 5400 isolates in both plants. Penicillium sp. was the most frequently isolated fungal genus (58.9%), followed by Aspergillus sp. (21.2%) and Acremonium sp. (8.2%), in the total underground area. In a partially underground plant, Penicillium sp. (39.5%) was also the most frequently isolated, also followed by Aspergillus sp. (38.7%) and Acremonium sp. (9.7%). Using RT-PCR, only A. fumigatus was detected in air samples collected, and only from partial underground plant. Stachybotrys chartarum was not detected in any of the samples analyzed. The distribution of particle sizes showed the same tendency in both plants; however, the partially underground plant presented higher levels of contamination, except for PM2.5. Fungal contamination assessment is crucial to evaluating the potential health risks to exposed workers in these settings. In order to achieve an evaluation of potential health risks to exposed workers, it is essential to combine conventional and molecular methods for fungal detection. Protective measures to minimize worker exposure to fungi need to be adopted since wastewater is the predominant internal fungal source in this setting.
Resumo:
OBJECTIVE:To analyze factors associated with cervical cancer screening failure. METHODS:Population-based cross-sectional study with self-weighted two-stage cluster sampling conducted in the cities of Fortaleza (Northeastern Brazil) and Rio de Janeiro (Southeastern Brazil) in 2002. Subjects were women aged 25-59 years in the last three years prior to the study. Data were analyzed through Poisson regression using a hierarchical model. RESULTS: The proportion of women who did not undergo the Pap smear test in Fortaleza and Rio de Janeiro was 19.1% (95% CI: 16.1;22.1) and 16.5% (95% CI: 14.1;18.9), respectively. Higher prevalence ratios of cervical cancer screening failure in both cities were seen among women with low education and low per capita income, old age, unmarried, who never underwent mammography, clinical breast examination, and blood glucose and cholesterol level testing. Smokers also had lower screening rates compared to non-smoker women and this difference was only statistically significant in Rio de Janeiro. CONCLUSIONS:The study findings point to the need of intervention focusing particularly women in worse socioeconomic conditions and access to healthcare, old-aged and unmarried. Education activities must prioritize screening of asymptomatic women and early diagnosis for symptomatic women and access to adequate diagnostic methods and treatment should be provided.
Resumo:
Este trabalho teve como propósito fazer uma avaliação do desempenho energético e da qualidade do ar no interior das instalações de uma Piscina Municipal Coberta, localizada na zona norte de Portugal, sendo estabelecidos os seguintes objetivos: caracterização geral da piscina, no que respeita aos seus diferentes espaços e equipamentos, cálculo dos consumos térmicos e elétricos bem como o registo das concentrações de elementos poluentes para controlo da qualidade do ar no interior da piscina, tendo como base a legislação atualmente em vigor. A caracterização geral da piscina permitiu verificar algumas inconformidades como a temperatura da água nos tanques de natação que tem valores superiores aos recomendados e a sala de primeiros socorros que não possui acesso direto ao exterior. Acrescente-se que o pavimento nos chuveiros da casa de banho feminina e os valores de pH para água do tanque grande e pequeno não estão sempre dentro da gama de recomendação. O caudal da renovação de ar está a ser operado manualmente e quando está a funcionar a 50% da sua capacidade máxima, que acontece numa parte do dia, apenas consegue renovar 77,5% do caudal recomendado pelo RSECE. Para se obter o valor recomendado é necessário ter pelo menos 7 horas com o caudal a 100% da capacidade máxima. A avaria na UTA2 originou que 40% dos registos diários da humidade relativa interior estivessem fora da gama de valores recomendados e que esta é fortemente dependente da humidade no exterior e pode ser agravada quando as portas dos envidraçados da nave são abertas. Analisando ainda a quantidade de água removida na desumidificação do ar com a água evaporada em condições de Outono-Inverno ou Primavera-Verão, este estudo permitiu concluir que todas as combinações demonstraram a necessidade de desumidificação salvo a combinação Outono-Inverno e UTA2 a funcionar a 100% da sua capacidade máxima. Os isolamentos das tubagens na sala das caldeiras foram observados e comparados com as soluções recomendadas pelas empresas especialistas e verificou-se que alguns estão mal colocados com parcial ou total degradação, promovendo perdas térmicas. No caso das perdas calorificas por evaporação, estas representaram cerca de 67,78% das perdas totais. Como tal, estudou-se a aplicação de uma cobertura sobre o plano de água durante o período de inatividade da piscina (8 horas) e verificou-se que o resultado seria uma poupança de 654,8 kWh/dia, na ausência de evaporação da água, mais 88,00 kWh/dia do período da UTA2 a funcionar a 50% da sua capacidade, perfazendo um total de 742,8 kWh/dia. A aplicação da cobertura permite obter um VAL de valor positivo, uma TIR de 22,77% e sendo este valor superior ao WACC (Weight Average Cost of Capital), o projeto torna-se viável com um Pay-Back de 3,17 anos. Caracterizou-se também o consumo total diário em eletricidade, e verificou-se que as unidades de climatização, as bombas de circulação de água, a iluminação, e outros equipamentos representam, respetivamente, cerca de 67,81, 25,26, 2,68 e 3,91% da energia elétrica total consumida. Por fim, a análise à qualidade do ar no interior da nave em Maio e Setembro identificou que as concentrações de ozono apresentavam valores no limite do aceitável em Maio e superiores ao valor de emissão em Setembro. Os compostos orgânicos voláteis também apresentavam valores em Maio 4,98 vezes superior e em Setembro 6,87 vezes superior aos valores máximos exigidos pelo D.L. nº 79/2006. Houve ainda altas concentrações de radão registadas na casa dos filtros, em Maio com um valor 11,49 vezes superior, no entanto esse valor desceu em Setembro para 1,08 vezes, mesmo assim superior ao exigido pelo D.L. nº 79/2006.
Resumo:
A geração de trajectórias de robôs em tempo real é uma tarefa muito complexa, não
existindo ainda um algoritmo que a permita resolver de forma eficaz. De facto, há
controladores eficientes para trajectórias previamente definidas, todavia, a adaptação a
variações imprevisíveis, como sendo terrenos irregulares ou obstáculos, constitui ainda um
problema em aberto na geração de trajectórias em tempo real de robôs.
Neste trabalho apresentam-se modelos de geradores centrais de padrões de locomoção
(CPGs), inspirados na biologia, que geram os ritmos locomotores num robô quadrúpede.
Os CPGs são modelados matematicamente por sistemas acoplados de células (ou
neurónios), sendo a dinâmica de cada célula dada por um sistema de equações diferenciais
ordinárias não lineares. Assume-se que as trajectórias dos robôs são constituídas por esta
parte rítmica e por uma parte discreta. A parte discreta pode ser embebida na parte rítmica,
(a.1) como um offset ou (a.2) adicionada às expressões rítmicas, ou (b) pode ser calculada
independentemente e adicionada exactamente antes do envio dos sinais para as articulações
do robô. A parte discreta permite inserir no passo locomotor uma perturbação, que poderá
estar associada à locomoção em terrenos irregulares ou à existência de obstáculos na
trajectória do robô. Para se proceder á análise do sistema com parte discreta, será variado o
parâmetro g. O parâmetro g, presente nas equações da parte discreta, representa o offset do
sinal após a inclusão da parte discreta.
Revê-se a teoria de bifurcação e simetria que permite a classificação das soluções
periódicas produzidas pelos modelos de CPGs com passos locomotores quadrúpedes. Nas
simulações numéricas, usam-se as equações de Morris-Lecar e o oscilador de Hopf como
modelos da dinâmica interna de cada célula para a parte rítmica. A parte discreta é
modelada por um sistema inspirado no modelo VITE. Medem-se a amplitude e a
frequência de dois passos locomotores para variação do parâmetro g, no intervalo [-5;5].
Consideram-se duas formas distintas de incluir a parte discreta na parte rítmica: (a) como
um (a.1) offset ou (a.2) somada nas expressões que modelam a parte rítmica, e (b) somada
ao sinal da parte rítmica antes de ser enviado às articulações do robô. No caso (a.1),
considerando o oscilador de Hopf como dinâmica interna das células, verifica-se que a amplitude e frequência se mantêm constantes para -5
Resumo:
XV European Congress of Ichthyology, Porto, Portugal, 7 Sep - 11 Sep, 2015.
Resumo:
The most general Two Higgs Doublet Model potential without explicit CP violation depends on 10 real independent parameters. Excluding spontaneous CP violation results in two 7 parameter models. Although both models give rise to 5 scalar particles and 2 mixing angles, the resulting phenomenology of the scalar sectors is different. If flavour changing neutral currents at tree level are to be avoided, one has, in both cases, four alternative ways of introducing the fermion couplings. In one of these models the mixing angle of the CP even sector can be chosen in such a way that the fermion couplings to the lightest scalar Higgs boson vanishes. At the same time it is possible to suppress the fermion couplings to the charged and pseudo-scalar Higgs bosons by appropriately choosing the mixing angle of the CP odd sector. We investigate the phenomenology of both models in the fermiophobic limit and present the different branching ratios for the decays of the scalar particles. We use the present experimental results from the LEP collider to constrain the models.
Resumo:
We show that in two Higgs doublet models at tree-level the potential minimum preserving electric charge and CP symmetries, when it exists, is the global one. Furthermore, we derived a very simple condition, involving only the coefficients of the quartic terms of the potential, that guarantees spontaneous CP breaking. (C) 2004 Elsevier B.V. All rights reserved.
Resumo:
Filamentous fungi from genus Aspergillus were previously detected in wastewater treatment plants (WWTP) as being Aspergillus flavus (A. flavus), an important toxigenic fungus producing aflatoxins. This study aimed to determine occupational exposure adverse effects due to fungal contamination produced by A. flavus complex in two Portuguese WWTP using conventional and molecular methodologies. Air samples from two WWTP were collected at 1 m height through impaction method. Surface samples were collected by swabbing surfaces of the same indoor sites. After counting A. flavus and identification, detection of aflatoxin production was ensured through inoculation of seven inoculates in coconut-milk agar. Plates were examined under long-wave ultraviolet (UV; 365 nm) illumination to search for the presence of fluorescence in the growing colonies. To apply molecular methods, air samples were also collected using the impinger method. Samples were collected and collection liquid was subsequently used for DNA extraction. Molecular identification of A. flavus was achieved by real-time polymerase chain reaction (RT-PCR) using the Rotor-Gene 6000 qPCR detection system (Corbett). Among the Aspergillus genus, the species that were more abundant in air samples from both WWTP were Aspergillus versicolor (38%), Aspergillus candidus (29.1%), and Aspergillus sydowii (12.7%). However, the most commonly species found on surfaces were A. flavus (47.3%), Aspergillus fumigatus (34.4%), and Aspergillus sydowii (10.8%). Aspergillus flavus isolates that were inoculated in coconut agar medium were not identified as toxigenic strains and were not detected by RT-PCR in any of the analyzed samples from both plants. Data in this study indicate the need for monitoring fungal contamination in this setting. Although toxigenic strains were not detected from A. flavus complex, one cannot disregard the eventual presence and potential toxicity of aflatoxins.
Resumo:
Despite the classification as known or suspected human carcinogens, by the International Agency for Research on Cancer, the antineoplastic drugs are extensively used in cancer treatment due to their specificity and efficacy. As human carcinogens, these drugs represent a serious threat to the healthcare workers involved in their preparation and administration. This work aims to contribute to better characterize the occupational exposure of healthcare professionals to antineoplastic drugs, by assessing workplace surfaces contamination of pharmacy and administration units of two Portuguese hospitals. Surface contamination was assessed by the determination of cyclophosphamide, 5-fluorouracil, and paclitaxel. These three drugs were used as surrogate markers for surfaces contamination by cytotoxic drugs. Wipe samples were taken and analyzed by HPLCDAD. From the total of 327 analyzed samples, in 121 (37%) was possible to detect and quantify at least one drug. Additionally, 28 samples (8.6 %) indicate contamination by more than one antineoplastic drug, mainly in the administration unit, in both hospitals. Considering the findings in both hospitals, specific measures should be taken, particularly those related with the promotion of good practices and safety procedures and also routine monitoring of surfaces contamination in order to guarantee the appliance of safety measures.
Resumo:
OBJECTIVE: To diagnose iron deficiency anemia in children. METHODS: The study was conducted with a sample of 301 children aged six to 30 months attending public daycare centers in the city of Recife, Northeast Brazil, in 2004. The diagnoses of anemia were based on a combination of different hematological and biochemical parameters: hemoglobin, mean corpuscular volume, ferritin, C-reactive protein, transferrin saturation and transferrin receptor. The chi-square test and ANOVA were used in the statistical analysis. RESULTS: Of all children studied, 92.4% had anemia (Hb <110 g/L) and 28.9% had moderate/severe anemia (Hb <90 g/L). Lower levels of hemoglobin were found in children aged 6-17 months. Iron deficiency was found in 51.5% of children using ferritin (<12 μg/L) as parameter. Taking into consideration the combination of hemoglobin level, ferritin and transferrin receptor, 58.1% had anemia with iron deficiency, 34.2% had anemia without iron deficiency and 2.3% had iron deficiency without anemia. Mean ferritin concentration was significantly higher in children with high C-reactive protein when compared with those with normal levels (22.1 vs. 14.8 µg/L). CONCLUSIONS: The use of several biochemical and hematological parameters allowed to diagnosing iron deficiency anemia in two thirds of children, suggesting a need to identify other determinants of anemia without iron deficiency.