968 resultados para Surface coverage


Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the fabrication of La0.7Ca0.3MnO3 nanotubes (LCMONTs) with a diameter of about 200 nm, by a modified sol-gel method utilizing nanochannel alumina templates. High resolution transmission electron microscopy confirmed that the obtained LCMONTs are made up of nanoparticles (8-12 nm), which are randomly aligned in the wall of the nanotubes. The strong irreversibility between zero field cooling (ZFC) and field cooling (FC) magnetization curves as well as a cusplike peak in the ZFC curve gives strong support for surface spin glass behavior.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Oxygen transfer rate and the corresponding power requirement to operate the rotor are vital for design and scale-up of surface aerators. Present study develops simulation or scale-up criterion correlating the oxygen transsimulation fer coefficient and power number along with a parameter governing theoretical power per unit volume (X, which is defined as equal to (FR1/3)-R-4/3, where F and R are impellers' Fronde and Reynolds number, respectively). Based on such scale-up criteria, design considerations are developed to save energy requirements while designing square tank surface aerators. It has been demonstrated that energy can be saved substantially if the aeration tanks are run at relatively higher input powers. It is also demonstrated that smaller sized tanks are more energy conservative and economical when compared to big sized tanks, while aerating the same volume of water, and at the same time by maintaining a constant input power in all the tanks irrespective of their size. An example illustrating how energy can be reduced while designing different sized aerators is given. The results presented have a wide application in biotechnology and bioengineering areas with a particular emphasis on the design of appropriate surface aeration systems.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Oxygen transfer rate and the corresponding power requirement to operate the rotor are vital for design and scale-up of surface aerators. Present study develops simulation or scale-up criterion correlating the oxygen transsimulation fer coefficient and power number along with a parameter governing theoretical power per unit volume (X, which is defined as equal to (FR1/3)-R-4/3, where F and R are impellers' Fronde and Reynolds number, respectively). Based on such scale-up criteria, design considerations are developed to save energy requirements while designing square tank surface aerators. It has been demonstrated that energy can be saved substantially if the aeration tanks are run at relatively higher input powers. It is also demonstrated that smaller sized tanks are more energy conservative and economical when compared to big sized tanks, while aerating the same volume of water, and at the same time by maintaining a constant input power in all the tanks irrespective of their size. An example illustrating how energy can be reduced while designing different sized aerators is given. The results presented have a wide application in biotechnology and bioengineering areas with a particular emphasis on the design of appropriate surface aeration systems.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aeration experiments were conducted in different sized baffled and unbaffled circular surface aeration tanks to study their relative performance on oxygen transfer process while aerating the same volume of water. Experiments were carried out with the objective of ascertaining the effect of baffle on oxygen transfer coefficient k. Simulation equations govern the oxygen transfer coefficient with the theoretical power per unit volume, X and actual power per unit volume, P-V. It has been found that, for any given X, circular tanks with baffle produce higher values of k than unbaffled circular tanks, but in terms of actual power consumption unbaffled tanks consume less power when compared to baffled circular tanks to achieve the same value of k. It has been found that in terms of energy consumption, epsilon, baffled tanks consume more energy than unbaffled tanks at any value of X. This suggests that the unbaffled circular tank gives a better performance as far as energy consumption is concerned and hence better economy. An example illustrating the energy conservation to aerate the same volume of water in both types of aerators is given. (c) 2007 Society of Chemical Industry.