985 resultados para Spectral methods


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The pursuit of high response rates to minimise the threat of nonresponse bias continues to dominate decisions about resource allocation in survey research. Yet a growing body of research has begun to question this practice. In this study, we use previously unavailable data from a new sampling frame based on population registers to assess the value of different methods designed to increase response rates on the European Social Survey in Switzerland. Using sampling data provides information about both respondents and nonrespondents, making it possible to examine how changes in response rates resulting from the use of different fieldwork methods relate to changes in the composition and representativeness of the responding sample. We compute an R-indicator to assess representativity with respect to the sampling register variables, and find little improvement in the sample composition as response rates increase. We then examine the impact of response rate increases on the risk of nonresponse bias based on Maximal Absolute Bias (MAB), and coefficients of variation between subgroup response rates, alongside the associated costs of different types of fieldwork effort. The results show that increases in response rate help to reduce MAB, while only small but important improvements to sample representativity are gained by varying the type of effort. These findings lend further support to research that has called into question the value of extensive investment in procedures aimed at reaching response rate targets and the need for more tailored fieldwork strategies aimed both at reducing survey costs and minimising the risk of bias.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To compare different techniques for positive contrast imaging of susceptibility markers with MRI for three-dimensional visualization. As several different techniques have been reported, the choice of the suitable method depends on its properties with regard to the amount of positive contrast and the desired background suppression, as well as other imaging constraints needed for a specific application. MATERIALS AND METHODS: Six different positive contrast techniques are investigated for their ability to image at 3 Tesla a single susceptibility marker in vitro. The white marker method (WM), susceptibility gradient mapping (SGM), inversion recovery with on-resonant water suppression (IRON), frequency selective excitation (FSX), fast low flip-angle positive contrast SSFP (FLAPS), and iterative decomposition of water and fat with echo asymmetry and least-squares estimation (IDEAL) were implemented and investigated. RESULTS: The different methods were compared with respect to the volume of positive contrast, the product of volume and signal intensity, imaging time, and the level of background suppression. Quantitative results are provided, and strengths and weaknesses of the different approaches are discussed. CONCLUSION: The appropriate choice of positive contrast imaging technique depends on the desired level of background suppression, acquisition speed, and robustness against artifacts, for which in vitro comparative data are now available.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: Pohjois-Euroopan silikaattisten kalkitusaineiden reaktiivisuus astiakoemenetelmällä ja kahdella pH-staattisella menetelmällä arvioituna

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate if heroin and cocaine can be distinguished using dual-energy CT. MATERIALS AND METHODS: Twenty samples of heroin and cocaine at different concentrations and standardized compression (SC) were scanned in dual-energy mode on a newest generation Dual Energy 64-row MDCT scanner. CT number, spectral graphs, and dual-energy index (DEI) were evaluated. Results were prospectively tested on six original samples from a body packer. Wilcoxon's test was used for statistical evaluation. RESULTS: Values are given as median and range. Under SC, the CT number of cocaine samples (-29.87 Hounsfield unit (HU) [-125.85; 16.16 HU]) was higher than the CT number of heroin samples (-184.37 HU [-199.81; -159.25 HU]; p < 0.01). Slope of spectral curves for cocaine was -2.36 HU/keV [-7.15; -0.67 HU/keV], and for heroin, 1.75 HU/keV [1.28; 2.5 HU/keV] (p < 0.01). DEI was 0.0352 [0.0081; 0.0528] for cocaine and significantly higher than for heroin samples (-0.0127 [-0.0097; -0.0159]; p < 0.001). While CT number was inconclusive, all six original packs were correctly classified after evaluation of the spectral curve and DEI. In contrast to the CT number, slope of the spectral curve and DEI were independent of concentration and compression. CONCLUSION: The slope of the spectral curve and the DEI from dual-energy CT data can be used to distinguish heroin and cocaine in vitro; these results are independent of compression and concentration in the measured range.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Radiosurgery (RS) is gaining increasing acceptance in the upfront management of brain metastases (BM). It was initially used in so-called radioresistant metastases (melanoma, renal cell, sarcoma) because it allowed delivering higher dose to the tumor. Now, RS is also used for BM of other cancers. The risk of high incidence of new BM questions the need for associated whole-brain radiotherapy (WBRT). Recent evidence suggests that RS alone allows avoiding cognitive impairment related to WBRT, and the latter should be upheld for salvage therapy. Thus the increase use of RS for single and multiple BM raises new technical challenges for treatment delivery and dosimetry. We present our single institution experience focusing on the criteria that led to patients' selection for RS treatment with Gamma Knife (GK) in lieu of Linac. METHODS: Leksell Gamma Knife Perfexion (Elekta, Sweden) was installed in July 2010. Currently, the Swiss federal health care supports the costs of RS for BM with Linac but not with GK. Therefore, in our center, we always consider first the possibility to use Linac for this indication, and only select patients for GK in specific situations. All cases of BM treated with GK were retrospectively reviewed for criteria yielding to GK indication, clinical information, and treatment data. Further work in progress includes a posteriori dosimetry comparison with our Linac planning system (Brainscan V.5.3, Brainlab, Germany). RESULTS: From July 2010 to March 2012, 20 patients had RS for BM with GK (7 patients with single BM, and 13 with multiple BM). During the same period, 31 had Linac-based RS. Primary tumor was melanoma in 9, lung in 7, renal in 2, and gastrointestinal tract in 2 patients. In single BM, the reason for choosing of GK was the anatomical location close to, or in highly functional areas (1 motor cortex, 1 thalamic, 1 ventricular, 1 mesio-temporal, 3 deep cerebellar close to the brainstem), especially since most of these tumors were intended to be treated with high-dose RS (24 Gy at margin) because of their histology (3 melanomas, 1 renal cell). In multiple BM, the reason for choosing GK in relation with the anatomical location of the lesions was either technical (limitations of Linac movements, especially in lower posterior fossa locations) or closeness of multiple lesions to highly functional areas (typically, multiple posterior fossa BM close to the brainstem), precluding optimal dosimetry with Linac. Again, this was made more critical for multiple BM needing high-dose RS (6 melanoma, 2 hypernephroma). CONCLUSION: Radiosurgery for BM may represent some technical challenge in relation with the anatomical location and multiplicity of the lesions. These considerations may be accentuated for so-called radioresistant BM, when higher dose RS in needed. In our experience, Leksell Gamma Knife Perfexion proves to be useful in addressing these challenges for the treatment of BM.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Plutonium and americium are radionuclides particularly difficult to measure in environmental samples because they are alpha-emitters and therefore necessitate a careful separation before any measurement, either using radiometric methods or ICP-SMS. Recent developments in extraction chromatography resins such as Eichrom (R) TRU and TEVA have resolved many of the analytical problems but drawbacks such as low recovery and spectral interferences still occasionally occur. Here, we report on the use of the new Eichrom (R) DGA resin in association with TEVA resin and high pressure microwave acid leaching for the sequential determination of plutonium and americium in environmental samples. The method results in average recoveries of 83 +/- 15% for plutonium and 73 +/- 22% for americium (n = 60), and a less than 10% deviation from reference values of four IAEA reference materials and three samples from intercomparisons exercises. The method is also suitable for measuring Pu-239 in water samples at the mu Bq/l level, if ICP-SMS is used for the measurement.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Powell Basin is a small oceanic basin located at the NE end of the Antarctic Peninsula developed during the Early Miocene and mostly surrounded by the continental crusts of the South Orkney Microcontinent, South Scotia Ridge and Antarctic Peninsula margins. Gravity data from the SCAN 97 cruise obtained with the R/V Hespérides and data from the Global Gravity Grid and Sea Floor Topography (GGSFT) database (Sandwell and Smith, 1997) are used to determine the 3D geometry of the crustal-mantle interface (CMI) by numerical inversion methods. Water layer contribution and sedimentary effects were eliminated from the Free Air anomaly to obtain the total anomaly. Sedimentary effects were obtained from the analysis of existing and new SCAN 97 multichannel seismic profiles (MCS). The regional anomaly was obtained after spectral and filtering processes. The smooth 3D geometry of the crustal mantle interface obtained after inversion of the regional anomaly shows an increase in the thickness of the crust towards the continental margins and a NW-SE oriented axis of symmetry coinciding with the position of an older oceanic spreading axis. This interface shows a moderate uplift towards the western part and depicts two main uplifts to the northern and eastern sectors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Question: When multiple observers record the same spatial units of alpine vegetation, how much variation is there in the records and what are the consequences of this variation for monitoring schemes to detect change? Location: One test summit in Switzerland (Alps) and one test summit in Scotland (Cairngorm Mountains). Method: Eight observers used the GLORIA protocols for species composition and visual cover estimates in percent on large summit sections (>100 m2) and species composition and frequency in nested quadrats (1 m2). Results: The multiple records from the same spatial unit for species composition and species cover showed considerable variation in the two countries. Estimates of pseudoturnover of composition and coefficients of variation of cover estimates for vascular plant species in 1m x 1m quadrats showed less variation than in previously published reports whereas our results in larger sections were broadly in line with previous reports. In Scotland, estimates for bryophytes and lichens were more variable than for vascular plants. Conclusions: Statistical power calculations indicated that, unless large numbers of plots were used, changes in cover or frequency were only likely to be detected for abundant species (exceeding 10% cover) or if relative changes were large (50% or more). Lower variation could be reached with the point methods and with larger numbers of small plots. However, as summits often strongly differ from each other, supplementary summits cannot be considered as a way of increasing statistical power without introducing a supplementary component of variance into the analysis and hence the power calculations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Light-emitting diodes (LEDs) are taking an increasing place in the market of domestic lighting because they produce light with low energy consumption. In the EU, by 2016, no traditional incandescent light sources will be available and LEDs may become the major domestic light sources. Due to specific spectral and energetic characteristics of white LEDs as compared to other domestic light sources, some concerns have been raised regarding their safety for human health and particularly potential harmful risks for the eye. To conduct a health risk assessment on systems using LEDs, the French Agency for Food, Environmental and Occupational Health & Safety (ANSES), a public body reporting to the French Ministers for ecology, for health and for employment, has organized a task group. This group consisted physicists, lighting and metrology specialists, retinal biologist and ophthalmologist who have worked together for a year. Part of this work has comprised the evaluation of group risks of different white LEDs commercialized on the French market, according to the standards and found that some of these lights belonged to the group risk 1 or 2. This paper gives a comprehensive analysis of the potential risks of white LEDs, taking into account pre-clinical knowledge as well as epidemiologic studies and reports the French Agency's recommendations to avoid potential retinal hazards.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Avalanche forecasting is a complex process involving the assimilation of multiple data sources to make predictions over varying spatial and temporal resolutions. Numerically assisted forecasting often uses nearest neighbour methods (NN), which are known to have limitations when dealing with high dimensional data. We apply Support Vector Machines to a dataset from Lochaber, Scotland to assess their applicability in avalanche forecasting. Support Vector Machines (SVMs) belong to a family of theoretically based techniques from machine learning and are designed to deal with high dimensional data. Initial experiments showed that SVMs gave results which were comparable with NN for categorical and probabilistic forecasts. Experiments utilising the ability of SVMs to deal with high dimensionality in producing a spatial forecast show promise, but require further work.