975 resultados para Semiconducting Silicon
Resumo:
A system comprised of a Bomem interferometer and a LT3-110 Heli-Tran cryostat was set up to measure the reflectance of materials in the mid-infrared spectral region. Several tests were conducted to ensure the consistency and reliability of the system. Silicon and Chromium, two materials with well known optical properties were measured to test the accuracy of the system, and the results were found to be in good agreement with the literature. Reflectance measurements on pure SnTe and several Pb and Mn-doped alloys were carried out. These materials were chosen because they exhibit a strong plasma edge in the mid infrared region. The optical conductivity and several related optical parameters were calculated from the measured reflectance. Very low temperature measurements were carried out in the far-infrared on Sn9SMn2Te, and the results are indicative of a spin glass phase at 0.8 K. Resistivity measurements were made at room temperature. The resistivity values were found, as expected, to decrease with increasing carrier concentration and to increase with increasing manganese concentration.
Resumo:
Silicon carbide, which has many polytypic modifications of a very simple and very symmetric structure, is an excellent model system for exploring, the relationship between chemical shift, long-range dipolar shielding, and crystal structure in network solids. A simple McConnell equation treatment of bond anisotropy effects in a poly type predicts chemical shifts for silicon and carbon sites which agree well with the experiment, provided that contributions from bonds up to 100 A are included in the calculation. The calculated chemical shifts depend on three factors: the layer stacking sequence, electrical centre of gravity, and the spacings between silicon and carbon layers. The assignment of peaks to lattice sites is proved possible for three polytypes (6H, 15R, and 3C). The fact that the calculated chemical shifts are very sensitive to layer spacings provides us a potential way to detennine and refine a crystal structure. In this work, the layer spacings of 6H SiC have been calculated and are within X-ray standard deviations. Under this premise, the layer spacings of 15R have been detennined. 29Si and 13C single crystal nmr studies of 6H SiC polytype indicate that all silicons and carbons are magnetically anisotropic. The relationship between a magnetic shielding tensor component and layer spacings has been derived. The comparisons between experimental and semi-empirical chemical shielding tensor components indicate that the paramagnetic shielding of silicon should be included in the single crystal chemical shift calculation.
Resumo:
Hepatocellular Carcinoma (HCC) is a major healthcare problem, representing the third most common cause of cancer-related mortality worldwide. Chronic infections with Hepatitis B virus (HBV) and/or Hepatitis C virus (HCV) are the major risk factors for the development of HCC. The incidence of HBV -associated HCC is in decline as a result of an effective HBV vaccine; however, since an equally effective HCV vaccine has not yet been developed, there are 130 million HCV infected patients worldwide who are at a high-risk for developing HCC. Because reliable parameters and/or tools for the early detection of HCC among high-risk individuals are severely lacking, HCC patients are always diagnosed at a late stage where surgical solutions or effective treatment are not possible. Using urine as a non-invasive sample source, two different approaches (proteomic-based and genomic-based approaches) were pursued with the common goal of discovering potential biomarker candidates for the early detection of HCC among high-risk chronic HCV infected patients. Urine was collected from 106 HCV infected Egyptian patients, 32 of whom had already developed HCC and 74 patients who were diagnosed as HCC-free at the time of initial sample collection. In addition to these patients, urine samples were also collected from 12 healthy control individuals. Total urinary proteins, Trans-renal nucleic acid (Tr-NA) and microRNA (miRNA) were isolated from urine using novel methodologies and silicon carbide-loaded spin columns. In the first, "proteomic-based", approach, liquid chromatography coupled with tandem mass spectrometry (LC-MS/MS) was used to identify potential candidates from pooled urine samples. This was followed by validating relative expression levels of proteins present in urine among all the patients using quantitative real time-PCR (qRT-PCR). This approach revealed that significant over-expression of three proteins: DJ-1, Chromatin Assembly Factor-1 (CAF-1) and 11 Moemen Abdalla HCC Biomarkers Heat Shock Protein 60 (HSP60), were characteristic events among HCC-post HCV infected patients. As a single-based HCC biomarker, CAF-1 over-expression identified HCC among HCV infected patients with a specificity of 90%, sensitivity of 66% and with an overall diagnostic accuracy of 78%. Moreover, the CAF-lIHSP60 tandem identified HCC among HCV infected patients with a specificity of 92%, sensitivity of 61 % and with an overall diagnostic accuracy of 77%. In the second genomic-based approach, two different approaches were processed. The first approach was the miRNA-based approach. The expression levels of miRNAs isolated from urine were studied using the Illumina MicroRNA Expression Profiling Assay. This was followed by qRT-PCR-based validation of deregulated expression of identified miRNA candidates among all the patients. This approach shed the light on the deregulated expression of a number of miRNAs, which may have a role in either the development of HCC among HCV infected patients (i.e. miR-640, miR-765, miR-200a, miR-521 and miR-520) or may allow for a better understanding of the viral-host interaction (miR-152, miR-486, miR-219, miR452, miR-425, miR-154 and miR-31). Moreover, the deregulated expression of both miR-618 and miR-650 appeared to be a common event among HCC-post HCV infected patients. The results of the search for putative targets of these two miRNA suggested that miR-618 may be a potent oncogene, as it targets the tumor-suppressor gene Low density lipoprotein-related protein 12 (LPR12), while miR-650 may be a potent tumor-suppressor gene, as it is supposed to downregulate the TNF receptor-associated factor-4 (TRAF4) oncogene. The specificity of miR-618 and miR-650 deregulated expression patterns for the early detection of HCC among HCV infected patients was 68% and 58%, respectively, whereas the sensitivity was 64% and 72%, respectively. When the deregulated expression of both miRNAs was combined as a tandem biomarker, the specificity and the sensitivity were 75% and 58% respectively. 111 Moemen Abdalla HCC Biomarkers In the second, "Trans-renal nucleic acid-based", approach, the urinary apoptotic nucleic acid (uaNA) levels of 70ng/mL or more were found to be a good predictor of HCC among chronic HCV infected patients. The specificity and the sensitivity of this diagnostic approach were 76% and 86%, respectively, with an overall diagnostic value of 81 %. The uaNA levels positively correlated to HCC disease progression as monitored by epigenetic changes of a panel of eight tumor-suppressor genes (TSGs) using methylation-sensitive PCR. Moreover, the pairing of high uaNA levels (:::: 70 ng/mL) and CAF-1 over-expreSSIOn produced a highly specific (l 00%) multiple-based HCC biomarker with an acceptable sensitivity of 64%, and with a diagnostic accuracy of 82%. In comparison to the previous pairing, the uaNA levels (:::: 70 ng/mL) in tandem with HSP60 over-expression was less specific (89%) but highly sensitive (72%), resulting in a diagnostic accuracy of 64%. The specificities of miR-650 deregulated expression in combination with either high uaNA content or HSP 60 over-expression were 82% and 79%, respectively, whereas, the sensitivities of these combinations were 64% and 58%, respectively. The potential biomarkers identified in this study compare favorably with the diagnostic accuracy of the a-fetoprotein levels test, which has a specificity of 75%, sensitivity of 68% and an overall diagnostic accuracy of 70%. Here we present an intriguing study which shows the significance of using urine as a noninvasive sample source for the identification of promising HCC biomarkers. We have also introduced new techniques for the isolation of different urinary macromolecules, especially miRNA, from urine. Furthermore, we strongly recommend the potential biomarkers indentified in this study as focal points of any future research on HCC diagnosis. A larger testing pool will determine if their use is practical for mass population screening. This explorative study identified potential targets that merit further investigation for the development of diagnostically accurate biomarkers isolated from 1-2 mL urine samples that were acquired in a non-invasive manner.
Resumo:
A room temperature ferromagnetic hysteresis is observed in single crystal strontium titanate substrates as purchased from several manufacturers. It was found that polishing all sides of the substrates removed this observed hysteresis, suggesting that the origin of the ferromagnetic behavior resides on the surface of the substrates. X-ray diffraction and energy dispersive x-ray spectra were measured however they were unable to detect any impurity phases. In similar semiconducting oxides it was previously suggested that ferromagnetism could originate in oxygen vacancies or from disorder within the single crystal. To this end substrates were annealed in both air and vacuum in a range of temperatures (600°C to 1100°G) to both create bulk oxygen vacancies and to heal surface damage. Annealing in vacuum was found to create a measureable number of oxygen vacancies however their creation could not be correlated to the ferromagnetic signal of the substrate. Annealing in air was found to effect the remnant moment of the substrate as well as the width of the x-ray diffraction peaks on the unpolished face, weakly suggesting a relation between surface based disorder and ferromagnetism. Argon ion bombardment was employed to create a layer of surface disorder in the polished crystal, however it was not found to induce ferromagnetism. It was found that acid etching was sufficient to remove the ferromagnetism from as purchased samples and similarly simulated handling with stainless steel tweezers was sufficient to re-create the ferromagnetism. It is suggested that the origin of this ferromagnetism in SrTi03 is surface contaminants (mainly iron).
Resumo:
We report the results of crystal structure, magnetization and resistivity measurements of Bi doped LaVO3. X-ray diffraction (XRD) shows that if doping Bi in the La site is less than ten percent, the crystal structure of La1-xBixVO3 remains unchanged and its symmetry is orthorhombic. However, for higher Bi doping (>10%) composite compounds are found where the XRD patterns are characterized by two phases: LaVO3+V2O3. Energy-dispersive analysis of the x-ray spectroscopy (EDAX) results are used to find a proper atomic percentage of all samples. The temperature dependence of the mass magnetization of pure and single phase doped samples have transition temperatures from paramagnetic to antiferromagnetic region at TN=140 K. This measurement for bi-phasic samples indicates two transition temperatures, at TN=140 K (LaVO3) and TN=170 K (V2O3). The temperature dependence of resistivity reveals semiconducting behavior for all samples. Activation energy values for pure and doped samples are extracted by fitting resistivity versus temperature data in the framework of thermal activation process.
Resumo:
Immobilized lipase B from Candida antarctica (Novozym® 435, N435) was utilized as part of a chemoenzymatic strategy for the synthesis of branched polyesters based on a cyclotetrasiloxane core in the absence of solvent. Nuclear magnetic resonance spectroscopy and matrix-assisted laser desorption ionization time-of-flight mass spectrometry were utilized to monitor the reactions between tetraester cyclotetrasiloxanes and aliphatic diols. The enzyme-mediated esterification reactions can achieve 65– 80% consumption of starting materials in 24–48 h. Longer reaction times, 72–96 h, resulted in the formation of cross-linked gel-like networks. Gel permeation chromatography of the polymers indicated that the masses were Mw ¼ 11 400, 13 100, and 19 400 g mol 1 for the substrate pairs of C7D4 ester/ octane-1,8-diol, C10D4 ester/pentane-1,5-diol and C10D4 ester/octane-1,8-diol respectively, after 48 h. Extending the polymerization for an additional 24 h with the C10D4 ester/octane-1,8-diol pair gave Mw ¼ 86 800 g mol 1. To the best of our knowledge this represents the first report using lipase catalysis to produce branched polymers that are built from a cyclotetrasiloxane core.
Resumo:
Studies have demonstrated that the oxysterol binding protein (OSBP) acts as a phosphatidylinositol phosphate (PIP)-sterol exchanger at membrane contact sites (MCS) of the endoplasmic reticulum (ER) and Golgi. OSBP is known to pick up phosphatidylinositol-4-phosphate (PI(4)P) from the ER, transfer it to the trans-Golgi in exchange for a cholesterol molecule that is then transferred from the trans-Golgi to the ER. Upon further examination of this pathway by Ridgway et al. (1), it appeared that phosphorylation of OSBP played a role in the localization of OSBP. The dephosphorylation state of OSBP was linked to Golgi localization and the depletion of cholesterol at the ER. To mimic the phosphorylated state of OSBP, the mutant OSBP-S5E was designed by Ridgway et al. (1). The lipid and sterol recognition by wt-OSBP and its phosphomimic mutant OSBP-S5E were investigated using immobilized lipid bilayers and dual polarization interferometry (DPI). DPI is a technique in which the protein binding affinity to immobilized lipid bilayers is measured and the binding behavior is examined through real time. Lipid bilayers containing 1,2-dioleoyl-sn-glycero-3-phosphocholine (DOPC) and varying concentrations of PI(4)Ps or sterols (cholesterol or 25-hydroxycholesterol) were immobilized on a silicon nitride chip. It was determined that wt-OSBP binds differently to PI(4)P-containing bilayers compared to OSBP-S5E. The binding behavior suggested that wt-OSBP extracts PI(4)P and the change in the binding behavior, in the case of OSBP-S5E, suggested that the phosphorylation of OSBP may prevent the recognition and/or extraction of PI(4)P. In the presence of sterols, the overall binding behavior of OSBP, regardless of phosphorylation state, was fairly similar. The maximum specific bound mass of OSBP to sterols did not differ as the concentration of sterols increased. However, comparing the maximum specific bound mass of OSBP to cholesterol with oxysterol (25-hydroxycholesterol), OSBP displayed nearly a 2-fold increase in bound mass. With the absence of the wt-OSBP-PI(4)P binding behavior, it can be speculated that the sterols were not extracted. In addition, the binding behavior of OSBP was further tested using a fluorescence based binding assay. Using 22-(N-(7-nitrobenz-2-oxa-1,3-diazol-4-yl)amino)-23,24-bisnor-5-cholen-3β-ol (22-NBD cholesterol), wt-OSBP a one site binding dissociation constant Kd, of 15 ± 1.4 nM was determined. OSBP-S5E did not bind to 22-NBD cholesterol and Kd value was not obtained.
Resumo:
Tesis (Maestría en Ciencias, con especialidad en Química Analítica) U.A.N.L.
Resumo:
Tesis (Maestría en Ciencias, con especialidad en Ingeniería Nuclear). U. A. N. L.
Resumo:
FRANCAIS: L'observation d'une intense luminescence dans les super-réseaux de Si/SiO2 a ouvert de nouvelles avenues en recherche théorique des matériaux à base de silicium, pour des applications éventuelles en optoélectronique. Le silicium dans sa phase cristalline possède un gap indirect, le rendant ainsi moins intéressant vis-à-vis d'autres matériaux luminescents. Concevoir des matériaux luminescents à base de silicium ouvrira donc la voie sur de multiples applications. Ce travail fait état de trois contributions au domaine. Premièrement, différents modèles de super-réseaux de Si/SiO2 ont été conçus et étudiés à l'aide de calculs ab initio afin d'en évaluer les propriétés structurales, électroniques et optiques. Les deux premiers modèles dérivés des structures cristallines du silicium et du dioxyde de silicium ont permis de démontrer l'importance du rôle de l'interface Si/SiO2 sur les propriétés optiques. De nouveaux modèles structurellement relaxés ont alors été construits afin de mieux caractériser les interfaces et ainsi mieux évaluer la portée du confinement sur les propriétés optiques. Deuxièmement, un gap direct dans les modèles structurellement relaxés a été obtenu. Le calcul de l'absorption (par l'application de la règle d'or de Fermi) a permis de confirmer que les propriétés d'absorption (et d'émission) du silicium cristallin sont améliorées lorsque celui-ci est confiné par le SiO2. Un décalage vers le bleu avec accroissement du confinement a aussi été observé. Une étude détaillée du rôle des atomes sous-oxydés aux interfaces a de plus été menée. Ces atomes ont le double effet d'accroître légèrement le gap d'énergie et d'aplanir la structure électronique près du niveau de Fermi. Troisièmement, une application directe de la théorique des transitions de Slater, une approche issue de la théorie de la fonctionnelle de la densité pour des ensembles, a été déterminée pour le silicium cristallin puis comparée aux mesures d'absorption par rayons X. Une très bonne correspondance entre cette théorie et l'expérience est observée. Ces calculs ont été appliqués aux super-réseaux afin d'estimer et caractériser leurs propriétés électroniques dans la zone de confinement, dans les bandes de conduction.
Resumo:
La réalisation de dispositifs à des dimensions sous-micrométriques et nanométriques demande une maîtrise parfaite des procédés de fabrication, notamment ceux de gravure. La réalisation des ces dispositifs est complexe et les exigences en termes de qualité et de géométrie des profils de gravure imposent de choisir les conditions opératoires les mieux adaptées. Les simulations de l'évolution spatio-temporelle des profils de gravure que nous proposons dans cette thèse s'inscrivent parfaitement dans ce contexte. Le simulateur que nous avons réalisé offre la possibilité de mieux comprendre les processus qui entrent en jeu lors de la gravure par plasma de profils dans divers matériaux. Il permet de tester l'influence des paramètres du plasma sur la forme du profil et donc de déterminer les conditions opératoires optimales. La mise au point de ce simulateur s'appuie sur les concepts fondamentaux qui gouvernent la gravure par plasma. À partir de l'état des lieux des différentes approches numériques pouvant être utilisées, nous avons élaboré un algorithme stable et adaptable permettant de mettre en évidence l'importance de certains paramètres clés pour la réalisation de profils de gravure par un plasma à haute densité et à basse pression. Les capacités de cet algorithme ont été testées en étudiant d'une part la pulvérisation de Si dans un plasma d'argon et d'autre part, la gravure chimique assistée par les ions de SiO2/Si dans un plasma de chlore. Grâce aux comparaisons entre profils simulés et expérimentaux, nous avons montré l'importance du choix de certains paramètres, comme la nature du gaz utilisé et la pression du plasma, la forme initiale du masque, la sélectivité masque/matériau, le rapport de flux neutre/ion, etc. Nous avons aussi lié ces paramètres à la formation de défauts dans les profils, par exemple celle de facettes sur le masque, de parois concaves, et de micro-tranchées. Enfin, nous avons montré que le phénomène de redépôt des atomes pulvérisés entre en compétition avec la charge électrique de surface pour expliquer la formation de profils en V dans le Pt pulvérisé par un plasma d'argon.
Resumo:
Les détecteurs ATLAS-MPX sont des détecteurs Medipix2-USB recouverts de convertisseurs de fluorure de lithium et de polyéthylène pour augmenter l’efficacité de détection des neutrons lents et des neutrons rapides respectivement. Un réseau de quinze détecteurs ATLAS-MPX a été mis en opération dans le détecteur ATLAS au LHC du CERN. Deux détecteurs ATLAS-MPX de référence ont été exposés à des sources de neutrons rapides 252 Cf et 241 AmBe ainsi qu’aux neutrons rapides produits par la réaction 7Li(p, xn) pour l’étude de la réponse du détecteur à ces neutrons. Les neutrons rapides sont principalement détectés à partir des protons de recul des collisions élastiques entre les neutrons et l’hydrogène dans le polyéthylène. Des réactions nucléaires entre les neutrons et le silicium produisent des particules-α. Une étude de l’efficacité de reconnaissance des traces des protons et des particules-α dans le détecteur Medipix2-USB a été faite en fonction de l’énergie cinétique incidente et de l’angle d’incidence. L’efficacité de détection des neutrons rapides a été évaluée à deux seuils d’énergie (8 keV et 230 keV) dans les détecteurs ATLAS-MPX. L’efficacité de détection des neutrons rapides dans la région du détecteur couverte avec le polyéthylène augmente en fonction de l’énergie des neutrons : (0.0346 ± 0.0004) %, (0.0862 ± 0.0018) % et (0.1044 ± 0.0026) % pour des neutrons rapides de 2.13 MeV, 4.08 MeV et 27 MeV respectivement. L’étude pour déterminer l’énergie des neutrons permet donc d’estimer le flux des neutrons quand le détecteur ATLAS-MPX est dans un champ de radiation inconnu comme c’est le cas dans le détecteur ATLAS au LHC.
Resumo:
Cette thèse est dédiée à l’étude des matériaux InMnP et GaMnP fabriqués par implantation ionique et recuit thermique. Plus précisément nous avons investigué la possibilité de former par implantation ionique des matériaux homogènes (alliages) de InMnP et GaMnP contenant de 1 à 5 % atomiques de Mn qui seraient en état ferromagnétique, pour des possibles applications dans la spintronique. Dans un premier chapitre introductif nous donnons les motivations de cette recherche et faisons une revue de la littérature sur ce sujet. Le deuxième chapitre décrit les principes de l’implantation ionique, qui est la technique utilisée pour la fabrication des échantillons. Les effets de l’énergie, fluence et direction du faisceau ionique sur le profil d’implantation et la formation des dommages seront mis en évidence. Aussi dans ce chapitre nous allons trouver des informations sur les substrats utilisés pour l’implantation. Les techniques expérimentales utilisées pour la caractérisation structurale, chimique et magnétique des échantillons, ainsi que leurs limitations sont présentées dans le troisième chapitre. Quelques principes théoriques du magnétisme nécessaires pour la compréhension des mesures magnétiques se retrouvent dans le chapitre 4. Le cinquième chapitre est dédié à l’étude de la morphologie et des propriétés magnétiques des substrats utilisés pour implantation et le sixième chapitre, à l’étude des échantillons implantés au Mn sans avoir subi un recuit thermique. Notamment nous allons voir dans ce chapitre que l’implantation de Mn à plus que 1016 ions/cm2 amorphise la partie implantée du matériau et le Mn implanté se dispose en profondeur sur un profil gaussien. De point de vue magnétique les atomes implantés se trouvent dans un état paramagnétique entre 5 et 300 K ayant le spin 5/2. Dans le chapitre 7 nous présentons les propriétés des échantillons recuits à basses températures. Nous allons voir que dans ces échantillons la couche implantée est polycristalline et les atomes de Mn sont toujours dans un état paramagnétique. Dans les chapitres 8 et 9, qui sont les plus volumineux, nous présentons les résultats des mesures sur les échantillons recuits à hautes températures : il s’agit d’InP et du GaP implantés au Mn, dans le chapitre 8 et d’InP co-implanté au Mn et au P, dans le chapitre 9. D’abord, dans le chapitre 8 nous allons voir que le recuit à hautes températures mène à une recristallisation épitaxiale du InMnP et du GaMnP; aussi la majorité des atomes de Mn se déplacent vers la surface à cause d’un effet de ségrégation. Dans les régions de la surface, concentrés en Mn, les mesures XRD et TEM identifient la formation de MnP et d’In cristallin. Les mesures magnétiques identifient aussi la présence de MnP ferromagnétique. De plus dans ces mesures on trouve qu’environ 60 % du Mn implanté est en état paramagnétique avec la valeur du spin réduite par rapport à celle trouvée dans les échantillons non-recuits. Dans les échantillons InP co-implantés au Mn et au P la recristallisation est seulement partielle mais l’effet de ségrégation du Mn à la surface est beaucoup réduit. Dans ce cas plus que 50 % du Mn forme des particules MnP et le restant est en état paramagnétique au spin 5/2, dilué dans la matrice de l’InP. Finalement dans le dernier chapitre, 10, nous présentons les conclusions principales auxquels nous sommes arrivés et discutons les résultats et leurs implications.
Resumo:
Thèse réalisée en cotutelle avec l'Université Catholique de Louvain (Belgique)
Resumo:
Nous présenterons le procédé de fabrication, la caractérisation, ainsi qu’un modèle numérique permettant l’optimisation d’un nouveau dispositif permettant d’effectuer des mesures de nanocalorimétrie sur un échantillon de silicium monocristallin. Ce dernier possède entre autre des propriétés thermiques nous permettant d’effectuer des mesures à des températures supérieures à 900 C, avec une résolution meilleure que 16 C. Ceci nous a permis d’étudier la dynamique des défauts induits par implantation ionique dans le silicium monocristallin. Deux comportements différents sont observés dans la germination de la phase amorphe induite par implantation à 10 et 80 keV. Ces résultats ont été confrontés à des simulations Monte-Carlo basées sur le modèle des paires lacunesinterstitiels. La comparaison entre les simulations et les mesures expérimentales ont montré que ce modèle est incomplet car il ne reproduit qualitativement que certaines caractéristiques observées expérimentalement. Des mesures réalisées à partir de -110 C dans le silicium monocristallin et amorphisé implanté avec des ions légers, ont mis en évidence des différences claires entre la relaxation dans le silicium amorphe et le recuit des défauts dans le silicium monocristallin. Deux processus à des énergies d’activation de 0.48 et 0.6 eV ont été observés pour les implantations réalisées dans le silicium monocristallin tandis qu’un relâchement de chaleur uniforme ne révélant qu’un spectre continu d’énergie d’activation a été observé dans le silicium amorphe.