972 resultados para Saphenous vein


Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Polycythemia vera (PV) is a hemopoetic disorder. Apparently, although thrombosis accounts for the majority of morbidity, AION has not been associated with PV so far. PATIENT AND FINDINGS: A 63 y-old woman with PV was hospitalized because of acute liver failure. She also experienced bilateral painless loss of vision. Bilateral, pale optic disc swelling with flame-like hemorrhages, more pronounced in the right eye, constricted visual fields, and relative afferent papillary defect (RAPD) on the right side were present. Computer tomography scan revealed no signs of intraorbital pathology, elevated intracranial pressure or hemorrhages. CLINICAL COURSE: We interpreted the findings as AION associated with the hyperviscosity syndrome. Liver transplantation had to be carried out in the next days. Three weeks later, vision improved slightly, but RAPD persisted, and disc pallor developed in both eyes. The patient died two months later. DISCUSSION: Central retinal artery and vein occlusions have been described as complications of Essential thrombocythemia, but not of PV. We observed a rare case of bilateral neuropathy suggestive of AION. This condition has so far not been associated with PV.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

This report deals with a bentonite deposit recently developed, approximately seven miles northeast of Warm Springs, Montana. A group of claims have been staked on the deposit and are owned by the Lincoln Mining Company of Anaconda, Montana. The company also has several claims prospected for silver one mile from its present site of operations, but the silver prospects have failed to produce. The bentonite deposit was discovered incidentally during the course of other development work, and at present two adits have been driven into the side of a mountain, each crosscutting a vein-like mass of bentonite varying from two to three feet in width.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

To what extent is “software engineering” really “engineering” as this term is commonly understood? A hallmark of the products of the traditional engineering disciplines is trustworthiness based on dependability. But in his keynote presentation at ICSE 2006 Barry Boehm pointed out that individuals’, systems’, and peoples’ dependency on software is becoming increasingly critical, yet that dependability is generally not the top priority for software intensive system producers. Continuing in an uncharacteristic pessimistic vein, Professor Boehm said that this situation will likely continue until a major software-induced system catastrophe similar in impact to the 9/11 World Trade Center catastrophe stimulates action toward establishing accountability for software dependability. He predicts that it is highly likely that such a software-induced catastrophe will occur between now and 2025. It is widely understood that software, i.e., computer programs, are intrinsically different from traditionally engineered products, but in one aspect they are identical: the extent to which the well-being of individuals, organizations, and society in general increasingly depend on software. As wardens of the future through our mentoring of the next generation of software developers, we believe that it is our responsibility to at least address Professor Boehm’s predicted catastrophe. Traditional engineering has, and continually addresses its social responsibility through the evolution of the education, practice, and professional certification/licensing of professional engineers. To be included in the fraternity of professional engineers, software engineering must do the same. To get a rough idea of where software engineering currently stands on some of these issues we conducted two surveys. Our main survey was sent to software engineering academics in the U.S., Canada, and Australia. Among other items it sought detail information on their software engineering programs. Our auxiliary survey was sent to U.S. engineering institutions to get some idea about how software engineering programs compared with those in established engineering disciplines of Civil, Electrical, and Mechanical Engineering. Summaries of our findings can be found in the last two sections of our paper.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: beta(3)-Integrins are involved in platelet aggregation via alpha(IIb)beta(3) [glycoprotein (GP)IIb-GPIIIa], and in angiogenesis via endothelial alpha(V)beta(3). Cross-reactive ligands with antiaggregatory and proangiogenic effects, both desirable in peripheral vasculopathies, have not yet been described. OBJECTIVES: In vitro and in vivo characterization of antiaggregatory and proangiogenic effects of two recombinant human Fab fragments, with emphasis on beta(3)-integrins. METHODS: Recombinant Fab fragments were obtained by phage display technology. Specificity, affinity and IC(50) were determined by immunodot assays, enzyme-linked immunosorbent assay (ELISA), and Scatchard plot analysis, and by means of human umbilical vein endothelial cells (HUVECs). Functional analyses included ELISA for interaction with fibrinogen binding to GPIIb-GPIIIa, flow cytometry for measurement of activation parameters and competitive inhibition experiments, human platelet aggregometry, and proliferation, tube formation and the chorioallantoic membrane (CAM) assay for measurement of angiogenic effects. RESULTS: We observed specific and high-affinity binding to an intact GPIIb-GPIIIa receptor complex of two human Fab autoantibody fragments, with no platelet activation. Dose-dependent fibrinogen binding to GPIIb-GPIIIa and platelet aggregation were completely inhibited. One Fab fragment was competitively inhibited by abciximab and its murine analog monoclonal antibody (mAb) 7E3, whereas the other Fab fragment bound to cultured HUVECs, suggesting cross-reactivity with alpha(V)beta(3), and also demonstrated proangiogenic effects in tube formation and CAM assays. CONCLUSIONS: These Fab fragments are the first entirely human anti-GPIIb-GPIIIa Fab fragments with full antiaggregatory properties; furthermore, they do not activate platelets. The unique dual-specificity anti-beta(3)-integrin Fab fragment may represent a new tool for the study and management of peripheral arterial vasculopathies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVES: The C-Port System (Cardica, Inc, Redwood City, Calif) integrates in one tool all functions necessary to enable rapid automated distal coronary anastomoses. The goal of this prospective, nonrandomized, and multicenter study is to determine the safety and efficacy of this novel anastomotic system. METHODS: Five centers enrolled 133 patients awaiting elective coronary artery bypass grafting surgery. Outcome variables were intraoperative device performance, incidence of device-related adverse events, predischarge and 6-month angiographic graft patency, and 12-month clinical outcome. Independent core laboratories performed qualitative and quantitative angiographic and computed tomographic assessments. RESULTS: The C-Port was used to perform a vein-to-coronary anastomosis in 130 patients. Intraoperative conversion to a hand-sewn anastomosis was necessary in 11 patients because of inadequate target site preparation, inappropriate target vessel selection, or both. Inadequate blood flow related to poor runoff required conversion in 3 additional patients. Three patients died before discharge of causes unrelated to the device. At discharge, 113 patients had a C-Port implant in place, and 104 C-Port anastomoses were studied by means of angiography, resulting in 100 FitzGibbon A, 3 FitzGibbon B, and 1 FitzGibbon 0 classifications. At 6 months, one additional patient died of a device-unrelated cause, and 98 patients were evaluated by means of angiography (n = 89). Overall patency (FitzGibbon A) was 92.1%. Three C-Port anastomoses were rated FitzGibbon B, and 4 were rated FitzGibbon 0. At 12 months, 107 (98.2%) of 109 alive patients were followed up, without any reports of device-related major adverse cardiac events. CONCLUSIONS: The C-Port System allows for a rapid, reliable, and compliant distal anastomosis and yields favorable 6-month angiographic and 12-month clinical results when compared with published studies.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND. The high rate of reperfusion injury in clinical lung transplantation mandates significant improvements in lung preservation. Innovations should be validated using standardized and low-cost experimental models. METHODS. The model introduced here is analyzed by comparing global lung function after varying ischemic times (2, 4, 8, 16, and 24 hours). A rat double-lung block is flush-perfused, and the main pulmonary artery and left atrium are connected to the left pulmonary artery and vein of a syngeneic recipient using a T-shaped stent. With pressure side ports and incorporated flow crystals, measurement of vascular resistance and graft oxygenation can be performed. The transplant is ventilated separately, and compliance and resistance are determined. RESULTS. The increase in the ischemic interval from 2 to 24 hours caused an increase in the alveolar arterial oxygen difference from 220 +/- 20 to 600 +/- 34 mm Hg, pulmonary vascular resistance from 198 +/- 76 to 638 +/- 212 mm Hg.mL-1.min-1, and resistance to airflow from 274 +/- 50 to 712 +/- 30 cm H2O/L H2O, and a decrease in pulmonary compliance from 0.4 +/- 0.05 to 0.12 +/- 0.06 mL/cm H2O. CONCLUSIONS. This in situ, syngeneic rat lung transplantation model offers an alternative to large animal models for verification of lung preservation solutions and for modification of donor or recipient treatment regimens.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The PAS-Port device (Cardica, Redwood City, CA) allows the rapid deployment of a clampless proximal anastomosis between a vein graft and the aorta. METHODS: Fifty-four patients awaiting elective coronary artery bypass graft surgery were enrolled. Outcome variables were intraoperative device performance, early and 6- month angiographic graft patency, and 12-month clinical follow-up. RESULTS: Sixty-three PAS-Port devices were deployed in 54 patients. Two deployments were unsuccessful. There were no reoperations for bleeding. Two patients died of causes unrelated to the device. Patency evaluation at discharge was performed by angiogram on 49 implants and computed tomography in 2 implants (86% follow-up). At discharge, all evaluated grafts were patent (100%) and rated Fitzgibbon A. At 6-month follow-up, there was no additional mortality; 47 implants (88% follow-up) were evaluated by angiography (Fitzgibbon O [n = 1], Fitzgibbon B [n = 1], and Fitzgibbon A [n = 45]) and 5 by computed tomography. All grafts but 1 were patent (98.1%). At 12 months, 2 additional patients died of causes unrelated to the PAS-Port implant. Forty-six of 50 alive patients (95.8%) were followed up without any reports of device-related major adverse cardiac events. CONCLUSIONS: Discharge (100%) and 6-month patency (98%) are excellent; patency and 12 months' clinical follow-up compares favorably with data from historical hand-sewn controls. The PAS-Port system safely allows the clampless creation of a proximal anastomosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: Currently, only anecdotal information exists on the presentation and outcome of coronary arterial injury after ablation procedures. METHODS AND RESULTS: Four patients who sustained coronary artery injury of a cohort of patients undergoing 4655 consecutive ablation procedures (0.09%) are described. The patients' mean age was 45+/-11 years, and 1.8+/-0.5 prior ablation attempts had been unsuccessful. Coronary injury occurred from epicardial ventricular tachycardia ablation in 2 patients (irrigated radiofrequency ablation in one and cryoablation in the other) and ablation within the middle cardiac vein with irrigated radiofrequency in 2 patients. All involved branches of the right coronary artery. Acute occlusion presenting with ST-segment elevation immediately after ablation was recognized during the procedure in 2 cases. Occlusion failed to respond to nitroglycerin or balloon dilation, and stenting was required in both cases. Acute myocardial infarction occurred 2 weeks after epicardial ablation as a result of occlusion of a right ventricular branch of the right coronary artery giving rise to the posterior descending coronary artery in 1 patient. A moderate asymptomatic stenosis was seen on angiography after epicardial cryoablation in 1 patient. All patients recovered and remained asymptomatic from the coronary injury and arrhythmias during 37+/-53 months of follow-up. CONCLUSIONS: Coronary arterial injury after ablation procedures is rare. It may present acutely or several weeks after an ablation procedure. Acute occlusion appears to require coronary stenting. Unanticipated anatomic variations can predispose to coronary injury.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Health-related quality of life (QoL) has been associated with several social and medical conditions in patients with deep vein thrombosis (DVT) and pulmonary embolism (PE). To the best of our knowledge, there is no study investigating the relationship of QoL with psychological variables in this patient population. We assumed as a hypothesis an association between heightened levels of fatigue and psychological distress, as well as decreased QoL in patients with an objectively diagnosed venous thromboembolic event. Study participants were 205 consecutively enrolled out-patients (47.4 years, 54.6% men) with DVT and/or PE. Approximately 10 days before blood collection for thrombophilia work-up, QoL, fatigue, and psychological distress were assessed using the Short Form Health Survey (SF-12), the Multidimensional Fatigue Symptom Inventory Short Form (MFSI-SF) as well as the Hospitality Anxiety and Depression scale (HADS). After controlling for demographic and medical factors, fatigue (p < 0.01) but not psychological distress (p>0.05) was negatively associated with physical QoL, explaining 11.0% of the variance. Fatigue (p < 0.001) and psychological distress (p < 0.001) were significant predictors of mental QoL, explaining an additional 36.2% and 3.6% of the variance. Further analyses revealed that all subscales of the HADS (e.g. anxiety and depression) and of the MFSI-SF (e.g. general fatigue, physical fatigue, emotional fatigue, mental fatigue and vigor) were significant predictors of mental QoL. MFSI-SF subscales also predicted physical QoL. The findings suggest that fatigue and psychological distress substantially predict QoL in patients with a previous venous thromboembolic event above and beyond demographic factors.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND/AIMS: Angiogenesis is a pathological hallmark of portal hypertension. Although VEGF is considered to be the most important proangiogenic factor in neoangiogenesis, this process requires the coordinated action of a variety of factors. Identification of novel molecules involved in angiogenesis is highly relevant, since they may represent potential new targets to suppress pathological neovascularization in angiogenesis-related diseases like portal hypertension. The apelin/APJ signaling pathway plays a crucial role in angiogenesis. Therefore, we determined whether the apelin system modulates angiogenesis-driven processes in portal hypertension. METHODS: Partial portal vein-ligated rats were treated with the APJ antagonist F13A for seven days. Splanchnic neovascularization and expression of angiogenesis mediators (Western blotting) was determined. Portosystemic collateral formation (microspheres), and hemodynamic parameters (flowmetry) were also assessed. RESULTS: Apelin and its receptor APJ were overexpressed in the splanchnic vasculature of portal hypertensive rats. F13A effectively decreased, by 52%, splanchnic neovascularization and expression of proangiogenic factors VEGF, PDGF and angiopoietin-2 in portal hypertensive rats. F13A also reduced, by 35%, the formation of portosystemic collateral vessels. CONCLUSIONS: This study provides the first experimental evidence showing that the apelin/APJ system contributes to portosystemic collateralization and splanchnic neovascularization in portal hypertensive rats, presenting a potential novel therapeutic target for portal hypertension.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: Compare changes in P-wave amplitude of the intra-atrial electrocardiogram (ECG) and its corresponding transesophageal echocardiography (TEE)-controlled position to verify the exact localization of a central venous catheter (CVC) tip. DESIGN: A prospective study. SETTING: University, single-institutional setting. PARTICIPANTS: Two hundred patients undergoing elective cardiac surgery. INTERVENTIONS: CVC placement via the right internal jugular vein with ECG control using the guidewire technique and TEE control in 4 different phases: phase 1: CVC placement with normalized P wave and measurement of distance from the crista terminalis to the CVC tip; phase 2: TEE-controlled placement of the CVC tip; parallel to the superior vena cava (SVC) and measurements of P-wave amplitude; phase 3: influence of head positioning on CVC migration; and phase 4: evaluation of positioning of the CVC postoperatively using a chest x-ray. MEASUREMENTS AND MAIN RESULTS: The CVC tip could only be visualized in 67 patients on TEE with a normalized P wave. In 198 patients with the CVC parallel to the SVC wall controlled by TEE (phase 2), an elevated P wave was observed. Different head movements led to no significant migration of the CVC (phase 3). On a postoperative chest-x-ray, the CVC position was correct in 87.6% (phase 4). CONCLUSION: The study suggests that the position of the CVC tip is located parallel to the SVC and 1.5 cm above the crista terminalis if the P wave starts to decrease during withdrawal of the catheter. The authors recommend that ECG control as per their study should be routinely used for placement of central venous catheters via the right internal jugular vein.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The role of pelvic lymph node dissection (PLND) in prostate cancer, in which patients and to what extent it should be performed, remains a controversial topic. Preoperative diagnostic methods are more or less unreliable for lymph node staging and PLND remains the most reliable and accurate method. PLND is indicated in all patients with a PSA value >10 ng/ml and in those with a PSA <10 ng/ml if the Gleason score is > or = 7. If PLND is performed then it should always include the tissue along the external iliac vein, in the obturator fossa and on either side of the internal iliac vessels, up to where the ureter crosses the common iliac vessels. In conjunction with RRP extended PLND may increase staging accuracy, influence decision making with respect to adjuvant therapy and possibly impact outcome.