969 resultados para STOCHASTIC CORRECTOR MODEL


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A murine skin abscess model was used to study the immune response to an acute infection with Bacteroides forsythus. BALB/c mice were given subcutaneous injections of either viable or heat-killed B. forsythus, while a third sham-immunized control group received phosphate-buffered saline. Weights and lesion sizes were measured. Blood was collected from the heart and specific antibodies to B. forsythus measured by an ELISA. Swabs taken from the lesions and also from pooled blood were cultured anaerobically for viable B. forsythus. Viable B. forsythus-induced lesions reached maximum size at day 7. B. forsythus cells were recovered from lesions up to day 4 although none were cultured from blood samples. Heat-killed bacteria induced much smaller lesions. Serum antibody levels increased during the 9-day study period, being significantly higher in mice injected with viable compared with heat-killed B. forsythus. Antibody levels in sham control mice were significantly lower than those seen in the other two groups. These results showed that a subcutaneous injection of viable cells of B. forsythus elicited a pronounced abscess formation and induce higher levels of specific antibodies compared with that produced by an injection of dead bacteria. This suggests that, as with other periodontopathic organisms, this mouse model can be used to study the immune response to B. forsythus.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Bond's method for ball mill scale-up only gives the mill power draw for a given duty. This method is incompatible with computer modelling and simulation techniques. It might not be applicable for the design of fine grinding ball mills and ball mills preceded by autogenous and semi-autogenous grinding mills. Model-based ball mill scale-up methods have not been validated using a wide range of full-scale circuit data. Their accuracy is therefore questionable. Some of these methods also need expensive pilot testing. A new ball mill scale-up procedure is developed which does not have these limitations. This procedure uses data from two laboratory tests to determine the parameters of a ball mill model. A set of scale-up criteria then scales-up these parameters. The procedure uses the scaled-up parameters to simulate the steady state performance of full-scale mill circuits. At the end of the simulation, the scale-up procedure gives the size distribution, the volumetric flowrate and the mass flowrate of all the streams in the circuit, and the mill power draw.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new ball mill scale-up procedure is developed which uses laboratory data to predict the performance of MI-scale ball mill circuits. This procedure contains two laboratory tests. These laboratory tests give the data for the determination of the parameters of a ball mill model. A set of scale-up criteria then scales-up these parameters. The procedure uses the scaled-up parameters to simulate the steady state performance of the full-scale mill circuit. At the end of the simulation, the scale-up procedure gives the size distribution, the volumetric flowrate and the mass flowrate of all the streams in the circuit, and the mill power draw. A worked example shows how the new ball mill scale-up procedure is executed. This worked example uses laboratory data to predict the performance of a full-scale re-grind mill circuit. This circuit consists of a ball mill in closed circuit with hydrocyclones. The MI-scale ball mill has a diameter (inside liners) of 1.85m. The scale-up procedure shows that the full-scale circuit produces a product (hydrocyclone overflow) that has an 80% passing size of 80 mum. The circuit has a recirculating load of 173%. The calculated power draw of the full-scale mill is 92kW (C) 2001 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A new ball mill scale-up procedure is developed. This procedure has been validated using seven sets of Ml-scale ball mil data. The largest ball mills in these data have diameters (inside liners) of 6.58m. The procedure can predict the 80% passing size of the circuit product to within +/-6% of the measured value, with a precision of +/-11% (one standard deviation); the re-circulating load to within +/-33% of the mass-balanced value (this error margin is within the uncertainty associated with the determination of the re-circulating load); and the mill power to within +/-5% of the measured value. This procedure is applicable for the design of ball mills which are preceded by autogenous (AG) mills, semi-autogenous (SAG) mills, crushers and flotation circuits. The new procedure is more precise and more accurate than Bond's method for ball mill scale-up. This procedure contains no efficiency correction which relates to the mill diameter. This suggests that, within the range of mill diameter studied, milling efficiency does not vary with mill diameter. This is in contrast with Bond's equation-Bond claimed that milling efficiency increases with mill diameter. (C) 2001 Elsevier Science Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this paper we study the n-fold multiplicative model involving Weibull distributions and examine some properties of the model. These include the shapes for the density and failure rate functions and the WPP plot. These allow one to decide if a given data set can be adequately modelled by the model. We also discuss the estimation of model parameters based on the WPP plot. (C) 2001 Elsevier Science Ltd. All rights reserved.