972 resultados para SOLID-PHASE SYNTHESIS


Relevância:

80.00% 80.00%

Publicador:

Resumo:

An analytical procedure for the separation and quantification of 20 amino acids in cachacas has been developed involving C18 solid phase cleanup, derivatization with o-phthalaldehyde/2-mercaptoethanol, and reverse phase liquid chromatography with fluorescence detection. The detection limit was between 0.0050 (Cys) and 0.25 (Ser) mg L-1, whereas the recovery index varies from 69.5 (Lys) to 100 (Tyr)%. Relative standard deviations vary from 1.39 (Trp) to 13.4 (Glu)% and from 3.08 (Glu) to 13.5 (His) for the repeatability and intermediate precision, respectively. From the quantitative profile of amino acids in 41 cachacas, 5 turns, and 12 whisky samples, the following order of amino acids in significant quantities is observed: Gly = Ser < Cys < Ile < His < Pro = Asp < Asn < Tyr for cachaca; Phe < Glu = Gln = Val = Ala < His = Gly Thr = Arg = Tyr < Asn Ser = Lys = Pro < Cys = Asp for rum; and Ala = Asn < Trp < Gln = His = Met = Ile = Cys < Thr < Asp Leu < Phe = Lys < Ser = Gly = Tyr = Val < Glu = Pro < Arg for whisky samples. (C) 2007 Elsevier Ltd. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Direct analysis, with minimal sample pretreatment, of antidepressant drugs, fluoxetine, imipramine, desipramine, amitriptyline, and nortriptyline in biofluids was developed with a total run time of 8 min. The setup consists of two HPLC pumps, injection valve, capillary RAM-ADS-C18 pre-column and a capillary analytical C 18 column connected by means of a six-port valve in backflush mode. Detection was performed with ESI-MS/MS and only 1 mu m of sample was injected. Validation was adequately carried out using FLU-d(5) as internal standard. Calibration curves were constructed under a linear range of 1-250 ng mL(-1) in plasma, being the limit of quantification (LOQ), determined as 1 ng mL(-1), for all the analytes. With the described approach it was possible to reach a quantified mass sensitivity of 0.3 pg for each analyte (equivalent to 1.1-1.3 fmol), translating to a lower sample consumption (in the order of 103 less sample than using conventional methods). (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A column switching LC method is presented for the analysis of fluoxetine (FLU) and norfluoxetine (NFLU) by direct injection of human plasma using a lab-made restricted access media (RAM) column. A RAM-BSA-octadecyl silica (C-18) column (40 min x 4.6 mm, 10 mu m) is evaluated in both backflush and foreflush elution modes and coupled with a C-18 lab-made (50 mm x 4.6 mm, 3 pm) analytical column in order to perform online sample preparation. Direct injection of 100 mu L, of plasma samples is possible with the developed approach. In addition, reduction of sample handling is obtained when compared with traditional liquid-liquid extraction (LLE) and SPE. The total analysis time is around 20 min. A LOQ of 15 ng/mL is achieved in a concentration range of 15-500 ng/mL, allowing the therapeutic drug monitoring of clinical samples. The precision values achieved are lower than 15% for all the evaluated points with adequate recovery and accuracy. Furthermore, no matrix interferences are found in the analysis and the proposed method shows to be an adequate alternative for analysis of FLU in plasma.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The influence of the sample matrix in the CC-electron-capture detection analysis of the pesticides dimethoate, diazinon, chlorothalonil.. parathion methyl and fenitrothion in fruits samples has been studied. Experiments have been carried out where the pesticide responses in standard solutions prepared in selected solvent were compared with their response when present in apple, mango, papaya, banana, pineapple and melon extracts. The presence of matrix effects (MEs) and their extent were shown to be simultaneously influenced by several factors (matrix concentration, matrix type, pesticide concentration, analytical range). Pronounced MEs were observed particularly for dimethoate and diazinon in all matrices tested; in lower concentrations, all pesticides presented significant ME. The other pesticides presented variable ME. Higher ME enhancement was detected at lower pesticide concentration levels of and/or at higher matrix concentration solutions. The ME detected for fenitrothion, in the analytical range evaluated, were dependent on matrix type. For each pesticide, solvent and matrix-matched calibrations were compared for all fruit samples, and it could be concluded that quantitation based on standard solutions prepared in blank matrix extract (matrix-matched calibration) should be used to compensate the MEs and to obtain more accurate results for the pesticides studied.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A new polymeric coating consisting of a dual-phase, polydimethylsiloxane (PDMS) and polypyrrole (PPY) was developed for the stir bar sorptive extraction (SBSE) of antidepressants (mirtazapine, citalopram, paroxetine, duloxetine, fluoxetine and sertraline) from plasma samples, followed by liquid chromatography analysis (SBSE/LC-UV). The extractions were based on both adsorption (PPY) and sorption (PDMS) mechanisms. SBSE variables, such as extraction time, temperature, pH of the matrix, and desorption time were optimized, in order to achieve suitable analytical sensitivity in a short time period. The PDMS/PPY coated stir bar showed high extraction efficiency (sensitivity and selectivity) toward the target analytes. The quantification limits (LOQ) of the SBSE/LC-UV method ranged from 20 ng mL(-1) to 50 ng mL(-1), and the linear range was from LOQ to 500 ng mL(-1), with a determination coefficient higher than 0.99. The inter-day precision of the SBSE/LC-UV method presented a variation coefficient lower than 15%. The efficiency of the SBSE/LC-UV method was proved by analysis of plasma samples from elderly depressed patients. (C) 2008 Elsevier B.V. All rights reserved.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A method for the determination of pesticide residues in water and sediment was developed using the QuEChERS method followed by gas chromatography - mass spectrometry. The method was validated in terms of accuracy, specificity, linearity, detection and quantification limits. The recovery percentages obtained for the pesticides in water at different concentrations ranged from 63 to 116%, with relative standard deviations below 12%. The corresponding results from the sediment ranged from 48 to 115% with relative standard deviations below 16%. The limits of detection for the pesticides in water and sediment were below 0.003 mg L(-1) and 0.02 mg kg(-1), respectively.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fluidisation characteristics at different surfaces of a work-piece of complex geometry are conducted in a fluidised bed at various conditions including fluidising number, bed temperature and fluidising medium. The quenching of the work-piece is performed experimentally. In particular, the major frequency and energy of the pressure fluctuations are measured as a function of either fluidising velocity or heat transfer position and the results are used to develop a mathematic model. A computational model is developed to simulate gas dynamics and heat transfer between the fluidised bed and the work-piece surface, as well as simulating the temperature within the work-piece. The predicted cooling curves are in good agreement with the experimental results. Based on the simulation results, the flow characteristics of the gas and the temperature of the dense gas-solid phase near the work-piece surface are analysed to understand the heat transfer mechanism in the fluidised bed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Article Outline
• Introduction
• Principles
• Reaction Kinetics and the Observed Signal
• Chemiluminescence versus Fluorescence Detection
• Selectivity
• Corrected Emission Spectra
• Gas-Phase Reactions
• Liquid-Phase Reactions
Solid-Phase Reactions
• Acknowledgements
• Further Reading


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Thermal analysis, impedance spectroscopy, NMR and Raman spectroscopy have been used to investigate the plastic crystal dimethylpyrrolidinium thiocyanate in order to gain further insight into the properties of organic ionic plastic crystals. This compound has a solid–solid phase transition at 82 °C, and melts at 122 °C. A step increase in conductivity of about one order of magnitude is observed at the phase transition, followed by a decrease in activation energy for conduction. A large entropy gain occurs at the II → I transition, and 1H NMR linewidth measurements together with second moment calculations showed that the dimethylpyrrolidinium cation goes from a static state, to full isotropic tumbling. Raman measurements confirm that the cation as well as the anion exhibit increased rotational mobility when entering phase I.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The structure and transport of N-propyl-N-methylpyrrolidinium tetrafluoroborate (P13BF4) has been investigated over a wide temperature range in consequence to exhibiting properties suitable for potential solid-state superionic electrolyte applications. Prior to melting, the organic salt, P13BF4, transforms into a plastic crystal phase. Intrinsic conductivity in this solid, phase I (45–65 °C), is comparable to that in the melt (~10−3 S cm−1). Ionic motion and transport properties were investigated by 1H and 11B nuclear magnetic resonance (NMR) spectroscopy. Pressure-induced plastic flow in this system may accommodate volume changes in device application and to this extent, X-ray diffraction (XRD) has been used. Scanning electron microscopy (SEM) revealed complex surface morphology and lattice imperfections associated with the strong orientational disorder of the plastic state.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Ambient temperature conductive plastic crystal phases of alkylmethylpyrrolidinium trifluoromethanesulfonyl amide (TFSA) salts are studied using positron annihilation lifetime spectroscopy (PALS) to examine the role of vacancy size and concentration in conductivity. The ethyl methylpyrrolidinium TFSA salt (P12 TFSA) has larger vacancies and a greater concentration of vacancies than the dimethylpyrrolidinium TFSA salt (P11 TFSA) over the temperature range investigated. The relative vacancy size and concentration vary with temperature and reflect the solid–solid transitions as measured by differential scanning calorimetry (DSC). P12 TFSA has greater conductivity than P11 TFSA and has furthermore been observed to exhibit slip planes at room temperature. P12 TFSA has greater entropy changes associated with solid–solid phase transitions below the melting point than P11 TFSA possibly indicating greater rotational freedom in P12 TFSA. These results support the notion that the diffusion, conduction, and plastic flow properties of the pyrrolidinium TFSA salts are derived from the lattice vacancies.