996 resultados para Resonant tunneling diode
Resumo:
The aim of this study was to evaluate the effects of the use of a high-power gallium-aluminum-arsenide diode laser (GaAlAs; 808 nm, 1 W, 20 s, 20 Hz, 10 J) alone or as adjunctive therapy to scaling and root planing in the treatment of induced periodontitis in rats. Periodontitis was induced by placing a ligature around the mandibular first molar of 60 rats. After 7 days, the ligature was removed and the animals were divided into four groups as follows: C (control), no periodontal treatment; SRP, scaling and root planing (SRP); DL, diode laser (DL) irradiation treatment; and SRP/DL, both SRP and DL irradiation treatment. Five animals from each group were euthanized at 7, 15, and 30 days posttreatment. The effectiveness of the treatments was evaluated in the furcation area using histopathological analysis, histometric analysis of alveolar bone loss (ABL), and immunohistochemical detection of tartrate-resistant acid phosphatase (TRAP), runt-related transcription factor 2 (RUNX2), and osteocalcin (OCN). DL, alone or in combination with adjunctive therapy to SRP in the treatment of experimental periodontitis, resulted in a decreased local inflammatory response. At 7-days posttreatment, the DL and SRP/DL groups had fewer TRAP-positive cells and more RUNX2-positive cells. There was greater OCN immunolabeling in the DL group than in the C and SRP groups at 15 days. There was less ABL in the DL and SRP/DL groups at 15 and 30 days. In conclusion, DL was effective in the treatment of ligature-induced periodontitis in rats, both when used alone and when used as adjunctive therapy to SRP.
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
The development of new electroluminescence polymers for specific colour tuning in Polymer Light Emitting Devices (PLEDs) is currently one of the most important fields for organic electronics. This work reports a synthesis of a new electroluminescent polymer and the concomitant test as PLED emissive layer. The polymer, synthesised from fluorene, is poly(9,9`-n-dihexil-2,7-fluorenodiilvinylene-alt-2,5thiophene) or PFT The luminescence shows large bands with maxima around 480 nm in absorption and 560 nm in emission. The device was made in a three layer structure, with PEDOT:PSS as hole transport layer, PFT as emissive layer and butyl-PBD as electron transport layer. The electroluminescence spectrum shows a strong band peaked at 540 nm. For an applied voltage of 12 Volt, the brightness at normal angle of viewing is near 10 cd/m(2) and the luminous efficiency is of 0.01 lm/W. A discussion about carrier transport and the electroluminescence properties is made.
Resumo:
We review the previous literature and our recent work on first-principles studies of Cu3Au(100) and (111) surfaces, with focus on the segregation of atomic species to the surface at pristine conditions and in the presence of oxygen. In particular, the combined use of experimental and theoretical tools to achieve chemical identification at an atomic level of the surface species is emphasized and discussed.
Resumo:
We study the effects of spin accumulation (inside reservoirs) on electronic transport with tunneling and reflections at the gates of a quantum dot. Within the stub model, the calculations focus on the current-current correlation function for the flux of electrons injected into the quantum dot. The linear response theory used allows us to obtain the noise power in the regime of thermal crossover as a function of parameters that reveal the spin polarization at the reservoirs. The calculation is performed employing diagrammatic integration within the universal groups (ensembles of Dyson) for a nonideal, nonequilibrium chaotic quantum dot. We show that changes in the spin distribution determine significant alterations in noise behavior at values of the tunneling rates close to zero, in the regime of strong reflection at the gates.
Resumo:
Dentin wall structural changes caused by 810-nm-diode laser irradiation can influence the sealing ability of endodontic sealers. The objective of this study was to evaluate the apical leakage of AH Plus and RealSeal resin-based sealers with and without prior diode laser irradiation. Fifty-two single-rooted mandibular premolars were prepared and divided into 4 groups, according to the endodontic sealer used and the use or non-use of laser irradiation. The protocol for laser irradiation was 2.5W, continuous wave in scanning mode, with 4 exposures per tooth. After sample preparation, apical leakage of 50% ammoniacal silver nitrate impregnation was analyzed. When the teeth were not exposed to irradiation, the Real Seal sealer achieved the highest scores, showing the least leakage, with significant differences at the 5% level (Kruskal-Wallis test, p = 0.0004), compared with AH Plus. When the teeth were exposed to the 810-nm-diode laser irradiation, the sealing ability of AH Plus sealer was improved (p = 0282). In the Real Seal groups, the intracanal laser irradiation did not interfere with the leakage index, showing similar results in the GRS and GRSd groups (p = 0.1009).
Resumo:
Temperature changes caused by laser irradiation can promote damage to the surrounding dental tissues. In this study, we evaluated the temperature changes of recently extracted human mandibular incisors during intracanal irradiation with an 810-nm diode laser at different settings. Fifty mandibular incisors were enlarged up to an apical size of ISO No. 40 file. After the final rinse with 17% ethylenediaminetetraacetic acid, 0.2% lauryl sodium sulfate biologic detergent, and sterile water, samples were irradiated with circular movements from apex to crown through five different settings of output power (1.5, 2.0, 2.5, 3.0, and 3.5 W) in continuous mode. The temperature changes were measured on both sides of the apical and middle root thirds using two thermopar devices. A temperature increase of 7 degrees C was considered acceptable as a safe threshold when applying the diode laser. Results: The results showed that only 3.5-W output power increased the outer surface temperature above the critical value. Conclusion: The recommended output power can be stipulated as equal to or less than 3 W to avoid overheating during diode laser irradiation on thin dentin walls. (c) 2012 Society of Photo-Optical Instrumentation Engineers (SPIE). [DOI: 10.1117/1.JBO.17.1.015006]
Resumo:
Objective: The aim of this study was to evaluate the microhardness of radicular dentin after treatment with 980-nm diode laser and different irrigant solutions. Background data: There are few reports of the consequences of diode laser irradiation emitted at 980 nm on the mechanical properties of dentin. Methods: Seventy-two single canal, human canines with complete root formation were randomly distributed among three groups (n = 24), according to the irrigant solution used in the biomechanical preparation: distilled water; 1% NaOCl; and, 1% NaOCl + 17% EDTA. These groups subsequently were divided into three subgroups (n = 8), according to the diode laser parameter: no irradiation (control); 1.5W/100 Hz; and 3.0 W/100 Hz. Laser was applied with helicoidal movements for 20 sec. Roots were sectioned in slices and the fragment corresponding to the middle third was submitted to the microhardness test (KHN) at depths of 30, 90, 150, and 300 mu m. Results: ANOVA and Tukey tests showed that the microhardness of the groups irradiated with 1.5 W/100 Hz (49.7 +/- 11.2) and 3.0W/100 Hz (50.6 +/- 11.9) were statistically similar to each other (p > 0.05) and different (p < 0.05) from the non-irradiated group (45.0 +/- 9.7). Higher microhardness values were obtained at 150 mu m (49.2 +/- 11.0) and 300 mu m (52.3 +/- 11.3) which were similar among themselves and different (p < 0.05) only at the depth of 30 mu m (44.4 +/- 10.5). No differences were found among the irrigant solutions (p > 0.05). Conclusions: The microhardness of the radicular dentin increased after irradiation with 980-nm diode laser.
Resumo:
Many of the discovered exoplanetary systems are involved inside mean-motion resonances. In this work we focus on the dynamics of the 3:1 mean-motion resonant planetary systems. Our main purpose is to understand the dynamics in the vicinity of the apsidal corotation resonance (ACR) which are stationary solutions of the resonant problem. We apply the semi-analytical method (Michtchenko et al., 2006) to construct the averaged three-body Hamiltonian of a planetary system near a 3:1 resonance. Then we obtain the families of ACR, composed of symmetric and asymmetric solutions. Using the symmetric stable solutions we observe the law of structures (Ferraz-Mello,1988), for different mass ratio of the planets. We also study the evolution of the frequencies of σ1, resonant angle, and Δω, the secular angle. The resonant domains outside the immediate vicinity of ACR are studied using dynamical maps techniques. We compared the results obtained to planetary systems near a 3:1 MMR, namely 55 Cnc b-c, HD 60532 b-c and Kepler 20 b-c.
Resumo:
Several narrow alpha resonant 16O states were detected through the 12C(6Li,d) reaction, in the range of 12 to 17 MeV of excitation energy. The reaction was measured at a bombarding energy of 25.5 MeV employing the São Paulo Pelletron-Enge-Spectrograph facility and the nuclear emulsion technique. Experimental angular distributions associated with four natural parity quasi-bound states ncar the 4α threshold are presented and compared to DWBA predictions.
Resumo:
Resonant states are multiply excited states in atoms and ions that have enough energy to decay by emitting an electron. The ability to emit an electron and the strong electron correlation (which is extra strong in negative ions) makes these states both interesting and challenging from a theoretical point of view. The main contribution in this thesis is a method, which combines the use of B splines and complex rotation, to solve the three-electron Schrödinger equation treating all three electrons equally. It is used to calculate doubly excited and triply excited states of 4S symmetry with even parity in He-. For the doubly excited states there are experimental and theoretical data to compare with. For the triply excited states there is only theoretical data available and only for one of the resonances. The agreement is in general good. For the triply excited state there is a significant and interesting difference in the width between our calculation and another method. A cause for this deviation is suggested. The method is also used to find a resonant state of 4S symmetry with odd parity in H2-. This state, in this extremely negative system, has been predicted by two earlier calculations but is highly controversial. Several other studies presented here focus on two-electron systems. In one, the effect of the splitting of the degenerate H(n=2) thresholds in H-, on the resonant states converging to this threshold, is studied. If a completely degenerate threshold is assumed an infinite series of states is expected to converge to the threshold. Here states of 1P symmetry and odd parity are examined, and it is found that the relativistic and radiative splitting of the threshold causes the series to end after only three resonant states. Since the independent particle model completely fails for doubly excited states, several schemes of alternative quantum numbers have been suggested. We investigate the so called DESB (Doubly Excited Symmetry Basis) quantum numbers in several calculations. For the doubly excited states of He- mentioned above we investigate one resonance and find that it cannot be assigned DESB quantum numbers unambiguously. We also investigate these quantum numbers for states of 1S even parity in He. We find two types of mixing of DESB states in the doubly excited states calculated. We also show that the amount of mixing of DESB quantum numbers can be inferred from the value of the cosine of the inter-electronic angle. In a study on Li- the calculated cosine values are used to identify doubly excited states measured in a photodetachment experiment. In particular a resonant state that violates a propensity rule is found.
Resumo:
Resonante Laserionisations-Massenspektrometrie an Gadolinium zur Isotopenhäufigkeitsanalyse mit geringsten Mengen Die selektive Spuren- und Ultraspurenanalyse des Erdalkalielements Gadolinium eröffnet eine Vielzahl von Anwendungen in der Biomedizin und Kosmochemie. Zum Erreichen der hohen Anforderungen bezüglich Isotopen- und Isobarenselektivität von S>10^7 sowie Gesamteffizienz von e>10^-6 wurde der Einsatz der resonanten Laserionisations-Massenspektrometrie untersucht. Dazu erfolgte die Weiterentwicklung und Anpassung des existierenden Diodenlaser-Quadrupolmassenspektrometersystems. Durch Ionenflugbahn-Simulationsrechnungen wurde für das Quadrupol-Massenspektrometer die erreichbare Nachbarmassenunterdrückung und Transmission in Abhängigkeit von der Auflösung theoretisch vorhergesagt. Die Werte wurden experimentell bestätigt. Aus der beobachteten Peakstruktur erfolgte die Ableitung einer Methode zur Bestimmung der Energieunschärfe des eingesetzten Ionisationsprozesses. Zum Auffinden eines effizienten dreifach resonanten Anregungsschemas wurden die Isotopieverschiebungen und Hyperfeinstrukturen aller stabilen Gadoliniumisotope in zahlreichen Übergängen für die einfach, zweifach und dreifach resonante Ionisation präzise vermessen. Das aufgenommene Spektrum autoionisierender Resonanzen zeigte etwa 150 bislang unbekannter Zustände mit Resonanzüberhöhungen von bis zu fünf Größenordnungen im Ionisationswirkungsquerschnitt. Die entwickelte Methode der Hyperfeinzustandsselektion ermöglichte die Bestimmung der Drehimpulsquantenzahl J der autoionisierenden Resonanzen. Die analytische Charakterisierung der dreistufig resonanten Ionisation von Gadolinium ergab eine Isotopen- und Isobarenselektivität von S(Isotop)>10^12 und S(Isobar)>10^7. Die mit dem Diodenlasersystem erreichte Nachweiseffizienz von e=1-3x10^-6 mit einer untergrundlimitierten Nachweisgrenze von wenigen 10^9 Atomen Gd-158 erlaubte erste Demonstrationsmessungen an medizinischen Gewebeproben.
Resumo:
Die resonante Laserionisation hat sich als ein universales Verfahren für eine Vielzahl von Anwendungen etabliert, die eine selektive Ionisation bei hoher Effizienz erfordern. Hierzu wurden zwei Lasersysteme mit unterschiedlichen Zielsetzungen und Schwerpunkten entwickelt und in dieser Arbeit angewendet. Im ersten Teil der Arbeit wird die Entwicklung der hochauflösenden Resonanzionisations-Massenspektrometrie zum Ultraspurennachweis von 41Ca vorgestellt. Hierzu wurden drei kontinuierliche Diodenlaser mit einem Quadrupolmassenspektrometer kombiniert. Bei einer Nachweiseffizienz von 1 × 10^−5 konnte eine Nachweisgrenze von 2 × 10^-13 41Ca/totCa erreicht werden. Das in den Routinebetrieb überführte Meßverfahren ermöglichte die Teilnahme an einem interdisziplinären Netzwerk zur Osteoporose-Forschung. In Vergleichsmessungen der Resonanzionisations-Massenspektrometrie mit allen derzeit existierenden Meßverfahren zum 41Ca-Ultraspurennachweis konnte eine sehr gute Übereinstimmung erzielt werden. Der zweite Teil der Arbeit beinhaltet die Adaption eines durchstimmbaren, hochrepetierenden Titan:Saphir-Lasersystem für den Einsatz an Laserionenquellen zur selektiven Erzeugung radioaktiver Ionenstrahlen. Das entwickelte Lasersystem ermöglicht eine effiziente, resonante Anregung des Großteils der Elemente im Periodensystem. Hierzu wurde eine kombinierte Frequenzverdopplungs- und Frequenzverdreifachungseinheit zur Erzeugung höherer Harmonischer aufgebaut. Die Anwendbarkeit eines solchen reinen Festkörper-Lasersystems wurde in zahlreichen off-line Testmessungen sowohl in Mainz als auch an den ISOL Einrichtungen am TRIUMF und ORNL gezeigt und führte zum ersten on-line Einsatz am TRIUMF.