974 resultados para RETINAL NERVE FIBER LAYER


Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study reports on changes in the number of somatostatin-like immunoreactive (SOM-LI) endocrine cells in the porcine descending colon, caused by chemically driven inflammation, axotomy and proliferative enteropathy (PE). The distribution pattern of SOM-LI endocrine cells has been studied using the routine single-labelling immunofluorescence technique. Semi-quantitative evaluation of the number of the SOM-immunostained endocrine cells within the mucosal layer of the porcine descending colon has been based on counting of all endocrine cells immunoreactive to SOM per unit area (0,1 mm²). Under physiological conditions the number of SOM-LI endocrine cells has been shown to constitute 3,30±0,22. All applied pathological processes resulted in changes in the SOM-like immunoreactivity, which varied in particular processes studied. The number of SOM-LI endocrine cells increased to 6,28±0,31 and 4,43±0,35 during chemically driven inflammation and proliferative enteropathy, respectively, and decreased to 1,17%±0,16 after axotomy. The obtained results suggest that SOM-LI endocrine cells may participate in various pathological states within porcine descending colon and their functions probably depend on the type of pathological factor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A recent (November 2010) outbreak of infectious laryngotracheitis (ILT) in a multi-age laying hen facility in Minas Gerais state, Brazil, is described. Previous ILT outbreak in laying hens was only notified in São Paulo state, Brazil, in 2002. In the outbreak described here, the affected population was approximately eight million hens, with flock sizes ranging from 100,000 to 2,900,000 chickens. The average mortality ranged from 1 to 6%, and morbidity was around 90% (most of the twenty seven farms of the area were positive for ILT virus). Three multi-age laying farms from one company were selected for this report. Clinical signs included prostration, dyspnea, conjunctivitis, occasional swelling of the paranasal sinuses and bloody mucous nasal discharge. Severely affected chickens presented with dyspnea, gasping and became cyanotic before death. At necropsy, these chickens had fibrinous exudate blocking the larynx and the lumen of cranial part of the trachea. In addition, conjunctivitis with intense hyperemia, edema and sinuses with caseous exudate were present. On histopathology, there were marked necrosis and desquamation of respiratory ephitelium and conjunctiva with numerous syncytial cells formation and fibrinous exudate. Moderate to marked non suppurative (especially lymphocytes and plasma cells) infiltration in the lamina propria also was observed. Sixteen out of 20 examined chickens, eosinophilic intranuclear inclusion bodies were observed in the syncytial cells. The DNA extracted from larynx and trachea produced positive PCR results for ILT virus (ILTV) DNA using formalin-fixed, paraffin embedded (FFPE) samples. Amplicons from a small region of ICP4 gene were submitted to sequencing and showed 100% identity with ILTV EU104910.1 (USA strain), 99% with ILTV JN596963.1 (Australian strain) and 91% with ILTV JN580316.1 (Gallid herpesvirus 1 CEO vaccine strain) and JN580315.1 (Gallid herpesvirus 1 TCO vaccine strain).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Samples of ten penises of Mediterranean buffaloes and ten penises of Red Sindhi cattle were used. The thickness of the tunica albuginea (TA), distribution of smooth muscle cells (SMC) and volume density (Vv) of elastic system fibers in TA, corpus cavernosum (CC) and corpus spongiosum (CS) were evaluated. The Vv of elastic system fibers in buffalo and bovine penis was respectively 4.07% ±0.88% and 3.36% ±1.21% in TA; 17.32% ±2.21% and 13.14% ±1.27% (CC), 26.58% ±4.31% and 31.36% ±3.67% (CS). The CC of buffalo presented higher Vv of elastic fibers than bovine, while in the CS the Vv of elastic fibers in buffaloes was smaller than in cattle. The TA thickness showed a significant difference among the species studied. The arrangement of SMC in the bovine penises and in the water buffalo suggests that this pattern is common to animals that have fibroelastic penises.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Mass-produced paper electronics (large area organic printed electronics on paper-based substrates, “throw-away electronics”) has the potential to introduce the use of flexible electronic applications in everyday life. While paper manufacturing and printing have a long history, they were not developed with electronic applications in mind. Modifications to paper substrates and printing processes are required in order to obtain working electronic devices. This should be done while maintaining the high throughput of conventional printing techniques and the low cost and recyclability of paper. An understanding of the interactions between the functional materials, the printing process and the substrate are required for successful manufacturing of advanced devices on paper. Based on the understanding, a recyclable, multilayer-coated paper-based substrate that combines adequate barrier and printability properties for printed electronics and sensor applications was developed in this work. In this multilayer structure, a thin top-coating consisting of mineral pigments is coated on top of a dispersion-coated barrier layer. The top-coating provides well-controlled sorption properties through controlled thickness and porosity, thus enabling optimizing the printability of functional materials. The penetration of ink solvents and functional materials stops at the barrier layer, which not only improves the performance of the functional material but also eliminates potential fiber swelling and de-bonding that can occur when the solvents are allowed to penetrate into the base paper. The multi-layer coated paper under consideration in the current work consists of a pre-coating and a smoothing layer on which the barrier layer is deposited. Coated fine paper may also be used directly as basepaper, ensuring a smooth base for the barrier layer. The top layer is thin and smooth consisting of mineral pigments such as kaolin, precipitated calcium carbonate, silica or blends of these. All the materials in the coating structure have been chosen in order to maintain the recyclability and sustainability of the substrate. The substrate can be coated in steps, sequentially layer by layer, which requires detailed understanding and tuning of the wetting properties and topography of the barrier layer versus the surface tension of the top-coating. A cost competitive method for industrial scale production is the curtain coating technique allowing extremely thin top-coatings to be applied simultaneously with a closed and sealed barrier layer. The understanding of the interactions between functional materials formulated and applied on paper as inks, makes it possible to create a paper-based substrate that can be used to manufacture printed electronics-based devices and sensors on paper. The multitude of functional materials and their complex interactions make it challenging to draw general conclusions in this topic area. Inevitably, the results become partially specific to the device chosen and the materials needed in its manufacturing. Based on the results, it is clear that for inks based on dissolved or small size functional materials, a barrier layer is beneficial and ensures the functionality of the printed material in a device. The required active barrier life time depends on the solvents or analytes used and their volatility. High aspect ratio mineral pigments, which create tortuous pathways and physical barriers within the barrier layer limit the penetration of solvents used in functional inks. The surface pore volume and pore size can be optimized for a given printing process and ink through a choice of pigment type and coating layer thickness. However, when manufacturing multilayer functional devices, such as transistors, which consist of several printed layers, compromises have to be made. E.g., while a thick and porous top-coating is preferable for printing of source and drain electrodes with a silver particle ink, a thinner and less absorbing surface is required to form a functional semiconducting layer. With the multilayer coating structure concept developed in this work, it was possible to make the paper substrate suitable for printed functionality. The possibility of printing functional devices, such as transistors, sensors and pixels in a roll-to-roll process on paper is demonstrated which may enable introducing paper for use in disposable “onetime use” or “throwaway” electronics and sensors, such as lab-on-strip devices for various analyses, consumer packages equipped with product quality sensors or remote tracking devices.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Cranial bone reconstructions are necessary for correcting large skull bone defects due to trauma, tumors, infections and craniotomies. Traditional synthetic implant materials include solid or mesh titanium, various plastics and ceramics. Recently, biostable glass-fiber reinforced composites (FRC), which are based on bifunctional methacrylate resin, were introduced as novel implant solution. FRCs were originally developed and clinically used in dental applications. As a result of further in vitro and in vivo testing, these composites were also approved for clinical use in cranial surgery. To date, reconstructions of large bone defects were performed in 35 patients. This thesis is dedicated to the development of a novel FRC-based implant for cranial reconstructions. The proposed multi-component implant consists of three main parts: (i) porous FRC structure; (ii) bioactive glass granules embedded between FRC layers and (iii) a silver-polysaccharide nanocomposite coating. The porosity of the FRC structure should allow bone ingrowth. Bioactive glass as an osteopromotive material is expected to stimulate the formation of new bone. The polysaccharide coating is expected to prevent bacterial colonization of the implant. The FRC implants developed in this study are based on the porous network of randomly-oriented E-glass fibers bound together by non-resorbable photopolymerizable methacrylate resin. These structures had a total porosity of 10–70 volume %, of which > 70% were open pores. The pore sizes > 100 μm were in the biologically-relevant range (50-400 μm), which is essential for vascularization and bone ingrowth. Bone ingrowth into these structures was simulated by imbedding of porous FRC specimens in gypsum. Results of push-out tests indicated the increase in the shear strength and fracture toughness of the interface with the increase in the total porosity of FRC specimens. The osteopromotive effect of bioactive glass is based on its dissolution in the physiological environment. Here, calcium and phosphate ions, released from the glass, precipitated on the glass surface and its proximity (the FRC) and formed bone-like apatite. The biomineralization of the FRC structure, due to the bioactive glass reactions, was studied in Simulated Body Fluid (SBF) in static and dynamic conditions. An antimicrobial, non-cytotoxic polysaccharide coating, containing silver nanoparticles, was obtained through strong electrostatic interactions with the surface of FRC. In in vitro conditions the lactose-modified chitosan (chitlac) coating showed no signs of degradation within seven days of exposure to lysozyme or one day to hydrogen peroxide (H2O2). The antimicrobial efficacy of the coating was tested against Staphylococcus aureus and Pseudomonas aeruginosa. The contact-active coating had an excellent short time antimicrobial effect. The coating neither affected the initial adhesion of microorganisms to the implant surface nor the biofilm formation after 24 h and 72 h of incubation. Silver ions released to the aqueous environment led to a reduction of bacterial growth in the culture medium.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Abstract: In this retrospective study was determined the frequency of canine skin peripheral nerve sheath tumors (PNST) in cases diagnosed by the Setor de Patologia Veterinária of the Universidade Federal do Rio Grande do Sul (SPV-UFRGS), Brazil, between the years 2000 and 2012. The canine profiles, as well as histological, immunohistochemical and prognostic aspects of the tumors were based on 70 samples, comprising 40 females, 29 males and one unspecified sample. Between 2000 and 2012, 2,984 skin tumors of dogs were diagnosed in the SPV-UFRGS, totaling 2.34% of skin neoplasms in dogs. Animals that comprised the largest amount of samples (43%) were those with no breed (SRD), followed by German Shepherds (10%). Females were more affected than males (40/70 - 57% and 29/70 - 41% respectively). Skin PNST of this research showed predominant localization on the limbs (40% in the forelimbs and 29% in the hindlimbs); affecting adult dogs, mostly aged between 8 and 11 years (54%). The samples were routinely processed for hematoxylin and eosin, and were also evaluated by toluidine blue and Masson's trichrome staining, and immunohistochemistry (IHC) anti-vimentin, -S-100, -GFAP, -actin, von Willebrand factor and neurofilament. Anisocytosis and anisokaryosis, mitotic index, intratumoral necrosis, invasion of adjacent tissues, tumor location, local recurrence and metastasis were related to the diagnosis of benign (49/70) or malignant tumor (21/70). The Antoni A histological pattern was observed more frequently in benign tumors. The immunohistochemistry helped to diagnose PNST, and anti-vimentin and anti-protein S-100 showed the highest rates of immunostaining. Throughout statistical analysis of animals with tumor recurrence, it was found that the chance of an animal with a malignant peripheral nerve sheath tumor to develop recurrence is 4.61 times higher than in an animal that had a benign tumor.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The classical treatment of rough wall turbulent boundary layers consists in determining the effect the roughness has on the mean velocity profile. This effect is usually described in terms of the roughness function delta U+. The general implication is that different roughness geometries with the same delta U+ will have similar turbulence characteristics, at least at a sufficient distance from the roughness elements. Measurements over two different surface geometries (a mesh roughness and spanwise circular rods regularly spaced in the streamwise direction) with nominally the same delta U+ indicate significant differences in the Reynolds stresses, especially those involving the wall-normal velocity fluctuation, over the outer region. The differences are such that the Reynolds stress anisotropy is smaller over the mesh roughness than the rod roughness. The Reynolds stress anisotropy is largest for a smooth wall. The small-scale anisotropy and interniittency exhibit much smaller differences when the Taylor microscale Reynolds number and the Kolmogorov-normalized mean shear are nominally the same. There is nonetheless evidence that the small-scale structure over the three-dimensional mesh roughness conforms more closely with isotropy than that over the rod-roughened and smooth walls.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A theory for the description of turbulent boundary layer flows over surfaces with a sudden change in roughness is considered. The theory resorts to the concept of displacement in origin to specify a wall function boundary condition for a kappa-epsilon model. An approximate algebraic expression for the displacement in origin is obtained from the experimental data by using the chart method of Perry and Joubert(J.F.M., vol. 17, pp. 193-122, 1963). This expression is subsequently included in the near wall logarithmic velocity profile, which is then adopted as a boundary condition for a kappa-epsilon modelling of the external flow. The results are compared with the lower atmospheric observations made by Bradley(Q. J. Roy. Meteo. Soc., vol. 94, pp. 361-379, 1968) as well as with velocity profiles extracted from a set of wind tunnel experiments carried out by Avelino et al.( 7th ENCIT, 1998). The measurements are found to be in good agreement with the theoretical computations. The skin-friction coefficient was calculated according to the chart method of Perry and Joubert(J.F.M., vol. 17, pp. 193-122, 1963) and to a balance of the integral momentum equation. In particular, the growth of the internal boundary layer thickness obtained from the numerical simulation is compared with predictions of the experimental data calculated by two methods, the "knee" point method and the "merge" point method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Non-linear functional representation of the aerodynamic response provides a convenient mathematical model for motion-induced unsteady transonic aerodynamic loads response, that accounts for both complex non-linearities and time-history effects. A recent development, based on functional approximation theory, has established a novel functional form; namely, the multi-layer functional. For a large class of non-linear dynamic systems, such multi-layer functional representations can be realised via finite impulse response (FIR) neural networks. Identification of an appropriate FIR neural network model is facilitated by means of a supervised training process in which a limited sample of system input-output data sets is presented to the temporal neural network. The present work describes a procedure for the systematic identification of parameterised neural network models of motion-induced unsteady transonic aerodynamic loads response. The training process is based on a conventional genetic algorithm to optimise the network architecture, combined with a simplified random search algorithm to update weight and bias values. Application of the scheme to representative transonic aerodynamic loads response data for a bidimensional airfoil executing finite-amplitude motion in transonic flow is used to demonstrate the feasibility of the approach. The approach is shown to furnish a satisfactory generalisation property to different motion histories over a range of Mach numbers in the transonic regime.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work shows how thick boundary layers can be produced in a short wind tunnel with a view to simulate atmospheric flows. Several types of thickening devices are analysed. The experimental assessment of the devices was conducted by considering integral properties of the flow and the spectra: skin-friction, mean velocity profiles in inner and outer co-ordinates and longitudinal turbulence. Designs based on screens, elliptic wedge generators, and cylindrical rod generators are analysed. The paper describes in detail the experimental arrangement, including the features of the wind tunnel and of the instrumentation. The results are compared with experimental data published by other authors and with naturally developed flows.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pappersindustrin står inför många utmaningar och bör uppfylla krav som ställs av t.ex. marknadstrender och slutanvändare. Snabbare och effektivare processer ställer även större krav på pappersbanans mekaniska egenskaper. Avbrott i produktionen sker inte enbart pga. låg styrka utan orsaken kan även vara en för låg spänning i pappersbanan. De flesta problemen sker vid våtpressen och/eller i början av torkpartiet då papprets torrhalt är 30-70 %. Spänningen hålls inte konstant efter töjning, utan sjunker pga. papprets relaxering, som till största delen sker då pappret flyttas från pressen till torkpartiet. Ur forskningssynvinkel öppnar en smidigt fungerande verksamhet med potentiella energibesparingar upp möjligheterna för förbättring av befintliga processer. I detta arbete undersöktes hur olika faktorer inverkar på fibernätverkets avvattning, initiala våtstyrka och relaxering samt också på slutproduktens mekaniska egenskaper och ytegenskaper. I första delen ändrades processvattnets egenskaper, såsom pH, konduktivitet och ytspänning. Ytspänningen varierades genom tillsatts av ett nonjoniskt ytaktivt ämne, s.k. surfaktant. Fiberegenskaperna modifierades också. Fibern maldes antingen genom en mild eller genom en hård process. Effekten av finmaterial undersöktes genom att tillsätta finmaterial till den ursprungliga massan eller genom att avlägsna finmaterialet från den malda massan. I den sista delen användes en hemicellulosa, som finns i stora mängder i gran, som tillsatsmedel. Förutom naturliga galaktoglukomannaner (GGM), tillverkades också en katjoniserad, en karboximetylerad samt en iminerad, amfifil GGM. Dessa användes i pappersmassa eller sprayades på ytan av ett nybildat ark. Resultaten, som erhölls i denna avhandling, bildar en värdefull kunskapsbas, som kan användas för kontroll och reglering av pappersmaskinens körbarhet och papperskvalitet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fiber-reinforced composites (FRCs) are a new group of non-metallic biomaterials showing a growing popularity in many dental and medical applications. As an oral implant material, FRC is biocompatible in bone tissue environment. Soft tissue integration to FRC polymer material is unclear. This series of in vitro studies aimed at evaluating unidirectional E-glass FRC polymer in terms of mechanical, chemical, and biological properties in an attempt to develop a new non-metallic oral implant abutment alternative. Two different types of substrates were investigated: (a) Plain polymer (BisGMA 50%–TEGDMA 50%) and (b) Unidirectional FRC. The mechanical behavior of high fiber-density FRCs was assessed using a three-point bending test. Surface characterization was performed using scanning electron and spinning disk confocal microscopes. The surface wettability/energy was determined using sessile drop method. The blood response, including blood-clotting ability and platelet morphology was evaluated. Human gingival fibroblast cell responses - adhesion kinetics, adhesion strength, and proliferation activity - were studied in cell culture environment using routine test conditions. A novel tissue culture method was developed and used to evaluate porcine gingival tissue graft attachment and growth on the experimental composite implants. The analysis of the mechanical properties showed that there is a direct proportionality in the relationship between E-glass fiber volume fraction and toughness, modulus of elasticity, and load bearing capacity; however, flexural strength did not show significant improvement when high fiber-density FRC is used. FRCs showed moderate hydrophilic properties owing to the presence of exposed glass fibers on the polymer surface. Blood-clotting time was shorter on FRC substrates than on plain polymer. The FRC substrates also showed higher platelet activation state than plain polymer substrates. Fibroblast cell adhesion strength and proliferation rate were highly pronounced on FRCs. A tissue culture study revealed that gingival epithelium and connective tissue established an immediate close contact with both plain polymer and FRC implants. However, FRC seemed to guide epithelial migration outwards from the tissue/implant interface. Due to the anisotropic and hydrophilic nature of FRC, it can be concluded that this material enhances biological events related with soft tissue integration on oral implant surface.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this investigation was to evaluate the possibility to enhance certain qualities of facial prostheses. Polymethyl methacrylate is still being used as base mate¬rial or clip carrier material, but it is hard and heavy, and debonding of the silicone from the acrylic base material is a frequent problem. This thesis aims to evaluate the use of fiber-reinforced composite (FRC) as framework material for maxillofacial silicone prostheses. FRC has been used as reinforcement in removable and fixed partial dentures since the 1990s. This material is lightweight and can be fabricated to compress the margins of the prosthesis slightly, to keep it tightly against the skin during jaw movements and facial expressions. Additionally, the use of a thermochromic pigment, colorless in room temperature and red in a cold environment, was studied in order to evaluate the possibility of using this color changing pigment in facial prostheses to mimic the color change of facial skin in cold weather. The tensile bond strength between pre-impregnated, unidirectional FRC and maxillofacial silicone elastomer was studied. Three different bonding agents or primers were compared. Bond strength was improved by one of the primers and by roughening the surface. The effect of a skin compressing glass fiber-reinforced composite framework on facial skin blood flow was studied by using a face mask, constructed with a compression pad corresponding to the outer margin of a glass fiber-reinforced framework beam of a facial prosthesis. The skin blood flow of ten healthy volunteers, aged 23-25 years, was measured during touch, light, and moderate compression of the skin, by using laser Doppler imaging technique. None of the compressions showed any marked effects on local skin blood flow. There were no significant differences between blood flow during compression and at baseline. Maxillofacial silicone elastomer was colored intrinsically with conventional color pigments: a control group containing only conventional pigments was compared to two test groups with 0.2 wt% and 0.6 wt% thermochromic pigment added. The color of the material was measured with a spectrophotometer in room temperature and after storage in a freezer. The color stability of the maxillofacial silicone elastomer colored with thermo¬chromic pigment was evaluated by artificial aging. The color dif¬ference of the L* (lightness) and a* values (redness), comparing color after the samples were stored at room temperature and in a freezer (-19°C), was statistically significant for both 0.2 wt% and 0.6 wt% thermo¬chromic pigment groups. The differences in the b* values (yellowness) were statistically significant for the 0.6 wt% group. Exposure to ultraviolet (UV) radiation led to visually noticeable and statistically signifi¬cant color changes (ΔE) in all color values in both test groups. The specimens containing thermochromic pigment were very sensitive to UV radiation. In conclusion, a framework of fiber-reinforced composite can successfully be bonded to maxillofacial silicone elastomer, and a framework beam, compressing the facial skin, did not remarkably alter the skin blood flow on healthy, young adults. The thermochromic pigment showed color change in maxillofacial silicone elastomer. However, artificial aging showed that it was too sensitive to UV radiation to be used, as such, in maxillofacial prostheses.