983 resultados para Pulse transformers
Resumo:
OBJECTIVE: Balloon-expandable stent valves require flow reduction during implantation (rapid pacing). The present study was designed to compare a self-expanding stent valve with annular fixation versus a balloon-expandable stent valve. METHODS: Implantation of a new self-expanding stent valve with annular fixation (Symetis, Lausanne, Switzerland) was assessed versus balloon-expandable stent valve, in a modified Dynatek Dalta pulse duplicator (sealed port access to the ventricle for transapical route simulation), interfaced with a computer for digital readout, carrying a 25 mm porcine aortic valve. The cardiovascular simulator was programmed to mimic an elderly woman with aortic stenosis: 120/85 mmHg aortic pressure, 60 strokes/min (66.5 ml), 35% systole (2.8 l/min). RESULTS: A total of 450 cardiac cycles was analysed. Stepwise expansion of the self-expanding stent valve with annular fixation (balloon-expandable stent valve) resulted in systolic ventricular increase from 120 to 121 mmHg (126 to 830+/-76 mmHg)*, and left ventricular outflow obstruction with mean transvalvular gradient of 11+/-1.5 mmHg (366+/-202 mmHg)*, systolic aortic pressure dropped distal to the valve from 121 to 64.5+/-2 mmHg (123 to 55+/-30 mmHg) N.S., and output collapsed to 1.9+/-0.06 l/min (0.71+/-0.37 l/min* (before complete obstruction)). No valve migration occurred in either group. (*=p<0.05). CONCLUSIONS: Implantation of this new self-expanding stent valve with annular fixation has little impact on haemodynamics and has the potential for working heart implantation in vivo. Flow reduction (rapid pacing) is not necessary.
Resumo:
Purpose of the study: Basic life support (BLS) and automated externaldefibrillation (AED) represent important skills to be acquired duringpregraduate medical training. Since 3 years, our medical school hasintroduced a BLS-AED course (with certification) for all second yearmedical students. Few reports about quality and persistence over timeof BLS-AED learning are available to date in the medical literature.Comprehensive evaluation of students' acquired skills was performedat the end of the 2008 academic year, 6 month after certification.Materials and methods: The students (N = 142) were evaluated duringa 9 minutes «objective structured clinical examination» (OSCE) station.Out of a standardized scenario, they had to recognize a cardiac arrestsituation and start a resuscitation process. Their performance wererecorded on a PC using an Ambuman(TM) mannequin and the AmbuCPR software kit(TM) during a minimum of 8 cycles (30 compressions:2 ventilations each). BLS parameters were systematically checked. Nostudent-rater interactions were allowed during the whole evaluation.Results: Response of the victim was checked by 99% of the students(N = 140), 96% (N = 136) called for an ambulance and/or an AED. Openthe airway and check breathing were done by 96% (N = 137), 92% (N =132) gave 2 rescue breaths. Pulse was checked by 95% (N=135), 100%(N = 142) begun chest compression, 96% (N = 136) within 1 minute.Chest compression rate was 101 ± 18 per minute (mean ± SD), depthcompression 43 ± 8 mm, 97% (N = 138) respected a compressionventilationratio of 30:2.Conclusions: Quality of BLS skills acquisition is maintained during a6-month period after a BLS-AED certification. Main targets of 2005 AHAguidelines were well respected. This analysis represents one of thelargest evaluations of specific BLS teaching efficiency reported. Furtherfollow-up is needed to control the persistence of these skills during alonger time period and noteworthy at the end of the pregraduatemedical curriculum.
3D coronary vessel wall imaging utilizing a local inversion technique with spiral image acquisition.
Resumo:
Current 2D black blood coronary vessel wall imaging suffers from a relatively limited coverage of the coronary artery tree. Hence, a 3D approach facilitating more extensive coverage would be desirable. The straightforward combination of a 3D-acquisition technique together with a dual inversion prepulse can decrease the effectiveness of the black blood preparation. To minimize artifacts from insufficiently suppressed blood signal of the nearby blood pools, and to reduce residual respiratory motion artifacts from the chest wall, a novel local inversion technique was implemented. The combination of a nonselective inversion prepulse with a 2D selective local inversion prepulse allowed for suppression of unwanted signal outside a user-defined region of interest. Among 10 subjects evaluated using a 3D-spiral readout, the local inversion pulse effectively suppressed signal from ventricular blood, myocardium, and chest wall tissue in all cases. The coronary vessel wall could be visualized within the entire imaging volume.
Resumo:
Despite obvious improvements in spectral resolution at high magnetic field, the detection of 13C labeling by 1H-[13C] NMR spectroscopy remains hampered by spectral overlap, such as in the spectral region of 1H resonances bound to C3 of glutamate (Glu) and glutamine (Gln), and C6 of N-acetylaspartate (NAA). The aim of this study was to develop, implement, and apply a novel 1H-[13C] NMR spectroscopic editing scheme, dubbed "selective Resonance suppression by Adiabatic Carbon Editing and Decoupling single-voxel STimulated Echo Acquisition Mode" (RACED-STEAM). The sequence is based on the application of two asymmetric narrow-transition-band adiabatic RF inversion pulses at the resonance frequency of the 13C coupled to the protons that need to be suppressed during the mixing time (TM) period, alternating the inversion band downfield and upfield from the 13C resonance on odd and even scans, respectively, thus suppressing the detection of 1H resonances bound to 13C within the transition band of the inversion pulse. The results demonstrate the efficient suppression of 1H resonances bound to C3 of Glu and Gln, and C4 of Glu, which allows the 1H resonances bound to C6 of NAA and C4 of Gln to be revealed. The measured time course of the resolved labeling into NAA C6 with the new scheme was consistent with the slow turnover of NAA.
Resumo:
Objectius: Establir l’eficàcia del tractament, en quant a la millora de la qualitat de vida relacionada amb la salut (CVRS) que podem obtenir, efectuant nebulitzacions amb aigua de mar isotònica versus el sèrum fisiològic, en pacients crònics respiratoris amb MPOC. Secundàriament vol determinar si hi ha una millora subjectiva de la tolerància a l’exercici físic, una reducció significativa dels símptomes, de les aguditzacions amb els conseqüents ingressos hospitalaris i una reducció de la despesa farmacèutica. - Metodologia: Assaig clínic aleatoritzat a doble cec sobre 3 grups (aigua de mar, sèrum fisiològic i placebo) de 60 pacients d’atenció primària diagnosticats de MPOC moderada segons els criteris GOLD que hagin superat els criteris d’inclusió i exclusió. Les teràpies s’autoadministraran al propi domicili. Els resultats seran avaluats mitjançant els següents instruments: el CRQ (Chronic Respiratory Questionnaire), l’escala de dispnea del British Medical Research Council (MRC), la prova de la marxa de 6 minuts, espirometria, analítica, gasometria arterial i pulsioximetria. - Limitacions de l’estudi: Manca de participació, incompliment terapèutic, abandonament de l’hàbit tabàquic durant el tractament i pèrdues per temporalitat.
Resumo:
Brain perfusion can be assessed by CT and MR. For CT, two major techniquesare used. First, Xenon CT is an equilibrium technique based on a freely diffusibletracer. First pass of iodinated contrast injected intravenously is a second method,more widely available. Both methods are proven to be robust and quantitative,thanks to the linear relationship between contrast concentration and x-ray attenuation.For the CT methods, concern regarding x-ray doses delivered to the patientsneed to be addressed. MR is also able to assess brain perfusion using the firstpass of gadolinium based contrast agent injected intravenously. This method hasto be considered as a semi-quantitative because of the non linear relationshipbetween contrast concentration and MR signal changes. Arterial spin labelingis another MR method assessing brain perfusion without injection of contrast. Insuch case, the blood flow in the carotids is magnetically labelled by an externalradiofrequency pulse and observed during its first pass through the brain. Eachof this various CT and MR techniques have advantages and limits that will be illustratedand summarised.Learning Objectives:1. To understand and compare the different techniques for brain perfusionimaging.2. To learn about the methods of acquisition and post-processing of brainperfusion by first pass of contrast agent for CT and MR.3. To learn about non contrast MR methods (arterial spin labelling).
Resumo:
25 patients with acute myocardial infarction pain lasting more than 20 minutes which was not relieved by nitrates, whose ECGs showed ST segment elevations of 1 mm or more in 2 or more ECG leads, and who presented less than 3 hours after onset of their symptoms were randomly assigned to one of 2 thrombolytic treatment groups: a single intravenous bolus of anisoylated plasminogen streptokinase activator complex (APSAC) 30U in 5 minutes or an intravenous infusion of streptokinase 1,500,000U over 60 minutes. 3 to 4 hours after the administration of the thrombolytic agent, all patients received intravenous heparin at full dosage for 24 hours. The patency of the infarct-related coronary vessels was assessed by angiography 1 to 4 hours after administration of the thrombolytic agent. Clinical signs, ECGs, pulse, blood pressure and temperature were monitored regularly for 24 hours after treatment or as clinically appropriate. APSAC seemed to be at least as effective as streptokinase in terms of patency of the infarct-related vessel (92% vs 63%, respectively). The adverse events were similar and none was life-threatening. APSAC and streptokinase caused similar falls in blood fibrinogen levels. APSAC, given as a bolus injection over 5 minutes, was easier to administer than streptokinase, which was given as an infusion during 60 minutes.
Resumo:
Objective: Blood pressure is known to aggregate in families. Yet, heritability estimates are population-specific and no Swiss data have been published so far. Moreover, little is known on the heritability of the white-coat effect. We investigated the heritability of various blood pressure (BP) traits in a Swiss population-based sample. Methods: SKIPOGH (Swiss Kidney Project on Genes in Hypertension) is a family-based multi-centre (Lausanne, Bern, Geneva) cross-sectional study that examines the role of genes in determining BP levels. Office and 24-hour ambulatory BP were measured using validated devices (A&D UM-101 and Diasys Integra). We estimated the heritability of systolic BP (SBP), diastolic BP (DBP), heart rate (HR), pulse pressure (PP), proportional white-coat effect (i.e. [office BP-mean ambulatory daytime BP]/mean ambulatory daytime BP), and nocturnal BP dipping (difference between mean ambulatory daytime and night-time BP) using a maximum likelihood method implemented in the SAGE software. Analyses were adjusted for age, sex, body mass index (BMI), and study centre. Analyses involving PP were additionally adjusted for DBP. Results: The 517 men and 579 women included in this analysis had a mean (}SD) age of 46.8 (17.8) and 47.8 (17.1) years and a mean BMI of 26.0 (4.2) and 24.2 (4.6) kg/m2, respectively. Heritability estimates (}SE) for office SBP, DBP, HR, and PP were 0.20}0.07, 0.20}0.07, 0.39}0.08, and 0.16}0.07 (all P<0.01). Heritability estimates for 24-hour ambulatory SBP, DBP, HR, and PP were, respectively, 0.39}0.07, 0.30}.08, 0.19}0.09, and 0.25}0.08 (all P<0.05). The heritability of the white-coat effect was 0.29}0.07 for SBP and 0.31}0.07 for DBP (both P<0.001). The heritability of nocturnal BP dipping was 0.15}0.08 for SBP and 0.22}0.07 for DBP (both P<0.05). Conclusions: We found that the white-coat effect is significantly heritable. Our findings show that BP traits are moderately heritable in a multi-centric study in Switzerland, in line with previous population-based studies, justifying the ongoing search for genetic determinants in this field.
Resumo:
BACKGROUND: Direct colonic electrical stimulation may prove to be a treatment option for specific motility disorders such as chronic constipation. The aim of this study was to provoke colonic contractions using electrical stimulation delivered from a battery-operated device. METHODS: Electrodes were inserted into the caecal seromuscular layer of eight anaesthetized pigs. Contractions were induced by a neurostimulator (Medtronic 3625). Caecal motility was measured simultaneously by video image analysis, manometry and a technique assessing colonic transit. RESULTS: Caecal contractions were generated using 8-10 V amplitude, 1000 micros pulse width, 120 Hz frequency for 10-30 s, with an intensity of 7-15 mA. The maximal contraction strength was observed after 20-25 s. Electrical stimulation was followed by a relaxation phase of 1.5-2 min during which contractions propagated orally and aborally over at least 10 cm. Spontaneous and stimulated caecal motility values were significantly different for both intraluminal pressure (mean(s.d.) 332(124) and 463(187) mmHg respectively; P < 0.001, 42 experiments) and movement of contents (1.6(0.9) and 3.9(2.8) mm; P < 0.001, 40 experiments). CONCLUSION: Electrical stimulation modulated caecal motility, and provoked localized and propagated colonic contractions.
Resumo:
Spatial hearing refers to a set of abilities enabling us to determine the location of sound sources, redirect our attention toward relevant acoustic events, and recognize separate sound sources in noisy environments. Determining the location of sound sources plays a key role in the way in which humans perceive and interact with their environment. Deficits in sound localization abilities are observed after lesions to the neural tissues supporting these functions and can result in serious handicaps in everyday life. These deficits can, however, be remediated (at least to a certain degree) by the surprising capacity of reorganization that the human brain possesses following damage and/or learning, namely, the brain plasticity. In this thesis, our aim was to investigate the functional organization of auditory spatial functions and the learning-induced plasticity of these functions. Overall, we describe the results of three studies. The first study entitled "The role of the right parietal cortex in sound localization: A chronometric single pulse transcranial magnetic stimulation study" (At et al., 2011), study A, investigated the role of the right parietal cortex in spatial functions and its chronometry (i.e. the critical time window of its contribution to sound localizations). We concentrated on the behavioral changes produced by the temporarily inactivation of the parietal cortex with transcranial magnetic stimulation (TMS). We found that the integrity of the right parietal cortex is crucial for localizing sounds in the space and determined a critical time window of its involvement, suggesting a right parietal dominance for auditory spatial discrimination in both hemispaces. In "Distributed coding of the auditory space in man: evidence from training-induced plasticity" (At et al., 2013a), study B, we investigated the neurophysiological correlates and changes of the different sub-parties of the right auditory hemispace induced by a multi-day auditory spatial training in healthy subjects with electroencephalography (EEG). We report a distributed coding for sound locations over numerous auditory regions, particular auditory areas code specifically for precise parts of the auditory space, and this specificity for a distinct region is enhanced with training. In the third study "Training-induced changes in auditory spatial mismatch negativity" (At et al., 2013b), study C, we investigated the pre-attentive neurophysiological changes induced with a training over 4 days in healthy subjects with a passive mismatch negativity (MMN) paradigm. We showed that training changed the mechanisms for the relative representation of sound positions and not the specific lateralization themselves and that it changed the coding in right parahippocampal regions. - L'audition spatiale désigne notre capacité à localiser des sources sonores dans l'espace, de diriger notre attention vers les événements acoustiques pertinents et de reconnaître des sources sonores appartenant à des objets distincts dans un environnement bruyant. La localisation des sources sonores joue un rôle important dans la façon dont les humains perçoivent et interagissent avec leur environnement. Des déficits dans la localisation de sons sont souvent observés quand les réseaux neuronaux impliqués dans cette fonction sont endommagés. Ces déficits peuvent handicaper sévèrement les patients dans leur vie de tous les jours. Cependant, ces déficits peuvent (au moins à un certain degré) être réhabilités grâce à la plasticité cérébrale, la capacité du cerveau humain à se réorganiser après des lésions ou un apprentissage. L'objectif de cette thèse était d'étudier l'organisation fonctionnelle de l'audition spatiale et la plasticité induite par l'apprentissage de ces fonctions. Dans la première étude intitulé « The role of the right parietal cortex in sound localization : A chronometric single pulse study » (At et al., 2011), étude A, nous avons examiné le rôle du cortex pariétal droit dans l'audition spatiale et sa chronométrie, c'est-à- dire le moment critique de son intervention dans la localisation de sons. Nous nous sommes concentrés sur les changements comportementaux induits par l'inactivation temporaire du cortex pariétal droit par le biais de la Stimulation Transcrânienne Magnétique (TMS). Nous avons démontré que l'intégrité du cortex pariétal droit est cruciale pour localiser des sons dans l'espace. Nous avons aussi défini le moment critique de l'intervention de cette structure. Dans « Distributed coding of the auditory space : evidence from training-induced plasticity » (At et al., 2013a), étude B, nous avons examiné la plasticité cérébrale induite par un entraînement des capacités de discrimination auditive spatiale de plusieurs jours. Nous avons montré que le codage des positions spatiales est distribué dans de nombreuses régions auditives, que des aires auditives spécifiques codent pour des parties données de l'espace et que cette spécificité pour des régions distinctes est augmentée par l'entraînement. Dans « Training-induced changes in auditory spatial mismatch negativity » (At et al., 2013b), étude C, nous avons examiné les changements neurophysiologiques pré- attentionnels induits par un entraînement de quatre jours. Nous avons montré que l'entraînement modifie la représentation des positions spatiales entraînées et non-entrainées, et que le codage de ces positions est modifié dans des régions parahippocampales.
Resumo:
PURPOSE: Visualization of coronary blood flow in the right and left coronary system in volunteers and patients by means of a modified inversion-prepared bright-blood coronary magnetic resonance angiography (cMRA) sequence. MATERIALS AND METHODS: cMRA was performed in 14 healthy volunteers and 19 patients on a 1.5 Tesla MR system using a free-breathing 3D balanced turbo field echo (b-TFE) sequence with radial k-space sampling. For magnetization preparation a slab selective and a 2D selective inversion pulse were used for the right and left coronary system, respectively. cMRA images were evaluated in terms of clinically relevant stenoses (< 50 %) and compared to conventional catheter angiography. Signal was measured in the coronary arteries (coro), the aorta (ao) and in the epicardial fat (fat) to determine SNR and CNR. In addition, maximal visible vessel length, and vessel border definition were analyzed. RESULTS: The use of a selective inversion pre-pulse allowed direct visualization of the coronary blood flow in the right and left coronary system. The measured SNR and CNR, vessel length, and vessel sharpness in volunteers (SNR coro: 28.3 +/- 5.0; SNR ao: 37.6 +/- 8.4; CNR coro-fat: 25.3 +/- 4.5; LAD: 128.0 cm +/- 8.8; RCA: 74.6 cm +/- 12.4; Sharpness: 66.6 % +/- 4.8) were slightly increased compared to those in patients (SNR coro: 24.1 +/- 3.8; SNR ao: 33.8 +/- 11.4; CNR coro-fat: 19.9 +/- 3.3; LAD: 112.5 cm +/- 13.8; RCA: 69.6 cm +/- 16.6; Sharpness: 58.9 % +/- 7.9; n.s.). In the patient study the assessment of 42 coronary segments lead to correct identification of 10 clinically relevant stenoses. CONCLUSION: The modification of a previously published inversion-prepared cMRA sequence allowed direct visualization of the coronary blood flow in the right as well as in the left coronary system. In addition, this sequence proved to be highly sensitive regarding the assessment of clinically relevant stenotic lesions.
Resumo:
AIM: The study examined the effects of an oral acute administration of the beta2-agonist salbutamol (Sal) (6 mg) vs. placebo on muscle strength and fatigability in 12 non-asthmatic recreational male athletes in a randomized double-blind protocol. METHODS: Contractile properties of the right quadriceps muscle were measured during electrical stimulations, i.e. twitch, 1-s pulse trains at 20 (P(20) ) and 80 Hz (P(80) ) and during maximal voluntary isometric contraction (MVIC) before (PRE) and after (POST) a fatigue-producing protocol set by an electromyostimulation (30 contractions, frequency: 75 Hz, on-off ratio: 6.25-20s). In addition, the level of muscle voluntary activation was measured. RESULTS: In PRE and POST conditions, the peak torque (PT) of twitch, P(80) and MVIC were not modified by the treatment. The PT in POST P(20) was slightly, although not significantly, less affected by fatigue in Sal compared with placebo condition. Moreover, twitch half-relaxation time at PRE was smaller under Sal than under placebo (P < 0.05). No significant changes in the degree of voluntary activation were observed with Sal treatment in PRE or POST condition. CONCLUSION: Although these findings did not exclude completely an effect of Sal on peripheral factors of human skeletal muscle, oral acute administration of the beta2-agonist Sal seems to be without any relevant ergogenic effect on muscle contractility and fatigability in non-asthmatic recreational male athletes.
Resumo:
In (1) H magnetic resonance spectroscopy, macromolecule signals underlay metabolite signals, and knowing their contribution is necessary for reliable metabolite quantification. When macromolecule signals are measured using an inversion-recovery pulse sequence, special care needs to be taken to correctly remove residual metabolite signals to obtain a pure macromolecule spectrum. Furthermore, since a single spectrum is commonly used for quantification in multiple experiments, the impact of potential macromolecule signal variability, because of regional differences or pathologies, on metabolite quantification has to be assessed. In this study, we introduced a novel method to post-process measured macromolecule signals that offers a flexible and robust way of removing residual metabolite signals. This method was applied to investigate regional differences in the mouse brain macromolecule signals that may affect metabolite quantification when not taken into account. However, since no significant differences in metabolite quantification were detected, it was concluded that a single macromolecule spectrum can be generally used for the quantification of healthy mouse brain spectra. Alternatively, the study of a mouse model of human glioma showed several alterations of the macromolecule spectrum, including, but not limited to, increased mobile lipid signals, which had to be taken into account to avoid significant metabolite quantification errors.
Resumo:
At present, there is little fundamental guidance available to assist contractors in choosing when to schedule saw cuts on joints. To conduct pavement finishing and sawing activities effectively, however, contractors need to know when a concrete mixture is going to reach initial set, or when the sawing window will open. Previous research investigated the use of the ultrasonic pulse velocity (UPV) method to predict the saw-cutting window for early entry sawing. The results indicated that the method has the potential to provide effective guidance to contractors as to when to conduct early entry sawing. The aim of this project was to conduct similar work to observe the correlation between initial setting and conventional sawing time. Sixteen construction sites were visited in Minnesota and Missouri over a two-year period. At each site, initial set was determined using a p-wave propagation technique with a commercial device. Calorimetric data were collected using a commercial semi-adiabatic device at a majority of the sites. Concrete samples were collected in front of the paver and tested using both methods with equipment that was set up next to the pavement during paving. The data collected revealed that the UPV method looks promising for early entry and conventional sawing in the field, both early entry and conventional sawing times can be predicted for the range of mixtures tested.