967 resultados para Processing methods


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Salmonella Infantis has been the second most common serovar in Argentina in the last two years, being isolated mostly from paediatric hospitalised patients. In order to determine the clonal relationship among Salmonella Infantis strains, we examined 15 isolates from paediatric patient faeces in Argentina (12 geographically related and 3 geographically non-related) by using antimicrobial susceptibility, plasmid profiling, repetitive extragenic palindromic (REP) PCR, enterobacterial repetitive intergenic consensus (ERIC) PCR, and low-frequency restriction analysis of chromosomal DNA by pulsed field gel electrophoresis (PFGE). Four Spanish strains were included as controls of clonal diversity in molecular techniques. Antibiotype and plasmid profile was not useful as epidemiological tools. PFGE and REP-PCR were able to discriminate between Argentinean and Spanish isolates of Salmonella Infantis allowing to detect genetically related strains in three different cities. This finding indicates that a possible spread of a clone of this serovar in the North-eastern Region of Argentina has taken place in 1998.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ecological Water Quality - Water Treatment and Reuse

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work measures and tries to compare the Antioxidant Capacity (AC) of 50 commercial beverages of different kinds: 6 wines, 12 beers, 18 soft drinks and 14 flavoured waters. Because there is no reference procedure established for this purpose, three different optical methods were used to analyse these samples: Total Radical trapping Antioxidant Parameter (TRAP), Trolox Equivalent Antioxidant Capacity (TEAC) and Ferric ion Reducing Antioxidant Parameter (FRAP). These methods differ on the chemical background and nature of redox system. The TRAP method involves the transfer of hydrogen atoms while TEAC and FRAP involves electron transfer reactions. The AC was also assessed against three antioxidants of reference, Ascorbic acid (AA), Gallic acid (GA) and 6-hydroxy-2,5,7,8-tetramethyl- 2-carboxylic acid (Trolox). The results obtained were analyzed statistically. Anova one-way tests were applied to all results and suggested that methods and standards exhibited significant statistical differences. The possible effect of sample features in the AC, such as gas, flavours, food colouring, sweeteners, acidity regulators, preservatives, stabilizers, vitamins, juice percentage, alcohol percentage, antioxidants and the colour was also investigated. The AC levels seemed to change with brand, kind of antioxidants added, and kind of flavour, depending on the sample. In general, higher ACs were obtained for FRAP as method, and beer for kind of sample, and the standard expressing the smaller AC values was GA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: A new method for determining serum specific IgE (IMMULITE“ 2000 3gAllergy) has recently become available. Objective: To evaluate the clinical performance of IMMULITE 2000 in the diagnosis of cow’s milk allergy compared with that of UniCAP“. Additionally, we verified the behavior of both methods at two diagnostic decision points proposed by other authors. Methods: The study population consisted of 31 children with cow’s milk allergy (group A) and a control group of 19 atopic children without food allergy(group B). A blood sample from each child was tested using both methods and the results were compared. Results: In group A, the values for cow’s milk IgE ranged from 0.35 kU/L (the lowest common detection limit) to above 100 kU/L. In group B, the values were less than 1.1 kU/L for IMMULITE 2000 and less than 1.6 kU/L for UniCAP. An agreement of 90 % in IgE classes was obtained. Both methods demonstrated exactly the same diagnostic performance(sensitivity: 100 %; specificity: 78.9 %; negative predictive value: 100%; positive predictive value: 84.6%;efficiency: 90.2 %). The evaluation of the two methods at the two different decision points proposed in the literature showed a better positive predictive value with UniCAP, but we obtained equivalent performance with IMMULITE 2000 by choosing higher cutoff values. Conclusions: We conclude that IMMULITE 2000 is as effective as UniCAP in the diagnosis of cow’s milk allergy. Both methods can be used to obtain site-specific decision points that are population, age and disease dependent.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare measurements of the upper arm cross-sectional areas (total arm area,arm muscle area, and arm fat area of healthy neonates) as calculated using anthropometry with the values obtained by ultrasonography. Materials and methods: This study was performed on 60 consecutively born healthy neonates: gestational age (mean6SD) 39.661.2 weeks, birth weight 3287.16307.7 g, 27 males (45%) and 33 females (55%). Mid-arm circumference and tricipital skinfold thickness measurements were taken on the left upper mid-arm according to the conventional anthropometric method to calculate total arm area, arm muscle area and arm fat area. The ultrasound evaluation was performed at the same arm location using a Toshiba sonolayer SSA-250AÒ, which allows the calculation of the total arm area, arm muscle area and arm fat area by the number of pixels enclosed in the plotted areas. Statistical analysis: whenever appropriate, parametric and non-parametric tests were used in order to compare measurements of paired samples and of groups of samples. Results: No significant differences between males and females were found in any evaluated measurements, estimated either by anthropometry or by ultrasound. Also the median of total arm area did not differ significantly with either method (P50.337). Although there is evidence of concordance of the total arm area measurements (r50.68, 95% CI: 0.55–0.77) the two methods of measurement differed for arm muscle area and arm fat area. The estimated median of measurements by ultrasound for arm muscle area were significantly lower than those estimated by the anthropometric method, which differed by as much as 111% (P,0.001). The estimated median ultrasound measurement of the arm fat was higher than the anthropometric arm fat area by as much as 31% (P,0.001). Conclusion: Compared with ultrasound measurements using skinfold measurements and mid-arm circumference without further correction may lead to overestimation of the cross-sectional area of muscle and underestimation of the cross-sectional fat area. The correlation between the two methods could be interpreted as an indication for further search of correction factors in the equations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The underground scenarios are one of the most challenging environments for accurate and precise 3d mapping where hostile conditions like absence of Global Positioning Systems, extreme lighting variations and geometrically smooth surfaces may be expected. So far, the state-of-the-art methods in underground modelling remain restricted to environments in which pronounced geometric features are abundant. This limitation is a consequence of the scan matching algorithms used to solve the localization and registration problems. This paper contributes to the expansion of the modelling capabilities to structures characterized by uniform geometry and smooth surfaces, as is the case of road and train tunnels. To achieve that, we combine some state of the art techniques from mobile robotics, and propose a method for 6DOF platform positioning in such scenarios, that is latter used for the environment modelling. A visual monocular Simultaneous Localization and Mapping (MonoSLAM) approach based on the Extended Kalman Filter (EKF), complemented by the introduction of inertial measurements in the prediction step, allows our system to localize himself over long distances, using exclusively sensors carried on board a mobile platform. By feeding the Extended Kalman Filter with inertial data we were able to overcome the major problem related with MonoSLAM implementations, known as scale factor ambiguity. Despite extreme lighting variations, reliable visual features were extracted through the SIFT algorithm, and inserted directly in the EKF mechanism according to the Inverse Depth Parametrization. Through the 1-Point RANSAC (Random Sample Consensus) wrong frame-to-frame feature matches were rejected. The developed method was tested based on a dataset acquired inside a road tunnel and the navigation results compared with a ground truth obtained by post-processing a high grade Inertial Navigation System and L1/L2 RTK-GPS measurements acquired outside the tunnel. Results from the localization strategy are presented and analyzed.