979 resultados para Prótese fixa
Resumo:
The information about the knowledge and usage of denture adhesives is still limited, particularly in Brazilian populations. Objective: The purpose of this study was to investigate the aspects related to the use or nonuse of denture adhesives by complete denture wearers. Material and method: Questionnaires were applied to 100 bimaxillary complete denture wearers concerning their usage of denture adhesives. The survey was carried out according to three categories: those who had never tried adhesive, those who had tried adhesive at least once but no longer used it, and those who currently used it. Result: Of the 100 participants, 80% had never tried adhesives, 16% had tried at least once but no longer used it and 4% had used on a regular basis. Conclusion: Within the limitations of this study, the results of this subjective assessment suggest that within the participants that had never tried adhesives, 77.5% inform that the adhesive is not needed, and all participants who regularly use it inform its efficiency.
Resumo:
The Combination Syndrome represents an important pathologic condition of the masticatory system that requires a complex rehabilitation treatment. The presence of flaccid mucosa is one of the most common features due to bone resorption of the pre-maxilla caused by anterior hyperfunction of the mandibular teeth on the maxillary complete denture, where the impact of oclusal loading in this region results in movement of the maxillary prosthesis into the ridge, resulting in increased resorption of the residual ridge, internal misfit and loss of the retention of the maxillary complete denture. The presence of flaccid mucosa, in such cases, leads to problems of support and stability of the maxillary complete denture, which can be treated by surgical reduction of the thickness of the tissue or using specific techniques of fabrication of prostheses. This article describes the oral rehabilitation of a patient with the Combination Syndrome where the surgical reduction of flaccid mucosa was not performed, using a modified technique of functional impression in two steps, with the objective of generating forces and less distortion in flaccid mucosa during functional impression.
Resumo:
Introduction: the oral rehabilitation in edentulous patients using removable complete dentures is a classic treatment, easily accessible, and presenting satisfactory results. However, to succeed in this type of treatment, stability is an extremely important factor. The neutral zone technique for the production of complete dentures determines the oral cavity space for the positioning of teeth and denture base that provide a neutralization of the forces delivered by lips, cheeks, and tongue, providing better stability and retention of prostheses, which is indicated in cases with history of difficulties in adapting the conventional mandibular denture. Objective and case report: this paper aimed to describe a clinical case report of the oral rehabilitation of a patient with paraprosthetic muscles hypertonicity through removable complete dentures produced by the neutral zone technique, using condensation silicone. Final considerations: the use of condensation silicone for the development of the neutral zone technique showed to be a good alternative for the development of this clinical case, providing satisfactory stability and retention of the complete mandibular denture.
Resumo:
Objective and Case report: The purpose of this paper is to describe the neutral zone technique in a patient with oral deformity on the right labial commissure due to the resection of an oral cancer, enhancing the difficulty resulting from mouth limited opening and the use of tissue conditioner material to determine the neutral zone. Complete denture was obtained through this technique, providing good retention and stability which made functional rehabilitation feasible to patient of his or her masticatory function. Final considerations: The neutral zone technique in complete dentures will determine a specific intraoral area for tooth position and denture base contour where the forces generated by lips, cheeks and tongue are neutralized. The objective of this technique is to provide an alternative approach for patients who presented an historic instability of lower complete denture: atrophic ridge, oral deformities and also with disorder problems. An oral rehabilitation using this technique improves comfort to the patient providing retention and stability of mandibular complete dentures.
Resumo:
Unilateral or bilateral distal-extension removable partial dentures present complex biomechanics. The movements in different directions, associated with the alveolar ridge shape and soft tissue resilience can lead to damaging forces on the supporting structures. The association between implants / removable partial denture aims to provide better mechanical and biological properties to the stomatognathic system. OBJECTIVE: The aim of this paper was to review the articles about the effect of implant support on distal extension removable partial dentures. LITERATURE REVIEW AND CONCLUSION: Studies have shown that this combination provides greater support, retention and stability to the prosthesis, thus limiting their approach movement toward supporting tissues and providing functional and psychological comfort to patients.
Resumo:
Introduction: Unilateral or bilateral distal-extension removable partial dentures present complex biomechanics. The movements in different directions, associated with the alveolar ridge shape and soft tissue resilience can lead to damaging forces on the supporting structures. The association between implants / removable partial denture aims to provide better mechanical and biological properties to the stomatognathic system. Objective: The aim of this paper was to review the articles about the effect of implant support on distal extension removable partial dentures. Literature review and conclusion: Studies have shown that this combination provides greater support, retention and stability to the prosthesis, thus limiting their approach movement toward supporting tissues and providing functional and psychological comfort to patients.
Resumo:
The objective of this study was to evaluate the impact of replacing conventional mandibular complete dentures by complete fixed dentures on the oral health-related quality of life and kinesiographic parameters of maxillary edentulous patients. Material and Methods: edentulous patients (n = 16) received one set of new complete dentures and after the intraoral adjustments and adaptation period (30 days), the Brazilian version of Oral Health Impact Profile for assessing edentulous subjects (Ohip-Edent) was used to evaluate the oral health-related quality of life (OHQOL) of the participants. Additionally, the kinesiograph instrument K6-I (Myotronics Research Inc., Seattle, WA) was used to record opening and closure range of movement, mandibular movement, and the pattern of maxillary complete denture movement on chewing. Afterwards, the patients had their mandibular complete dentures replaced by a complete fixed denture and the same evaluation protocol was performed after 3 and 6 months. Ohip-Edent responses were analyzed using Wilcoxon's test for repeated measures (α = .05) and Kinesiographic data using the Student´s t test (α = .05). Results: The Ohip-Edent showed an improvement of general oral health-related quality of life after 3 and 6 months of the treatment with complete fixed dentures. Kinesiographic recordings revealed a significant increase on maximum mandibular movements of vertical opening and no differences for the movement of the maxillary complete denture on chewing after treatment with complete fixed dentures was observed. Conclusion: the installation of complete fixed dentures improved the OHQOL and changed mandibular movements, with increases in vertical amplitude of maximal opening.
Resumo:
This work reports the experimental evaluation of physical and gas permeation parameters of four spinel-based investments developed with or without inclusion of sacrificial fillers. Data were compared with those of three commercial formulations. Airflow tests were conducted from 27 to 546°C, and permeability coefficients were fitted from Forchheimer's equation. Skeletal densities found for spinel- (ρs = 3635 ± 165 kg/m3) and phosphate-bonded (ρs = 2686 ± 11 kg/m3) samples were in agreement with the literature. The developed investments were more porous and less permeable than commercial brands, and the differences were ascribed to the different pore morphologies and hydraulic pore sizes of ceramic matrices. The inclusion of both fibers and microbeads resulted in increases of total porosity (42.6–56.6%) and of Darcian permeability coefficient k1 (0.76 × 10−14–7.03 × 10−14 m2). Air permeation was hindered by increasing flow temperatures, and the effect was related to the influence of gas viscosity on ΔP, in accordance with Darcy's law. Casting quality with molten titanium (CP Ti) was directly proportional to the permeability level of the spinel-based investments. However, the high reactivity of the silica-based investment RP and the formation of α-case during casting hindered the benefits of the highest permeability level of this commercial brand.
Resumo:
The purpose of this in vitro study was to evaluate the effect of air-abrasion/zirconia sintering order on the yttria partially stabilized tetragonal zirconia polycrystal (Y-TZP) surface characterization (roughness, morphology, and phase transformation), flexural strength (FS), and shear bond strength (SBS) to a resin cement. Y-TZP specimens were air abraded with 50-μm Al2O3 particles after (AS), before (BS), or before and after zirconia sintering (BAS). For roughness (Ra), 30 block specimens (12×12×3.0 mm; n=10) had their surfaces analyzed by a profilometer. Next, on the air-abraded surfaces of these specimens, composite resin discs (n=30) were bonded with RelyX ARC. The bonded specimens were stored for 24 hours in distilled water at 37°C before shear testing. Failure mode was determined with a stereomicroscope (20×). The surface morphology (n=2) was evaluated by SEM (500×). For the four-point flexural strength test (EMIC DL2000), 39 bar-shaped specimens (20×4.0×1.2 mm; n=13) were air abraded according to the three conditions proposed, and an additional group (nonabraded) was evaluated (n=13). The quantitative analysis of phase transformation (n=1) was completed with Rietveld refinement with X-ray diffraction data. Ra (μm) and SBS (MPa) data were analyzed by one-way analysis of variance (ANOVA) and the Tukey test (α=0.05). Pearson correlation analysis was used to determine if there was a correlation between roughness and SBS. For FS (MPa) data, one-way ANOVA and the Dunnett C-test (α=0.05) were used. The air-abrasion/zirconia sintering order influenced significantly (p<0.001) Ra, SBS, and FS. The BS and AS groups presented the highest (1.3 μm) and the lowest (0.7 μm) Ra. The highest SBS (7.0 MPa) was exhibited by the BAS group, followed by the AS group (5.4 MPa) and finally by the BS group (2.6 MPa). All groups presented 100% adhesive failure. A weak correlation (r=−0.45, p<0.05) was found between roughness and SBS. The air-abrasion/zirconia sintering order provided differences in the surface morphology. The nonabraded (926.8 MPa) and BS (816.3 MPa) groups exhibited statistically similar FS values but lower values than the AS (1249.1 MPa) and BAS (1181.4 MPa) groups, with no significant difference between them. The nonabraded, AS, BS, and BAS groups exhibited, respectively, percentages of monoclinic phase of 0.0 wt%, 12.2 wt%, 0.0 wt%, and 8.6 wt%. The rougher surface provided by the air-abrasion before zirconia sintering may have impaired the bonding with the resin cement. The morphological patterns were consistent with the surface roughness. Considering the short-term SBS and FS, the BAS group exhibited the best performance. Air abrasion, regardless of its performance order, provides tetragonal to monoclinic transformation, while sintering tends to zero the monoclinic phase content.
Resumo:
Statement of problem Because zirconia is a glass-free material, alternative surface treatments such as airborne-particle abrasion or silica coating should be used for long-term bonding. However, these surface treatments in combination with different bonding agents and luting cements have not yet been studied. Purpose The purpose of the study was to evaluate the effect of surface treatments on the shear bond strength (SBS) of luting cements to Y-TZP ceramic. Material and methods Zirconia disks (N=240) were airborne-particle abraded with the following particles (n=48): 50 μm Al2O3; 120 μm Al2O3; 30 μm silica-coated Al2O3 (Rocatec Soft); 120 μm Al2O3+110 μm silica-coated Al2O3 (Rocatec Plus); and Rocatec Plus. After silanization of the zirconia surface, composite resin disks were bonded with (n=12) RelyX Luting 2; RelyX ARC; RelyX U100; and Panavia F. The bonded specimens were thermocycled (10 000 cycles) and tested for SBS. Failure mode was determined with a stereomicroscope (×20). The morphology and elemental composition of airborne-particle abraded surfaces were evaluated with scanning electron microscopy (×500) and energy-dispersive x-ray spectroscopy (×50). Results Surface treatments, cements, and their interaction were significant (P<.001). For RelyX ARC, Rocatec Soft and Rocatec Plus provided the highest SBS. In general, surface treatments did not influence the SBS of RelyX U100 and Panavia F. Regardless of the cement, no significant difference was found between 50 μm and 120 μm Al2O3 particles, between Rocatec Soft and Rocatec Plus, or between Rocatec Plus and 120 μm Al2O3 particles+Rocatec Plus. All groups showed adhesive failures. Different particle sizes provided differences in morphological patterns. The elemental composition comprised Al and Al/Si for alumina and silica-abraded zirconia. Conclusions Particle size did not influence the SBS of the groups abraded exclusively with alumina or silica-coated particles. RelyX ARC was more surface-treatment dependent than RelyX U100 or Panavia F.
Resumo:
The possibilities of treatment with dental implants have revolutionized the field of oral rehabilitation in recent years, bringing a number of advantages over conventional prostheses. For years, a surgical protocol was followed that called for maintaining the implant without load for a certain period for osseointegration, but experimental studies have shown that immediate loading of implants also leads to the formation of peri-implant bone tissue along the time, similarly to that observed for conventionally loaded implants. This study aimed to conduct a literature review regarding the use of this alternative rehabilitation with single implants. The immediate loading of single-tooth replacements is presented as an excellent treatment alternative.
Resumo:
Ao paciente é necessário fornecer esclarecimentos sobre as possibilidades terapêuticas, apresentando os riscos, benefícios, prognóstico e custos de cada alternativa possível e indicada. Esta é uma determinação ética e jurídica. Não obstante, o profissional da saúde detém o conhecimento clínico/técnico/científico, e determina quais informações serão (ou não) fornecidas. O paciente decide submeter-se a um tratamento, fornecendo o seu Consentimento Livre e Esclarecido com base nos dados a ele apresentados. Infelizmente, pode ocorrer de alguns profissionais não fornecerem todas as informações necessárias a uma tomada de decisão esclarecida ou, depois de obtido o consentimento do paciente, apresentarem-lhe informação que cause sua desistência do tratamento inicialmente aceito. Esta última informação, se pertinente, e não se tratando de fato superveniente, deveria ter sido fornecida inicialmente. Porém, a informação pode não ser de todo verdadeira, e levar o paciente a decidir baseado, por exemplo, em riscos apresentados e mensurados de forma equivocada. A reabilitação crânio-facial da Articulação Têmporo-Mandibular (ATM), por meio de prótese de ATM, é indicada em muitas situações. Amiúde, pacientes que necessitam de tais próteses apresentam problemas funcionais e estéticos; a expectativa gerada com a reabilitação é grande. Este trabalho apresenta um caso e discute questões éticas e legais, incluindo a responsabilidade civil, do fornecimento parcial e inadequado de esclarecimentos a um paciente.