994 resultados para Pareto solution
Resumo:
Restoration of joint centre during total hip arthroplasty is critical. While computer-aided navigation can improve accuracy during total hip arthroplasty, its expense makes it inaccessible to the majority of surgeons. This article evaluates the use, in the laboratory, of a calliper with a simple computer application to measure changes in femoral head centres during total hip arthroplasty. The computer application was designed using Microsoft Excel and used calliper measurements taken pre- and post-femoral head resection to predict the change in head centre in terms of offset and vertical height between the femoral head and newly inserted prosthesis. Its accuracy was assessed using a coordinate measuring machine to compare changes in preoperative and post-operative head centre when simulating stem insertion on 10 sawbone femurs. A femoral stem with a modular neck was used, which meant nine possible head centre configurations were available for each femur, giving 90 results. The results show that using this technique during a simulated total hip arthroplasty, it was possible to restore femoral head centre to within 6?mm for offset (mean 1.67?±?1.16?mm) and vertical height (mean 2.14?±?1.51?mm). It is intended that this low-cost technique be extended to inform the surgeon of a best-fit solution in terms of neck length and neck type for a specific prosthesis.
Resumo:
This article reconstructs British constitutional policy in Northern Ireland after power-sharing collapsed in May 1974. Over the following two years, the British government publicly emphasised that Northern Ireland would decide its own future, but ministers secretly considered a range of options including withdrawal, integration and Dominion status. These discussions have been fundamentally misunderstood by previous authors, and this article shows that Harold Wilson did not seriously advocate withdrawal nor was policy as inconsistent as argued elsewhere. An historical approach, drawing from recently released archival material, shows that consociationalists such as Brendan O'Leary and Michael Kerr have neglected the proper context of government policy because of their commitment to a particular form of government, failing to recognise the constraints under which ministers operated. The British government remained committed to an internal devolved settlement including both communities but was unable to impose one.
Resumo:
With the help of in situ multi-step FTIR Spectroscopy, two types of adsorbed geminal CO have been observed for the first time at an electrochemically modified Rh electrode. A doublet band of two broad peaks at 2166 and 2112cm is assigned to geminal CO on Rh surface oxide (or hydroxide) produced by the electrochemical modification process, and a doublet band of two peaks near 2103 and 2033cm is ascribed to geminal CO on surface clusters of Rh formed by reduction of Rh surface oxide. Based on the evolution of FTIR spectra with the electrode potential, the surface processes of a Rh electrode, subjected to a potential cycling treatment at 1.5Vs between -0.275 and 2.4V for 2min, have been elucidated. The present results at the solid/liquid electrochemical interface were compared with those obtained at the solid/gas interface, and consistent conclusions were achieved.
Resumo:
Many of the physiological functions of von Willebrand Factor (VWF), including its binding interaction with blood platelets, are regulated by the magnitude of applied fluid/hydrodynamic stress. We applied two complementary strategies to study the effect of fluid forces on the solution structure of VWF. First, small-angle neutron scattering was used to measure protein conformation changes in response to laminar shear rates (G) up to 3000/s. Here, purified VWF was sheared in a quartz Couette cell and protein conformation was measured in real time over length scales from 2-140 nm. Second, changes in VWF structure up to 9600/s were quantified by measuring the binding of a fluorescent probe 1,1'-bis(anilino)-4-,4'-bis(naphtalene)-8,8'-disulfonate (bis-ANS) to hydrophobic pockets exposed in the sheared protein. Small angle neutron scattering studies, coupled with quantitative modeling, showed that VWF undergoes structural changes at G < 3000/s. These changes were most prominent at length scales <10 nm (scattering vector (q) range >0.6/nm). A mathematical model attributes these changes to the rearrangement of domain level features within the globular section of the protein. Studies with bis-ANS demonstrated marked increase in bis-ANS binding at G > 2300/s. Together, the data suggest that local rearrangements at the domain level may precede changes at larger-length scales that accompany exposure of protein hydrophobic pockets. Changes in VWF conformation reported here likely regulate protein function in response to fluid shear.
Resumo:
Purpose: The aim of this work was to determine if volumetric modulated arc therapy (VMAT) plans, created for constant dose-rate (cdrVMAT) delivery are a viable alternative to step and shoot five-field intensity modulated radiation therapy (IMRT). Materials and methods: The cdrVMAT plans, inverse planned on a treatment planning system with no solution to account for couch top or rails, were created for delivery on a linear accelerator with no variable dose rate control system. A series of five-field IMRT and cdrVMAT plans were created using dual partial arcs (gantry rotating between 260° and 100°) with 4° control points for ten prostate patients with the average rectal constraint incrementally increased. Pareto fronts were compared for the planning target volume homogeneity and average rectal dose between the two techniques for each patient. Also investigated were tumour control probability and normal tissue complication probability values for each technique. The delivery parameters [monitor units (MU) and time] and delivery accuracy of the IMRT and VMAT plans were also compared. Results: Pareto fronts showed that the dual partial arc plans were superior to the five-field IMRT plans, particularly for the clinically acceptable plans where average rectal doses were less for rotational plans (p = 0·009) with no statistical difference in target homogeneity. The cdrVMAT plans had significantly more MU (p = 0·005) but the average delivery time was significantly less than the IMRT plans by 42%. All clinically acceptable cdrVMAT plans were accurate in their delivery (gamma 99·2 ± 1·1%, 3%3 mm criteria). Conclusions Accurate delivery of dual partial arc cdrVMAT avoiding the couch top and rails has been demonstrated.
Resumo:
The dimensions and cavity sizes of the molecular capsules with the general formula [V10O18L4]10− can be controlled modularly through the nature of the bifunctional, rigid organophosphonate ligands L1 and L2 (L1 = bis(4-phosphonatophenyl)ethyne and L2 = bis(4-phosphonatophenyl)butadiyne); the solution stability of the molecular entities as demonstrated by ESI-MS studies permits their assembly on the Au(111) surface on a sub-monolayer scale giving rise to a 2D supramolecular structure that is comparable to the packing arrangements of the capsules in the crystal structures.
Resumo:
An experimental study on the adsorption of phosphate onto cost effective fine dolomite powder is presented. The effect of solution pH, solution ionic strength and adsorption isotherm were examined. The adsorption of phosphate was pH dependent and phosphate adsorption favoured acidic conditions. The adsorption was significantly influenced by solution ionic strength indicating outer-sphere complexation reactions. The experimental data further indicated that the removal of phosphate increased with increase in the ionic strength of solution. The experimental data were modelled with different isotherms: Langmuir, Freundlich and Redlich–Peterson isotherms. It was found that the Redlich–Peterson isotherm depicted the equilibrium data most accurately. The overall kinetic data fitted very well the pseudo-first-order rate model.
Resumo:
Patients in perioperative healthcare settings are at risk of acquiring or developing infections because of the performance of invasive procedures. Serious life threatening infections can arise when micro-organisms are transmitted onto susceptible sites, such as: surgical wounds or intravascular cannulation sites. Infection control practices help to protect patients and healthcare providers by reducing and/or eliminating sources of infection.
Resumo:
Purpose
– Traditionally, most studies focus on institutionalized management-driven actors to understand technology management innovation. The purpose of this paper is to argue that there is a need for research to study the nature and role of dissident non-institutionalized actors’ (i.e. outsourced web designers and rapid application software developers). The authors propose that through online social knowledge sharing, non-institutionalized actors’ solution-finding tensions enable technology management innovation.
Design/methodology/approach
– A synthesis of the literature and an analysis of the data (21 interviews) provided insights in three areas of solution-finding tensions enabling management innovation. The authors frame the analysis on the peripherally deviant work and the nature of the ways that dissident non-institutionalized actors deviate from their clients (understood as the firm) original contracted objectives.
Findings
– The findings provide insights into the productive role of solution-finding tensions in enabling opportunities for management service innovation. Furthermore, deviant practices that leverage non-institutionalized actors’ online social knowledge to fulfill customers’ requirements are not interpreted negatively, but as a positive willingness to proactively explore alternative paths.
Research limitations/implications
– The findings demonstrate the importance of dissident non-institutionalized actors in technology management innovation. However, this work is based on a single country (USA) and additional research is needed to validate and generalize the findings in other cultural and institutional settings.
Originality/value
– This paper provides new insights into the perceptions of dissident non-institutionalized actors in the practice of IT managerial decision making. The work departs from, but also extends, the previous literature, demonstrating that peripherally deviant work in solution-finding practice creates tensions, enabling management innovation between IT providers and users.
Resumo:
The scale of BT's operations necessitates the use of very large scale computing systems, and the storage and management of large volumes of data. Customer product portfolios are an important form of data which can be difficult to store in a space efficient way. The difficulties arise from the inherently structured form of product portfolios, and the fact that they change over time as customers add or remove products. This paper introduces a new data-modelling abstraction called the List_Tree. It has been designed specifically to support the efficient storage and manipulation of customer product portfolios, but may also prove useful in other applications with similar general requirements.
Resumo:
In this study, the stress-corrosion cracking (SCC) behaviour of laser-welded NiTi wires before and after post-weld heat-treatment (PWHT) was investigated. The samples were subjected to slow strain rate testing (SSRT) under tensile loading in Hanks’ solution at 37.5 °C (or 310.5 K) at a constant anodic potential (200 mVSCE). The current density of the samples during the SSRT was captured by a potentiostat, and used as an indicator to determine the susceptibility to SCC. Fractography was analyzed using scanning-electron microscopy (SEM). The experimental results showed that the laser-welded sample after PWHT was immune to the SCC as evidenced by the stable current density throughout the SSRT. This is attributed to the precipitation of fine and coherent nano-sized Ni4Ti3 precipitates in the welded regions (weld zone, WZ and heat-affected zone, HAZ) after PWHT, resulting in (i) enrichment of TiO2 content in the passive film and (ii) higher resistance against the local plastic deformation in the welded regions.
Resumo:
A revised water model intended for use in condensed phase simulations in the framework of the self consistent polarizable ion tight binding theory is constructed. The model is applied to water monomer, dimer, hexamers, ice, and liquid, where it demonstrates good agreement with theoretical results obtained by more accurate methods, such as DFT and CCSD(T), and with experiment. In particular, the temperature dependence of the self diffusion coefficient in liquid water predicted by the model, closely reproduces experimental curves in the temperature interval between 230 K and 350 K. In addition, and in contrast to standard DFT, the model properly orders the relative densities of liquid water and ice. A notable, but inevitable, shortcoming of the model is underestimation of the static dielectric constant by a factor of two. We demonstrate that the description of inter and intramolecular forces embodied in the tight binding approximation in quantum mechanics leads to a number of valuable insights which can be missing from ab initio quantum chemistry and classical force fields. These include a discussion of the origin of the enhanced molecular electric dipole moment in the condensed phases, and a detailed explanation for the increase of coordination number in liquid water as a function of temperature and compared with ice-leading to insights into the anomalous expansion on freezing. The theory holds out the prospect of an understanding of the currently unexplained density maximum of water near the freezing point.