999 resultados para Oriented Cue Exposure


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The association between oral bisphosphonate use and upper gastrointestinal cancer has been controversial. Therefore, we examined the association with esophageal and gastric cancer within the Kaiser Permanente, Northern California population. A total of 1,011 cases of esophageal (squamous cell carcinoma and adenocarcinoma) and 1,923 cases of gastric adenocarcinoma (cardia, non-cardia and other) diagnosed between 1997 and 2011 from the Kaiser Permanente, Northern California cancer registry were matched to 49,886 and 93,747 controls, respectively. Oral bisphosphonate prescription fills at least one year prior to the index date were extracted. Conditional logistic regression was used to calculate odds ratios (OR) and 95% confidence intervals (95% CI) for the associations between prospectively evaluated oral bisphosphonate use with incident esophageal and gastric cancer diagnoses with adjustment for potential confounders. After adjustment for potential confounders, no significant associations were found for esophageal squamous cell carcinoma (OR 0.88; 95% CI: 0.51, 1.52), esophageal adenocarcinoma (OR 0.68; 95% CI: 0.37, 1.24), or gastric non-cardia adenocarcinoma (OR 0.83, 95% CI: 0.59, 1.18), but we observed an adverse association with gastric cardia adenocarcinoma (OR 1.64; 95% CI: 1.07, 2.50). In conclusion, we observed no association between oral bisphosphonate use and esophageal cancer risk within a large community-based population. A significant association was detected with gastric cardia and other adenocarcinoma risk, although this needs to be replicated.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Este estudo baseou-se na análise dos mecanismos de transferência de elementos potencialmente tóxicos (PTE’s) entre o solo, a solução do solo e as plantas como forma de realizar uma avaliação mais eficaz do risco em áreas agrícolas. Foram aplicados conceitos recentemente desenvolvidos para a avaliação da reactividade biogeoquímica de contaminantes no solo e da sua partição sólido:solução recorrendo-se a modelos empíricos (tipo Freundlich). Estes modelos permitiram analisar a transferência de PTE’s ao longo da cadeia alimentar e avaliar o impacto da contaminação do solo na qualidade da alimentação animal (forragens) e Humana (vegetais e carne) em Portugal. Os modelos empíricos de transferência solo-planta de PTE’s foram utilizadas para obter limites críticos para estes elementos em solos agrícolas em Portugal, a partir dos seus limites legais nos alimentos para animais e teores máximos nos géneros alimentícios. Simultaneamente, modelos de exposição Humana a contaminantes do solo, desenvolvidos noutros países da UE foram analisados e foi proposto um modelo de exposição para Portugal. Este trabalho é uma contribuição para o desenvolvimento de critérios de qualidade de solos para áreas agrícolas em Portugal, tendo em vista a protecção da saúde animal e Humana. Contribuiu também para o desenvolvimento de uma estratégia de harmonização de políticas de protecção do solo (nomeadamente no que diz respeito aos problemas de contaminação) na União Europeia.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Esta tese pretende contribuir para o estudo e análise dos factores relacionados com as técnicas de aquisição de imagens radiológicas digitais, a qualidade diagnóstica e a gestão da dose de radiação em sistema de radiologia digital. A metodologia encontra-se organizada em duas componentes. A componente observacional, baseada num desenho do estudo de natureza retrospectiva e transversal. Os dados recolhidos a partir de sistemas CR e DR permitiram a avaliação dos parâmetros técnicos de exposição utilizados em radiologia digital, a avaliação da dose absorvida e o índice de exposição no detector. No contexto desta classificação metodológica (retrospectiva e transversal), também foi possível desenvolver estudos da qualidade diagnóstica em sistemas digitais: estudos de observadores a partir de imagens arquivadas no sistema PACS. A componente experimental da tese baseou-se na realização de experiências em fantomas para avaliar a relação entre dose e qualidade de imagem. As experiências efectuadas permitiram caracterizar as propriedades físicas dos sistemas de radiologia digital, através da manipulação das variáveis relacionadas com os parâmetros de exposição e a avaliação da influência destas na dose e na qualidade da imagem. Utilizando um fantoma contrastedetalhe, fantomas antropomórficos e um fantoma de osso animal, foi possível objectivar medidas de quantificação da qualidade diagnóstica e medidas de detectabilidade de objectos. Da investigação efectuada, foi possível salientar algumas conclusões. As medidas quantitativas referentes à performance dos detectores são a base do processo de optimização, permitindo a medição e a determinação dos parâmetros físicos dos sistemas de radiologia digital. Os parâmetros de exposição utilizados na prática clínica mostram que a prática não está em conformidade com o referencial Europeu. Verifica-se a necessidade de avaliar, melhorar e implementar um padrão de referência para o processo de optimização, através de novos referenciais de boa prática ajustados aos sistemas digitais. Os parâmetros de exposição influenciam a dose no paciente, mas a percepção da qualidade de imagem digital não parece afectada com a variação da exposição. Os estudos que se realizaram envolvendo tanto imagens de fantomas como imagens de pacientes mostram que a sobreexposição é um risco potencial em radiologia digital. A avaliação da qualidade diagnóstica das imagens mostrou que com a variação da exposição não se observou degradação substancial da qualidade das imagens quando a redução de dose é efectuada. Propõe-se o estudo e a implementação de novos níveis de referência de diagnóstico ajustados aos sistemas de radiologia digital. Como contributo da tese, é proposto um modelo (STDI) para a optimização de sistemas de radiologia digital.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Atualmente, a poluição atmosférica constitui uma das principais causas ambientais de mortalidade. Cerca de 30% da população europeia residente em áreas urbanas encontra-se exposta a níveis de poluição atmosférica superiores aos valores- limite de qualidade do ar legislados para proteção da saúde humana, representando o tráfego rodoviário uma das principais fontes de poluição urbana. Além dos poluentes tradicionais avaliados em áreas urbanas, os poluentes classificados como perigosos para a saúde (Hazard Air Pollutants - HAPs) têm particular relevância devido aos seus conhecidos efeitos tóxicos e cancerígenos. Neste sentido, a avaliação da exposição tornase primordial para a determinação da relação entre a poluição atmosférica urbana e efeitos na saúde. O presente estudo tem como principal objetivo o desenvolvimento e implementação de uma metodologia para avaliação da exposição individual à poluição atmosférica urbana relacionada com o tráfego rodoviário. De modo a atingir este objetivo, foram identificados os parâmetros relevantes para a quantificação de exposição e analisados os atuais e futuros potenciais impactos na saúde associados com a exposição à poluição urbana. Neste âmbito, o modelo ExPOSITION (EXPOSure model to traffIc-relaTed aIr pOllutioN) foi desenvolvido baseado numa abordagem inovadora que envolve a análise da trajetória dos indivíduos recolhidas por telemóveis com tecnologia GPS e processadas através da abordagem de data mining e análise geoespacial. O modelo ExPOSITION considera também uma abordagem probabilística para caracterizar a variabilidade dos parâmetros microambientais e a sua contribuição para exposição individual. Adicionalmente, de forma a atingir os objetivos do estudo foi desenvolvido um novo módulo de cálculo de emissões de HAPs provenientes do transporte rodoviário. Neste estudo, um sistema de modelação, incluindo os modelos de transporteemissões- dispersão-exposição, foi aplicado na área urbana de Leiria para quantificação de exposição individual a PM2.5 e benzeno. Os resultados de modelação foram validados com base em medições obtidas por monitorização pessoal e monitorização biológica verificando-se uma boa concordância entre os resultados do modelo e dados de medições. A metodologia desenvolvida e implementada no âmbito deste trabalho permite analisar e estimar a magnitude, frequência e inter e intra-variabilidade dos níveis de exposição individual, bem como a contribuição de diferentes microambientes, considerando claramente a sequência de eventos de exposição e relação fonte-recetor, que é fundamental para avaliação dos efeitos na saúde e estudos epidemiológicos. O presente trabalho contribui para uma melhor compreensão da exposição individual em áreas urbanas, proporcionando novas perspetivas sobre a exposição individual, essenciais na seleção de estratégias de redução da exposição à poluição atmosférica urbana, e consequentes efeitos na saúde.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Although security plays an important role in the development of multiagent systems, a careful analysis of software development processes shows that the definition of security requirements is, usually, considered after the design of the system. One of the reasons is the fact that agent oriented software engineering methodologies have not integrated security concerns throughout their developing stages. The integration of security concerns during the whole range of the development stages can help towards the development of more secure multiagent systems. In this paper we introduce extensions to the Tropos methodology to enable it to model security concerns throughout the whole development process. A description of the new concepts and modelling activities is given along with a discussion on how these concepts and modelling activities are integrated to the current stages of Tropos. A real life case study from the health and social care sector is used to illustrate the approach.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An in situ experiment on a full-scale timber frame test building was carried out to study the hygrothermal performance of wood-hemp composite insulation in timber frame wall panels with and without a vapour barrier. The heat transfer properties and the likelihood of mould growth and condensation in the panels were compared. Step changes in the internal relative humidity were performed to explore the effects of high, normal and low internal moisture loads on the wall panels. No significant difference in the average equivalent thermal transmittance (U-values) between the panels with and without a vapour barrier was observed. The average equivalent U-values of the panels were close to the U-values calculated from the manufacturers’ declared thermal conductivity values of the insulation. The likelihood of condensation was higher at the interface of the wood-hemp insulation and the oriented strand board (OSB) in the panel without a vapour barrier. In terms of the parametric assessment of the mould germination potential, the relative humidity, the temperature and the exposure conditions in the insulation-OSB interfaces of the panel without a vapour barrier were found to be more favourable to the germination of mould spores. Nonetheless, when the insulations were dismantled, no mould was visually detected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An in situ experiment in a full scale timber frame test building was carried out to compare the hygrothermal performance of Hemp and Stone Wool insulations of identical thermal conductivity. Hemp and Stone Wool insulations were installed in timber frame wall panels without vapour barrier. The comparison was made in terms of heat transfer properties, likelihood of mould growth and condensation. Step changes in internal relative humidity were performed to explore the effect of high and normal internal moisture load on the wall panels. No significant difference between the average equivalent thermal transmittance (U-values) of the panels incorporating Hemp and Stone Wool insulations was observed. The average equivalent U-values of the panels were closer to the calculated U-values of the panels based on the manufacturers’ declared thermal conductivity of Hemp and Stone Wool insulations. It was observed that the placement of heat flux sensor along the depth of the insulation had significant influence on the measured equivalent U-value of the panels during high internal moisture load. The frequency and likelihood of condensation was higher in the interface of Stone Wool and Oriented Strand Board (OSB). In terms of the parametric assessment of mould germination potential, relative humidity, temperature and exposure conditions in the insulation-OSB interfaces were found to be favourable to germination of mould spore. However, when the insulations were dismantled, no mould was visually detected.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de dout., Ciências do Mar, Terra e Ambiente (Ecotoxicologia), Faculdade de Ciências e Tecnologia, Univ. do Algarve, 2012

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de doutoramento, Farmácia (Toxicologia), Universidade de Lisboa, Faculdade de Farmácia, 2014

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de doutoramento, Farmácia (Toxicologia), Universidade de Lisboa, Faculdade de Farmácia, 2015

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de doutoramento, Educação (Formação de Professores), Universidade de Lisboa, Instituto de Educação, 2015

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pollen is routinely monitored, but it is unknown whether pollen counts represent allergen exposure. We therefore simultaneously determined olive pollen and Ole e 1 in ambient air in C"ordoba, Spain, and "Evora, Portugal, using Hirst-type traps for pollen and high-volume cascade impactors for allergen. Pollen from different days released 12-fold different amounts of Ole e 1 per pollen (both locations P < 0.001). Average allergen release from pollen (pollen potency) was much higher in C"ordoba (3.9 pg Ole e 1/pollen) than in "Evora (0.8 pg Ole e 1/pollen, P = 0.004). Indeed, yearly olive pollen counts in C"ordoba were 2.4 times higher than in "Evora, but Ole e 1 concentrations were 7.6 times higher. When modeling the origin of the pollen, >40% of Ole e 1 exposure in "Evora was explained by high-potency pollen originating from the south of Spain. Thus, olive pollen can vary substantially in allergen release, even though they are morphologically identical.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Very few studies on human exposure to allergenic pollen have been conducted using direct methods, with background concentrations measured at city center monitoring stations typically taken as a proxy for exposure despite the inhomogeneous nature of atmospheric pollen concentrations. A 2003 World Health Organization report highlighted the need for an improved understanding of the relation between monitoring station data and actual exposure. Objective To investigate the relation between grass pollen dose and background concentrations measured at a monitoring station, to assess the fidelity of monitoring station data as a qualitative proxy for dose, and to evaluate the ratio of dose rate to background concentration. Methods Grass pollen dose data were collected in Aarhus, Denmark, in an area where grass pollen sources were prevalent, using Nasal Air Samplers. Sample collection lasted for approximately 25 to 30 minutes and was performed at 2-hour intervals from noon to midevening under moderate exercise by 2 individuals. Results A median ratio of dose rate to background concentration of 0.018 was recorded, with higher ratio values frequently occurring at 12 to 2 pm, the time of day when grass species likely to be present in the area are expected to flower. From 4 to 8 pm, dose rate and background concentration data were found to be strongly and significantly correlated (rs = 0.81). Averaged dose rate and background concentration data showed opposing temporal trends. Conclusion Where local emissions are not a factor, background concentration data constitute a good quantitative proxy for inhaled dose. The present ratio of dose rate to background concentration may aid the study of dose–response relations.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background. Ambrosia artemisiifolia L. is a noxious invasive alien species in Europe. It is an important aeroallergen and millions of people are exposed to its pollen. Objective. The main aim of this study is to show that atmospheric concentrations of Ambrosia pollen recorded in Denmark can be derived from local or more distant sources. Methods. This was achieved by using a combination of pollen measurements, air mass trajectory calculations using the HYPLIT model and mapping all known Ambrosia locations in Denmark and relating them to land cover types. Results. The annual pollen index recorded in Copenhagen during a 15-year period varied from a few pollen grains to more than 100. Since 2005, small quantities of Ambrosia pollen has been observed in the air every year. We have demonstrated, through a combination of Lagrangian back-trajectory calculations and atmospheric pollen measurements, that pollen arrived in Denmark via long-distance transport from centres of Ambrosia infection, such as the Pannonian Plain and Ukraine. Combining observations with results from a local scale dispersion model show that it is possible that Ambrosia pollen could be derived from local sources identified within Denmark. Conclusions. The high allergenic capacity of Ambrosia pollen means that only small amounts of pollen are relevant for allergy sufferers, and just a few plants will be sufficient to produce enough pollen to affect pollen allergy sufferers within a short distance from the source. It is necessary to adopt control measures to restrict Ambrosia numbers. Recommendations for the removal of all Ambrosia plants can effectively reduce the amount of local pollen, as long as the population of Ambrosia plants is small.