969 resultados para Optimized using


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Several attempts to determine the transit time of a high dose rate (HDR) brachytherapy unit have been reported in the literature with controversial results. The determination of the source speed is necessary to accurately calculate the transient dose in brachytherapy treatments. In these studies, only the average speed of the source was measured as a parameter for transit dose calculation, which does not account for the realistic movement of the source, and is therefore inaccurate for numerical simulations. The purpose of this work is to report the implementation and technical design of an optical fiber based detector to directly measure the instantaneous speed profile of a (192)Ir source in a Nucletron HDR brachytherapy unit. Methods: To accomplish this task, we have developed a setup that uses the Cerenkov light induced in optical fibers as a detection signal for the radiation source moving inside the HDR catheter. As the (192)Ir source travels between two optical fibers with known distance, the threshold of the induced signals are used to extract the transit time and thus the velocity. The high resolution of the detector enables the measurement of the transit time at short separation distance of the fibers, providing the instantaneous speed. Results: Accurate and high resolution speed profiles of the 192Ir radiation source traveling from the safe to the end of the catheter and between dwell positions are presented. The maximum and minimum velocities of the source were found to be 52.0 +/- 1.0 and 17.3 +/- 1:2 cm/s. The authors demonstrate that the radiation source follows a uniformly accelerated linear motion with acceleration of vertical bar a vertical bar = 113 cm/s(2). In addition, the authors compare the average speed measured using the optical fiber detector to those obtained in the literature, showing deviation up to 265%. Conclusions: To the best of the authors` knowledge, the authors directly measured for the first time the instantaneous speed profile of a radiation source in a HDR brachytherapy unit traveling from the unit safe to the end of the catheter and between interdwell distances. The method is feasible and accurate to implement on quality assurance tests and provides a unique database for efficient computational simulations of the transient dose. (C) 2010 American Association of Physicists in Medicine. [DOI: 10.1118/1.3483780]

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Conventional karyotyping detects anomalies in 3-15% of patients with multiple congenital anomalies and mental retardation (MCA/MR). Whole-genome array screening (WGAS) has been consistently suggested as the first choice diagnostic test for this group of patients, but it is very costly for large-scale use in developing countries. We evaluated the use of a combination of Multiplex Ligation-dependent Probe Amplification (MLPA) kits to increase the detection rate of chromosomal abnormalities in MCA/MR patients. We screened 261 MCA/MR patients with two subtelomeric and one microdeletion kits. This would theoretically detect up to 70% of all submicroscopic abnormalities. Additionally we scored the de Vries score for 209 patients in an effort to find a suitable cut-off for MLPA screening. Our results reveal that chromosomal abnormalities were present in 87 (33.3%) patients, but only 57 (21.8%) were considered causative. Karyotyping detected 15 abnormalities (6.9%), while MLPA identified 54 (20.7%). Our combined MLPA screening raised the total detection number of pathogenic imbalances more than three times when compared to conventional karyotyping. We also show that using the de Vries score as a cutoff for this screening would only be suitable under financial restrictions. A decision analytic model was constructed with three possible strategies: karyotype, karyotype + MLPA and karyotype + WGAS. Karyotype + MLPA strategy detected anomalies in 19.8% of cases which account for 76.45% of the expected yield for karyotype + WGAS. Incremental Cost Effectiveness Ratio (ICER) of MLPA is three times lower than that of WGAS, which means that, for the same costs, we have three additional diagnoses with MLPA but only one with WGAS. We list all causative alterations found, including rare findings, such as reciprocal duplications of regions deleted in Sotos and Williams-Beuren syndromes. We also describe imbalances that were considered polymorphisms or rare variants, such as the new SNP that confounded the analysis of the 22q13.3 deletion syndrome. (C) 2011 Elsevier Masson SAS. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim was to investigate inter-tester and intra-tester reliability and parallel reliability between a visual assessment method and a method using a pachymeter for locating the mid-point of the patella in determining the medial/lateral patella orientation. Fifteen asymptomatic subjects were assessed and the mid-point of the patella was determined by both methods on two separate occasions two weeks apart. Inter-tester reliability was obtained by ANOVA and by intraclass correlation coefficient (ICC); intra-tester reliability was obtained by a paired t-test and ICC; and parallel reliability was obtained by Pearson`s Correlation and ICC, for the measurement on the first and second evaluations. There was acceptable inter-tester agreement (p = 0.490) and reliability for the visual inspection (ICC = 0.747) and for the pachymeter (ICC = 0.716) at the second evaluation. The inter-tester reliability in the first evaluation was unacceptable (visual ICC = 0.604; pachymeter ICC = 0.612). Although there was statistical similarity between measurements for the first and second evaluations for all testers, intra-tester reliability was not acceptable for both methods: visual (examiner 1 ICC = 0.175; examiner 2 ICC = 0.189; examiner 3 ICC = 0.155) and pachymeter (examiner 1 ICC = 0.214; examiner 2 ICC = 0.246; examiner 3 ICC = 0.069). Parallel reliability gave a perfect correlation at the first evaluation (r=0.828; p<0.001) and at the second (r=0.756; p<0.001) and reliability was between acceptable and very good (ICC = [0.748-0.813]). Both visual and pachymeter methods provide reliable and similar medial/lateral patella orientation and are reliable between different examiners, but the results between the two assessments at 2 weeks` interval demonstrated an unacceptable reliability. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Recent advances in laparoscopic techniques have resulted in growing indications for laparoscopic hepatectomy. However, this procedure has not been widely developed, and anatomic segmental liver resection is not Currently performed due to difficulty controlling the segmental Glissonian pedicles laparoscopically. This study aimed to report a novel technique for laparoscopic anatomic resection of left liver segments using the intrahepatic Glissonian approach based on small incisions according to anatomic landmarks such as Arantius` and round ligaments. Methods Nine consecutive patients underwent laparoscopic liver resection using the intrahepatic Glissonian technique from April 2007 to June 2008. Five patients underwent laparoscopic bisegmentectomy 2-3, one laparoscopic left hemihepatectomy, two resections of segment 3, and one resection of segment 4. Results One patient required a blood transfusion. The mean operation time was 180 min (range, 120-300 min), and the median hospital stay was 3 days (range, 1-5 days). No patient had postoperative signs of liver failure or bile leakage. No postoperative mortality was observed. Conclusion The main advantage of the intrahepatic Glissonian procedure over other techniques is the possibility of gaining a rapid and precise access to the left Glissonian sheaths facilitating left hemihepatectomy, bisegmentectomy 2-3, and individual resections of segments 2, 3, and 4. The authors believe that the intrahepatic Glissonian technique facilitates laparoscopic liver resection and may increase the development of segment-based laparoscopic liver resection.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: Impulsivity is associated with the clinical outcome and likelihood of risky behaviors among bipolar disorder (BD) patients. Our previous study showed an inverse relationship between impulsivity and orbitofrontal cortex (OFC) volume in healthy subjects. We hypothesized that BD patients would show an inverse relationship between impulsivity and volumes of the OFC, anterior cingulate cortex (ACC), medial prefrontal cortex, and amygdala, which have been implicated in the pathophysiology of BD. Methods: Sixty-three BD patients were studied (mean +/- SD age = 38.2 +/- 11.5 years; 79% female). The Barratt Impulsiveness Scale (BIS), version 11A, was used to assess trait impulsivity. Images were processed using SPM2 and an optimized voxel-based morphometry protocol. We examined the correlations between BIS scores and the gray matter (GM) and white matter (WM) volumes of the prespecified regions. Results: Left rostral ACC GM volume was inversely correlated with the BIS total score (t = 3.95, p(corrected) = 0.003) and the BIS motor score (t = 5.22, p(corrected) < 0.001). In contrast to our hypothesis, OFC volumes were not significantly associated with impulsivity in BD. No WM volume of any structure was significantly correlated with impulsivity. No statistical association between any clinical variable and the rostral ACC GM volumes reached significance. Conclusions: Based on our previous findings and the current results, impulsivity may have a different neural representation in BD and healthy subjects, and the ACC may be involved in the pathophysiology of abnormal impulsivity regulation in BD patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The brain-derived neurotrophic factor (BDNF) Val66Met polymorphism has been proposed as a possible candidate for involvement in the pathophysiology of bipolar disorder ( BD). To determine whether an association exists between the BDNF Val66Met genotype and morphometric abnormalities of the brain regions involved in memory and learning in BD and healthy subjects. Forty-two BD patients and 42 healthy subjects were studied. Interactions between BDNF Val66Met genotype and diagnosis in gray ( GM) volumes were analyzed using an optimized voxel-based morphometry technique. Declarative memory function was assessed with the California Verbal Learning Test II. Left and right anterior cingulate GM volumes showed a significant interaction between genotype and diagnosis such that anterior cingulate GM volumes were significantly smaller in the Val/Met BD patients compared with the Val/Val BD patients (left P = 0.01, right P = 0.01). Within-group comparisons revealed that the Val/Met carriers showed smaller GM volumes of the dorsolateral prefrontal cortex compared with the Val/Val subjects within the BD patient (P = 0.01) and healthy groups (left P = 0.03, right P = 0.03). The Val/Met healthy subjects had smaller GM volumes of the left hippocampus compared with the Val/Val healthy subjects (P<0.01). There was a significant main effect of diagnosis on memory function (P = 0.04), but no interaction between diagnosis and genotype was found (P = 0.48). The findings support an association between the BDNF Val66Met genotype and differential gray matter content in brain structures, and suggest that the variation in this gene may play a more prominent role in brain structure differences in subjects affected with BD. Neuropsychopharmacology (2009) 34, 1904-1913; doi: 10.1038/npp.2009.23; published online 18 March 2009

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background Roux-en-Y gastric bypass (RYGB) is amongst the commonest surgical intervention for weight loss in obese patients. Gastrocutaneous fistula, which usually occurs along the vertical staple line of the pouch, is amongst its most alarming complications. Medical management comprised of wound drainage, nutritional support, acid suppression, and antibiotics may be ineffective in as many as a third of patients with this complication. We present outcomes after endoscopic application of SurgiSIS (R), which is a novel biomaterial for the treatment of this complication. Design A case series of 25 patients. Methods Twenty-five patients who had failed conservative medical management of gastrocutaneous fistula after RYGB underwent endoscopic application of SurgiSIS (R)-an acellular fibrogenic matrix biomaterial to help fistula healing. Main outcome measures Fistula closure as assessed by upper gastrointestinal imaging and endoscopic examination. Results In patients who had failed medical management lasting 4-25 (median, 7) weeks, closure of the fistulous tract was successful after one application in six patients (30%), two applications in 11 patients (55%), and three applications in three patients (15%). There were no procedure-related complications. Conclusions Endoscopic application of SurgiSIS (R)-an acellular fibrogenic matrix-is safe and effective for the treatment of gastrocutaneous fistula after RYGB.