982 resultados para Optical interferometric method
Resumo:
This study evaluated the effect of the C-factor and dentin preparation method (DPM) in the bond strength (BS) of a mild self-etch adhesive; the study also observed the SEM superficial aspects of the corresponding smear layer. For purposes of this study, 25 molars (n=5) were used in a bond strength test. The molars were divided into two parts (buccal and lingual): one part received a Class V cavity (C-factor=3) and the other received a flat surface (C-factor=0) with the same bur type (coarse diamond or carbide bur and fine diamond or carbide bur), both within the same dentin depth. Five teeth were prepared with wet 60-grit and 600-grit SiC papers. After restoration with Clearfil SE Bond, microtensile beans (0.8 mm(2)) were prepared and tested after 24 hours in a universal testing machine (0.5 mm/minute). An additional two teeth for each DPM were prepared for SEM evaluation of the smear layer superficial aspects. The BS values were submitted to one-way ANOVA, considering only the DPM (flat surfaces) and two-way ANOVA (C-Factor x DPM, considering only burs) with p=0.05. Although the DPM in the flat surfaces was not significant, the standard deviations of carbide bur-prepared specimens were markedly lower. The BS was significantly lower in cavities. The fine carbide bur presented the most favorable smear layer aspect. It was concluded that different dentin preparation methods could not prevent the adverse effect in bond strength of a high C-factor. A coarse cut carbide bur should be avoided prior to a mild self-etch adhesive, because it adversely affected bond strength. In contrast, a fine cut carbide bur provided the best combination: high bond strength with low variability, which suggests a more reliable bond strength performance.
Resumo:
The objective was to compare fracture toughness (K(Ic)), stress corrosion susceptibility coefficient (n), and stress intensity factor threshold for crack propagation (K(I0)) of two porcelains [VM7/Vita (V) and d.Sign/Ivoclar (D)], two glass-ceramics [Empress/Ivolcar (E1) and Empress2/Ivlocar (E2)] and a glass-infiltrated alumina composite [In-Ceram Alumina/Vita (IC)]. Disks were constructed according to each manufacturer`s processing method, and polished before induction of cracks by a Vickers indenter. Crack lengths were measured under optical microscopy at times between 0.1 and 100 h. Specimens were stored in artificial saliva at 37A degrees C during the whole experiment. K(Ic) and n were determined using indentation fracture method. K(I0) was determined by plotting log crack velocity versus log K(I). Microstructure characterization was carried out under SEM, EDS, X-ray diffraction and X-ray fluorescence. IC and E2 presented higher K(Ic) and K(I0) compared to E1, V, and D. IC presented the highest n value, followed by E2, D, E1, and V in a decreasing order. V and D presented similar K(Ic), but porcelain V showed higher K(I0) and lower n compared to D. Microstructure features (volume fraction, size, aspect ratio of crystalline phases and chemical composition of glassy matrix) determined K(Ic). The increase of K(Ic) value favored the increases of n and K(I0).
Resumo:
Purpose: The purpose of this study was to evaluate the amount of dentifrice applied to the toothbrush by school children using a liquid dentifrice (drop technique), when compared to toothpaste. Materials and Methods: A total of 178 school children (4-8 years old) from two cities in Brazil (Bauru and Bariri) participated in the present two-part crossover study. Children from Bauru received training regarding tooth-brushing techniques and use of dentifrice before data collection. In each phase, the amount of toothpaste or liquid dentifrice applied by the children to the toothbrush was measured, using a portable analytical balance (+/- 0.01 g). Data were tested by analysis of covariance (Ancova) and linear regression (p < 0.05). Results: The mean (+/- standard deviation) amounts of toothpaste and liquid dentifrice applied to the toothbrushes for children from Bauru were 0.41 +/- 0.20 g and 0.15 +/- 0.06 g, respectively. For children from Bariri, the amounts applied were and 0.48 +/- 0.24 g and 0.14 +/- 0.05 g, respectively. The amount of toothpaste applied was significantly larger than the amount of liquid dentifrice for both cities. Children from Bariri applied a significantly larger amount of toothpaste, when compared to those from Bauru. However, for the liquid dentifrice, there was no statistically significant difference between the cities. A significant correlation between the amount of toothpaste applied and the age of the children was verified, but the same was not found for the liquid dentifrice. Conclusion: The use of the drop technique reduced and standardised the amount of dentifrice applied to the toothbrush, which could reduce the risk of dental fluorosis for young children.
Resumo:
In this paper we present the composite Euler method for the strong solution of stochastic differential equations driven by d-dimensional Wiener processes. This method is a combination of the semi-implicit Euler method and the implicit Euler method. At each step either the semi-implicit Euler method or the implicit Euler method is used in order to obtain better stability properties. We give criteria for selecting the semi-implicit Euler method or the implicit Euler method. For the linear test equation, the convergence properties of the composite Euler method depend on the criteria for selecting the methods. Numerical results suggest that the convergence properties of the composite Euler method applied to nonlinear SDEs is the same as those applied to linear equations. The stability properties of the composite Euler method are shown to be far superior to those of the Euler methods, and numerical results show that the composite Euler method is a very promising method. (C) 2001 Elsevier Science B.V. All rights reserved.
Resumo:
The collection of spatial information to quantify changes to the state and condition of the environment is a fundamental component of conservation or sustainable utilization of tropical and subtropical forests, Age is an important structural attribute of old-growth forests influencing biological diversity in Australia eucalypt forests. Aerial photograph interpretation has traditionally been used for mapping the age and structure of forest stands. However this method is subjective and is not able to accurately capture fine to landscape scale variation necessary for ecological studies. Identification and mapping of fine to landscape scale vegetative structural attributes will allow the compilation of information associated with Montreal Process indicators lb and ld, which seek to determine linkages between age structure and the diversity and abundance of forest fauna populations. This project integrated measurements of structural attributes derived from a canopy-height elevation model with results from a geometrical-optical/spectral mixture analysis model to map forest age structure at a landscape scale. The availability of multiple-scale data allows the transfer of high-resolution attributes to landscape scale monitoring. Multispectral image data were obtained from a DMSV (Digital Multi-Spectral Video) sensor over St Mary's State Forest in Southeast Queensland, Australia. Local scene variance levels for different forest tapes calculated from the DMSV data were used to optimize the tree density and canopy size output in a geometric-optical model applied to a Landsat Thematic Mapper (TU) data set. Airborne laser scanner data obtained over the project area were used to calibrate a digital filter to extract tree heights from a digital elevation model that was derived from scanned colour stereopairs. The modelled estimates of tree height, crown size, and tree density were used to produce a decision-tree classification of forest successional stage at a landscape scale. The results obtained (72% accuracy), were limited in validation, but demonstrate potential for using the multi-scale methodology to provide spatial information for forestry policy objectives (ie., monitoring forest age structure).
Resumo:
P>Aim To evaluate by 3D profilometry and scanning electron microscopy (SEM), the marginal adaptation of mineral trioxide aggregate (MTA) and Sealer 26 placed in root-end cavities with direct vision or under an optical microscope. Methodology The root ends of 52 root filled canine teeth were filled with MTA or Sealer 26 under direct vision or optical microscope (n = 13). In each group, eight specimens were analysed by profilometry for measurement of the area and depth of gaps. In the other five specimens, gap area was measured using SEM to verify marginal adaptation and surface characteristic. Data were analysed by parametric (anova and Tukey) and non-parametric (Kruskal-Wallis and Dunn) tests. Results The assessment of the adaptation of both materials to dentine was not influenced by the mode of visualization, which was confirmed by both profilometry and SEM observations. The voids measured with profilometry for Sealer 26 under direct vision were significantly wider and deeper than those for MTA under direct vision (P < 0.05). In SEM, significantly larger gap areas were observed with Sealer 26 (P < 0.05). Conclusion Root-end cavities filled with MTA had smaller gaps and better marginal adaptation than Sealer 26.
Resumo:
This article discusses the design of a comprehensive evaluation of a community development programme for young people 'at-risk' of self-harming behaviour. It outlines considerations in the design of the evaluation and focuses on the complexities and difficulties associated with the evaluation of a community development programme. The challenge was to fulfil the needs of the funding body for a broad, outcome-focused evaluation while remaining close enough to the programme to accurately represent its activities and potential effects at a community level. Specifically, the strengths and limitations of a mixed-method evaluation plan are discussed with recommendations for future evaluation practice.
Resumo:
Spontaneous and tone-evoked changes in light reflectance were recorded from primary auditory cortex (A1) of anesthetized cats (barbiturate induction, ketamine maintenance). Spontaneous 0.1-Hz oscillations of reflectance of 540- and 690-nm light were recorded in quiet. Stimulation with tone pips evoked localized reflectance decreases at 540 nm in 3/10 cats. The distribution of patches activated by tones of different frequencies reflected the known tonotopic organization of auditory cortex. Stimulus-evoked reflectance changes at 690 nm were observed in 9/10 cats but lacked stimulus-dependent topography. In two experiments, stimulus-evoked optical signals at 540 nm were compared with multiunit responses to the same stimuli recorded at multiple sites. A significant correlation (P < 0.05) between magnitude of reflectance decrease and multiunit response strength was evident in only one of five stimulus conditions in each experiment. There was no significant correlation when data were pooled across all stimulus conditions in either experiment. In one experiment, the spatial distribution of activated patches, evident in records of spontaneous activity at 540 nm, was similar to that of patches activated by tonal stimuli. These results suggest that local cerebral blood volume changes reflect the gross tonotopic organization of A1 but are not restricted to the sites of spiking neurons.
Resumo:
A new wavelet-based method for solving population balance equations with simultaneous nucleation, growth and agglomeration is proposed, which uses wavelets to express the functions. The technique is very general, powerful and overcomes the crucial problems of numerical diffusion and stability that often characterize previous techniques in this area. It is also applicable to an arbitrary grid to control resolution and computational efficiency. The proposed technique has been tested for pure agglomeration, simultaneous nucleation and growth, and simultaneous growth and agglomeration. In all cases, the predicted and analytical particle size distributions are in excellent agreement. The presence of moving sharp fronts can be addressed without the prior investigation of the characteristics of the processes. (C) 2001 Published by Elsevier Science Ltd.
Resumo:
Rapid access to genetic information is central to the revolution presently occurring in the pharmaceutical industry, particularly In relation to novel drug target identification and drug development. Genetic variation, gene expression, gene function and gene structure are just some of the important research areas requiring efficient methods of DNA screening. Here, we highlight state-of-the-art techniques and devices for gene screening that promise cheaper and higher-throughput yields than currently achieved with DNA microarrays. We include an overview of existing and proposed bead-based strategies designed to dramatically increase the number of probes that can be interrogated in one assay. We focus, in particular, on the issue of encoding and/or decoding (bar-coding) large bead-based libraries for HTS.
Resumo:
When visual information is confined to one object plane, the emmetropization end-point is adjusted in accord with the corresponding incident optical vergence at the eye [Proceedings of the 7th International Conference on Myopia (2000) 113]. We now report the effect of adding extra visual information beyond the target plane. Visual conditions were controlled using a cone-lens system: black Maltese cross targets on white opaque backgrounds (OMX) were attached to the open faces of 2.5 cm translucent cones fitted with either 0, +25 or +40 D imaging lenses. An alternative target (TMX) was made by substituting the opaque target background for a transparent background, which allowed access to visual information beyond the target plane. The imaging devices were applied to 7-day-old chicks and worn for 4 days. Prior to this treatment, on day 2, some chicks underwent ciliary nerve section (CNS) to preclude accommodation. All treatments were monocular. Refractive errors and axial ocular dimensions were measured using retinoscopy and A-scan ultrasonography under halothane anesthesia. Treatment effects were specified as mean ( +/-S.D.) interocular differences. Eyes with the OMX/ + 40 D lens combination remained emmetropic ( +0.73 +/-3.57 D), consistent with the target plane being approximately conjugate with the retina. Switching to the TMX caused a hyperopic shift in refractive error ( + 3.78 +/- 3.41 D). This relative shift towards hyperopia in switching from the OMX to the TMX target also occurred for the other two lens powers. Thus, the OMX/ + 25 D lens induced myopia ( - 7.00 +/-5.88 D), corresponding to the imposed hyperopic defocus (target plane now imaged behind the retina), and switching to the TMX resulted in a reduction in myopia (-1.73 +/-5.36 D), The OMX/0 D lens combination produced the largest myopic shift, and here, switching to the TMX condition almost eliminated the myopic response (-15.50 +/-6.62 D cf. -0.56 +/-1.24 D). This relative hyperopic shift associated with switching from the OMX to the TMX target was eliminated by CNS surgery. Thus, the two CNS/TMX groups were both more myopic than the equivalent no CNS/TMX groups ( + 40 D lens: -2.66 +/-2.34 D; +25 D lens: -7.97 +/-6.87 D). When the visual information is restricted to one plane, incident optical vergence appears to direct emmetropization. Adding Visual information at other distances produces a shift in the end-point of ernmetropization in the direction of the added information. That these effects are dependent on the integrity of the accommodation system implies that accommodation plays a role in emmetropization and represents the first reported evidence of this kind. Published by Elsevier Science Ltd.
Resumo:
A flow tagging technique based upon ionic fluorescence in strontium is investigated for applications to velocity measurements in gas flows. The method is based upon a combination of two laser based spectroscopic techniques, i.e. resonantly-enhanced ionisation and laser-induced ionic fluorescence. Strontium is first ionised and then planar laser-induced fluorescence is utilised to give 2D 'bright images' of the ionised region of the flow at a given time delay. The results show that this method can be used for velocity measurements. The velocities were measured in two types of air-acetylene flames - a slot burner and a circular burner yielding velocities of 5.1 +/- 0.1 m/s and 9.3 +/- 0.2 m/s, respectively. The feasibility of the method for the determination of velocities in faster flows than those investigated here is discussed.