978 resultados para Non-thermal Plasma


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Purpose: The impact of acute weight loss on rowing performance was assessed when generous nutrient intake was provided in 2 h of recovery after making weight. Methods: Competitive rowers (N = 17) completed four ergometer trials, each separated by 48 h. Two trials were performed after a 4% body mass loss in the previous 24 h (WT) and two were performed after no weight restrictions, that is, unrestricted (UNR). In addition, two trials (I X WT, I X UNR) were in a thermoneutral environment (NEUTRAL, mean 21.1 +/- SD 0.7 degrees C, 29.0 +/- 4.5% RH) and two were in the heat (HOT 32.4, +/- 0.4 degrees C, 60.4 +/- 2.7% RH). Trials were performed in a counterbalanced fashion according to a Latin square design. Aggressive nutritional recovery strategies (WT 2.3 g(.)kg(-11) carbohydrate, 34 mg-kg(-1) Na, 28.4 mL(.)kg(-1) fluid; UNR ad libitum) were employed in the 2 h after weigh-in. Results: Both WT (mean 2.1, 95% CI 0.7-3.4 s; P = 0.003) and HOT (4.1, 2.7 - 5.4 s; P < 0.001) compromised 2000-m time-trial performance. Whereas WT resulted in hypohydration, the associated reduction in plasma volume explained only part of the performance compromise observed (0.2 s for every 1% decrement) Moreover, WT did not influence core temperature or indices of cardiovascular function. Conclusions: Acute weight loss compromised performance, despite generous nutrient intake in recovery, although the effect was small. Performance decrements were further exacerbated when exercise was performed in the heat.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

It is unclear whether a random plasma cortisol measurement and the corticotropin (ACTH) test adequately reflect glucocorticoid secretory capacity in critical illness. This study aimed to determine whether these tests provide information representative of the 24 hour period. Plasma cortisol was measured hourly for 24 hours in 21 critically ill septic patients followed by a corticotropin test with 1 μ g dose administered intravenously. Serum and urine were analysed for ACTH and free cortisol respectively. Marked hourly variability in plasma cortisol was evident (coefficient of variation 8-30%) with no demonstrable circadian rhythm. The individual mean plasma cortisol concentrations ranged from 286 59 nmol/l to 796 &PLUSMN; 83 nmol/l. The 24 hour mean plasma cortisol was strongly correlated with both random plasma cortisol (r(2) 0.9, P< 0.0001) and the cortisol response to corticotropin (r(2) 0.72, P< 0.001). Only nine percent of patients increased their plasma cortisol by 250 nmol/l after corticotropin (euadrenal response). However, 35% of non-responders had spontaneous hourly rises > 250 nmol/l thus highlighting the limitations of a single point corticotropin test. Urinary free cortisol was elevated (865&PLUSMN; 937 nmol) in both corticotropin responders and non-responders suggesting elevated plasma free cortisol. No significant relationship was demonstrable between plasma cortisol and ACTH. We conclude that although random cortisol measurements and the low dose corticotropin tests reliably reflect the 24 hour mean cortisol in critical illness, they do not take into account the pulsatile nature of cortisol secretion. Consequently, there is the potential for erroneous conclusions about adrenal function based on a single measurement. We suggest that caution be exercised when drawing conclusions on the adequacy of adrenal function based on a single random plasma cortisol or the corticotropin test.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Secretion of mucins and exudation of plasma are distinct processes of importance to innate immunity and inflammatory disease. Yet, little is known about their relation in human airways. The objective of the present study was to use the human nasal airway to determine mucinous secretion and plasma exudation in response to common challenge agents and mediators. Ten healthy volunteers were subjected to nasal challenge-lavage procedures. Thus, the nasal mucosa was exposed to increasing doses of histamine (40 and 400 mu g ml(-1)), methacholine (12.5 and 25 mg) and capsaicin (30 and 300 ng ml(-1)). Fucose was selected as a global marker of mucinous secretion and alpha(2)-macroglobulin as an index of exudation of bulk plasma. All challenge agents increased the mucosal output of fucose to about the same level (P < 0.01-0.05). Once significant secretion had been induced the subsequently increased dose of the challenge agent, in the case of histamine and methacholine, failed to further increase the response. Only histamine increased the mucosal output of alpha(2)-macroglobulin (P < 0.01). We conclude that prompt but potentially rapidly depleted mucinous secretion is common to different kinds of airway challenges, whereas inflammatory histamine-type mediators are required to produce plasma exudation. Along with the acknowledged secretion of mucins, a practically non-depletable, pluripotent mucosal output of plasma emerges as an important component of the innate immunity of human airways.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The synthesis, characterization and thermal behaviour of some new dimeric allylpalladium (II) complexes bridged by pyrazolate ligands are reported. The complexes [Pd(mu-3, 5-R'(2)pz)(eta(3)-CH2C(R)CH2)](2) [R = H; R'= CH(CH3)(2) (1a); R = H, R' = C(CH3)(3) (1b), R = H; R' = CF3 (1c); R = CH3, R' = CH(CH3)(2) (2a); R = CH3, R' = C(CH3)(3) (2b); and R = CH3, R' = CF3 (2c)] have been prepared by the room temperature reaction of [Pd(eta(3)-CH2C(R)CH2)(acac)](acac = acetylacetonate) with 3,5-disubstituted pyrazoles in acetonitrile solution. The complexes have been characterized by NMR (H-1, C-13{H-1}), FT-IR, and elemental analyses. The structure of a representative complex, viz. 2c, has been established by single-crystal X-ray diffraction. The dinuclear molecule features two formally square planar palladium centres which are bridged by two pyrazole ligands and the coordination of each metal centre is completed by allyl substituents. The molecule has non-crystallographic mirror symmetry. Thermogravimetric studies have been carried out to evaluate the thermal stability of these complexes. Most of the complexes thermally decompose in argon atmosphere to give nanocrystals of palladium, which have been characterized by XRD, SEM and TEM. However, complex 2c can be sublimed in vacuo at 2 mbar without decomposition. The equilibrium vapour pressure of 2c has been measured by the Knudsen effusion technique. The vapour pressure of the complex 2c could be expressed by the relation: In (p/Pa)(+/- 0.06) = -18047.3/T + 46.85. The enthalpy and entropy of vapourization are found to be 150.0 +/- 3 kJ mol(-1) and 389.5 +/- 8 J K-1 mol(-1), respectively. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Over the last 50 yr, thermal biology has shifted from a largely physiological science to a more integrated science of behavior, physiology, ecology, and evolution. Today, the mechanisms that underlie responses to environmental temperature are being scrutinized at levels ranging from genes to organisms. From these investigations, a theory of thermal adaptation has emerged that describes the evolution of thermoregulation, thermal sensitivity, and thermal acclimation. We review and integrate current models to form a conceptual model of coadaptation. We argue that major advances will require a quantitative theory of coadaptation that predicts which strategies should evolve in specific thermal environments. Simply combining current models, however, is insufficient to understand the responses of organisms to thermal heterogeneity; a theory of coadaptation must also consider the biotic interactions that influence the net benefits of behavioral and physiological strategies. Such a theory will be challenging to develop because each organism's perception of and response to thermal heterogeneity depends on its size, mobility, and life span. Despite the challenges facing thermal biologists, we have never been more pressed to explain the diversity of strategies that organisms use to cope with thermal heterogeneity and to predict the consequences of thermal change for the diversity of communities.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This paper describes a relatively simple and quick method for implementing aerodynamic heating models into a finite element code for non-linear transient thermal-structural and thermal-structural-vibrational analyses of a Mach 10 generic HyShot scramjet engine. The thermal-structural-vibrational response of the engine was studied for the descent trajectory from 60 to 26 km. Aerodynamic heating fluxes, as a function of spatial position and time for varying trajectory points, were implemented in the transient heat analysis. Additionally, the combined effect of varying dynamic pressure and thermal loads with altitude was considered. This aero-thermal-structural analysis capability was used to assess the temperature distribution, engine geometry distortion and yielding of the structural material due to aerodynamic heating during the descent trajectory, and for optimising the wall thickness, nose radius of leading edge, etc. of the engine intake. A structural vibration analysis was also performed following the aero-thermal-structural analysis to determine the changes in natural frequencies of the structural vibration modes that occur at the various temperatures associated with the descent trajectory. This analysis provides a unique and relatively simple design strategy for predicting and mitigating the thermal-structural-vibrational response of hypersonic engines. (C) 2006 Elsevier SAS. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Diets with more than 30 g K/kg DM have previously been associated with hypomagnesaemia in grazing cattle, and to test whether such diets lead to mineral disorders in sheep, the absorption of Mg and other elements was investigated using experimental diets to which KC I had been added to provide 27, 29, 32 or 34 g K/kg DM. The apparent absorption, balance and apparent retention of Mg, and to a lesser extent Ca, were reduced for sheep offered the diets with 32 or 34 g K/kg DM. The absorption and retention of K, Na, P, Zn, Pb and Cd was not affected by treatment. The blood intracellular Ca concentration was reduced by the diets with 29, 32 or 34 g K/kg DM, compared to the diet with 27 g K/kg DM, but the concentration of other elements was unaffected. Blood plasma Ca concentration was increased at the highest level of K inclusion, providing evidence of mild hyperkalaemia and the involvement of Ca homeostatic mechanisms. It is concluded that Mg absorption by sheep will be impaired if the diet contains more than 30 g K/kg DM, equivalent to an intake of approximately 13 g K/d, but that a high K diet may be beneficial before parturition to accustom the sheep to Ca mobilization before lactation. (c) 2005 Elsevier B.V. All rights reserved.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Introduction: Endothelin-1 is a potent vasoconstricting growth peptide. In physiologic conditions basal levels maintain vascular homeostasis, conversely in pathological situations it may be expressed in response to chronic and acute vascular injury. Elevated levels of plasma ET-1 have been identified in sub-populations at risk of ischaemic heart disease (IHD) including smokers, diabetics and hyerlipidaemic subjects and in patients with atherosclerotic disease. This peptide may be chronically expressed, such as in congestive heart failure where it has been used as a prognostic marker of disease severity and also acutely, after cardiac revascularisation surgery, possibly as a result of endothelial injury and ischaemia. Aims: The objectives of this study were to (1) identify basal endothelin-1 concentrations in a young healthy control group with no risk factors for IHD (control group 1); (2) to compare; (1) venous plasma ET-1 levels preoperatively and post-operatively in patients undergoing CABG surgery, (3) to compare pre-operative plasma ET-1 levels from the CABG group with an age and gender matched control group (control group 2) and (4) combine all three groups to assess correlations between plasma ET-1 and the various risk factors for IHD, including smoking, hypertension, hyperlipidemia, diabetes and family history. Methods: Venous specimens were collected in chilled EDTA tubes and samples measured using an ELISA assay (Biomedica), following the standard protocol for human EDTA plasma. Results: Forty CABG patients (5F, 35M, mean age 66 yrs), 15 control group 1 subjects (8F, 7M, mean age 29 yrs) and 30 control group 2 subjects (5F, 25M, mean age 61 yrs) participated in the study. No significant difference was detected in plasma ET-1 levels between the controls (1) and (2), and the CABG group, where plasma ET-1 levels were 3.37+/ 5.19 pmol/L, 1.99+/3.74 pmol/L and 1.28+/1.27 pmol/L, respectively. There was a non-significant elevation in post-op ET-1 plasma in comparison with the pre-op levels (2.50+/0.51 Vs 1.45+/6.44). There were also no statistical correlation between risk factors for IHD including smoking, hypertension, NIDDM, hyperlipidemia or family history when data from both patient and controls groups was merged. Conclusion: Contrary to other findings, plasma ET-1 does not appear to a valid marker for IHD or factors which are strongly associated with the pathogenesis of this disease.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Aqueous semi-solid polymeric gels, such as those based on hydroxyethylcellulose (HEC) and polyacrylic acid (e.g. Carbopol®), have a long history of use in vaginal drug delivery. However, despite their ubiquity, they often provide sub-optimal clinical performance, due to poor mucosal retention and limited solubility for poorly water-soluble actives. These issues are particularly pertinent for vaginal HIV microbicides, since many lead candidates are poorly water-soluble and where a major goal is the development of a coitally independent, once daily gel product. In this study, we report the use of a non-aqueous silicone elastomer gel for vaginal delivery of the HIV-1 entry inhibitor maraviroc. In vitro rheological, syringeability and retention studies demonstrated enhanced performance for silicone gels compared with a conventional aqueous HEC gel, while testing of the gels in the slug model confirmed a lack of mucosal irritancy. Pharmacokinetic studies following single dose vaginal administration of a maraviroc silicone gel in rhesus macaques showed higher and sustained MVC levels in vaginal fluid, vaginal tissue and plasma compared with a HEC gel containing the same maraviroc loading. The results demonstrate that non-aqueous silicone gels have potential as a formulation platform for coitally independent vaginal HIV microbicides.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effect of low energy nitrogen molecular ion beam bombardment on metals and compound semiconductors has been studied, with the aim to investigate at the effects of ion and target properties. For this purpose, nitrogen ion implantation in aluminium, iron, copper, gold, GaAs and AIGaAs is studied using XPS and Angle Resolve XPS. A series of experimental studies on N+2 bombardment induced compositional changes, especially the amount of nitrogen retained in the target, were accomplished. Both monoenergetic implantation and non-monoenergetic ion implantation were investigated, using the VG Scientific ESCALAB 200D system and a d. c. plasma cell, respectively. When the samples, with the exception of gold, are exposed to air, native oxide layers are formed on the surfaces. In the case of monoenergetic implantation, the surfaces were cleaned using Ar+ beam bombardment prior to implantation. The materials were then bombarded with N2+ beam and eight sets of successful experiments were performed on each sample, using a rastered N2+ ion beam of energy of 2, 3, 4 and 5 keV with current densities of 1 μA/cm2 and 5 μA/cm22 for each energy. The bombarded samples were examined by ARXPS. After each complete implantation, XPS depth profiles were created using Ar+ beam at energy 2 ke V and current density 2 μA/cm2 . As the current density was chosen as one of the parameters, accurate determination of current density was very important. In the case of glow discharge, two sets of successful experiments were performed in each case, by exposing the samples to nitrogen plasma for the two conditions: at low pressure and high voltage and high pressure and low voltage. These samples were then examined by ARXPS. On the theoretical side, the major problem was prediction of the number of ions of an element that can be implanted in a given matrix. Although the programme is essentially on experimental study, but an attempt is being made to understand the current theoretical models, such as SATVAL, SUSPRE and TRIM. The experimental results were compared with theoretical predictions, in order to gain a better understanding of the mechanisms responsible. From the experimental results, considering possible experimental uncertainties, there is no evidence of significant variation in nitrogen saturation concentration with ion energy or ion current density in the range of 2-5 ke V, however, the retention characteristics of implantant seem to strongly depend on the chemical reactivity between ion species and target material. The experimental data suggests the presence of at least one thermal process. The discrepancy between the theoretical and experimental results could be the inability of the codes to account for molecular ion impact and thermal processes.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Plasma or "dry" etching is an essential process for the production of modern microelectronic circuits. However, despite intensive research, many aspects of the etch process are not fully understood. The results of studies of the plasma etching of Si and Si02 in fluorine-containing discharges, and the complementary technique of plasma polymerisation are presented in this thesis. Optical emission spectroscopy with argon actinometry was used as the principle plasma diagnostic. Statistical experimental design was used to model and compare Si and Si02 etch rates in CF4 and SF6 discharges as a function of flow, pressure and power. Etch mechanisms m both systems, including the potential reduction of Si etch rates in CF4 due to fluorocarbon polymer formation, are discussed. Si etch rates in CF4 /SF6 mixtures were successfully accounted for by the models produced. Si etch rates in CF4/C2F6 and CHF3 as a function of the addition of oxygen-containing additives (02, N20 and CO2) are shown to be consistent with a simple competition between F, 0 and CFx species for Si surface sites. For the range of conditions studied, Si02 etch rates were not dependent on F-atom concentration, but the presence of fluorine was essential in order to achieve significant etch rates. The influence of a wide range of electrode materials on the etch rate of Si and Si02 in CF4 and CF4 /02 plasmas was studied. It was found that the Si etch rate in a CF4 plasma was considerably enhanced, relative to an anodised aluminium electrode, in the presence of soda glass or sodium or potassium "doped" quartz. The effect was even more pronounced in a CF4 /02 discharge. In the latter system lead and copper electrodes also enhanced the Si etch rate. These results could not be accounted for by a corresponding rise in atomic fluorine concentration. Three possible etch enhancement mechanisms are discussed. Fluorocarbon polymer deposition was studied, both because of its relevance to etch mechanisms and its intrinsic interest, as a function of fluorocarbon source gas (CF4, C2F6, C3F8 and CHF3), process time, RF power and percentage hydrogen addition. Gas phase concentrations of F, H and CF2 were measured by optical emission spectroscopy, and the resultant polymer structure determined by X-ray photoelectron spectroscopy and infrared spectroscopy. Thermal and electrical properties were measured also. Hydrogen additions are shown to have a dominant role in determining deposition rate and polymer composition. A qualitative description of the polymer growth mechanism is presented which accounts for both changes in growth rate and structure, and leads to an empirical deposition rate model.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

High velocity oxyfuel (HVOF) thermal spraying is one of the most significant developments in the thermal spray industry since the development of the original plasma spray technique. The first investigation deals with the combustion and discrete particle models within the general purpose commercial CFD code FLUENT to solve the combustion of kerosene and couple the motion of fuel droplets with the gas flow dynamics in a Lagrangian fashion. The effects of liquid fuel droplets on the thermodynamics of the combusting gas flow are examined thoroughly showing that combustion process of kerosene is independent on the initial fuel droplet sizes. The second analysis copes with the full water cooling numerical model, which can assist on thermal performance optimisation or to determine the best method for heat removal without the cost of building physical prototypes. The numerical results indicate that the water flow rate and direction has noticeable influence on the cooling efficiency but no noticeable effect on the gas flow dynamics within the thermal spraying gun. The third investigation deals with the development and implementation of discrete phase particle models. The results indicate that most powder particles are not melted upon hitting the substrate to be coated. The oxidation model confirms that HVOF guns can produce metallic coating with low oxidation within the typical standing-off distance about 30cm. Physical properties such as porosity, microstructure, surface roughness and adhesion strength of coatings produced by droplet deposition in a thermal spray process are determined to a large extent by the dynamics of deformation and solidification of the particles impinging on the substrate. Therefore, is one of the objectives of this study to present a complete numerical model of droplet impact and solidification. The modelling results show that solidification of droplets is significantly affected by the thermal contact resistance/substrate surface roughness.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This thesis reports on the development of a technique to evaluate hydraulic conductivities in a soil (Snowcal) subject to freezing conditions. The technique draws on three distinctly different disciplines, Nuclear Physics, Soil Physics and Remote Sensing to provide a non-destructive and reliable evaluation of hydraulic conductivity throughout a freezing test. Thermal neutron radiography is used to provide information on local water/ice contents at anytime throughout the test. The experimental test rig is designed so that the soil matrix can be radiated by a neutron beam, from a nuclear reactor, to obtain radiographs. The radiographs can then be interpreted, following a process of remote sensing image enhancement, to yield information on relative water/ice contents. Interpretation of the radiographs is accommodated using image analysis equipment capable of distinguishing between 256 shades of grey. Remote sensing image enhancing techniques are then employed to develop false colour images which show the movement of water and development of ice lenses in the soil. Instrumentation is incorporated in the soil in the form of psychrometer/thermocouples, to record water potential, electrical resistance probes to enable ice and water to be differentiated on the radiographs and thermocouples to record the temperature gradient. Water content determinations are made from the enhanced images and plotted against potential measurements to provide the moisture characteristic for the soil. With relevant mathematical theory pore water distributions are obtained and combined with water content data to give hydraulic conductivities. The values for hydraulic conductivity in the saturated soil and at the frozen fringe are compared with established values for silts and silty-sands. The values are in general agreement and, with refinement, this non-destructive technique could afford useful information on a whole range of soils. The technique is of value over other methods because ice lenses are actually seen forming in the soil, supporting the accepted theories of frost action. There are economic and experimental restraints to the work which are associated with the use of a nuclear facility, however, the technique is versatile and has been applied to the study of moisture transfer in porous building materials and could be further developed into other research areas.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this paper we examine the equilibrium states of periodic finite amplitude flow in a horizontal channel with differential heating between the two rigid boundaries. The solutions to the Navier-Stokes equations are obtained by means of a perturbation method for evaluating the Landau coefficients and through a Newton-Raphson iterative method that results from the Fourier expansion of the solutions that bifurcate above the linear stability threshold of infini- tesimal disturbances. The results obtained from these two different methods of evaluating the convective flow are compared in the neighbourhood of the critical Rayleigh number. We find that for small Prandtl numbers the discrepancy of the two methods is noticeable.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The effect of stainless steel, glass, zirconium and titanium enamel surfaces on the thermal and photooxidative toughening mechanism of dehydrated castor oil films deposited on these surfaces was investigated using different analytical and spectroscopic methods. The conjugated and non-conjugated double bonds were identified and quantified using both Raman spectroscopy and 1D and 2D NMR spectroscopy. The disappearance of the double bonds in thermally oxidised oil-on-surface films was shown to be concomitant with the formation of hydroperoxides (determined by iodometric titration). The type of the surface had a major effect on the rate of thermal oxidation of the oil, but all of the surfaces examined had resulted in a significantly higher rate of oxidation compared to that of the neat oil. The highest effect was exhibited by the stainless steel surface followed by zirconium enamel, titanium enamel and glass. The rate of thermal oxidation of the oil-on-steel surface (at 100 °C, based on peroxide values) was more than five times faster than that of oil-on-glass and more than 21 times faster than the neat oil when compared under similar thermal oxidative conditions. The rate of photooxidation at 60 °C of oil-on-steel films was found to be about one and half times faster than their rate of thermal oxidation at the same temperature. Results from absorbance reflectance infrared microscopy with line scans taken across the depth of thermally oxidised oil-on-steel films suggest that the thermal oxidative toughening mechanism of the oil occurs by two different reaction pathways with the film outermost layers, i.e. furthest away from the steel surface, oxidising through a traditional free radical oxidation process involving the formation of various oxygenated products formed from the decomposition of allylic hydroperoxides, whereas, in the deeper layers closer to the steel surface, crosslinking reactions predominate.