991 resultados para Micro Tomography
Resumo:
After digestion of infected meat the free L1 of Trichinella spp. penetrate the intestinal mucosa where they moult to the mature adult stage. We have used proteomics to identify changes in protein secretion during in vitro culture of free T. spiralis muscle larvae under different environmental conditions, and to correlate these changes with their infectivity in mice. Muscle larvae were cultured in different media (RPMI-1640, C-199 and HBSS) under conditions of anaerobiosis, microaerobiosis and in 5% CO(2) at 37 degrees C. Following incubation the larval excretory/secretory proteins were analysed by two-dimensional gel electrophoresis and the larvae were used to orally infect naïve CD1 mice. For all culture media tested, infectivity of the L1 was preserved following incubation in anaerobic conditions. In contrast, the infectivity of worms cultured in nutrient-rich media was almost completely abolished in both microaerobiosis and in the presence of 5% CO(2). Some infectivity was retained in poor or reduced culture media. Comparative analysis of larval infectivity and protein secretion showed that loss of infectivity correlated with the appearance of non-tyvelosylated proteins that in turn may be related to the onset of moulting.
Resumo:
The concentrations of a range of micro-organic compounds in the Humber rivers have been measured at weekly intervals over a period of 1 year. The compounds include the triazine herbicides (simazine, atrazine, propazine, desmetryn and prometryn), selected organophosphorus insecticides (fenitrothion, malathion and parathion), phenylurea (chlorotoluron, diuron, isoproturon and linuron) and phenoxyacid herbicides (2,4-D, MCPA, MCPB and mecoprop), phenol derivatives (phenol, 2-ethylphenol, 2-chlorophenol, 4-nitrophenol, 2-methylphenol, 4-ethylphenol and 2,4-dichlorophenol), organochlorine insecticides (HEOD, DDT, TDE, DDE, HCB, alpha-BHC and lindane), PCB's and some synthetic pyrethroid insecticides (cis/trans-permethrin, fenvalerate and cypermethrin). The results indicate the high frequency of occurrence of many compounds in the southern Humber rivers Aire, Calder, Trent and Don compared with the more occasional concentrations found in the upland rivers with catchments dominated by low intensity agriculture. The more water soluble herbicides, atrazine, simazine, isoproturon and diuron are detected frequently in the southern rivers with the highest concentrations and abundance in the rivers Aire, Calder and Trent. The most abundant phenolic compound is 2,4-dichlorophenol usually occurring at concentrations <1 mu g/l. The organochlorine insecticides and PCB's are generally at concentrations <0.01 mu g/l, cis/trans-permethrin are the only synthetic pyrethroids detected and these are found in the rivers Aire and Calder at about equal concentrations of between 0.01 and 0.11 mu g/l. The results of the occurrence of simazine and atrazine in the rivers Trent, Don and Aire illustrate peaks in concentration in the spring and then later in the year during the early autumn coinciding with the first major storm after the summer. In the rivers Trent and Don, the annual exports (March 1994-95) of atrazine are lower than for simazine whereas in the R. Calder the yield of atrazine is higher than for simazine suggesting differences in use in these catchments. The maximum triazine concentration observed, i.e. 8 mu g/l of atrazine in the R. Calder, could have inhibiting effects on the phytoplankton and algal growth, although because of the transient nature of the peaks, recovery is expected to be rapid. The only other compounds measured at concentrations likely to produce detrimental ecotoxicological effects are cis/trans permethrin in the rivers Aire and Calder. (C) 1997 Elsevier Science B.V.
Resumo:
Gas-liquid processing in microreactors remains mostly restricted to the laboratory scale due to the complexity and expenditure needed for an adequate numbering-up with a uniform flow distribution. Here, the numbering-up is presented for multi-phase (gas-liquid) flow in microreactor suitable for a production capacity of kg/h. Based on the barrier channels concept, the barrier-based micro/milli reactor (BMMR) is designed and fabricated to deliver flow non-uniformity of less than 10%. The BMMR consists of eight parallel channels all operated in the Taylor flow regime and with a liquid flow rate up to 150. mL/min. The quality of the flow distribution is reported by studying two aspects. The first aspect is the influence of different viscosities, surface tensions and flow rates. The second aspect is the influence of modularity by testing three different reaction channels type: (1) square channels fabricated in a stainless steel plate, (2) square channels fabricated in a glass plate, and (3) circular channels (capillaries) made of stainless steel. Additionally, the BMMR is compared to that of a single channel regard the slug and bubble lengths and bubble generation frequency. The results pave the ground for bringing multi-phase flow in microreactor one step closer for large scale production via numbering-up. © 2012 Elsevier B.V.
Resumo:
Near-infrared diffuse tomography was used in order to observe dynamic behaviour of flowing gases by measuring the 3D distributions of composition and temperature in a weakly scattering packed bed reactor, subject to wall effects and non-isothermal conditions. The technique was applied to the vapour phase hydrogen isotopic exchange reaction in a hydrophobic packing of low aspect ratio made of platinum on styrene divinyl benzene sulphonate copolymer resin. The results of tomography revealed uneven temperature and composition maps of water and deuterated water vapours in the core-packed bed and in the vicinity of the wall owing to flow maldistribution. The dynamic lag between the near-wall water vapour and deuterated water vapour compositions were observed suggesting that the convective transfer which was significant near the wall at the start, owing to high porosity, was also effective at large conversions. (C) 2012 Elsevier B.V. All rights reserved.
Resumo:
This paper proposes an optimisation of the adaptive Gaussian mixture background model that allows the deployment of the method on processors with low memory capacity. The effect of the granularity of the Gaussian mean-value and variance in an integer-based implementation is investigated and novel updating rules of the mixture weights are described. Based on the proposed framework, an implementation for a very low power consumption micro-controller is presented. Results show that the proposed method operates in real time on the micro-controller and has similar performance to the original model. © 2012 Springer-Verlag.
Resumo:
Aims - To study the interchangeability of the measurements of the optic disc topography obtained by one computerised image analyser and one confocal laser tomographic scanner. Methods - One eye of 28 patients with glaucoma or glaucoma suspects was studied. All cases had simultaneous stereoscopic disc photographs taken with the fundus camera Topcon TRC-SS and optic disc examination with the Heidelberg retina tomograph (HRT) during the same visit. The optic disc photographs were digitised and analysed with the Topcon ImageNet (TI) system. Three variables of the optic disc topography provided by the TI and the HRT were compared - cup volume (CV), rim area (RA), and cup area to disc area ratio (CA/DA). Results - The mean values of CV and RA provided by the TI (0.52 (SD 0.32) mm and 1.58 (0.39) mm , respectively) were greater (p <0.01) than the mean values of CV and RA determined by the HRT (0.32 (0.25) mm , and 1.33 (0.47) mm , respectively). The mean value of CA/DA provided by the TI (0.42 (0.14)) and the HRT (0.42 (0.18)) was similar (p = 0.93). Correlation coefficients between measurements obtained by the two methods ranged from 0.53 to 0.73. Conclusion - There was a significant discrepancy in the measurements of rim area and cup volume of the optic disc obtained by a computerised image analyser and a laser scanning tomograph.
Resumo:
Objective: To evaluate the quality of reporting of diagnostic accuracy studies using optical coherence tomography (OCT) in glaucoma. Design: Descriptive series of published studies. Participants: Published studies reporting a measure of the diagnostic accuracy of OCT for glaucoma. Methods: Review of English language papers reporting measures of diagnostic accuracy of OCT for glaucoma. Papers were identified from a Medline literature search performed in June 2006. Articles were appraised using the 25 items provided by the Standards for Reporting of Diagnostic Accuracy (STARD) initiative. Each item was recorded as full, partially, or not reported. Main Outcome Measures: Degree of compliance with the STARD guidelines. Results: Thirty papers were appraised. Eight papers (26.7%) fully reported more than half of the STARD items. The lowest number of fully reported items in a study was 5 and the highest was 17. Descriptions of key aspects of methodology frequently were missing. For example, details of participant sampling (e.g., consecutive or random selection) were described in only 8 (26.7%) of 30 publications. Measures of statistical uncertainty were reported in 18 (60%) of 30 publications. No single STARD item was fully reported by all the papers. Conclusions: The standard of reporting of diagnostic accuracy studies in glaucoma using OCT was suboptimal. It is hoped that adoption of the STARD guidelines will lead to an improvement in reporting of diagnostic accuracy studies, enabling clearer evidence to be produced for the usefulness of OCT for the diagnosis of glaucoma. © 2007 American Academy of Ophthalmology.
Resumo:
Animal communities are sensitive to environmental disturbance, and several multivariate methods have recently been developed to detect changes in community structure. The complex taxonomy of soil invertebrates constrains the use of the community level in monitoring environmental changes, since species identification requires expertise and time. However, recent literature data on marine communities indicate that little multivariate information is lost in the taxonomic aggregation of species data to high rank taxa. In the present paper, this hypothesis was tested on two oribatid mite (oribatida, Acari) assemblages under two different kinds of disturbance: metal pollution and fires. Results indicate that data sets built at the genus and family systematic rank can detect the effects of disturbance with little loss of information. This is an encouraging result in view of the use of the community level as a preliminary tool for describing patterns of human-disturbed soil ecosystems. (c) 2006 Elsevier SAS. All rights reserved.
Resumo:
Millipede gut microbiology and decomposition of faecal pellets over a period of eight weeks were studied in the laboratory. Bacterial numbers, carbon and nitrogen content, pH and weight loss were monitored. Heterotrophic bacteria were the most abundant and reached a peak in the first two weeks of decomposition. The amount of carbon was constant while ammonium nitrogen decreased from 1.51 % to 0.03 % after eight weeksThe pH of the pellets was slightly acidic and did not change much during the course of decomposition. A succession of micro-organisms was observed on decomposing pellets. Zygomycetes were replaced by Ascomycetes after 20 days of decomposition. Decomposition was significantly affected by temperature. The rate of decomposition was highest at 35[degree]C .
Resumo:
Tissue micro array (TMA) is based on the idea of applying miniaturization and a high throughput approach to hybridization-based analyses of tissues. It facilitates biomedical research on a large scale in a single experiment; thus representing one of the most commonly used technologies in translational research. A critical analysis of the existing TMA instruments indicates that there are potential constraints in terms of portability, apart from costs and complexity. This paper will present the development of an affordable, configurable, and portable TMA instrument to allow an efficient collection of tissues, especially in instrument-to-tissue scenarios. The purely mechanical instrument requires no energy sources other than the user, is light weight, portable, and simple to use. [DOI: 10.1115/1.4004922]
Resumo:
More than 200 known diseases are transmitted via foods or food products. In the United States, food-borne diseases are responsible for 76 million cases of illness, 32,500 cases of hospitalisation and 5000 cases of death yearly. The ongoing increase in worldwide trade in livestock, food, and food products in combination with increase in human mobility (business- and leisure travel, emigration etc.) will increase the risk of emergence and spreading of such pathogens. There is therefore an urgent need for development of rapid, efficient and reliable methods for detection and identification of such pathogens.
Microchipfabrication has had a major impact on electronics and is expected to have an equally pronounced effect on life sciences. By combining micro-fluidics with micromechanics, micro-optics, and microelectronics, systems can be realized to perform complete chemical or biochemical analyses. These socalled ’Lab-on-a-Chip’ will completely change the face of laboratories in the future where smaller, fully automated devices will be able to perform assays faster, more accurately, and at a lower cost than equipment of today. A general introduction of food safety and applied micro-nanotechnology in life sciences will be given. In addition, examples of DNA micro arrays, micro fabricated integrated PCR chips and total integrated lab-on-achip systems from different National and EU research projects being carried out at the Laboratory of Applied Micro- Nanotechnology (LAMINATE) group at the National Veterinary Institute (DTU-Vet) Technical University of Denmark and the BioLabchip group at the Department of Micro and Nanotechnology (DTU-Nanotech), Technical University of Denmark (DTU), Ikerlan-IK4 (Spain) and other 16 partners from different European countries will be presented.
Resumo:
This paper discusses the application of the Taguchi experimental design approach in optimizing the key process parameters for micro-welding of thin AISI 316L foil using the 100W CW fibre laser. A L16 Taguchi experiment was conducted to systematically understand how the power, scanning velocity, focus position, gas flow rate and type of shielding gas affect the bead dimensions. The welds produced in the L16 Taguchi experiment was mainly of austenite cellular-dendrite structure with an average grain size of 5µm. An exact penetration weld with the largest penetration to fusion width ratio was obtained. Among those process parameters, the interaction between power and scanning velocity presented the strongest effect to the penetration to fusion width ratio and the power was found to be the predominantly important factor that drives the interaction with other factors to appreciably affect the bead dimensions.