979 resultados para MOSSBAUER-SPECTRA
Resumo:
The organotin(IV) compounds [Me2Sn(L)(2)] (1), [Et(2)sn(L)(2)] (2), [(Bu2Sn)-Bu-n(L)(2)] (3), [(n)Oct(2)Sn(L)(2)] (4), [Ph2Sn(L)(2)] (5), and [PhOSnL](6) (6) have been synthesized from the reactions of 1-(4-chlorophenyl)-1-cyclopentanecarboxylic acid (HL) with the corresponding diorganotin(IV) oxide or dichloride. They were characterized by IR and multinuclear NMR spectroscopies, elemental analysis, cyclic voltammetry, and, for 2, 3, 4 and 6, single crystal X-ray diffraction analysis. While 1-5 are mononuclear diorganotin (IV) compounds, the X-ray diffraction of 6 discloses a hexameric drumlike structure with a prismatic Sn6O6 core. All these complexes undergo irreversible reductions and were screened for their in vitro antitumor activities toward HL-60, BGC-823, Bel-7402, and KB human cancer cell lines. Within the mononuclear compounds, the most active ones (3, 5) are easiest to reduce (least cathodic reduction potentials), while the least active ones (1, 4) are the most difficult to reduce. Structural rearrangements (i.e., Sn-O bond cleavages and trans-to-cis isomerization) induced by reduction, which eventually can favor the bioactivity, are disclosed by theoretical/electrochemical studies.
Resumo:
Five new silver(I) complexes of formulas [Ag(Tpms)] (1), [Ag(Tpms)-(PPh3)] (2), [Ag(Tpms)(PCy3)] (3), [Ag(PTA)][BF4] (4), and [Ag(Tpms)(PTA)] (5) {Tpms = tris(pyrazol-1-yl)methanesulfonate, PPh3 = triphenylphosphane, PCy3 = tricyclohexylphosphane, PTA = 1,3,5-triaza-7-phosphaadamantane) have been synthesized and fully characterized by elemental analyses, H-1, C-13, and P-31 NMR, electrospray ionization mass spectrometry (ESI-MS), and IR spectroscopic techniques. The single crystal X-ray diffraction study of 3 shows the Tpms ligand acting in the N-3-facially coordinating mode, while in 2 and 5 a N2O-coordination is found, with the SO3 group bonded to silver and a pendant free pyrazolyl ring. Features of the tilting in the coordinated pyrazolyl rings in these cases suggest that this inequivalence is related with the cone angles of the phosphanes. A detailed study of antimycobacterial and antiproliferative properties of all compounds has been carried out. They were screened for their in vitro antimicrobial activities against the standard strains Enterococcus faecalis (ATCC 29922), Staphylococcus aureus (ATCC 25923), Streptococcus pneumoniae (ATCC 49619), Streptococcus pyogenes (SF37), Streptococcus sanguinis (SK36), Streptococcus mutans (UA1S9), Escherichia coli (ATCC 25922), and the fungus Candida albicans (ATCC 24443). Complexes 1-5 have been found to display effective antimicrobial activity against the series of bacteria and fungi, and some of them are potential candidates for antiseptic or disinfectant drugs. Interaction of Ag complexes with deoxyribonucleic acid (DNA) has been studied by fluorescence spectroscopic techniques, using ethidium bromide (EB) as a fluorescence probe of DNA. The decrease in the fluorescence of DNA EB system on addition of Ag complexes shows that the fluorescence quenching of DNA EB complex occurs and compound 3 is particularly active. Complexes 1-5 exhibit pronounced antiproliferative activity against human malignant melanoma (A375) with an activity often higher than that of AgNO3, which has been used as a control, following the same order of activity inhibition on DNA, i.e., 3 > 2 > 1 > 5 > AgNO3 >> 4.
Resumo:
Copyright © 2010 Elsevier B.V. All rights reserved.
Resumo:
Glucose sensing is an issue with great interest in medical and biological applications. One possible approach to glucose detection takes advantage of measuring changes in fluorescence resonance energy transfer (FRET) between a fluorescent donor and an acceptor within a protein which undergoes glucose-induced changes in conformation. This demands the detection of fluorescent signals in the visible spectrum. In this paper we analyzed the emission spectrum obtained from fluorescent labels attached to a protein which changes its conformation in the presence of glucose using a commercial spectrofluorometer. Different glucose nanosensors were used to measure the output spectra with fluorescent signals located at the cyan and yellow bands of the spectrum. A new device is presented based on multilayered a-SiC:H heterostructures to detect identical transient visible signals. The transducer consists of a p-i'(a-SiC:H)-n/p-i(a-Si:H)-n heterostructure optimized for the detection of the fluorescence resonance energy transfer between fluorophores with excitation in the violet (400 nm) and emissions in the cyan (470 nm) and yellow (588 nm) range of the spectrum. Results show that the device photocurrent signal measured under reverse bias and using appropriate steady state optical bias, allows the separate detection of the cyan and yellow fluorescence signals presented.
Resumo:
Glucose sensing is an issue with great interest in medical and biological applications. One possible approach to glucose detection takes advantage of measuring changes in fluorescence resonance energy transfer (FRET) between a fluorescent donor and an acceptor within a protein which undergoes glucose-induced changes in conformation. This demands the detection of fluorescent signals in the visible spectrum. In this paper we analyzed the emission spectrum obtained from fluorescent labels attached to a protein which changes its conformation in the presence of glucose using a commercial spectrofluorometer. Different glucose nanosensors were used to measure the output spectra with fluorescent signals located at the cyan and yellow bands of the spectrum. A new device is presented based on multilayered a-SiC:H heterostructures to detect identical transient visible signals. The transducer consists of a p-i'(a-SiC:H)-n/p-i(a-Si:H)-n heterostructure optimized for the detection of the fluorescence resonance energy transfer between fluorophores with excitation in the violet (400 nm) and emissions in the cyan (470 nm) and yellow (588 nm) range of the spectrum. Results show that the device photocurrent signal measured under reverse bias and using appropriate steady state optical bias, allows the separate detection of the cyan and yellow fluorescence signals. (C) 2013 Elsevier B.V. All rights reserved.
Resumo:
Water-based cellulose cholesteric liquid crystalline phases at rest can undergo structural changes induced by shear flow. This reflects on the deuterium spectra recorded when the system is investigated by rheo-nuclear magnetic resonance (rheo-NMR) techniques. In this work, the model system hydroxypropylcellulose (HPC)+water is revisited using rheo-NMR to clarify unsettled points regarding its behavior under shear and in relaxation. The NMR spectra allow the identification of five different stable ordering states, within shear and relaxation, which are well integrated in a mesoscopic picture of the system's structural evolution under shear and relaxation. This picture emerging from the large body of studies available for this system by other experimental techniques, accounts well for the NMR data and is in good agreement with the three distinct regions of steady shear flow recognized for some lyotropic LC polymers. Shear rates in between 0.1 and 1.0 s(-1) where investigated using a Taylor-Couette flow and deuterated water was used as solvent for the deuterium NMR (DNMR) analysis.
Resumo:
Mestrado em Engenharia Química
Resumo:
Two multinuclear complexes [Fe-6(mu(3)-O)(2)(mu(4)-O-2)L-10(OAc)(2)(H2O)(2)]center dot 2.625Et(2)O center dot 2.375H(2)O (1) and [(Fe11Cl)-Cl-III-(mu(4)-O)(3)(mu(3)-O)(5)L-16(dmf)(2.5)(H2O)(0.5)]center dot Et2O center dot 1.25dmf center dot 3.8H(2)O (2), where HL = 3,4,5-trimethoxybenzoic acid and dmf = dimethylformamide, have been prepared from trinuclear iron(III) carboxylates via their structural rearrangement in dimethylformamide or diethyl ether-dimethylformamide 9:1, respectively, and slow vapor diffusion of diethyl ether into the reaction mixture. Both compounds have been characterized by X-ray diffraction, optical, Mossbauer spectroscopy, and magnetic measurements. Complex 1 possesses a hexanuclear ferric peroxido-dioxido {Fe-6(O-2)(O)(2)}(12+) core unit, which adopts a recliner conformation, while complex 2 contains an unprecedented {Fe11O8Cl}(16+) core, in which 9 ferric ions are six-coordinate and the remaining two are five-coordinate. Another structural feature of note of the undecanuclear core is the presence of a deformed cubane entity {Fe-4(mu(3)-O)(mu(4)-O)(3)}(4+). Both complexes act as catalyst precursors for the oxidation of cyclohexane to cyclohexanol and cyclohexanone with aqueous H2O2, in the presence of pyrazinecarboxylic acid. Remarkable TONs and TOFs (the latter mainly for 1) with concomitant quite good yields have been achieved under mild conditions. Moreover, 1 exhibits remarkably high activity in an exceptionally short reaction time (45 min), being unprecedented for any metal catalyzed alkane oxidation by H2O2. The catalytic reactions proceed via Fenton type chemistry.
Resumo:
PURPOSE: Fatty liver disease (FLD) is an increasing prevalent disease that can be reversed if detected early. Ultrasound is the safest and ubiquitous method for identifying FLD. Since expert sonographers are required to accurately interpret the liver ultrasound images, lack of the same will result in interobserver variability. For more objective interpretation, high accuracy, and quick second opinions, computer aided diagnostic (CAD) techniques may be exploited. The purpose of this work is to develop one such CAD technique for accurate classification of normal livers and abnormal livers affected by FLD. METHODS: In this paper, the authors present a CAD technique (called Symtosis) that uses a novel combination of significant features based on the texture, wavelet transform, and higher order spectra of the liver ultrasound images in various supervised learning-based classifiers in order to determine parameters that classify normal and FLD-affected abnormal livers. RESULTS: On evaluating the proposed technique on a database of 58 abnormal and 42 normal liver ultrasound images, the authors were able to achieve a high classification accuracy of 93.3% using the decision tree classifier. CONCLUSIONS: This high accuracy added to the completely automated classification procedure makes the authors' proposed technique highly suitable for clinical deployment and usage.
Resumo:
Trabalho Final de Mestrado elaborado no Laboratório Nacional de Engenharia Civil (LNEC) para a obtenção do grau de Mestre em Engenharia Civil pelo Instituto Superior de Engenharia de Lisboa no âmbito do protocolo de cooperação entre o ISEL e o LNEC
Resumo:
Nas últimas décadas, devido ao desenvolvimento económico, e a uma necessidade constante de gerir os recursos energéticos, existe uma necessidade de procurar novas fontes de energia, em particular fontes de energia renováveis. O biodiesel surge assim como uma energia alternativa ao combustível fóssil. Este biocombustível tem ganho uma importância significativa na sociedade moderna. Quimicamente o biodiesel é constituído por ésteres metílicos de ácidos gordos de cadeia longa, derivados de óleos vegetais ou gorduras animais. O principal problema que este enfrenta é a sua susceptibilidade à oxidação, devido ao seu conteúdo de ácidos gordos insaturados, logo existe uma procura constante de soluções que possam solucionar este problema. É necessária a identificação de técnicas e métodos para retardar a seu envelhecimento ao longo do tempo. O objectivo deste trabalho consiste no estudo da estabilidade do biodiesel ao longo do tempo, quando armazenado a diferentes condições de temperatura, superiores às normalmente suportadas pelo biodiesel durante o armazenamento, de modo a acelerar o processo de degradação. As amostras de biodiesel foram sujeitas a duas temperaturas. Uma amostra de biodiesel não estabilizado foi colocada a uma temperatura entre 40 e 50ºC ao longo de 203 dias, e uma outra amostra foi colocada a uma temperatura entre 95º e 105ºC ao longo de 146 dias. Realizaram-se ensaios semanais de modo registar a evolução do envelhecimento do biodiesel. As análises foram efectuadas por espectrofotometria de ultravioleta e visível (UV-VIS) e por espectroscopia de absorção na região do infravermelho (FTIR). No UV-VIS foi possível observar que o aumento de temperatura foi responsável pela aceleração da oxidação do biodiesel que resulta num aumento generalizado da absorvância do biodiesel. Através das análises efectuadas no FTIR verificou-se a formação e aumento da banda dos hidroperóxidos (grupo ROOH) localizada entre 3000 e 3600 cm-1 nos espectros, e igualmente um alargamento na banda dos carbonilos (grupo C=O) entre 1500 e 1900 cm-1. Numa fase posterior testaram-se antioxidantes para retardar o envelhecimento do biodiesel. Os ensaios foram efectuados a uma temperatura entre 95º e 105ºC. Os antioxidantes utilizados foram o galhato de propilo (PG), o galhato de etilo (EG) e o ácido gálhico (AG). Recorreu-se a técnicas como o UV-VIS e o FTIR para o registo dos espectros do biodiesel ao longo do tempo. Através destas técnicas foi possível verificar a influência de antioxidantes na estabilidade oxidativa do biodiesel. O PG foi o antioxidante que melhor desempenho mostrou no retardamento da oxidação do biodiesel e a técnica que melhor permitiu analisar a acção dos antioxidantes foi o UVVIS. Os resultados obtidos por FTIR não se mostraram tão conclusivos. Para caracterizar o envelhecimento do biodiesel não estabilizado e estabilizado utilizou-se também a cromatografia gasosa (CG) para quantificar a percentagem de ésteres metílicos presentes nas diferentes amostras no inicio e no fim do processo de oxidação. O biodiesel envelheceu mais rapidamente para temperaturas mais elevadas e comprovou-se que o antioxidante que melhor estabiliza o biodiesel é o PG.
Resumo:
Independent component analysis (ICA) has recently been proposed as a tool to unmix hyperspectral data. ICA is founded on two assumptions: 1) the observed spectrum vector is a linear mixture of the constituent spectra (endmember spectra) weighted by the correspondent abundance fractions (sources); 2)sources are statistically independent. Independent factor analysis (IFA) extends ICA to linear mixtures of independent sources immersed in noise. Concerning hyperspectral data, the first assumption is valid whenever the multiple scattering among the distinct constituent substances (endmembers) is negligible, and the surface is partitioned according to the fractional abundances. The second assumption, however, is violated, since the sum of abundance fractions associated to each pixel is constant due to physical constraints in the data acquisition process. Thus, sources cannot be statistically independent, this compromising the performance of ICA/IFA algorithms in hyperspectral unmixing. This paper studies the impact of hyperspectral source statistical dependence on ICA and IFA performances. We conclude that the accuracy of these methods tends to improve with the increase of the signature variability, of the number of endmembers, and of the signal-to-noise ratio. In any case, there are always endmembers incorrectly unmixed. We arrive to this conclusion by minimizing the mutual information of simulated and real hyperspectral mixtures. The computation of mutual information is based on fitting mixtures of Gaussians to the observed data. A method to sort ICA and IFA estimates in terms of the likelihood of being correctly unmixed is proposed.
Resumo:
Linear unmixing decomposes a hyperspectral image into a collection of reflectance spectra of the materials present in the scene, called endmember signatures, and the corresponding abundance fractions at each pixel in a spatial area of interest. This paper introduces a new unmixing method, called Dependent Component Analysis (DECA), which overcomes the limitations of unmixing methods based on Independent Component Analysis (ICA) and on geometrical properties of hyperspectral data. DECA models the abundance fractions as mixtures of Dirichlet densities, thus enforcing the constraints on abundance fractions imposed by the acquisition process, namely non-negativity and constant sum. The mixing matrix is inferred by a generalized expectation-maximization (GEM) type algorithm. The performance of the method is illustrated using simulated and real data.
Resumo:
International Conference with Peer Review 2012 IEEE International Conference in Geoscience and Remote Sensing Symposium (IGARSS), 22-27 July 2012, Munich, Germany
Resumo:
Objetivos – Demonstrar o potencial da espetroscopia (1H) por ressonância magnética na doença degenerativa discal lombar e defender a integração desta técnica na rotina clínico‑imagiológica para a precisa classificação da involução vs degenerescência dos discos L4‑L5 e L5‑S1 em doentes com lombalgia não relacionável com causa mecânica. Material e métodos – O estudo incluiu 102 discos intervertebrais lombares de 123 doentes. Foram estudados 61 discos de L4‑L5, 41 discos de L5‑S1 e 34 discos de D12‑L1. Utilizou‑se um sistema de ressonância magnética de 1,5 T e técnica monovoxel. Obtiveram‑se os rácios [Lac/Nacetyl] e [Nacetyl/(Lac+Lípidos)] e aplicou‑se a ressonância de lípidos para avaliar a bioquímica do disco com o fim de conhecer o estado de involução vs degenerescência que o suscetibilizam para a instabilidade e sobrecarga. Avaliou‑se o comportamento dos rácios e do teor lipídico dos discos L4‑L5‑S1 e as diferenças apresentadas em relação a D12‑L1. Foi também realizada a comparação entre os discos L4‑L5, L5‑S1 e D12‑L1 na ponderação T2 (T2W), segundo a classificação ajustada (1‑4) de Pfirrmann. Resultados – Verificou‑se que os rácios e o valor dos lípidos dos discos L4‑L5‑S1 apresentaram diferenças estatisticamente significativas quando relacionados com os discos D12‑L1. O rácio [Lac/Nacetyl] em L4‑L5‑S1 mostrou‑se aumentado em relação a D12‑L1 (p=0,033 para os discos com grau de involução [1+2] e p=0,004 para os discos com grau [3+4]). Estes resultados sugerem que a involução vs degenerescência dos discos nos graus mais elevados condiciona um decréscimo do pico do Lactato. O rácio [Nacetyl/(Lac+Lip)] discrimina os graus de involução [1+2] do [3+4] no nível L4‑L5, apresentando os valores dos rácios (média 0,65 e 0,5 respetivamente com p=0,04). O rácio médio de [Nacetyl/(Lac+Lip)] dos discos L4‑L5 foi 1,8 vezes mais elevado do que em D12‑L1. O espetro lipídico em L4‑L5‑S1 nos graus mais elevados não mostrou ter uma prevalência constante quanto às frequências de ressonância. Conclusão – A espetroscopia (1H) dos discos intervertebrais poderá ter aplicação na discriminação dos graus de involução vs degenerescência e representar um contributo semiológico importante em suplemento à ponderação T2 convencional. As ressonâncias de lípidos dos discos L4‑L5 e L5‑S1, involuídos ou degenerados, devem ser avaliadas em relação a D12‑L1, utilizando este valor como referência, pois este último é o nível considerado estável e com baixa probabilidade de degenerescência.