1000 resultados para Métodos analíticos - Validação
Resumo:
FUNDAMENTO: A estandardização do padrão de imagens utilizada dentro da medicina foi realizada em 1993 por meio do padrão DICOM (Digital Imaging and Communications in Medicine). Diversos exames utilizam esse padrão e cada vez mais são necessários softwares capazes de manipular esse tipo de imagem, porém esses softwares geralmente não têm o formato livre e de código aberto, e isso dificulta o seu ajuste para os mais diferentes interesses. OBJETIVO: Desenvolver e validar um software livre e de código aberto capaz de manipular imagens DICOM de exames de angiotomografia de coronárias. MÉTODOS: Desenvolvemos e testamos o software intitulado ImageLab na avaliação de 100 exames selecionados de forma randômica por meio de um banco de dados. Foram realizadas 600 análises divididas por dois observadores utilizando o ImageLab e um outro software comercializado junto a aparelhos de tomografia computadorizada Philips Brilliance, na avaliação da presença de lesões e placas coronarianas nos territórios do Tronco da Coronária Esquerda (TCE) e na Artéria Descendente Anterior (ADA). Para avaliar as concordâncias intraobservador, interobservadores e intersoftware, utilizamos concordância simples e estatística Kappa. RESULTADOS: As concordâncias observadas entre os softwares foram em geral classificadas como substancial ou quase perfeitas na maioria das comparações. CONCLUSÃO: O software ImageLab concordou com o software Philips na avaliação de exames de angiotomografia de coronárias especialmente em pacientes sem lesões, com lesões inferiores a 50% no TCE e inferiores a 70% na ADA. A concordância para lesão >70% na ADA foi menor, porém isso também é observado quando se utiliza o padrão de referência anatômico.
Resumo:
FUNDAMENTO: A hipertensão autorreferida é um dado de interesse para saúde pública e acessível em estudos epidemiológicos, cuja validade deve ser verificada para o adequado emprego dessa informação. OBJETIVO: Verificar a validade da hipertensão autorreferida e os fatores associados em adultos e idosos na cidade de São Paulo, Brasil. MÉTODOS: Foram selecionados participantes do estudo transversal de base populacional Inquérito de Saúde no Município de São Paulo (ISA-Capital 2008) com 20 anos ou mais, de ambos os sexos, que tiveram sua pressão arterial aferida (n = 535). A hipertensão foi definida como Pressão arterial > 140/90 mmHg e/ou uso de medicamentos para hipertensão. Foram calculados sensibilidade, especificidade, valor preditivo positivo, valor preditivo negativo e coeficiente Kappa. A regressão de Poisson foi utilizada para identificar os fatores associados à sensibilidade da hipertensão autorreferida. RESULTADOS: A sensibilidade da hipertensão autorreferida foi 71,1% (IC95%: 64,8-76,9), especificidade 80,5% (IC95%: 75,6-84,8), valor preditivo positivo 73,7% (IC95%: 67,4-79,3), e valor preditivo negativo 78,5% (IC95%: 73,5-82,9). Houve concordância moderada entre hipertensão autorreferida e diagnóstico de hipertensão pela pressão arterial aferida (kappa = 0,52; IC95%: 0,45-0,59). Índice de massa corporal e escolaridade associaram-se independentemente à sensibilidade (índice de massa corporal > 25 kg/m²: RP = 1,42; IC95%: 1,15-1,76; escolaridade > 9 anos: RP=0,71; IC95%: 0,54-0,94). CONCLUSÃO: A hipertensão autorreferida mostrou-se válida em adultos e idosos no município de São Paulo, sendo um indicador apropriado para vigilância da prevalência da hipertensão, na ausência da pressão arterial medida. Sobrepeso associou-se positivamente à validade da hipertensão autorreferida. Outros estudos são necessários para elucidar a relação inversa entre a validade da hipertensão autorreferida e a escolaridade.
Resumo:
FUNDAMENTO: Escores de risco apresentam dificuldades para obter o mesmo desempenho em diferentes populações. OBJETIVO: Criar um modelo simples e acurado para avaliação do risco nos pacientes operados de doença coronariana e/ou valvar no Instituto do Coração da Universidade de São Paulo (InCor-HCFMUSP). MÉTODOS: Entre 2007 e 2009, 3.000 pacientes foram operados consecutivamente de doença coronariana e/ou valvar no InCor-HCFMUSP. Desse registro, dados de 2/3 dos pacientes foram utilizados para desenvolvimento do modelo (técnica de bootstrap) e de 1/3 para validação interna do modelo. O desempenho do modelo (InsCor) foi comparado aos complexos 2000 Bernstein-Parsonnet (2000BP) e EuroSCORE (ES). RESULTADOS: Apenas 10 variáveis foram selecionadas: Idade > 70 anos; sexo feminino; cirurgia de revascularização coronariana + valva; infarto de miocárdio < 90 dias; reoperação; tratamento cirúrgico da valva aórtica; tratamento cirúrgico da valva tricúspide; creatinina < 2mg/dL; fração de ejeção < 30%; e eventos. O teste de Hosmer Lemeshow para o InsCor foi de 0,184, indicando uma excelente calibração. A área abaixo da curva ROC foi de 0,79 para o InsCor, 0,81 para o ES e 0,82 para o 2000BP, confirmando que os modelos são bons e similares na discriminação. CONCLUSÕES: O InsCor e o ES tiveram melhor desempenho que o 2000BP em todas as fases da validação; pórem o novo modelo, além de se identificar com os fatores de risco locais, é mais simples e objetivo para a predição de mortalidade nos pacientes operados de doença coronariana e/ou valvar no InCor-HCFMUSP.
Resumo:
FUNDAMENTO: Diversos registros locais buscam de forma isolada retratar características clínicas de pacientes internados com Insuficiência Cardíaca (IC) em hospitais e comunidades brasileiras. De forma geral, a análise desses dados sugere que existam diferenças importantes na etiologia, nos fatores de descompensação, no tratamento e no prognóstico de pacientes com IC nas diferentes regiões brasileiras. OBJETIVOS: Avaliar as características demográficas, clínicas, prognósticas de 1.200 pacientes admitidos com diagnóstico clínico de insuficiência cardíaca descompensada em um grupo de 60 hospitais representativos das diferentes regiões brasileiras. MÉTODOS: Estudo observacional transversal (registro) com seguimento longitudinal de doze meses (visitas de admissão, alta hospitalar, três meses, seis meses e doze meses após inclusão), em que pacientes admitidos em hospitais da rede pública e privada com quadro clínico primariamente de IC definida serão estudados. RESULTADOS: Os resultados serão apresentados logo após o término da coleta, avaliação da qualidade e análise estatística dos dados. CONCLUSÕES: A análise dos resultados deste registro multicêntrico permitirá um planejamento mais adequado do aporte de recursos financeiros, pessoais e tecnológicos para a área da saúde, bem como o planejamento de medidas preventivas mais eficazes na IC descompensada.
Resumo:
FUNDAMENTO: Estados congestivos podem ser identificados e manejados através de algoritmos como o Diuretic Treatment Algorithm (DTA) para ajuste de diurético por telefone, com enfoque na avaliação clínica. Porém, o DTA está disponível somente em língua inglesa. OBJETIVO: Adaptar o DTA e testar sua aplicabilidade para uso no Brasil em pacientes ambulatoriais com IC. MÉTODOS: Seguiram-se as etapas de tradução, síntese, retrotradução, avaliação por comitê de especialistas e pré-teste (aplicabilidade clínica por meio de ensaio clínico randomizado). O DTA foi denominado, na versão para o Brasil, algoritmo de ajuste de diurético (AAD). Os pacientes foram randomizados para grupo intervenção (GI) - ajuste de diurético conforme o AAD - ou grupo controle (GC) - ajuste convencional. Foi avaliado o escore clínico de congestão (ECC) e o peso para ambos os grupos. RESULTADOS: Foram realizadas 12 modificações no DTA. Incluíram-se 34 pacientes. Para aqueles congestos, o aumento de diurético guiado pelo AAD resultou em maior resolução da congestão, com redução de dois pontos no ECC para 50% da amostra -2 (-3,5; -1,0), enquanto a mediana para o GC foi 0 (-1,25; -1,0), (p < 0,001). A mediana de variação de peso foi maior no GI -1,4 (-1,7; -0,5) quando comparado ao GC 0,1 (1,2; -0,6), p = 0,001. CONCLUSÕES: O ADD mostrou-se aplicável na prática clínica após adaptação e parece resultar em melhor controle da congestão em pacientes com IC. A efetividade clínica da ferramenta merece ser testada em amostra maior de pacientes visando sua validação para uso no Brasil (Universal Trial Number: U1111-1130-5749) (Arq Bras Cardiol. 2013; [online]. ahead print, PP.0-0).
Resumo:
Fundamento: A ausência de instrumentos capazes de mensurar o nível de conhecimento de pacientes com insuficiência cardíaca sobre sua própria síndrome, participantes de programas de reabilitação, demonstra a carência de recomendações específicas a respeito da quantidade ou do conteúdo de informações necessárias. Objetivo: Construir e validar um questionário para avaliar o conhecimento sobre sua condição de pacientes portadores de insuficiência cardíaca participantes de programas de reabilitação cardíaca. Métodos: O instrumento foi construído com base no questionário de conhecimento para doença coronariana e aplicado em 96 pacientes com insuficiência cardíaca, com média de idade de 60,22 ± 11,6 anos, 64% homens. A reprodutibilidade foi obtida por meio do coeficiente de correlação intraclasse, utilizando-se as situações do método de teste-reteste. A consistência interna foi obtida pelo alfa de Cronbach e a validade do construto, pela análise fatorial exploratória. Resultados: A versão final do instrumento apresentou 19 questões dispostas em dez áreas de importância para a educação do paciente. O instrumento proposto apresentou um índice de clareza de 8,94 ± 0,83. O valor do coeficiente de correlação intraclasse foi de 0,856 e do alfa de Cronbach, 0,749. A análise fatorial revelou cinco fatores associados às áreas de conhecimento. Quando os escores finais foram comparados com as características da população, verificou-se que baixa escolaridade e baixa renda estão significativamente associadas a baixos escores de conhecimento. Conclusão: O instrumento possui índice de clareza satisfatório e de validade adequado, podendo ser utilizado para avaliar o conhecimento de pacientes com insuficiência cardíaca participantes de programas de reabilitação cardíaca.
Resumo:
This paper deals with the estimation of milk production by means of weekly, biweekly, bimonthly observations and also by method known as 6-5-8, where one observation is taken at the 6th week of lactation, another at 5th month and a third one at the 8th month. The data studied were obtained from 72 lactations of the Holstein Friesian breed of the "Escola Superior de Agricultura "Luiz de Queiroz" (Piracicaba), S. Paulo, Brazil), being 6 calvings on each month of year and also 12 first calvings, 12 second calvings, and so on, up to the sixth. The authors criticize the use of "maximum error" to be found in papers dealing with this subject, and also the use of mean deviation. The former is completely supersed and unadvisable and latter, although equivalent, to a certain extent, to the usual standard deviation, has only 87,6% of its efficiency, according to KENDALL (9, pp. 130-131, 10, pp. 6-7). The data obtained were compared with the actual production, obtained by daily control and the deviations observed were studied. Their means and standard deviations are given on the table IV. Inspite of BOX's recent results (11) showing that with equal numbers in all classes a certain inequality of varinces is not important, the autors separated the methods, before carrying out the analysis of variance, thus avoiding to put together methods with too different standard deviations. We compared the three first methods, to begin with (Table VI). Then we carried out the analysis with the four first methods. (Table VII). Finally we compared the two last methods. (Table VIII). These analysis of variance compare the arithmetic means of the deviations by the methods studied, and this is equivalent to compare their biases. So we conclude tht season of calving and order of calving do not effect the biases, and the methods themselves do not differ from this view point, with the exception of method 6-5-8. Another method of attack, maybe preferrable, would be to compare the estimates of the biases with their expected mean under the null hypothesis (zero) by the t-test. We have: 1) Weekley control: t = x - 0/c(x) = 8,59 - 0/ = 1,56 2) Biweekly control: t = 11,20 - 0/6,21= 1,80 3) Monthly control: t = 7,17 - 0/9,48 = 0,76 4) Bimonthly control: t = - 4,66 - 0/17,56 = -0,26 5) Method 6-5-8 t = 144,89 - 0/22,41 = 6,46*** We denote above by three asterisks, significance the 0,1% level of probability. In this way we should conclude that the weekly, biweekly, monthly and bimonthly methods of control may be assumed to be unbiased. The 6-5-8 method is proved to be positively biased, and here the bias equals 5,9% of the mean milk production. The precision of the methods studied may be judged by their standard deviations, or by intervals covering, with a certain probability (95% for example), the deviation x corresponding to an estimate obtained by cne of the methods studied. Since the difference x - x, where x is the mean of the 72 deviations obtained for each method, has a t distribution with mean zero and estimate of standard deviation. s(x - x) = √1+ 1/72 . s = 1.007. s , and the limit of t for the 5% probability, level with 71 degrees of freedom is 1.99, then the interval to be considered is given by x ± 1.99 x 1.007 s = x ± 2.00. s The intervals thus calculated are given on the table IX.
Resumo:
O presente trabalho relata a determinação do P2O5 em fertilizantes simples e em misturas, pelos métodos, espectrofotométrico (espectrofotômetro Beckman, modelo B) diferencial do ácido fosfovánadomólíbdico e pelo método volumétrico alcalimétrico (fosfomolibdato de amônio). Relata também a determinação do P2O5 solúvel em solução de ácido cítrico a 2% nos mesmos materiais, pelos métodos espectrofotométrico e colorimétrico (Klett-Summerson) dif erenciais e volumétrico. Os dados obtidos permitem afirmar que os métodos espectrofotométrico e colorimétrico diferenciais são precisos e muito mais simples e rápidos que o método volumétrico. Considerando-se que os métodos espectrofotométrico e colorimétrico são mais simples, e rápidos que o método volumétrico e que êste está mais sujeito à erros devido às operações de precipitação, filtração, lavagem do precipitado, etc, pode-se adotar os dois primeiros em substituição ao método volumétrico de determinação do P2O5 total e solúvel em solução de ácido cítrico a 2%, em fertilizantes fosfatados, simples e em misturas.
Resumo:
Neste trabalho é apresentada uma marcha analítica simples, rápida e acessível à maioria dos nossos laboratórios, visando a determinação de constituintes inorgânicos do caldo de cana de açúcar, vinhaça e melaço. Foram estudadas duas técnicas para a digestão do material (via seca e via úmida) e a seguir, nos extratos obtidos determinados cálcio, magnésio, potássio, enxofre e fósforo. Os dados obtidos mostraram que para a análise dos citados constituintes, nos mencionados materiais, pode ser empregado, indiferentemente, o ataque por via seca ou úmida, excetuando-se a determinação de enxofre em melaço que deve ser efetuada por via úmida. As técnicas de análise preconizadas apresentaram uma adequada precisão, conforme demonstram os resultados obtidos neste trabalho.
Resumo:
Foi estudada a influência de tres tratamentos com. a finalidade de evitar o escurecimento enzimático (branqueamento, SO2 e ácido ascórbico) e de tres métodos de processamento (appertização, congelação e liofilização) nas propriedades organoléticas da maçã em pedaços da variedade Bruckner do Brasil. Imediatamente após seu recebimento, uma terça parte das frutas foi processada. Outra terça parte foi colocada em câmara fria a 1°C por três semanas e a restante deixada sob as mesmas condições por seis semanas, sendo estas duas últimas processadas imediatamente após os respectivos tempos de armazenamento prévio. Os resultados mostraram que o melhor tratamento foi a combinação branqueamento-appertização para todos os atributos de qualidade, exceto para cor, em que as combinações SO2-congelação e ácido ascórbico-congelação foram superiores. A appertização foi o método de processamento mais adequado para a variedade em estudo. O armazenamento prévio não melhorou as propriedades organoléticas da maçã em pedaços, chegando a ser até prejudicial para a maioria dos tratamentos utilizados.
Resumo:
Foi estudada a influência de tres tratamentos com a finalidade de evitar o escurecimento enzimático (branqueamento, SO2 e ácido ascórbico) e de tres métodos de processamento (appertização, congelação e liofilização) nas propriedades organoléticas da maçã em pedaços, da variedade Ohio Beauty. Imediatamente após seu recebimento, uma terça parte das frutas foi processada. Outra terça parte foi colocada em câmara fria a 1°C por três semanas e a restante deixada sob as mesmas condições por seis semanas, sendo estas duas últimas processadas imediatamente após os respectivos tempos de armazenamento prévio. Os resultados mostraram que o melhor tratamento foi a combinação branqueamento-congelação para todos os atributos de qualidade, exceto para cor, em que a combinação ácido ascórbico-congelação foi superior. a congelação foi o método de processamento mais adequado para a variedade em estudo. O armazenamento prévio teve alguma influência nas propriedades organoléticas da maçã em pedaços, de modo que, as amostras correspondentes à parte não armazenada foram julgadas inferiores para quase todos os atributos de qualidade.
Resumo:
Foi estudada a influência de tres métodos de controle de escurecimento enzimático (branqueamento, ácido ascórbico e SO2) nas propriedades organoléticas da maçã em pedaços da variedade Ohio Beauty, conservada por congelação e liofilização. Imediatamente após seu recebimento, uma terça parte das frutas foi processada. Outra terça parte foi colocada em câmara fria a 1°C por tres semanas e a restante deixada sob as mesmas condições por seis semanas, sendo estas duas últimas processadas imediatamente após os respectivos tempos de armazenamento prévio. Os resultados mostraram que, para a congelação, o branqueamento foi o melhor tratamento para todos os atributos de qualidade, exceto para cor, em que o ácido ascórbico foi mais eficiente. Este último foi ligeiramente superior ao SO2 quanto à qualidade geral do produto. Para a liofilização, o tratamento com SO2 foi superior ao branqueamento quanto ao sabor e qualidade geral do produto, porém, foi inferior quanto à cor. Nenhum dos tratamentos, entretanto, controlou de maneira eficiente o escurecimento no produto liofilizado.
Resumo:
Três métodos de determinação do ácido clorogênico em café verde foram comparados. Foram utilizadas seis amostras de café, sendo que três de qualidade de bebida Mole e três Rio. Os resultados obtidos com os três métodos para os cafés Rio não diferiram estatísticamente entre si, embora os métodos de MOORES et al. e WEISS (oficial da AOAC) deram valores menores para os cafés Mole em relação ao método cromatográfico de GNAGY modificado. É discutido uma provável interferência da alta atividade da polifenol oxidase geralmente encontrada nos cafés Mole que oxidaria o ácido clorogênico durante a extração pelos dois primeiros métodos.
Resumo:
O método micro Bailey-Andrew, oficial da A. O. A, C. (1970) e o proposto por NAVELLIER et al. (1969) para determinação de cafeína em café, foram comparados. Para extração e purificação seguiu-se os dois métodos citados e para a determinação propriamente dita utilizou-se o peso, nitrogênio total, espectrofotometria com correção da linha de base e o pico à 273 nm. As seguintes conclusões foram tiradas: a) A determinação por pesagem não deve ser utilizada para nenhum dos dois métodos de extração e purificação, pois além dos valores encontrados serem bem acima dos reais, os coeficientes de variação também foram altos. b) O método de extração e purificação de NAVELLIER et al. (1969) não consegue remover interferentes nitrogenados, mas talvez possa ser utilizado quando a cafeína é determinada por espectrofotometria com correção da linha de base. c) Não houve diferença significativa entre a determinação da cafeína pelo nitrogênio e espectrofotometria com correlação da linha de base quando se seguiu a extração e purificação da A, O. A. C. (1970).