994 resultados para Linear Viscoelastic Materials


Relevância:

20.00% 20.00%

Publicador:

Resumo:

El present treball es proposa l'estudi fonnal de I'habitat construtt amb materials duradors a Catalunya durant el Bronze Final i la Primera Edat del Ferro, i se centra en l'aninisi dels materials i tecniques de construcció emprats, així com en l' estructura de la casa (planta, dimensions, superfície). Els elements definidors d'aquests habitacles en els períodes estudiats consisteixen en l'ús sistematic de la pedra i la terra com a materials de construcció i la disposició d'habitacions de planta rectangular compartint parets mitgeres, amb poca compartimentació interna i pocs agenc¡:aments al seu interior (llar, forn, banquetes). Les dimensions maximes d'aquestes habitacions no superen, per nonna general, els 20 metres quadrats. La unifonnitat d'aquestes construccions, unida a la poca compartimentació de l'espai, suggereix que ens trobem davant una arquitectura poc especialitzada, que podria correspondre a una societat amb una organització socio-política poc complexa.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El jaciment del Castellot de la Roca Roja (Benifallet, Baix Ebre) es localitza a la riba esquerra del riu Ebre, sobre una formac ió rocallosa de relleus molt abruptes, només accessible per I' extrem septentrional, on es va construir un fossat i una muralla de doble parament que s'adossa a una torre quadranguiar. Sens dubte, la se va posició és immillorable per tal d'exercir el control del pas pel riu.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El present treball ofereix una revisió de les pintures murals de la basílica de «Es Cap des Port» (Fornells, Menorca), així com un estudi de caracterització arqueometrica deIs materials i tecniques per microscopia optica, tant amb lupa binocular com amb micro scopi petrografic mitjanliant ¡¡lmina prima, difracció de raigs X i microscopia electronica de rastreig. Els resultats han permes identificar els pigments emprats, així com la seva tecnica d'aplicació. Igua!ment, han permes caracteritzar els morters i han desvelat l' existencia de dos tipus diferents de suporto Malgrat aquestes diferencies en els morters, els pigments són sempre els mateixos per a tots els conjunts pictorics caracteritzats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We showed earlier how to predict the writhe of any rational knot or link in its ideal geometric configuration, or equivalently the average of the 3D writhe over statistical ensembles of random configurations of a given knot or link (Cerf and Stasiak 2000 Proc. Natl Acad. Sci. USA 97 3795). There is no general relation between the minimal crossing number of a knot and the writhe of its ideal geometric configuration. However, within individual families of knots linear relations between minimal crossing number and writhe were observed (Katritch et al 1996 Nature 384 142). Here we present a method that allows us to express the writhe as a linear function of the minimal crossing number within Conway families of knots and links in their ideal configuration. The slope of the lines and the shift between any two lines with the same

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: Pohjois-Euroopan silikaattisten kalkitusaineiden reaktiivisuus astiakoemenetelmällä ja kahdella pH-staattisella menetelmällä arvioituna

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: The objective of this study was to evaluate associations between aortic pulse wave velocity (PWV) and aortic and carotid vessel wall thickness (VWT) using cardiovascular magnetic resonance imaging (MRI) in patients with hypertension as compared with healthy adult volunteers. MATERIALS AND METHODS: Local medical ethics approval was obtained and the participants gave informed consent. Fifteen patients with hypertension (5 men and 10 women; mean [SD] age, 49 [14] years) and 15 age- and sex-matched healthy volunteers were prospectively included and compared. All participants underwent MRI examination for measuring aortic and carotid VWT and aortic PWV with well-validated MRI techniques at 1.5- and 3-T MRI systems: PWV was assessed from velocity-encoded MRI and VWT was assessed by using dual-inversion black-blood gradient-echo imaging techniques. Paired t tests were used for testing differences between the volunteers and the patients and Pearson correlation (r) and univariable and multivariable stepwise linear regression analyses were used to test associations between aortic and carotid arterial wall thickness and stiffness. RESULTS: Mean values for aortic PWV and aortic and carotid VWT (indexed for body surface area [BSA]) were all significantly higher in patients with hypertension as compared with the healthy volunteers (ie, aortic PWV, 7.0 ± 1.4 m/s vs 5.7 ± 1.3 m/s; aortic VWT/BSA, 0.12 ± 0.03 mL/m vs 0.10 ± 0.03 mL/m; carotid VWT/BSA, 0.04 ± 0.01 mL/m vs 0.03 ± 0.01 mL/m; all P < 0.01). Aortic PWV was highly correlated with aortic VWT/BSA (r = 0.76 and P = 0.002 in the patients vs r = 0.63 and P = 0.02 in the volunteers), and in the patients, aortic PWV was moderately correlated with carotid VWT/BSA (r = 0.50; P = 0.04). In the volunteers, correlation between aortic PWV and carotid VWT/BSA was not significant (r = 0.40; P = 0.13). In addition, aortic VWT/BSA was significantly correlated with carotid VWT/BSA, in both the patients (r = 0.60; P = 0.005) and volunteers (r = 0.57; P = 0.007). CONCLUSIONS: In the patients with hypertension and the healthy volunteers, the aortic PWV is associated more strongly with aortic wall thickness than with carotid wall thickness, reflecting site-specific coupling between vascular wall thickness and function.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present here a nonbiased probabilistic method that allows us to consistently analyze knottedness of linear random walks with up to several hundred noncorrelated steps. The method consists of analyzing the spectrum of knots formed by multiple closures of the same open walk through random points on a sphere enclosing the walk. Knottedness of individual "frozen" configurations of linear chains is therefore defined by a characteristic spectrum of realizable knots. We show that in the great majority of cases this method clearly defines the dominant knot type of a walk, i.e., the strongest component of the spectrum. In such cases, direct end-to-end closure creates a knot that usually coincides with the knot type that dominates the random closure spectrum. Interestingly, in a very small proportion of linear random walks, the knot type is not clearly defined. Such walks can be considered as residing in a border zone of the configuration space of two or more knot types. We also characterize the scaling behavior of linear random knots.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of this research was to evaluate the materials Iowa uses as a granular subbase and to determine if it provides adequate drainage. Numerous laboratory and in-situ tests were conducted on the materials currently being used in Iowa. The follow conclusions can be made based on the test results: 1. The crushed concrete that is used as a subbase material has a relatively low permeability compared to many other materials used by other states. 2. Further research and tests are needed to find the necessary parameters for crushed concrete to make sure it is providing its optimum drainage and preventing premature damage of the pavement. 3. We have definitely made improvements in drainage in the past few months, but there are many areas that we can improve on that will increase the permeability of this material and insure that the pavement system is safe from premature damage due to water. The current gradation specification for granular subbase material at the start of this study was: Sieve # % Passing 1” 100 #8 10-35 #50 0-15 #200 0-6

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Content and Language Integrated Learning (CLIL)Materials in Chemistry and English following the principles of CLIL / Content-based Instruction and Task-based Learning

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Asphalt binder is typically modified with poly type (styrene-butadiene-styrene or SBS) polymers to improve its rheological properties and performance grade. The elastic and principal component of SBS polymers is butadiene. For the last decade, butadiene prices have fluctuated and significantly increased, leading state highway agencies to search for economically viable alternatives to butadiene based materials. This project reports the recent advances in polymerization techniques that have enabled the synthesis of elastomeric, thermoplastic, block-copolymers (BCPs) comprised of styrene and soybean oil, where the “B” block in SBS polymers is replaced with polymerized triglycerides derived from soybean oil. These new breeds of biopolymers have elastomeric properties comparable to well-established butadiene-based styrenic BCPs. In this report, two types of biopolymer formulations are evaluated for their ability to modify asphalt binder. Laboratory blends of asphalt modified with the biopolymers are tested for their rheological properties and performance grade. Blends of asphalt modified with the biopolymers are compared to blends of asphalt modified with two commonly used commercial polymers. The viscoelastic properties of the blends show that biopolymers improve the performance grade of the asphalt to a similar and even greater extent as the commercial SBS polymers. Results shown in this report indicate there is an excellent potential for the future of these biopolymers as economically and environmentally favorable alternatives to their petrochemically-derived analogs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In addition to the importance of sample preparation and extract separation, MS detection is a key factor in the sensitive quantification of large undigested peptides. In this article, a linear ion trap MS (LIT-MS) and a triple quadrupole MS (TQ-MS) have been compared in the detection of large peptides at subnanomolar concentrations. Natural brain natriuretic peptide, C-peptide, substance P and D-Junk-inhibitor peptide, a full D-amino acid therapeutic peptide, were chosen. They were detected by ESI and simultaneous MS(1) and MS(2) acquisitions. With direct peptide infusion, MS(2) spectra revealed that fragmentation was peptide dependent, milder on the LIT-MS and required high collision energies on the TQ-MS to obtain high-intensity product ions. Peptide adsorption on surfaces was overcome and peptide dilutions ranging from 0.1 to 25 nM were injected onto an ultra high-pressure LC system with a 1 mm id analytical column and coupled with the MS instruments. No difference was observed between the two instruments when recording in LC-MS(1) acquisitions. However, in LC-MS(2) acquisitions, a better sensitivity in the detection of large peptides was observed with the LIT-MS. Indeed, with the three longer peptides, the typical fragmentation in the TQ-MS resulted in a dramatic loss of sensitivity (> or = 10x).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To determine if the results of resin-dentin microtensile bond strength (µTBS) is correlated with the outcome parameters of clinical studies on non-retentive Class V restorations. METHODS: Resin-dentin µTBS data were obtained from one test center; the in vitro tests were all performed by the same operator. The µTBS testing was performed 8h after bonding and after 6 months of storing the specimens in water. Pre-test failures (PTFs) of specimens were included in the analysis, attributing them a value of 1MPa. Prospective clinical studies on cervical restorations (Class V) with an observation period of at least 18 months were searched in the literature. The clinical outcome variables were retention loss, marginal discoloration and marginal integrity. Furthermore, an index was formulated to be better able to compare the laboratory and clinical results. Estimates of adhesive effects in a linear mixed model were used to summarize the clinical performance of each adhesive between 12 and 36 months. Spearman correlations between these clinical performances and the µTBS values were calculated subsequently. RESULTS: Thirty-six clinical studies with 15 adhesive/restorative systems for which µTBS data were also available were included in the statistical analysis. In general 3-step and 2-step etch-and-rinse systems showed higher bond strength values than the 2-step/3-step self-etching systems, which, however, produced higher values than the 1-step self-etching and the resin modified glass ionomer systems. Prolonged water storage of specimens resulted in a significant decrease of the mean bond strength values in 5 adhesive systems (Wilcoxon, p<0.05). There was a significant correlation between µTBS values both after 8h and 6 months of storage and marginal discoloration (r=0.54 and r=0.67, respectively). However, the same correlation was not found between µTBS values and the retention rate, clinical index or marginal integrity. SIGNIFICANCE: As µTBS data of adhesive systems, especially after water storage for 6 months, showed a good correlation with marginal discoloration in short-term clinical Class V restorations, longitudinal clinical trials should explore whether early marginal staining is predictive for future retention loss in non-carious cervical restorations.