995 resultados para Intra-familial transmission
Resumo:
Alveolar capillary dysplasia with misalignment of pulmonary veins (ACD/MPV) is a rare and lethal developmental disorder of the lung defined by a constellation of characteristic histopathological features. Nonpulmonary anomalies involving organs of gastrointestinal, cardiovascular, and genitourinary systems have been identified in approximately 80% of patients with ACD/MPV. We have collected DNA and pathological samples from more than 90 infants with ACD/MPV and their family members. Since the publication of our initial report of four point mutations and 10 deletions, we have identified an additional 38 novel nonsynonymous mutations of FOXF1 (nine nonsense, seven frameshift, one inframe deletion, 20 missense, and one no stop). This report represents an up to date list of all known FOXF1 mutations to the best of our knowledge. Majority of the cases are sporadic. We report four familial cases of which three show maternal inheritance, consistent with paternal imprinting of the gene. Twenty five mutations (60%) are located within the putative DNA-binding domain, indicating its plausible role in FOXF1 function. Five mutations map to the second exon. We identified two additional genic and eight genomic deletions upstream to FOXF1. These results corroborate and extend our previous observations and further establish involvement of FOXF1 in ACD/MPV and lung organogenesis.
Resumo:
Promazine hydrochloride was injected accidentally in the antecubital artery of a 42-year-old woman, resulting in severe ischemia of the second and third fingers of her right hand which lasted for four days before she was hospitalized. Vasodilation by combining axillary plexus block and intravenous sodium nitroprusside did not improve ischemia and local thrombolysis was performed using recombinant tissue-type plasminogen activator (50 mg over 8 hours), resulting in normalization of digital pressure in one of the two affected fingers. The outcome was favourable and amputation could be avoided.
Resumo:
The regulation of electricity transmission and distribution business is an essential issue for any electricity market; it is widely introduced in developed electricity markets of Great Britain, Scandinavian countries and United States of America and other. Those markets which were liberalized recently also need well planned regulation model to be chosen and implemented. In open electricity markets the sectors of electricity distribution and transmission remain monopolies, so called "natural monopolies", as introducing the competition into these sectors in most cases appears to be inefficient. Thatis why regulation becomes very important as its main tasks are: to set reasonable tariffs for customers, to ensure non-discriminating process of electricity transmission and distribution, at the same time to provide distribution companies with incentives to operate efficiently and the owners of the companies with reasonable profits as well; the problem of power quality should be solved at the same time. It should be mentioned also, that there is no incentive scheme which will be suitable for any conditions, that is why it is essential to study differentregulation models in order to form the best one for concrete situation. The aim of this Master's Thesis is to give an overview over theregulation of electricity transmission and distribution in Russia. First, the general information about theory of regulation of natural monopolies will be described; the situation in Russian network business and the importance of regulation process for it will be discussed next. Then there is a detailed description ofexisting regulatory system and the process of tariff calculation with an example. And finally, in the work there is a brief analysis of problems of present scheme of regulation, an attempt to predict the following development of regulationin Russia and the perspectives and risks connected to regulation which could face the companies that try to enter Russian electricity market (such as FORTUM OY).
Resumo:
Background: It is debated whether chronic hypertension increases the risk of cardiovascular incidents during anaesthesia. Methods: We studied all elective surgical operations performed in adults under general or regional anaesthesia between 2000 and 2004, in 24 hospitals collecting computerised clinical data on all anaesthetia since 1996. The focus was on cardiovascular incidents, though other anaesthesia-related incidents were also evaluated. Results: Among 124 939 interventions, 27 881 (22%) were performed in hypertensive patients. At least one cardiovascular incident occurred in 7549 interventions (6% [95% CI 5.9-6.2%]). The average adjusted odds ratio of cardiovascular risk in patients with chronic hypertension was 1.38 (95% CI 1.27-1.49). However, across hospitals, adjusted odd ratios varied from 0.41 up to 2.25. Hypertension did not increase the risk of other incidents. Conclusions: Hypertensive patients are still at risk of intra-operative cardiovascular incidents. The heterogeneity of the risk to develop cardiovascular incidents varied across hospitals, despite taking into account casemix and hospital characteristics. These variations suggest that anaesthetic practices differ across anesthesia services
Resumo:
In the electrical industry the 50 Hz electric and magnetic fields are often higher than in the average working environment. The electric and magnetic fields can be studied by measuring or by calculatingthe fields in the environment. For example, the electric field under a 400 kV power line is 1 to 10 kV/m, and the magnetic flux density is 1 to 15 µT. Electricand magnetic fields of a power line induce a weak electric field and electric currents in the exposed body. The average current density in a human being standing under a 400 kV line is 1 to 2 mA/m2. The aim of this study is to find out thepossible effects of short term exposure to electric and magnetic fields of electricity power transmission on workers' health, in particular the cardiovascular effects. The study consists of two parts; Experiment I: influence on extrasystoles, and Experiment II: influence on heart rate. In Experiment I two groups, 26 voluntary men (Group 1) and 27 transmission-line workers (Group 2), were measured. Their electrocardiogram (ECG) was recorded with an ambulatory recorder both in and outside the field. In Group 1 the fields were 1.7 to 4.9 kV/m and 1.1 to 7.1 pT; in Group 2 they were 0.1 to 10.2 kV/m and 1.0 to 15.4 pT. In the ECG analysis the only significant observation was a decrease in the heart rate after field exposure (Group 1). The drop cannot be explained with the first measuring method. Therefore Experiment II was carried out. In Experiment II two groups were used; Group 1 (26 male volunteers) were measured in real field exposure, Group 2 (15 male volunteers) in "sham" fields. The subjects of Group 1 spent 1 h outside the field, then 1 h in the field under a 400 kV transmission line, and then again 1 h outside the field. Under the 400 kV linethe field strength varied from 3.5 to 4.3 kV/m, and from 1.4 to 6.6 pT. Group 2spent the entire test period (3 h) in a 33 kV outdoor testing station in a "sham" field. ECG, blood pressure, and electroencephalogram (EEG) were measured by ambulatory methods. Before and after the field exposure, the subjects performed some cardiovascular autonomic function tests. The analysis of the results (Experiments I and II) showed that extrasystoles or arrythmias were as frequent in the field (below 4 kV/m and 4 pT) as outside it. In Experiment II there was no decrease detected in the heart rate, and the systolic and diastolic blood pressure stayed nearly the same. No health effects were found in this study.