980 resultados para Immunoassay, Assay validation, Accuracy, recision, Hyperinsulinemia


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Most patients with acute suppurative meningitis are otherwise healthy individuals with regard to immune mechanisms against invasive bacterial disease. This medical emergency is among the most dramatic and potentially ravaging diseases that affect humans, particularly young children. The illness often strikes suddenly, and can either result in death or leave the survivors with significant neurological dysfunctions. The demonstration of a bacterial aetiology is necessary for decisions regarding treatment and prophylaxis. Conventional bacteriological methods frequently fail to identify an agent, as a result of administration of antibiotics or delayed lumbar punctures. We investigated the major aetiologic sources of unspecified bacterial meningitis cases (G00.9, ISCD-10) by polymerase chain reaction (PCR)-based identification of Neisseria meningitidis (crgA), Streptococcus pneumoniae (ply) and Haemophilus influenzae (bexA) in cerebrospinal fluid samples. The multiplex PCR detected N. meningitidis in 92%, S. pneumoniae in 4% and H. influenzae in 1% of the 192 clinical samples assayed; 3% were negative for all three DNA targets. Bacterial DNA detection was found to be a valuable adjunct to enhance bacterial meningitis surveillance when the yield of specimens by culture is reduced. The implementation of PCR assays as a diagnostic procedure in Public Health Laboratories is perceived to be a significant advance in the investigation of bacterial meningitis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Total ankle replacement remains a less satisfactory solution compared to other joint replacements. The goal of this study was to develop and validate a finite element model of total ankle replacement, for future testing of hypotheses related to clinical issues. To validate the finite element model, an experimental setup was specifically developed and applied on 8 cadaveric tibias. A non-cemented press fit tibial component of a mobile bearing prosthesis was inserted into the tibias. Two extreme anterior and posterior positions of the mobile bearing insert were considered, as well as a centered one. An axial force of 2kN was applied for each insert position. Strains were measured on the bone surface using digital image correlation. Tibias were CT scanned before implantation, after implantation, and after mechanical tests and removal of the prosthesis. The finite element model replicated the experimental setup. The first CT was used to build the geometry and evaluate the mechanical properties of the tibias. The second CT was used to set the implant position. The third CT was used to assess the bone-implant interface conditions. The coefficient of determination (R-squared) between the measured and predicted strains was 0.91. Predicted bone strains were maximal around the implant keel, especially at the anterior and posterior ends. The finite element model presented here is validated for future tests using more physiological loading conditions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Elevation of the biliary CEA level in patients with liver metastases from colorectal carcinoma has been reported. The aim of this study is to determine the potential value of biliary CEA assay in the early detection of liver metastases. Biliary and serum CEA levels were determined in patients operated on for a colorectal cancer and in control groups. Among 13 patients with liver metastases from colorectal carcinomas, biliary CEA levels were markedly elevated (> 40 ng/ml) in nine, moderately elevated (5-40 ng/ml) in two and normal (arbitrarily defined as < 5 ng/ml) in two. Of 28 patients with primary colorectal carcinoma without detectable hepatic secondaries, three had marked CEA elevation in the bile, 10 had moderate CEA elevation and 15 had normal levels. Among nine patients with non-malignant hepatobiliary pathology, there was one marked biliary CEA elevation, one moderate elevation and seven normal levels. None of the 13 individuals with no identified hepatobiliary pathology had elevated biliary CEA levels. The follow-up of patients with a primary colorectal tumour, no evidence of hepatic secondaries and a biliary CEA elevation is of particular interest. If subsequent appearance of liver metastases is found in such cases, intra-operative biliary CEA assay could be considered a valuable diagnostic test. Further studies will then have to prove the possible benefit of a specific treatment for this group of patients.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Comparison of the use of indirect immunofluorescence assay (IFA), immunochromatography assay (ICA-BD) and reverse transcription-polymerase chain reaction (RT-PCR) for detecting human respiratory syncytial virus (HRSV) in 306 nasopharyngeal aspirates samples (NPA) was performed in order to assess their analytical performance. By comparing the results obtained using ICA-BD with those using IFA, we found relative indices of 85.0% for sensitivity and 91.2% for specificity, and the positive (PPV) and negative (NPV) predictive values were 85.0% and 91.2%, respectively. The relative indices for sensitivity and specificity as well as the PPV and NPV for RT-PCR were 98.0%, 89.0%, 84.0% and 99.0%, respectively, when compared to the results of IFA. In addition, comparison of the results of ICA-BD and those of RT-PCR yielded relative indices of 79.5% for sensitivity and 95.4% for specificity, as well as PPV and NPV of 92.9% and 86.0%, respectively. Although RT-PCR has shown the best performance, the substantial agreement between the ICA-BD and IFA results suggests that ICA-BD, also in addition to being a rapid and facile assay, could be suitable as an alternative diagnostic screening for HRSV infection in children.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Human adenovirus (HAdV) and human respiratory syncytial virus (HRSV) are important etiologic agents of acute respiratory infections. In this study, a duplex polymerase chain reaction (PCR) assay was developed for the simultaneous detection of HAdV and HRSV in clinical samples. Sixty previously screened nasopharyngeal aspirates were used: 20 HAdV-positive, 20 HRSV-positive and 20 double-negative controls. Eight samples were positive for both viruses. The duplex PCR assay proved to be as sensitive and specific as single-target assays and also detected the mixed infections with certainty. The identification of both viruses in a single reaction offers a reduction in both cost and laboratory diagnostic time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Anterior shoulder stabilization surgery with the arthroscopic Bankart procedure can have a high recurrence rate in certain patients. Identifying these patients to modify outcomes has become a focal point of research. PURPOSE: The Instability Shoulder Index Score (ISIS) was developed to predict the success of arthroscopic Bankart repair. Scores range from 0 to 10, with higher scores predicting a higher risk of recurrence after stabilization. The interobserver reliability of the score is not known. STUDY DESIGN: Cohort study (diagnosis); Level of evidence, 2. METHODS: This is a prospective multicenter (North America and Europe) study of patients suffering from shoulder instability and waiting for stabilization surgery. Five pairs of independent evaluators were asked to score patient instability severity with the ISIS. Patients also completed functional scores (Western Ontario Shoulder Instability Index [WOSI], Disabilities of the Arm, Shoulder and Hand-short version [QuickDASH], and Walch-Duplay test). Data on age, sex, number of dislocations, and type of surgery were collected. The test-retest method and intraclass correlation coefficient (ICC: >0.75 = good, >0.85 = very good, and >0.9 = excellent) were used for analysis. RESULTS: A total of 114 patients with anterior shoulder instability were included, of whom 89 (78%) were men. The mean age was 28 years. The ISIS was very reliable, with an ICC of 0.933. The mean number of dislocations per patient was higher in patients who had an ISIS of ≥6 (25 vs 14; P = .05). Patients who underwent more complex arthroscopic procedures such as Hill-Sachs remplissage or open Latarjet had higher preoperative ISIS outcomes, with a mean score of 4.8 versus 3.4, respectively (P = .002). There was no correlation between the ISIS and the quality-of-life questionnaires, with Pearson correlations all >0.05 (WOSI = 0.39; QuickDASH = 0.97; Walch-Duplay = 0.08). CONCLUSION: Our results show that the ISIS is reliable when used in a multicenter study with anterior traumatic instability populations. There was no correlation between the ISIS and the quality-of-life questionnaires, but surgical decisions reflected its increased use.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A study was carried out to evaluate the presence of serological markers for the immunodiagnosis of the vertical transmission of toxoplasmosis. We tested the sensitivity, specificity and predictive values (positive and negative) of different serological methods for the early diagnosis of congenital toxoplasmosis. In a prospective longitudinal study, 50 infants with suspected congenital toxoplasmosis were followed up in the ambulatory care centre of Congenital Infections at University Hospital in Goiânia, Goiás, Brazil, from 1 January 2004-30 September 2005. Microparticle Enzyme Immunoassay (MEIA), Enzyme-Linked Fluorescent Assay (ELFA) and Immune-Fluorescent Antibody Technique (IFAT) were used to detect specific IgM anti-Toxoplasma gondii antibodies and a capture ELISA was used to detect specific IgA antibodies. The results showed that 28/50 infants were infected. During the neonatal period, IgM was detected in 39.3% (11/28) of those infected infants and IgA was detected in 21.4% (6/28). The sensitivity, specificity and predictive values (positive and negative) of each assay were, respectively: MEIA and ELFA: 60.9%, 100%, 100%, 55.0%; IFAT: 59.6%, 91.7%, 93.3%, 53.7%; IgA capture ELISA: 57.1%, 100%, 100%, 51.2%. The presence of specific IgM and IgA antibodies during the neonatal period was not frequent, although it was correlated with the most severe cases of congenital transmission. The results indicate that the absence of congenital disease markers (IgM and IgA) in newborns, even after confirming the absence with several techniques, does not constitute an exclusion criterion for toxoplasmosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Partner violence against women is a major public health problem. Although there are currently a number of validated screening and diagnostic tools that can be used to evaluate this type of violence, such tools are not available in Spain. The aim of this study is to analyze the validity and reliability of the Spanish version of the Index of Spouse Abuse (ISA). Methods: A cross-sectional study was carried out in 2005 in two health centers in Granada, Spain, in 390 women between 18 and 70 years old. Analyses of the factorial structure, internal consistency, test-retest reliability, and construct validity were conducted. Cutoff points for each subscale were also defined. For the construct validity analysis, the SF-36 perceived general health dimension, the Rosenberg Self-Esteem Scale and the Goldberg 12-item General Health Questionnaire were included. Results: The psychometric analysis shows that the instrument has good internal consistency, reproducibility, and construct validity. Conclusions: The scale is useful for the analysis of partner violence against women in both a research setting and a healthcare setting