963 resultados para ION-BEAM


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Congenital long QT syndrome (LQTS) with an estimated prevalence of 1:2000-1:10 000 manifests with prolonged QT interval on electrocardiogram and risk for ventricular arrhythmias and sudden death. Several ion channel genes and hundreds of mutations in these genes have been identified to underlie the disorder. In Finland, four LQTS founder mutations of potassium channel genes account for up to 40-70% of genetic spectrum of LQTS. Acquired LQTS has similar clinical manifestations, but often arises from usage of QT-prolonging medication or electrolyte disturbances. A prolonged QT interval is associated with increased morbidity and mortality not only in clinical LQTS but also in patients with ischemic heart disease and in the general population. The principal aim of this study was to estimate the actual prevalence of LQTS founder mutations in Finland and to calculate their effect on QT interval in the Finnish background population. Using a large population-based sample of over 6000 Finnish individuals from the Health 2000 Survey, we identified LQTS founder mutations KCNQ1 G589D (n=8), KCNQ1 IVS7-2A>G (n=1), KCNH2 L552S (n=2), and KCNH2 R176W (n=16) in 27 study participants. This resulted in a weighted prevalence estimate of 0.4% for LQTS in Finland. Using a linear regression model, the founder mutations resulted in a 22- to 50-ms prolongation of the age-, sex-, and heart rate-adjusted QT interval. Collectively, these data suggest that one of 250 individuals in Finland may be genetically predisposed to ventricular arrhythmias arising from the four LQTS founder mutations. A KCNE1 D85N minor allele with a frequency of 1.4% was associated with a 10-ms prolongation in adjusted QT interval and could thus identify individuals at increased risk of ventricular arrhythmias at the population level. In addition, the previously reported associations of KCNH2 K897T, KCNH2 rs3807375, and NOS1AP rs2880058 with QT interval duration were confirmed in the present study. In a separate study, LQTS founder mutations were identified in a subgroup of acquired LQTS, providing further evidence that congenital LQTS gene mutations may underlie acquired LQTS. Catecholaminergic polymorphic ventricular tachycardia (CPVT) is characterized by exercise-induced ventricular arrhythmias in a structurally normal heart and results from defects in the cardiac Ca2+ signaling proteins, mainly ryanodine receptor type 2 (RyR2). In a patient population of typical CPVT, RyR2 mutations were identifiable in 25% (4/16) of patients, implying that noncoding variants or other genes are involved in CPVT pathogenesis. A 1.1 kb RyR2 exon 3 deletion was identified in two patients independently, suggesting that this region may provide a new target for RyR2-related molecular genetic studies. Two novel RyR2 mutations showing a gain-of-function defect in vitro were identified in three victims of sudden cardiac death. Extended pedigree analyses revealed some surviving mutation carriers with mild structural abnormalities of the heart and resting ventricular arrhythmias suggesting that not all RyR2 mutations lead to a typical CPVT phenotype, underscoring the relevance of tailored risk stratification of a RyR2 mutation carrier.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Reactive Pulsed Laser Deposition is a single step process wherein the ablated elemental metal reacts with a low pressure ambient gas to form a compound. We report here a Secondary Ion Mass Spectrometry based analytical methodology to conduct minimum number of experiments to arrive at optimal process parameters to obtain high quality TiN thin film. Quality of these films was confirmed by electron microscopic analysis. This methodology can be extended for optimization of other process parameters and materials. (C) 2009 Elsevier B.V. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Boron neutron capture therapy (BNCT) is a form of chemically targeted radiotherapy that utilises the high neutron capture cross-section of boron-10 isotope to achieve a preferential dose increase in the tumour. The BNCT dosimetry poses a special challenge as the radiation dose absorbed by the irradiated tissues consists of several dose different components. Dosimetry is important as the effect of the radiation on the tissue is correlated with the radiation dose. Consistent and reliable radiation dose delivery and dosimetry are thus basic requirements for radiotherapy. The international recommendations for are not directly applicable to BNCT dosimetry. The existing dosimetry guidance for BNCT provides recommendations but also calls for investigating for complementary methods for comparison and improved accuracy. In this thesis the quality assurance and stability measurements of the neutron beam monitors used in dose delivery are presented. The beam monitors were found not to be affected by the presence of a phantom in the beam and that the effect of the reactor core power distribution was less than 1%. The weekly stability test with activation detectors has been generally reproducible within the recommended tolerance value of 2%. An established toolkit for epithermal neutron beams for determination of the dose components is presented and applied in an international dosimetric intercomparison. The measured quantities (neutron flux, fast neutron and photon dose) by the groups in the intercomparison were generally in agreement within the stated uncertainties. However, the uncertainties were large, ranging from 3-30% (1 standard deviation), emphasising the importance of dosimetric intercomparisons if clinical data is to be compared between different centers. Measurements with the Exradin type 2M ionisation chamber have been repeated in the epithermal neutron beam in the same measurement configuration over the course of 10 years. The presented results exclude severe sensitivity changes to thermal neutrons that have been reported for this type of chamber. Microdosimetry and polymer gel dosimetry as complementary methods for epithermal neutron beam dosimetry are studied. For microdosimetry the comparison of results with ionisation chambers and computer simulation showed that the photon dose measured with microdosimetry was lower than with the two other methods. The disagreement was within the uncertainties. For neutron dose the simulation and microdosimetry results agreed within 10% while the ionisation chamber technique gave 10-30% lower neutron dose rates than the two other methods. The response of the BANG-3 gel was found to be linear for both photon and epithermal neutron beam irradiation. The dose distribution normalised to dose maximum measured by MAGIC polymer gel was found to agree well with the simulated result near the dose maximum while the spatial difference between measured and simulated 30% isodose line was more than 1 cm. In both the BANG-3 and MAGIC gel studies, the interpretation of the results was complicated by the presence of high-LET radiation.