991 resultados para INTRA-ABDOMINAL HYPERTENSION
Resumo:
Vitamin D deficiency , defined by a 25-OH vitamin D3 plasma level < 30 ng/ml, is highly prevalent in the population. Several observational studies have suggested that such a deficiency increases the risk of hypertension development. Vitamin D seems to have an inhibitory effect on renin secretion and might by this mechanism exert an antihypertensive effect. Recent randomized trials have failed however to demonstrate a blood pressure lowering effect of vitamin D supplementation.
Resumo:
Abstract Hypertension resistant to lifestyle interventions and antihypertensive medications is a common problem encountered by physicians in everyday practice. It is most often defined as a blood pressure remaining ≥ 140/90 mmHg despite the regular intake of at least three drugs lowering blood pressure by different mechanisms, one of them being a diuretic. It now appears justified to include, unless contraindicated or not tolerated, a blocker of the renin-angiotensin system and a calcium channel blocker in this drug regimen, not only to gain antihypertensive efficacy, but also to prevent or regress target organ damage and delay the development of cardiorenal complications. A non-negligible fraction of treatment-resistant hypertension have normal "out of office" blood pressures. Ambulatory blood pressure monitoring and/or home blood pressure recording should therefore be routinely performed to identify patients with true resistant hypertension, i.e. patients who are more likely to benefit from treatment intensification.
Resumo:
Aim: Gas6 is known to be elevated in sepsis, correlating with the severity of infection and¦organ failure. We aimed to investigate the performance of Gas6 plasma levels at¦admission to predict the risk of mortality in a cohort of septic patients.¦Methods: We used prospectively collected data and plasma samples from the "Sepsis¦Cohorte Romande". Gas6 level was measured by ELISA at admission and expressed in¦percentage relative to its level in a pool of normal plasma.¦Results: Non-survivors (n=21) presented higher Gas6 levels than survivors (n=73) (median¦258% vs 164%, IQR 194 and 117 respectively) (p=0.0027). Gas6 correlated positively with¦different cytokines and was the best mortality predictor, as shown by the ROC curves area.¦In patients with septic shock (n=66), using 249% as a cut-off value, Gas6 measurement¦had a specificity of 67% and a sensitivity of 81% for predicting mortality. ROC curve area¦was 0.75. Positive and negative predictive values were 57% and 87%, respectively.¦Conclusion: Thus, Gas6 plasma level at admission might be a useful tool to predict¦mortality in patients with septic shock. Although Gas6 hold promise as an early sepsis¦marker, its precise implication in sepsis remains to be elucidated. Our observation should¦be further investigated in larger prospective clinical trials.
Resumo:
OBJECTIVE:: Report of a 16q24.1 deletion in a premature newborn, demonstrating the usefulness of array-based comparative genomic hybridization in persistent pulmonary hypertension of the newborn and multiple congenital malformations. DESIGN:: Descriptive case report. SETTING:: Genetic department and neonatal intensive care unit of a tertiary care children's hospital. INTERVENTIONS:: None. PATIENT:: We report the case of a preterm male infant, born at 26 wks of gestation. A cardiac malformation and bilateral hydronephrosis were diagnosed at 19 wks of gestation. Karyotype analysis was normal, and a 22q11.2 microdeletion was excluded by fluorescence in situ hybridization analysis. A cesarean section was performed due to fetal distress. The patient developed persistent pulmonary hypertension unresponsive to mechanical ventilation and nitric oxide treatment and expired at 16 hrs of life. MEASUREMENTS AND MAIN RESULTS:: An autopsy revealed partial atrioventricular canal malformation and showed bilateral dilation of the renal pelvocaliceal system with bilateral ureteral stenosis and annular pancreas. Array-based comparative genomic hybridization analysis (Agilent oligoNT 44K, Agilent Technologies, Santa Clara, CA) showed an interstitial microdeletion encompassing the forkhead box gene cluster in 16q24.1. Review of the pulmonary microscopic examination showed the characteristic features of alveolar capillary dysplasia with misalignment of pulmonary veins. Some features were less prominent due to the gestational age. CONCLUSIONS:: Our review of the literature shows that alveolar capillary dysplasia with misalignment of pulmonary veins is rare but probably underreported. Prematurity is not a usual presentation, and histologic features are difficult to interpret. In our case, array-based comparative genomic hybridization revealed a 16q24.1 deletion, leading to the final diagnosis of alveolar capillary dysplasia with misalignment of pulmonary veins. It emphasizes the usefulness of array-based comparative genomic hybridization analysis as a diagnostic tool with implications for both prognosis and management decisions in newborns with refractory persistent pulmonary hypertension and multiple congenital malformations.
Resumo:
BACKGROUND: Hypertension, hypercholesterolemia, obesity and smoking are highly prevalent among patients with familial premature coronary artery disease (FP-CAD). Whether these risk factors equally affect other family members remains unknown. METHODS: We examined 222 FP-CAD patients, 158 unaffected sibs, 197 offspring and 94 spouses in 108 FP-CAD families (> or = 2 sibs having survived CAD diagnosed before age 51 (M)/56 (F)), and compared them to population controls. RESULTS: Unaffected sibs had a higher prevalence of hypertension (49% versus 24%, p<0.001), hypercholesterolemia (47% versus 34%, p=0.002), abdominal obesity (35% versus 24%, p=0.006) and smoking (39% versus 24%, p=0.001) than population controls. Offspring had a higher prevalence of hypertension (females), hypercholesterolemia and abdominal obesity than population controls. No difference was observed between spouses and controls. Compared to unaffected sibs, FP-CAD affected sibs had a similar risk factor profile, except for smoking, which was more prevalent (76% versus 39%, p=0.008). CONCLUSIONS: Hypertension, obesity and hypercholesterolemia are highly prevalent among first-degree relatives, but not spouses, of patients with FP-CAD. These persons deserve special medical attention due to their familial/genetic susceptibility to atherogenic metabolic abnormalities. In these families, smoking may be the trigger for FP-CAD.
Resumo:
The aim was to propose a strategy for finding reasonable compromises between image noise and dose as a function of patient weight. Weighted CT dose index (CTDI(w)) was measured on a multidetector-row CT unit using CTDI test objects of 16, 24 and 32 cm in diameter at 80, 100, 120 and 140 kV. These test objects were then scanned in helical mode using a wide range of tube currents and voltages with a reconstructed slice thickness of 5 mm. For each set of acquisition parameter image noise was measured and the Rose model observer was used to test two strategies for proposing a reasonable compromise between dose and low-contrast detection performance: (1) the use of a unique noise level for all test object diameters, and (2) the use of a unique dose efficacy level defined as the noise reduction per unit dose. Published data were used to define four weight classes and an acquisition protocol was proposed for each class. The protocols have been applied in clinical routine for more than one year. CTDI(vol) values of 6.7, 9.4, 15.9 and 24.5 mGy were proposed for the following weight classes: 2.5-5, 5-15, 15-30 and 30-50 kg with image noise levels in the range of 10-15 HU. The proposed method allows patient dose and image noise to be controlled in such a way that dose reduction does not impair the detection of low-contrast lesions. The proposed values correspond to high- quality images and can be reduced if only high-contrast organs are assessed.
Resumo:
A presente investigação tem como objectivo analisar a evolução do comércio intra-sectorial nas relações bilaterais entre Portugal e os países da União Europeia durante o período de 1995-2008 para os sectores: 31 e 34 e o impacto sobre das principais variáveis explicativas: diferença do rendimento per capita, diferença das dotações relativas, valor mínimo do rendimento per capita, valor máximo do rendimento per capita, BORDER (adjacência/fronteira), distância geográfica e dimensão do mercado (das economias) sobre o comércio intra-sectorial. A intensidade e a contribuição do comércio intra-sectorial é medida em termos absolutos e relativos através do índice proposto por Grubel e Lloyd (1975); a desagregação do comércio intra-sectorial horizontal e vertical é efectuada utilizando o critério de Abd-EL-Rahman (1991) e Grenaway et al. (1994) aplicado ao índice de Grubel e Lloyd. Os resultados obtidos mostraram que o comércio intra-sectorial vertical representa maior peso no total do comércio intra-sectorial nas relações bilaterais entre Portugal e a União Europeia, para ambos os sectores tanto em termos absolutos como em termos relativos. Em termos dos resultados econométricos verificou-se que a variável, proxy diferença do consumo eléctrico per capita utilizada para medir as dotações relativas possui um efeito negativo sobre o comércio intra-sectorial. As variáveis dimensão do mercado e valor mínimo do rendimento per capita apresentam um impacto positivo sobre o comércio intra-sectorial.
Resumo:
Background: Few data exist on secular trends of high blood pressure (HBP) detection and control in low and middle income countries, particularly in the African region. This study examines trends of HBP over 25 years based on 4 independent population surveys. In the Seychelles, heath care is free to all inhabitants within a national health system, inclusive all HBP medications. Previous studies have shown a transition from traditional to cardiometabolic cardiovascular risk factors in Seychelles. Age adjusted cardiovascular disease mortality rates is high but decreasing over the last two decades.
Resumo:
Purpose: To determine whether the need for retreatment after an initial phase of 3 monthly intravitreal injections of ranibizumab shows an intra-individual regular rhythm and to what degree it varies between different patients. Methods: Prospective study with 42 patients with exudative AMD, treatment naïve. Loading dose of 3 monthly doses of ranibizumab (0,5 mg), followed by a 12 months pro re nata (PRN) regimen according to early exudative signs on HD-OCT Cirrus, Zeiss. The follow-up visits were intensified (week 4, 5, 6, 7, 8, 10, 12, 14, 16, 20, etc after each injection) in order to detect recurrences early, and injection followed within 3 days in cases of subretinal fluid, cysts, or central thickness increase of>50microns. Intervals were calculated between injections for the 12 month follow-up with PRN treatment. Variability was expressed as standard deviation (SD). Results: Visual acuity (VA) improved from a mean ETDRS score of 61.6 (SD 10.8) at baseline to 68.0 (SD 10.2) at month 3 and to 74.7(SD 9.0) at month 12. The 15 patients who have already completed the study showed maintenance of the VA improvement. Central foveal thickness improved from a mean value of 366 microns (baseline) to 253 microns (month 3), well maintained thereafter. Mean number of injections was 8.8 (SD 3.5,range 0-12) per 12 months of follow-up (after 3 doses), with mean individual treatment-recurrence (TR) intervals ranging from 28->365 days (mean 58). Intraindividual variability of TR intervals (SD) was 7.1 days as a mean value (range 1.7¡V22.6). It ranged within 20% of the mean intra-individual interval for 30 (91%) and within 15% for 21 patients (64%). The first interval was within 1 week of the mean intra-individual interval in 64% and within 2 weeks in 89% of patients. Conclusions: The majority of AMD patients showed a relatively stable rhythm for PRN injections of ranibizumab after initial loading phase, associated with excellent functional/anatomical results. The initial interval last loading dose-first recurrence may have a predictive value for further need of treatment, potentially facilitating follow-up and patient care.
Resumo:
Pulmonary hypertension (PH) is a complex disease leading, in its advance form, to a decreased quality of life and early mortality. In the early stage, non specific signs and symptoms are the rule. The diagnosis is often missed, leaving the patient alone to face the disease and its repercussion on his daily life. This article reviews the main PH causes and predisposing conditions. Signs and symptoms suggesting the diagnosis are reviewed as well as conditions recognised at high risk for the disease. The key role of echocardiography in establishing the diagnosis, assessing PH severity, cardiac repercussions and/or potential aetiologies, is addressed. Finally the importance of a multidisciplinary approach is recommended.