1000 resultados para Hngry measurement


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Hybrid opto-digital joint transform correlator (HODJTC) is effective for image motion measurement, but it is different from the traditional joint transform correlator because it only has one optical transform and the joint power spectrum is directly input into a digital processing unit to compute the image shift. The local cross-correlation image can be directly obtained by adopting a local Fourier transform operator. After the pixel-level location of cross-correlation peak is initially obtained, the up-sampling technique is introduced to relocate the peak in even higher accuracy. With signal-to-noise ratio >= 20 dB, up-sampling factor k >= 10 and the maximum image shift <= 60 pixels, the root-mean-square error of motion measurement accuracy can be controlled below 0.05 pixels.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel method based on wavelength-multiplexed line-of-sight absorption and profile fitting for non-uniform flow field measurement is reported. A wavelength scanning combing laser temperature and current modulation WMS scheme is used to implement the wavelength-multiplexed-profile fitting method. Second harmonic (2f) signal of eight H2O transitions features near 7,170 cm(-1) are measured in one period using a single tunable diode laser. Spatial resolved temperature distribution upon a CH4/air premixed flat flame burner is obtained. The result validates the feasibility of strategy for non-uniform flow field diagnostics by means of WMS-2f TDLAS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The forward scattering light (FSL) received by the detector can cause uncertainties in turbidity measurement of the coagulation rate of colloidal dispersion, and this effect becomes more significant for large particles. In this study, the effect of FSL is investigated on the basis of calculations using the T-matrix method, an exact technique for the computation of nonspherical scattering. The theoretical formulation and relevant numerical implementation for predicting the contribution of FSL in the turbidity measurement is presented. To quantitatively estimate the degree of the influence of FSL, an influence ratio comparing the contribution of FSL to the pure transmitted light in the turbidity measurement is introduced. The influence ratios evaluated under various parametric conditions and the relevant analyses provide a guideline for properly choosing particle size, measuring wavelength to minimize the effect of FSL in turbidity measurement of coagulation rate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The total cross-section for the dd → 4HeK+K− reaction has been measured at a beam momentum of 3.7GeV/c, corresponding to an excess energy of 39MeV, which is the maximum possible atthe Cooler Synchrotron COSY-Jülich. A deuterium cluster-jet target and the ANKE forward magnetic spectrometer, placed inside the storage ring, have been employed in this investigation. We find a total cross-section of σtot < 14 pb, which brings into question the viability of investigating the dd → 4He a0(980)reaction as a means of studying isospin violation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An RF system for the CSRe (cooling storage experimental ring) is designed and manufactured domestically. The present paper mainly describes the RF system design in five main sections: ferrite ring, RF cavity, RF generator, low level system and cavity cooling. The cavity is based on a type of coaxial resonator which is shorted at the end with one gap and loaded with domestic ferrite rings. The RF generator is designed in the push-pull mode and the low level control system is based on a DSP+FGPA+DDS+USB inter...

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The characteristic Ll, Lα, Lβ and Lγx-rays of Au and energy shifts produced by 20–50MeV 16O5+ beams on a thick Au ilm are measured with a Si (Li) detector. Cross-section ratios of σ(Ll)/σ(Lα), σ(Lβ)/σ(Lα) andσ(Lγ)/σ(Lα) versus O5+ energy show that consistent calculations yield considerably better agreements. Energy shifts Ll, Lα, Lβ and Lγ x-rays of Au target increase with more incidence energy. The main application for these measurements is multi-element trace analysis through particle induced x-ray emission.