974 resultados para High Magnetic Field


Relevância:

80.00% 80.00%

Publicador:

Resumo:

There is described data processing at the flaw detector with combined multisectional eddy-current transducer and heterofrequency magnetic field. The application of this method for detecting flaws in rods and pipes under the conditions of significant transverse displacements is described.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Recent advances in signal analysis have engendered EEG with the status of a true brain mapping and brain imaging method capable of providing spatio-temporal information regarding brain (dys)function. Because of the increasing interest in the temporal dynamics of brain networks, and because of the straightforward compatibility of the EEG with other brain imaging techniques, EEG is increasingly used in the neuroimaging community. However, the full capability of EEG is highly underestimated. Many combined EEG-fMRI studies use the EEG only as a spike-counter or an oscilloscope. Many cognitive and clinical EEG studies use the EEG still in its traditional way and analyze grapho-elements at certain electrodes and latencies. We here show that this way of using the EEG is not only dangerous because it leads to misinterpretations, but it is also largely ignoring the spatial aspects of the signals. In fact, EEG primarily measures the electric potential field at the scalp surface in the same way as MEG measures the magnetic field. By properly sampling and correctly analyzing this electric field, EEG can provide reliable information about the neuronal activity in the brain and the temporal dynamics of this activity in the millisecond range. This review explains some of these analysis methods and illustrates their potential in clinical and experimental applications.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this paper, a phenomenologically motivated magneto-mechanically coupled finite strain elastic framework for simulating the curing process of polymers in the presence of a magnetic load is proposed. This approach is in line with previous works by Hossain and co-workers on finite strain curing modelling framework for the purely mechanical polymer curing (Hossain et al., 2009b). The proposed thermodynamically consistent approach is independent of any particular free energy function that may be used for the fully-cured magneto-sensitive polymer modelling, i.e. any phenomenological or micromechanical-inspired free energy can be inserted into the main modelling framework. For the fabrication of magneto-sensitive polymers, micron-size ferromagnetic particles are mixed with the liquid matrix material in the uncured stage. The particles align in a preferred direction with the application of a magnetic field during the curing process. The polymer curing process is a complex (visco) elastic process that transforms a fluid to a solid with time. Such transformation process is modelled by an appropriate constitutive relation which takes into account the temporal evolution of the material parameters appearing in a particular energy function. For demonstration in this work, a frequently used energy function is chosen, i.e. the classical Mooney-Rivlin free energy enhanced by coupling terms. Several representative numerical examples are demonstrated that prove the capability of our approach to correctly capture common features in polymers undergoing curing processes in the presence of a magneto-mechanical coupled load.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Background: Eosinophilic esophagitis (EoE) has emerged as a leading cause of dysphagia in adults. Characteristic esophageal features on endoscopy include structural/fibrostenotic (rings, narrow caliber, strictures) and inflammatory manifestations (longitudinal furrows, exudates, edema). Aim: The purpose of this study was to correlate the clinical, endoscopic and histopathologic features in adult EoE patients. Methods: A total of 106 encounters of 81 patients with EoE were analyzed. Data included an EoE-directed symptom-severity patient questionnaire evaluating symptoms of dysphagia (frequency, intensity, duration), meal duration, chest pain, and overall symptom severity. Video recordings of endoscopies were reviewed in a blinded manner using a classification and grading scheme for the esophageal features of EoE. Histopathology was reviewed for peak eosinophil count/high power field by pathologists blinded to the patients' clinical status. Associations between endoscopic features, histology and symptoms were evaluated using the Spearman rank correlation analysis. Results: The endoscopic severity of both structural and inflammatory esophageal features of EoE, including rings, exudates, longitudinal furrows, and edema, correlated significantly with peak eosinophil counts (see Table 1). Presence of "crepe paper mucosa" did not demonstrate significant association with peak eosinophil counts. Both structural (rings, narrow-caliber esophagus and strictures) and inflammatory (furrows, exudates and edema) composite endoscopic scores demonstrated a strong correlation with peak eosinophil counts. The strongest association with the degree of esophageal eosinophilia was found with a combination of both structural and inflammatory findings (p < 0.0001). The esophageal diameter (in mm) was negatively correlated with overall symptom severity (Spearman's rho = -0.4883, P = 0.0339). None of the individual or combined patient reported symptoms correlated significantly with either endoscopic or histopathologic findings. Conclusion: The severity of both structural and inflammatory endoscopic features associated with EoE is significantly associated with the degree of esophageal eosinophilia. Patient reported symptom severity was not associated with the degree of esophageal eosinophilia. Esophageal stricture diameter was inversely correlated with EoE symptom severity. The prognostic and therapeutic implications of these observations need to be determined.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

An alternative approach to the fundamental general physics concepts has been proposed. We demonstrate that the electrostatic potential energy of a discrete or a continuous system of charges should be stored by the charges and not the field. It is found that there is a possibility that any electric field has no energy density, as well as magnetic field. It is found that there is no direct relation between the electric or magnetic energy and photons. An alternative derivation of the blackbody radiation formula is proposed. It is also found that the zero-point of energy of electromagnetic radiation may not exist.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

INTRODUCTION: Eddy currents induced by switching of magnetic field gradients can lead to distortions in short echo-time spectroscopy or diffusion weighted imaging. In small bore magnets, such as human head-only systems, minimization of eddy current effects is more demanding because of the proximity of the gradient coil to conducting structures. METHODS: In the present study, the eddy current behavior achievable on a recently installed 7 tesla-68 cm bore head-only magnet was characterized. RESULTS: Residual effects after compensation were shown to be on the same order of magnitude as those measured on two whole body systems (3 and 4.7 T), while using two to three fold increased gradient slewrates.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The activity of eosinophilic esophagitis (EoE) can be assessed with patient-reported outcomes and biologic measures. Patient-reported outcomes include symptoms and quality of life, whereas biologic measures refer to endoscopic, histologic, and biochemical activity (e.g. blood biomarkers). So far, a validated tool to assess EoE activity in the above-mentioned dimensions is lacking. Given the lack of a standardized way to assess EoE activity in the various dimensions, the results of different clinical trials may be difficult to compare. For symptom assessment in adult patients, the symptom 'dysphagia' should be evaluated according to different standardized food consistencies. Furthermore, symptom assessment should take into account the following items: avoidance of specific food categories, food modification, and time to eat a regular meal. A distinct symptom recall period (e.g. 2 weeks) has to be defined for symptom assessment. Performing an 'esophageal stress test' with ingestion of a standardized meal to measure symptom severity bears the potential risk of acute food bolus impaction and should therefore be avoided. The description of endoscopic findings in EoE has meanwhile been standardized. Histologic evaluation of EoE activity should report either the size of the high-power field used or count the eosinophils per mm(2). There is a current lack of blood biomarkers demonstrating a good correlation with histologic activity in esophageal biopsies. The development and validation of an adult and pediatric EoE activity index is urgently needed not only for clinical trials and observational studies, but also for daily practice.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Els monopols es defineixen, teòricament, com càrregues que generen camps amb divergència diferent de cero. Malgrat això, les entitats amb comportament mimètic al dels monopols magnètics, segueix sent compatible amb ∇·B=0, han estat detectades experimentalment en gels d’espín (‘spin-ices’). Aquesta aparent contradicció pot generar confusió i, per tant, requereix explicació. D’altra banda, s’estudien propietats duals del materials amb càrregues magnètiques efectives tals com la ‘magnetricity’ en els ‘spinices’ (conductivitat de les càrregues magnètiques davant un camp magnètic extern). Com una conseqüència de la magnetricitat, l’apantallament del camp magnètic en materials amb càrregues magnètiques és analitzat. Estudio la propagació d’ones electromagnètiques transversals en medis materials infinits i en plasmes magnètics diluïts davant la presència de camps elèctrics externs constants. Aquesta propagació és dual a la propagació d’ones en plasmes de càrregues elèctriques davant la presència de camps magnètics externs, constants. Finalment, estudio el frenat elèctric d’un conductor de càrregues magnètiques amb un efecte dual al frenat magnètic en conductors elèctrics.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The paleomagnetic investigations carried out in the 70's on Oligo-Miocene volcanics of Sardinia have demonstrated that the island was turned by 35-30 degrees clockwise from 33 Ma up to 3-1-20.5 Ma and rotated counterclockwise in a few million years [De Jong et al., 1969, 1973; Bobier et Coulon, 1970; Coulon et al., 1974; Manzoni, 1974, 1975; Bellon rr nl.. 1977: Edel et Lortscher, 1977; Edel, 1979, 1980]. Since then, the end of the rotation fixed at 19 Ma by Montigny er al. [1981] was the subject of discussions and several studies associating paleomagnetism and radiometric dating were undertaken [Assorgia er al., 1994: Vigliotti et Langenheim, 1995: Deino et al., 1997; Gattacceca rt Deino, 1999]. This is a contribution to this debate that is hampered by thr important secular variation recorded in the volcanics. The only way to get our of this problem is to sample series of successive flows as completely as possible, and to reduce the effect of secular variation by the calculation of means. Sampling was performed north of Bonorva in 5 pyroclastic flows that belong to the upper ignimbritic series SI2 according to Coulon rr nl. [1974] or LBLS according to Assorgia et al. [1997] (fig. I). Ar-40/Ar-39 dating of biotites from the debris flow (MDF) has yielded an age or 18.35 +/- 0.03 Ma [Dubois, 2000]. Five of the investigated sites are located beneath the debris flow ITV, TVB, TVD, SPM85, SPM86), one site was cured in the matrix of the debris flow (MDF) and one in 4 metric blocks included in the flow (DFC). Another site was sampled in the upper ash flow (PDM) that marks the end of the pyroclastic activity, just before the marine transgression. According to micropaleontological and radiometric dating this transgression has occurred between 18.35 and 17.6 Ma [Dubois, 2000]. After removal of a soft viscous component, the thermal demagnetization generally shows a univectorial behaviour of the remanent magnetization (fig. 2a). The maximum unblocking temperatures of 580-620 degrees (tab. I) and a rapid saturation below 100 mT (fig. 3) indicate that the carrier of the characteristic magnetization is magnetite. The exception comes: from the upper site PDM in which were found two characteristic components, one with a normal polarity and low unblocking temperatures up to 350 degreesC and one with a reversed polarity and maximum unblocking temperatures at 580-600 degreesC of magnetite. After calculation of a mean direction for each flow, the mean << Al >> direction 4 degrees /57 degrees (alpha (95) = 13 degrees) computed with the mean directions for the 5 flows may be considered as weakly affected by secular variation. But the results require a more careful examination. The declinations are N to NNW beneath the debris flow. NNW in the debris flow. and NNE (or SSW) above the debris flow, The elongated distribution of the directions obtained at sites TVB and TVD. scattered from the mean direction of TV to the mean direction of MDF is interpreted as due to partial overprinting during the debris How volcanic episode, The low temperature component PDMa is likely related to the alteration seen on thin sections and is also viewed as an overprint. As NNE/SSW directions occur as well below (mean direction << B >> : 5 degrees /58 degrees) as above the debris flow (PDMb : 200 degrees/-58 degrees). the NNW directions (<< C >> : 337 degrees /64 degrees) associated with the debris flow volcanism may be interpreted as resulting from a magnetic field excursion. According to the polarity scale of Cande and Kent [1992, 1995] and the radiometric age of MDF, the directions with normal polarity (TV, TVB, TVD, SPM85. SPM86a. MDF. DFC) may represent the period 5En. while the directions with reversed polarity PDMb and SPM86b were likely acquired during the period 5Dr. Using the mean << Al >> direction, the mean << B >>, or the PDM direction (tab. I). the deviation in declination with the direction of stable Europe 6.4 degrees /58.7 degrees (alpha (95) = 8 degrees) for a selection of 4 middle Tertiary poles by Besse et Courtillot [1991] or 7 degrees /56 degrees (alpha (95) = 3 degrees) for 19 poles listed by Edel [1980] can be considered as negligible. Using the results from the uppermost ignimbritic layer of Anglona also emplaced around 18.3 Ma [Odin rt al.. 1994]. the mean direction << E >> (3 degrees /51.5 degrees) leads to the same conclusion. On the contrary, when taking into account all dated results available for the period 5En (mean direction << D >> 353 degrees /56 degrees for 45 sites) (tab. II). the deviation 13 degrees is much more significant. As the rotation of Sardinia started around 21-20.5 Ma. the assumption of a constant velocity of rotation and the deviations of the Sardinia directions with respect to the stable Europe direction locate the end of the motion between 18.3 and 17.2 or 16.7 Ma (fig. 4). During the interval 18.35-17.5 Ma, the marine transgression took place. At the same period a NE-SW shortening interpreted as resulting from the collision of Sardinia with Apulia affected different parts of the island [Letouzey et al., 1982]. Consequently, the new paleomagnetic results and the tectono-sedimentary evolution are in favour of an end of the rotation at 17.5-18 Ma.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

OBJECTIVE: To assess the effectiveness of pulsed signal therapy in the treatment of knee osteoarthritis (Kellgren II or III). METHODS: A randomized, double-blind controlled clinical trial. The first 95 patients sent to the clinic with knee osteo-arthritis were selected and randomized into treatment with pulsed signal therapy or conventional physiotherapy. Assessment included recording of usual demographic data, pertinent history, baseline medication and radiographs. Clinical evaluation was made at baseline, 6 weeks and 6 months after the end of treatment by the same blinded doctor. At each follow-up time, the patient was asked to complete a visual analogue pain scale and a Lequesne score. The doctor recorded the degree of pain on motion and the ability to move the affected knee. RESULTS: Both treatments resulted in significant improvements in pain and physical function. A statistical difference was observed only for activities of daily living, where the physiotherapy was more efficient (p<0.03). The cost of treatment with pulsed signal therapy was significantly higher, double the treatment cost of conventional physiotherapy. CONCLUSION: Like physiotherapy, pulsed signal therapy has improved the clinical state of treated patients but with no significant statistical difference. Pulsed signal therapy is, however, more expensive.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In proton magnetic resonance imaging (MRI) metallic substances lead to magnetic field distortions that often result in signal voids in the adjacent anatomic structures. Thus, metallic objects and superparamagnetic iron oxide (SPIO)-labeled cells appear as hypointense artifacts that obscure the underlying anatomy. The ability to illuminate these structures with positive contrast would enhance noninvasive MR tracking of cellular therapeutics. Therefore, an MRI methodology that selectively highlights areas of metallic objects has been developed. Inversion-recovery with ON-resonant water suppression (IRON) employs inversion of the magnetization in conjunction with a spectrally-selective on-resonant saturation prepulse. If imaging is performed after these prepulses, positive signal is obtained from off-resonant protons in close proximity to the metallic objects. The first successful use of IRON to produce positive contrast in areas of metallic spheres and SPIO-labeled stem cells in vitro and in vivo is presented.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

In this work we present a first feasibility study of the ClearPEM technology for simultaneous PET-MR imaging. The mutual electromagnetic interference (EMI) effects between both systems were evaluated on a 7 T magnet by characterizing the response behavior of the ClearPEM detectors and front-end electronics to pulsed RF power and switched magnetic field gradients; and by analyzing the MR system performance degradation from noise pickup into the RF receiver chain, and from magnetic susceptibility artifacts caused by PET front-end materials.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Among numerous magnetic resonance imaging (MRI) techniques, perfusion MRI provides insight into the passage of blood through the brain's vascular network non-invasively. Studying disease models and transgenic mice would intrinsically help understanding the underlying brain functions, cerebrovascular disease and brain disorders. This study evaluates the feasibility of performing continuous arterial spin labeling (CASL) on all cranial arteries for mapping murine cerebral blood flow at 9.4 T. We showed that with an active-detuned two-coil system, a labeling efficiency of 0.82 ± 0.03 was achieved with minimal magnetization transfer residuals in brain. The resulting cerebral blood flow of healthy mouse was 99 ± 26 mL/100g/min, in excellent agreement with other techniques. In conclusion, high magnetic fields deliver high sensitivity and allowing not only CASL but also other MR techniques, i.e. (1)H MRS and diffusion MRI etc, in studying murine brains.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

With improved B 0 homogeneity along with satisfactory gradient performance at high magnetic fields, snapshot gradient-recalled echo-planar imaging (GRE-EPI) would perform at long echo times (TEs) on the order of T2*, which intrinsically allows obtaining strongly T2*-weighted images with embedded substantial anatomical details in ultrashort time. The aim of this study was to investigate the feasibility and quality of long TE snapshot GRE-EPI images of rat brain at 9.4 T. When compensating for B 0 inhomogeneities, especially second-order shim terms, a 200 x 200 microm2 in-plane resolution image was reproducibly obtained at long TE (>25 ms). The resulting coronal images at 30 ms had diminished geometric distortions and, thus, embedded substantial anatomical details. Concurrently with the very consistent stability, such GRE-EPI images should permit to resolve functional data not only with high specificity but also with substantial anatomical details, therefore allowing coregistration of the acquired functional data on the same image data set.