970 resultados para Golder, Kurt
Resumo:
To evaluate the current management, and adherence to recommendations, of patients on oral anticoagulation (OAC) undergoing coronary stent implantation (PCI-S).
Resumo:
Background. The definition of fever, and thus fever and neutropenia (FN), varies between different pediatric oncology centers. Higher temperature limit should reduce FN rates, but may increase rates of FN with complications by delaying therapy. This study determined if different fever definitions are associated with different FN rates. Procedure. Two pediatric oncology centers had used three fever definitions in 2004–2011: ear temperature >=38.5°C persisting >=2 hours (low definition); axillary temperature >=38.5°C >=2 hours or >=39.0°C once (middle); and ear temperature >=39.0°C once (high). Clinical information was retrospectively extracted from charts. FN rates were compared using mixed Poisson regression. Results. In 521 pediatric patients with cancer, 783 FN were recorded during 6,009 months cumulative chemotherapy exposure time (501 years; rate, 0.13/month [95% CI, 0.12–0.14]), 124 of them with bacteremia (16%; 0.021/month [0.017–0.025]). In univariate analysis, the high versus low fever definition was associated with a lower FN rate (0.10/month [0.08–0.11] vs. 0.15/month [0.13–0.16]; rate ratio, 0.66 [0.45–0.97]; P ¼ 0.036), the middle definition was intermediate (0.13/month [0.11–0.15]). This difference was not confirmed in multivariate analysis (rate ratio, 0.94 [0.67–1.33]; P ¼ 0.74). The high versus low definition was not associated with an increased rate of FN with bacteremia (multivariate rate ratio, 1.39 [0.53–3.62]; P ¼ 0.50). Conclusion. A higher fever definition was not associated with a lower FN rate, nor with an increased rate of FN with bacteremia. These may be false negative findings due to methodological limitations. These questions, with their potential impact on health-related quality of life, and on costs, need to be assessed in prospective studies.
Resumo:
The standard treatment of fever in chemotherapy-induced neutropenia (FN) includes emergency hospitalization and empirical intravenous antimicrobial therapy. This study determined if first-day step-down to oral outpatient treatment is not inferior to continued standard regarding safety and efficacy in children with low-risk FN.
Resumo:
This systematic review and meta-analysis compared the efficacy of different anthracyclines and anthracycline dosing schedules for induction therapy in acute myeloid leukaemia in children and adults younger than 60 years of age. Twenty-nine randomized controlled trials were eligible for inclusion in the review. Idarubicin (IDA), in comparison to daunorubicin (DNR), reduced remission failure rates (risk ratio (RR) 0·81; 95% confidence interval (CI), 0·66-0·99; P = 0·04), but did not alter rates of early death or overall mortality. Superiority of IDA for remission induction was limited to studies with a DNR/IDA dose ratio <5 (ratio <5: RR 0·65; 95% CI, 0·51-0·81; P < 0·001; ratio ≥5: RR 1·03; 95% CI, 0·91-1·16; P = 0·63). Higher-dose DNR, compared to lower-dose DNR, was associated with reduced rates for remission failure (RR 0·75; 95% CI, 0·60-0·94; P = 0·003) and overall mortality (RR 0·83; 95% CI, 0·75-0·93; P < 0·001), but not for early death. Comparisons of several other anthracycline derivates did not reveal significant differences in outcomes. Survival estimates in adults suggest that both high-dose DNR (90 mg/m(2) daily × 3 or 50 mg/m(2) daily × 5) and IDA (12 mg/m(2) daily × 3) can achieve 5-year survival rates of between 40 and 50 percent.
Resumo:
During follow-up of between 1 and 3 years in the Randomized Evaluation of Long-term Anticoagulation Therapy (RE-LY) trial, 2 doses of dabigatran etexilate were shown to be effective and safe for the prevention of stroke or systemic embolism in patients with atrial fibrillation. There is a need for longer-term follow-up of patients on dabigatran and for further data comparing the 2 dabigatran doses.
Resumo:
OBJECTIVE: While systemic glucocorticoids compromise bone metabolism, altered intracellular cortisol availability may also contribute to the pathogenesis of primary male osteoporosis (MO). The objective of this study was to assess whether intracellular cortisol availability is increased in MO due to a distorted local cortisol metabolism. METHODS: Forty-one patients with MO were compared with age- and BMI-matched non-osteoporotic subjects after excluding overt systemic hypercortisolism (N = 41). Cortisol, cortisone and the respective tetrahydro-, 5α-tetrahydro- and total cortisol metabolites were analysed by GC-MS in 24 h urine. Apparent 11β-hydroxysteroid dehydrogenase (11β-HSD) enzyme activities, excretion of cortisol metabolites and calcium, and fractional urinary calcium excretion were assessed and related to BMD. RESULTS: Fractional and total urinary calcium excretion negatively correlated with BMD at all (P < 0.05) and at three of five (P < 0.05) measurement sites, respectively. While systemic cortisol was unchanged, apparent 11β-HSD enzyme activity in MO patients (P < 0.01) suggested increased intracellular cortisol availability. Total and fractional urinary calcium excretion was higher, with apparent 11β-HSD enzyme activities consistent with an enhanced intracellular cortisol availability (P < 0.05). CONCLUSION: Apparent 11β-HSD enzyme activities consistent with increased intracellular cortisol availability correlated with urinary calcium loss and reduced bone mineral density in MO. The changes in 11β-HSD activity were associated with both the fractional calcium excretion, suggesting altered renal calcium handling, and the absolute urinary calcium excretion. Both mechanisms could result in a marked bone calcium deficiency if insufficiently compensated for by intestinal calcium uptake.
High accuracy alignment facility for the receiver and transmitter of the BepiColombo Laser Altimeter
Resumo:
The accurate co-alignment of the transmitter to the receiver of the BepiColombo Laser Altimeter is a challenging task for which an original alignment concept had to be developed. We present here the design, construction and testing of a large collimator facility built to fulfill the tight alignment requirements. We describe in detail the solution found to attenuate the high energy of the instrument laser transmitter by an original beam splitting pentaprism group. We list the different steps of the calibration of the alignment facility and estimate the errors made at each of these steps. We finally prove that the current facility is ready for the alignment of the flight instrument. Its angular accuracy is 23 μrad.