964 resultados para Future Value
Resumo:
Objective: Cardiac Troponin-I (cTnI) is a well-recognized early postoperative marker for myocardial damage in adults and children after heart surgery. The present study was undertaken to evaluate whether the integrated value (area under the curve(AUC)) of postoperative cTnI is a better mode to predict long-term outcome than post operative cTnI maximum value, after surgery for congenital heart defects (CHD). Methods: retrospective cohort study. 279 patients (mean age 4.6 years; range 0-17 years-old, 185 males) with congenital heart defect repair on cardiopulmonary by-pass were retrieved from our database including postoperative cTnI values. Maximal post operative cTnI value, post operative cTnI AUC value at 48h and total post operative cTnI AUC value were calculated and then correlated with duration of intubation, duration of ICU stay and mortality. Results: the mean duration of mechanical ventilation was 5.1+/-7.2 days and mean duration of ICU stay was 11.0+/- 13.3 days,11 patients (3.9%) died in post operative period. When comparing survivor and deceased groups, there was a significant difference in the mean value for max cTnI (16.7+/- 21.8 vs 59.2+/-41.4 mcg/l, p+0.0001), 48h AUC cTnI (82.0+/-110.7 vs 268.8+/-497.7 mcg/l, p+0.0001) and total AUC cTnI (623.8+/-1216.7 vs 2564+/-2826.0, p+0.0001). Analyses for duration of mechanical ventilation and duration of ICU stay by linear regression demonstrated a better correlation for 48h AUC cTnI (ventilation time r+0.82, p+0.0001 and ICU stay r+0.74, p+0.0001) then total AUC cTnI (ventilation time r+0.65, p+0.0001 and ICU stay r+0.60, p+0.0001) and max cTnI (ventilation time r+0.64, p+0.0001 and ICU stay r+0.60, p+0.0001). Conclusion: Cardiac Troponin I is a specific and sensitive marker of myocardial injury after congenital heart surgery and it may predict early in-hospital outcomes. Integration of post operative value of cTnI by calculation of AUC improves prediction of early in-hospital outcomes. It probably takes into account, not only the initial surgical procedure, but probably also incorporates the occurrence of hypoxic-ischemic phenomena in the post-operative period.
Resumo:
Recently, morphometric measurements of the ascending aorta have been done with ECG-gated multidector computerized tomography (MDCT) to help the development of future novel transcatheter therapies (TCT); nevertheless, the variability of such measurements remains unknown. Thirty patients referred for ECG-gated CT thoracic angiography were evaluated. Continuous reformations of the ascending aorta, perpendicular to the centerline, were obtained automatically with a commercially available computer aided diagnosis (CAD). Then measurements of the maximal diameter were done with the CAD and manually by two observers (separately). Measurements were repeated one month later. The Bland-Altman method, Spearman coefficients, and a Wilcoxon signed-rank test were used to evaluate the variability, the correlation, and the differences between observers. The interobserver variability for maximal diameter between the two observers was up to 1.2 mm with limits of agreement [-1.5, +0.9] mm; whereas the intraobserver limits were [-1.2, +1.0] mm for the first observer and [-0.8, +0.8] mm for the second observer. The intraobserver CAD variability was 0.8 mm. The correlation was good between observers and the CAD (0.980-0.986); however, significant differences do exist (P<0.001). The maximum variability observed was 1.2 mm and should be considered in reports of measurements of the ascending aorta. The CAD is as reproducible as an experienced reader.