1000 resultados para Fold Block-designs


Relevância:

20.00% 20.00%

Publicador:

Resumo:

A Kubergandian (Kungurian) fusuline fauna from the lower part of the Lugu Formation in the Cuozheqiangma area, central Qiangtang Block is described. This fusuline fauna belongs to the Southern Transitional Zone in palaeobiogeography, and is characterised by the presence of the distinctive bi-temperate genus Monodiexodina and many genera common in lower latitude Tethyan areas such as Parafusulina and Pseudodoliolina. The occurrence of Monodiexodina in the fauna confirms that the seamount-type carbonates of the Lugu Formation did not originate from the Palaeotethys Ocean, but rather from a branch of the Neotethys Ocean after the rifting of the Qiangtang Block from the Tethys Himalaya area in the Artinskian. © 2014 Geological Society of China.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As a significant milestone in the data dissemination of wireless sensor networks (WSNs), the comb-needle (CN) model was developed to dynamically balance the sensor data pushing and pulling during hybrid data dissemination. Unfortunately, the hybrid push-pull data dissemination strategy may overload some sensor nodes and form the hotspots that consume energy significantly. This usually leads to the collapse of the network at a very early stage. In the past decade, although many energy-aware dynamic data dissemination methods have been proposed to alleviate the hotspots issue, the block characteristic of sensor nodes has been overlooked and how to offload traffic from hot blocks with low energy through long-distance hybrid dissemination remains an open problem. In this paper, we developed a block-aware data dissemination model to balance the inter-block energy and eliminate the spreading of intra-block hotspots. Through the clustering mechanism based on geography and energy, "similar" large-scale sensor nodes can be efficiently grouped into specific blocks to form the global block information (GBI). Based on GBI, the long-distance block-cross hybrid algorithms are further developed by effectively aggregating inter-block and intra-block data disseminations. Extensive experimental results demonstrate the capability and the efficiency of the proposed approach. © 2014 Elsevier Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The remarkable physical properties of ionic liquids (ILs) make them potentially excellent lubricants. One of the challenges for using ILs as lubricants is their high cost. In this article, atomic force microscopy (AFM) nanotribology measurements reveal that a 1 mol % solution of IL dissolved in an oil lubricates the silica surface as effectively as the pure IL. The adsorption isotherm shows that the IL surface excess need only be approximately half of the saturation value to prevent surface contact and effectively lubricate the sliding surfaces. Using ILs in this way makes them viable for large-scale applications.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A viable method of encapsulating block copolymer micelles inside vesicles using a conjugated polymer is reported in this study. Self-assembly and complexation between an amphiphilic block copolymer poly(methyl methacrylate)-b-poly(acrylic acid) (PMMA-b-PAA) and a rod-like conjugated polymer polyaniline (PANI) in aqueous solution were studied using transmission electron microscopy, atomic force microscopy and dynamic light scattering. The complexation and morphology transformation were driven by electrostatic interaction between PANI and the PAA block of the block copolymer. Addition of PANI to PMMA-b-PAA induced the morphology transformation from micelles to irregular vesicles through vesicles, thick-walled vesicles (TWVs) and multimicellar vesicles (MMVs). Among the observed morphologies, MMVs were observed for the first time. Morphology transformation was studied as a function of aniline/acrylic acid molar ratio ([ANI]/[AA]). Micelles were observed for the pure block copolymer, while vesicles and TWVs were observed at [ANI]/[AA] = 0.1 and 0.3, respectively. MMVs were observed at [ANI]/[AA] = 0.5 and irregular vesicles were observed for molar ratios at 0.7 and above. Clearly, a conjugated polymer like polyaniline can induce a morphology transformation even at its lower concentrations and produce complex morphologies.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Morphology evolution in complexes of amphiphilic block copolymers poly(styrene)-b-poly(acrylic acid) (PS-b-PAA) and poly(styrene)-b-poly(ethylene oxide) (PS-b-PEO) in the presence of polyaniline (PANI) in aqueous solution is reported. Transmission electron microscopy, atomic force microscopy, and dynamic light scattering techniques were used to study the morphologies at various PANI contents [aniline]/[acrylic acid] ([ANI]/[AA]) ranging from 0.1 to 0.7. The interpolyelectrolyte complex formed between PAA and PANI plays a key role in the morphology transformation. Spherical micelles formed from pure block copolymers were transformed into large compound vesicles upon increasing PANI concentration due to internal block copolymer segregation. In addition to varying PANI content, the kinetic pathway of nanoparticle formation was controlled through different water addition methods and was critical in the formation of multigeometry nanoparticles.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this work, the crystallization rates and spherulitic growth rate of miscible blends of poly(vinylidene fluoride) (PVDF) and acrylic rubber (ACM) were determined using differential scanning calorimetry (DSC), real-time FTIR, and optical microscopy. FTIR results suggest that blending does not induce the creation of polymorphic crystalline forms of PVDF. SAXS data demonstrate the formation of interlamellar structure after blending. The fold surface-free energy (σ e) was analyzed and compared using different thermal analysis techniques. The isothermal crystallization curves obtained using real-time FTIR and DSC explored in two different methods: t 1/2 or Avrami equation. While the Avrami equation is more widespread and precise, both analytical methods gave similar free energy of folding values. However, it was found that the direct optical method of measuring spherulitic growth rate yields σ e values 30-50 % lower than those obtained from the overall crystallization rate data. Conversely, the σ e values were found to increase with increasing amorphous ACM phase content regardless of the analytical methods.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Autologous vein-graft failure significantly limits the long-term efficacy of coronary artery bypass procedures. The major cause behind this complication is biomechanical mismatch between the vein and coronary artery. The implanted vein experiences a sudden increase (10-12 fold) in luminal pressures. The resulting vein over-distension or 'ballooning' initiates wall thickening phenomenon and ultimate occlusion. Therefore, a primary goal in improving the longevity of a coronary bypass procedure is to inhibit vein over-distension using mechanical constriction. The idea of using an external vein-graft support mesh has demonstrated sustained benefits and wide acceptance in experimental studies. Nitinol based knitted structures have offered more promising mechanical features than other mesh designs owing to their unique loosely looped construction. However, the conventional plain knit construction still exhibits limitations (radial compliance, deployment ease, flexibility, and bending stresses) which limit this design from proving its real clinical advantage. The new knitted mesh design presented in this study is based on the concept of composite knitting utilising high modulus (nitinol and polyester) and low modulus (polyurethane) material components. The experimental comparison of the new design with a plain knit design demonstrated significant improvement in biomechanical (compliance, flexibility, extensibility, viscoelasticity) and procedural (deployment limit) parameters. The results are indicative of the promising role of new mesh in restoring the lost compliance and pulsatility of vein-graft at high arterial pressures. This way it can assist in controlled vein-graft remodelling and stepwise restoration of vein mechanical homoeostasis. Also, improvement in deployment limit parameter offers more flexibility for a surgeon to use a wide range of vein diameters, which may otherwise be rendered unusable for a plain knit mesh.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A novel tri-block copolymer poly(oxopentanoate ethyl methacrylate)-block-poly(pyridyl disulfide ethyl acrylate)-block-poly(ethylene glycol acrylate) [poly(OEMA-b-PDEA-b-PEGA)], retaining active keto groups and pyridyl disulfide (PDS) side functionalities, was synthesized as a drug delivery vehicle using reversible addition-fragmentation chain transfer (RAFT) polymerization method. One mimic drug pyridine-2-thione (PT) was introduced into the monomer, PDEA for copolymerization. The other mimic drug O-benzylhydroxylamine (BHA) was conjugated with tri-block copolymer via efficient oxime coupling chemistry, followed by the attachment onto graphene via π-π stacking interaction to obtain a graphene/tri-block copolymer composite. 1H NMR, UV-vis absorption spectroscopy, fluorescence spectroscopy, gel permeation chromatography (GPC), atomic force microscope (AFM) and transmission electron microscope (TEM) were used to verify the successful step-wise preparation of the tri-block copolymer and drug loaded composite. In vitro release behaviors of BHA and PT from graphene/tri-block copolymer composite via dual drug release mechanisms were investigated. BHA can be released under acid environment, while PT will be released in the presence of reducing agents, such as dithiothreitol (DTT) or glutathione (GSH). It can be envisioned that this novel composite could be exploited as a novel intracellular drug delivery system via dual release mechanisms.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Here we report the effect of multi-walled carbon nanotubes (MWCNTs) and thermally reduced graphene (TRG) on the miscibility, morphology and final properties of nanostructured epoxy resin with an amphiphilic poly(ethylene oxide)-poly(propylene oxide)-poly(ethylene oxide) (PEO-PPO-PEO) triblock copolymer. The addition of nanoparticles did not have any influence on the miscibility of PEO-PPO-PEO copolymer in the resin. However, MWCNTs and TRG reduced the degree of crystallinity of the PEO-rich microphases in the blends above 10 wt.% of copolymer while they did not change the phase morphology at the nanoscale, where PPO spherical domains of 20-30 nm were found in all the samples studied. A synergic effect between the self-assembled nanostructure and the nanoparticles on the toughness of the cured resin was observed. In addition, the nanoparticles minimized the negative effect of the copolymer on the elastic modulus and glass transition temperature in the resin.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

 This thesis describes the procedure for preparing polymer nanoparticles of various morphologies via simple complexation technique. The nanoparticles observed in this study may find potential application in drug delivery, diagnostic imaging, nano reactors, catalysis and preparation of stimuli responsive materials.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The turnrow Anthology of Contemporary Australian Poetry, edited by John Kinsella, features the work of 123 poets.

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The recent advances in CMOS technology have allowed for the fabrication of transistors with submicronic dimensions, making possible the integration of tens of millions devices in a single chip that can be used to build very complex electronic systems. Such increase in complexity of designs has originated a need for more efficient verification tools that could incorporate more appropriate physical and computational models. Timing verification targets at determining whether the timing constraints imposed to the design may be satisfied or not. It can be performed by using circuit simulation or by timing analysis. Although simulation tends to furnish the most accurate estimates, it presents the drawback of being stimuli dependent. Hence, in order to ensure that the critical situation is taken into account, one must exercise all possible input patterns. Obviously, this is not possible to accomplish due to the high complexity of current designs. To circumvent this problem, designers must rely on timing analysis. Timing analysis is an input-independent verification approach that models each combinational block of a circuit as a direct acyclic graph, which is used to estimate the critical delay. First timing analysis tools used only the circuit topology information to estimate circuit delay, thus being referred to as topological timing analyzers. However, such method may result in too pessimistic delay estimates, since the longest paths in the graph may not be able to propagate a transition, that is, may be false. Functional timing analysis, in turn, considers not only circuit topology, but also the temporal and functional relations between circuit elements. Functional timing analysis tools may differ by three aspects: the set of sensitization conditions necessary to declare a path as sensitizable (i.e., the so-called path sensitization criterion), the number of paths simultaneously handled and the method used to determine whether sensitization conditions are satisfiable or not. Currently, the two most efficient approaches test the sensitizability of entire sets of paths at a time: one is based on automatic test pattern generation (ATPG) techniques and the other translates the timing analysis problem into a satisfiability (SAT) problem. Although timing analysis has been exhaustively studied in the last fifteen years, some specific topics have not received the required attention yet. One such topic is the applicability of functional timing analysis to circuits containing complex gates. This is the basic concern of this thesis. In addition, and as a necessary step to settle the scenario, a detailed and systematic study on functional timing analysis is also presented.